Advertisement for orthosearch.org.uk
Results 1 - 100 of 169
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 727 - 735
1 Jun 2020
Burger JA Dooley MS Kleeblad LJ Zuiderbaan HA Pearle AD

Aims. It remains controversial whether patellofemoral joint pathology is a contraindication to lateral unicompartmental knee arthroplasty (UKA). This study aimed to evaluate the effect of preoperative radiological degenerative changes and alignment on patient-reported outcome scores (PROMs) after lateral UKA. Secondarily, the influence of lateral UKA on the alignment of the patellofemoral joint was studied. Methods. A consecutive series of patients who underwent robotic arm-assisted fixed-bearing lateral UKA with at least two-year follow-up were retrospectively reviewed. Radiological evaluation was conducted to obtain a Kellgren Lawrence (KL) grade, an Altman score, and alignment measurements for each knee. Postoperative PROMs were assessed using the Kujala (Anterior Knee Pain Scale) score, Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), and satisfaction levels. Results. A total of 140 knees (130 patients) were identified for analysis. At mean 4.1 years (2.0 to 8.5) follow-up, good to excellent Kujala scores were reported. The presence of mild to moderate preoperative patellofemoral joint osteoarthritis had no impact on these scores (KL grade 0 vs 1 to 3, p = 0.203; grade 0 to 1 vs 2 to 3, p = 0.674). Comparable scores were reported by patients with osteoarthritis (Altman score of ≥ 2) evident on either the medial or lateral patellofemoral joint facet (medial, p = 0.600 and lateral, p = 0.950). Patients with abnormal patellar congruence and tilt angles (≥ 17° and ≥ 14°, respectively) reported good to excellent Kujala scores. Furthermore, lateral UKA resulted in improvements to patellofemoral alignment. Conclusion. This is the first study demonstrating that mild to moderate preoperative radiological degenerative changes and malalignment of the patellofemoral joint are not associated with poor patient-reported outcomes at mid-term follow-up after lateral fixed-bearing UKA. Our data suggest that this may be explained by realignment of the patella and thereby redistribution of loads across the patellofemoral joint. Cite this article: Bone Joint J 2020;102-B(6):727–735


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1585 - 1591
1 Dec 2018
Kaneko T Kono N Mochizuki Y Hada M Sunakawa T Ikegami H Musha Y

Aims. Patellofemoral problems are a common complication of total knee arthroplasty. A high compressive force across the patellofemoral joint may affect patient-reported outcome. However, the relationship between patient-reported outcome and the intraoperative patellofemoral contact force has not been investigated. The purpose of this study was to determine whether or not a high intraoperative patellofemoral compressive force affects patient-reported outcome. Patients and Methods. This prospective study included 42 patients (42 knees) with varus-type osteoarthritis who underwent a bi-cruciate stabilized total knee arthroplasty and in whom the planned alignment was confirmed on 3D CT. Of the 42 patients, 36 were women and six were men. Their mean age was 72.3 years (61 to 87) and their mean body mass index (BMI) was 24.4 kg/m2 (18.2 to 34.3). After implantation of the femoral and tibial components, the compressive force across the patellofemoral joint was measured at 10°, 30°, 60°, 90°, 120°, and 140° of flexion using a load cell (Kyowa Electronic Instruments Co., Ltd., Tokyo, Japan) manufactured in the same shape as the patellar implant. Multiple regression analyses were conducted to investigate the relationship between intraoperative patellofemoral compressive force and patient-reported outcome two years after implantation. Results. No patient had anterior knee pain after total knee arthroplasty. The compressive force across the patellofemoral joint at 140°of flexion was negatively correlated with patient satisfaction (R2 = 0.458; β = –0.706; p = 0. 041) and Forgotten Joint Score-12 (FJS-12; R2= .378; β = –0.636; p = 0. 036). The compressive force across the patellofemoral joint at 60° of flexion was negatively correlated with the patella score (R2 = 0.417; β = –0.688; p = 0. 046). Conclusion. Patient satisfaction, FJS-12, and patella score were affected by the patellofemoral compressive force at 60° and 140° of flexion. Reduction of the patellofemoral compressive forces at 60° and 140° of flexion angle during total knee arthroplasty may improve patient-reported outcome, but has no effect on anterior knee pain


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1579 - 1582
1 Dec 2009
Starks I Roberts S White SH

We present a prospective review of the two-year functional outcome of 37 Avon patellofemoral joint replacements carried out in 29 patients with a mean age of 66 years (30 to 82) between October 2002 and March 2007. No patients were lost to follow-up. This is the first independent assessment of this prosthesis using both subjective and objective analysis of outcome. At two years the median Oxford knee score was 39 (interquartile range 32 to 44), the median American Knee Society objective score was 95 (interquartile range 90 to 100), the median American Knee Society functional score was 85 (interquartile range 60 to 100), and the median Melbourne Knee score was 28 (interquartile range 21 to 30). Two patients underwent further surgery. Only one patient reported an unsatisfactory outcome. We conclude that the promising early results observed by the designing centre are reproducible and provide further support for the role of patellofemoral joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1602 - 1607
1 Dec 2007
Beard DJ Pandit H Ostlere S Jenkins C Dodd CAF Murray DW

Anterior knee pain and/or radiological evidence of degeneration of the patellofemoral joint are considered to be contraindications to unicompartmental knee replacement. The aim of this study was to determine whether this is the case. Between January 2000 and September 2003, in 100 knees (91 patients) in which Oxford unicompartmental knee replacements were undertaken for anteromedial osteoarthritis, pre-operative anterior knee pain and the radiological status of the patellofemoral joint were defined using the Altman and Ahlback systems. Outcome was evaluated at two years with the Oxford knee score and the American Knee Society score. Pre-operatively 54 knees (54%) had anterior knee pain. The clinical outcome was independent of the presence or absence of pre-operative anterior knee pain. Degenerative changes of the patellofemoral joint were seen in 54 patients (54%) on the skyline radiographs, including ten knees (10%) with joint space obliteration. Patients with medial patellofemoral degeneration had a similar outcome to those without. For some outcome measures patients with lateral patellofemoral degeneration had a worse score than those without, but these patients still had a good outcome, with a mean Oxford knee score of 37.6 (SD 9.5). These results show that neither anterior knee pain nor radiologically-demonstrated medial patellofemoral joint degeneration should be considered a contraindication to Oxford unicompartmental knee replacement. With lateral patellofemoral degeneration the situation is less well defined and caution should be observed


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 552 - 558
1 May 2019
Clark D Stevens JM Tortonese D Whitehouse MR Simpson D Eldridge J

Aims. The aim of this study was to determine and compare the congruency of the articular surface contact area of the patellofemoral joint (PFJ) during both active and passive movement of the knee with the use of an MRI mapping technique in both the stable and unstable PFJ. Patients and Methods. A prospective case-control MRI imaging study of patients with a history of PFJ instability and a control group of volunteers without knee symptoms was performed. The PFJs were imaged with the use of an MRI scan during both passive and active movement from 0° through to 40° of flexion. The congruency through measurement of the contact surface area was mapped in 5-mm intervals on axial slices. In all, 40 patients were studied. The case group included 31 patients with symptomatic patellofemoral instability and the control group of nine asymptomatic volunteers. The ages were well matched between the case and control groups. The mean age was 25 years (16 to 42; . sd. 6.9) in the case group and 26 years (19 to 32; . sd. 5.1) in the control group. There were 19 female and 12 male patients in the case group. Results. The unstable PFJs were demonstrably less congruent than the stable PFJs throughout the range of knee movement. The greatest mean differences in congruency between unstable and stable PFJ’s were observed between 11° and 20° flexion (1.73 cm. 2. vs 4.00 cm. 2. ; p < 0.005). . Conclusion. The unstable PFJ is less congruent than the stable PFJ throughout the range of knee movement studied. This approach to mapping PFJ congruency produces a measurable outcome and will allow the assessment of pre- and postoperative results following surgical intervention. This may facilitate the design of new procedures for patients with PFJ instability. If a single axial series is to be obtained on MRI scan, the authors recommend 11° to 20° of tibiofemoral flexion, as this was shown to have the greatest difference in contact surface area between the case and control groups. Cite this article: Bone Joint J 2019;101-B:552–558


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 56 - 60
1 Jan 2010
Odumenya M Costa ML Parsons N Achten J Dhillon M Krikler SJ

Between May 1998 and May 2007 we carried out 50 Avon patellofemoral joint replacements in 32 patients with isolated patellofemoral osteoarthritis. There were no revisions in the first five years, giving a cumulative survival of 100% for those with a minimum follow-up of five years. The mean follow-up was 5.3 years (2.1 to 10.2). The median Oxford knee score was 30.5 (interquartile range 22.25 to 42.25). In patients with bilateral replacements the median Euroqol General health score was 50 which was significantly lower than that of 75 in those with a unilateral replacement (p = 0.047). The main complication was progression of disease, which was identified radiologically in 11 knees (22%). This highlights the need for accurate selection of patients. Our findings suggest that the Avon prosthesis survives well and gives a satisfactory functional outcome in the medium term


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 408 - 412
1 Mar 2007
Ma H Lu Y Kwok T Ho F Huang C Huang C

One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines. The Total Condylar prosthesis had the lowest conformity with the native patella (mean 8.58°; 0.14° to 29.9°) and with its own patellar component (mean 11.36°; 0.55° to 39.19°). In the other four prostheses, the conformity was better (mean 2.25°; 0.02° to 10.52°) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity (mean 6.51°; 0.07° to 9.89°) than the Miller-Galante II prosthesis (mean 11.20°; 5.80° to 16.72°) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid (mean 3.57°; 1.40° to 4.56°) or high angles of flexion (mean 4.54°; 0.91° to 9.39°), respectively. The Low Contact Stress femoral component had the best conformity with the native patella (mean 2.39°; 0.04° to 4.56°). There was no significant difference (p > 0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion. The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 892 - 897
1 Sep 2024
Mancino F Fontalis A Kayani B Magan A Plastow R Haddad FS

Advanced 3D imaging and CT-based navigation have emerged as valuable tools to use in total knee arthroplasty (TKA), for both preoperative planning and the intraoperative execution of different philosophies of alignment. Preoperative planning using CT-based 3D imaging enables more accurate prediction of the size of components, enhancing surgical workflow and optimizing the precision of the positioning of components. Surgeons can assess alignment, osteophytes, and arthritic changes better. These scans provide improved insights into the patellofemoral joint and facilitate tibial sizing and the evaluation of implant-bone contact area in cementless TKA. Preoperative CT imaging is also required for the development of patient-specific instrumentation cutting guides, aiming to reduce intraoperative blood loss and improve the surgical technique in complex cases. Intraoperative CT-based navigation and haptic guidance facilitates precise execution of the preoperative plan, aiming for optimal positioning of the components and accurate alignment, as determined by the surgeon’s philosophy. It also helps reduce iatrogenic injury to the periarticular soft-tissue structures with subsequent reduction in the local and systemic inflammatory response, enhancing early outcomes. Despite the increased costs and radiation exposure associated with CT-based navigation, these many benefits have facilitated the adoption of imaged based robotic surgery into routine practice. Further research on ultra-low-dose CT scans and exploration of the possible translation of the use of 3D imaging into improved clinical outcomes are required to justify its broader implementation. Cite this article: Bone Joint J 2024;106-B(9):892–897


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 452 - 458
1 May 1999
Stäubli H Dürrenmatt U Porcellini B Rauschning W

We studied the anatomy of the patellofemoral joint in the axial plane on cryosections from a cadaver knee and on MR arthrotomograms from 30 patients. The cryosections revealed differences in the geometry and anatomy of the surface of the articular cartilage and corresponding subchondral osseous contours of the patellofemoral joint. On the MR arthrotomograms the surface geometry of the cartilage matched the osseous contour of the patella in only four of the 30 knees. The articular cartilaginous surface of the intercondylar sulcus and corresponding osseous contour of the femoral trochlea matched in only seven knees. Since MR arthrotomography can distinguish between the surface geometry of the articular cartilage and subchondral osseous anatomy of the patellofemoral joint, it allows the surgeon and the radiologist to appraise the true articulating surfaces. We therefore recommend MR arthrotomography as the imaging technique of choice


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 632 - 639
1 May 2017
Hamilton TW Pandit HG Maurer DG Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims. It is not clear whether anterior knee pain and osteoarthritis (OA) of the patellofemoral joint (PFJ) are contraindications to medial unicompartmental knee arthroplasty (UKA). Our aim was to investigate the long-term outcome of a consecutive series of patients, some of whom had anterior knee pain and PFJ OA managed with UKA. Patients and Methods. We assessed the ten-year functional outcomes and 15-year implant survival of 805 knees (677 patients) following medial mobile-bearing UKA. The intra-operative status of the PFJ was documented and, with the exception of bone loss with grooving to the lateral side, neither the clinical or radiological state of the PFJ nor the presence of anterior knee pain were considered a contraindication. The impact of radiographic findings and anterior knee pain was studied in a subgroup of 100 knees (91 patients). Results. There was no relationship between functional outcomes, at a mean of ten years, or 15-year implant survival, and pre-operative anterior knee pain, or the presence or degree of cartilage loss documented intra-operatively at the medial patella or trochlea, or radiographic evidence of OA in the medial side of the PFJ. In 6% of cases there was full thickness cartilage loss on the lateral side of the patella. In these cases, the overall ten-year function and 15-year survival was similar to those without cartilage loss; however they had slightly more difficulty with descending stairs. Radiographic signs of OA seen in the lateral part of the PFJ were not associated with a definite compromise in functional outcome or implant survival. Conclusion. Severe damage to the lateral side of the PFJ with bone loss and grooving remains a contraindication to mobile-bearing UKA. Less severe damage to the lateral side of the PFJ and damage to the medial side, however severe, does not compromise the overall function or survival, so should not be considered to be a contraindication. However, if a patient does have full thickness cartilage loss on the lateral side of the PFJ they may have a slight compromise in their ability to descend stairs. Pre-operative anterior knee pain also does not compromise the functional outcome or survival and should not be considered to be a contraindication. Cite this article: Bone Joint J 2017;99-B:632–9


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1324 - 1328
1 Oct 2007
Chang CB Han I Kim SJ Seong SC Kim TK

We investigated the association between the radiological findings and the symptoms arising from the patellofemoral joint in advanced osteoarthritis (OA) of the knee. Four radiological features, joint space narrowing, osteophyte formation, translation of the patella and focal attrition were assessed in 151 consecutive osteoarthritic knees in 107 patients undergoing total knee replacement. The symptoms which were assessed included anterior knee pain which was scored, the ability to rise from a chair and climb stairs, and quadriceps weakness. Among the radiological features, only patellar translation and obliteration of the joint space had a statistically significant association with anterior knee pain (odds ratio (OR) 4.85; 95% confidence interval (CI) 1.83 to 12.88 and OR 11.23; 95% CI 2.44 to 51.62) respectively. Patellar translation had a statistically significant association with difficulty in rising from a chair (OR 9.06; 95% CI 1.75 to 45.11). Other radiological features, including osteophytes, joint space narrowing, and focal attrition had no significant association. Our study indicates that the radiological findings of patellar translation and significant loss of cartilage are predictive of patellofemoral symptoms and functional limitation in advanced OA of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 577 - 582
1 Apr 2005
Senavongse W Amis AA

Normal function of the patellofemoral joint is maintained by a complex interaction between soft tissues and articular surfaces. No quantitative data have been found on the relative contributions of these structures to patellar stability. Eight knees were studied using a materials testing machine to displace the patella 10 mm laterally and medially and measure the force required. Patellar stability was tested from 0° to 90° knee flexion with the quadriceps tensed to 175 N. Four conditions were examined: intact, vastus medialis obliquus relaxed, flat lateral condyle, and ruptured medial retinaculae. Abnormal trochlear geometry reduced the lateral stability by 70% at 30° flexion, while relaxation of vastus medialis obliquus caused a 30% reduction. Ruptured medial retinaculae had the largest effect at 0° flexion with 49% reduction. There was no effect on medial stability. There is a complex interaction between these structures, with their contributions to loss of lateral patellar stability varying with knee flexion


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 420 - 421
1 May 2024
Oussedik S Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 701 - 701
1 Jul 1997
Walker KA


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1597 - 1601
1 Dec 2007
Beard DJ Pandit H Gill HS Hollinghurst D Dodd CAF Murray DW

Patellofemoral joint degeneration is often considered a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on the intra-operative status of the patellofemoral joint in 824 knees in 793 consecutive patients who underwent Oxford unicondylar knee replacement for anteromedial osteoarthritis. All operations were performed between January 1998 and September 2005. A five-point grading system classified degeneration of the patellofemoral joint from none to full-thickness cartilage loss. A subclassification of the presence or absence of any full-thickness cartilage loss was subsequently performed to test selected hypotheses. Outcome was evaluated independently by physiotherapists using the Oxford and the American Knee Society Scores with a minimum follow-up of one year. Full-thickness cartilage loss on the trochlear surface was observed in 100 of 785 knees (13%), on the medial facet of the patella in 69 of 782 knees (9%) and on the lateral facet in 29 of 784 knees (4%). Full-thickness cartilage loss at any location was seen in 128 knees (16%) and did not produce a significantly worse outcome than those with a normal or near-normal joint surface. The severity of the degeneration at any of the intra-articular locations also had no influence on outcome. We concluded that, provided there is not bone loss and grooving of the lateral facet, damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Oxford mobile-bearing unicompartmental knee replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 476 - 478
1 Apr 2011
Kang S Smith TO De Rover WBS Walton NP

There has been debate about the role of unicompartmental knee replacement in the presence of radiologically identifiable degenerative changes of the patellofemoral joint. We studied 195 knees in 163 patients in whom an Oxford unicompartmental knee replacement had been performed for medial osteoarthritis between January 2004 and July 2007. The mean age of the patients was 66 years (51 to 93). The degree of degenerative change of the patellofemoral joint was assessed using Jones’ criteria. Functional outcome was assessed at a mean of 3.4 years (2 to 7) post-operatively, using the Oxford knee score and the Short-form 12 score. Degenerative changes of the patellofemoral joint were seen pre-operatively in 125 knees (64%) on the skyline radiographs. There was no statistically significant difference in the Oxford knee or Short-form 12 scores between those patients who had patellofemoral osteoarthritis pre-operatively and those who did not (p = 0.22 and 0.54, respectively). These results support the opinion expressed at the designer’s hospital that degenerative changes of the patellofemoral joint in isolation should not be considered to be a contraindication to medial Oxford unicompartmental knee replacement


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1033 - 1040
1 Aug 2020
Kennedy JA Mohammad HR Yang I Mellon SJ Dodd CAF Pandit HG Murray DW

Aims. To report mid- to long-term results of Oxford mobile bearing domed lateral unicompartmental knee arthroplasty (UKA), and determine the effect of potential contraindications on outcome. Methods. A total of 325 consecutive domed lateral UKAs undertaken for the recommended indications were included, and their functional and survival outcomes were assessed. The effects of age, weight, activity, and the presence of full-thickness erosions of cartilage in the patellofemoral joint on outcome were evaluated. Results. Median follow-up was seven years (3 to 14), and mean age at surgery was 65 years (39 to 90). Median Oxford Knee Score (OKS) was 43 (interquartile range (IQR) 37 to 47), with 260 (80%) achieving a good or excellent score (OKS > 34). Revisions occurred in 34 (10%); 14 (4%) were for dislocation, of which 12 had no recurrence following insertion of a new bearing, and 12 (4%) were revised for medial osteoarthritis (OA). Ten-year survival was 85% (95% confidence interval (CI) 79 to 90, at risk 72). Age, weight, activity, and patellofemoral erosions did not have a significant effect on the clinical outcome or survival. Conclusion. Domed lateral UKA provides a good alternative to total knee arthroplasty (TKA) in the management of lateral compartment OA. Although dislocation is relatively easy to treat successfully, the dislocation rate of 4% is high. It is recommended that the stability of the bearing is assessed intraoperatively. If the bearing can easily be displaced, the fixed rather than the mobile bearing version of the Oxford lateral tibial component should be inserted instead. Younger age, heavier weight, high activity, and patellofemoral erosions did not detrimentally affect outcome, so should not be considered contraindications. Cite this article: Bone Joint J 2020;102-B(8):1033–1040


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1466 - 1470
1 Oct 2010
Didden K Luyckx T Bellemans J Labey L Innocenti B Vandenneucker H

The biomechanics of the patellofemoral joint can become disturbed during total knee replacement by alterations induced by the position and shape of the different prosthetic components. The role of the patella and femoral trochlea has been well studied. We have examined the effect of anterior or posterior positioning of the tibial component on the mechanisms of patellofemoral contact in total knee replacement. The hypothesis was that placing the tibial component more posteriorly would reduce patellofemoral contact stress while providing a more efficient lever arm during extension of the knee. We studied five different positions of the tibial component using a six degrees of freedom dynamic knee simulator system based on the Oxford rig, while simulating an active knee squat under physiological loading conditions. The patellofemoral contact force decreased at a mean of 2.2% for every millimetre of posterior translation of the tibial component. Anterior positions of the tibial component were associated with elevation of the patellofemoral joint pressure, which was particularly marked in flexion > 90°. From our results we believe that more posterior positioning of the tibial component in total knee replacement would be beneficial to the patellofemoral joint


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 475 - 480
1 Apr 2009
Matsumoto T Kuroda R Kubo S Muratsu H Mizuno K Kurosaka M

We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0°, 10°, 45°, 90° and 135° of flexion, with the patella both everted and reduced. While the measurement of the joint gap with a reduced patella in posterior-stabilised knees increased from extension to flexion, it remained constant for cruciate-retaining joints throughout a full range of movement. The joint gaps at deep knee flexion were significantly smaller for both types of prosthetic knee when the patellofemoral joint was reduced (p < 0.05)


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 709 - 716
1 Jun 2007
Mulford JS Wakeley CJ Eldridge JDJ

Chronic patellofemoral instability can be a disabling condition. Management of patients with this condition has improved owing to our increased knowledge of the functional anatomy of the patellofemoral joint. Accurate assessment of the underlying pathology in the unstable joint enables the formulation of appropriate treatment. The surgical technique employed in patients for whom non-operative management has failed should address the diagnosed abnormality. We have reviewed the literature on the stabilising features of the patellofemoral joint, the recommended investigations and the appropriate forms of treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1710 - 1716
1 Dec 2010
Chia W Pan R Tseng F Chen Y Feng C Lee H Chang D Sytwu H

The patellofemoral joint is an important source of symptoms in osteoarthritis of the knee. We have used a newly designed surgical model of patellar strengthening to induce osteoarthritis in BALB/c mice and to establish markers by investigating the relationship between osteoarthritis and synovial levels of matrix metalloproteinases (MMPs). Osteoarthritis was induced by using this microsurgical technique under direct vision without involving the cavity of the knee. Degeneration of cartilage was assessed by the Mankin score and synovial tissue was used to determine the mRNA expression levels of MMPs. Irrigation fluid from the knee was used to measure the concentrations of MMP-3 and MMP-9. Analysis of cartilage degeneration was correlated with the levels of expression of MMP. After operation the patellofemoral joint showed evidence of mild osteoarthritis at eight weeks and further degenerative changes by 12 weeks. The level of synovial MMP-9 mRNA correlated with the Mankin score at eight weeks, but not at 12 weeks. The levels of MMP-2, MMP-3 and MMP-14 mRNA correlated with the Mankin score at 12 weeks. An increase in MMP-3 was observed from four weeks up to 16 weeks. MMP-9 was notably increased at eight weeks, but the concentration at 16 weeks had decreased to the level observed at four weeks. Our observations suggest that MMP-2, MMP-3 and MMP-14 could be used as markers of the progression of osteoarthritic change


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 622 - 628
1 May 2011
Pandit H Jenkins C Gill HS Smith G Price AJ Dodd CAF Murray DW

The contraindications for unicompartmental knee replacement (UKR) remain controversial. The views of many surgeons are based on Kozinn and Scott’s 1989 publication which stated that patients who weighed more than 82 kg, were younger than 60 years, undertook heavy labour, had exposed bone in the patellofemoral joint or chondrocalcinosis, were not ideal candidates for UKR. Our aim was to determine whether these potential contraindications should apply to patients with a mobile-bearing UKR. In order to do this the outcome of patients with these potential contraindications was compared with that of patients without the contraindications in a prospective series of 1000 UKRs. The outcome was assessed using the Oxford knee score, the American Knee Society score, the Tegner activity score, revision rate and survival. The clinical outcome of patients with each of the potential contraindications was similar to or better than those without each contraindication. Overall, 678 UKRs (68%) were performed in patients who had at least one potential contraindication and only 322 (32%) in patients deemed to be ideal. The survival at ten years was 97.0% (95% confidence interval 93.4 to 100.0) for those with potential contraindications and 93.6% (95% confidence interval 87.2 to 100.0) in the ideal patients. We conclude that the thresholds proposed by Kozinn and Scott using weight, age, activity, the state of the patellofemoral joint and chondrocalcinosis should not be considered to be contraindications for the use of the Oxford UKR


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 43 - 49
1 Jan 2008
Smith AJ Wood DJ Li M

We have examined the differences in clinical outcome of total knee replacement (TKR) with and without patellar resurfacing in a prospective, randomised study of 181 osteoarthritic knees in 142 patients using the Profix total knee system which has a femoral component with features considered to be anatomical and a domed patellar implant. The procedures were carried out between February 1998 and November 2002. A total of 159 TKRs in 142 patients were available for review at a mean of four years (3 to 7). The patients and the clinical evaluator were blinded in this prospective study. Evaluation was undertaken annually by an independent observer using the knee pain scale and the Knee Society clinical rating system. Specific evaluation of anterior knee pain, stair-climbing and rising from a seated to a standing position was also undertaken. No benefit was shown of TKR with patellar resurfacing over that without resurfacing with respect to any of the measured outcomes. In 22 of 73 knees (30.1%) with and 18 of 86 knees (20.9%) without patellar resurfacing there was some degree of anterior knee pain (p = 0.183). No revisions related to the patellofemoral joint were performed in either group. Only one TKR in each group underwent a re-operation related to the patellofemoral joint. A significant association between knee flexion contracture and anterior knee pain was observed in those knees with patellar resurfacing (p = 0.006)


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 255 - 260
1 Mar 1985
Nakamura N Ellis M Seedhom B

The effects of advancement of the tibial tuberosity by inserting bony wedges was studied on cadaveric specimens of the knee. The geometry, the contact areas and the forces acting on the patellofemoral joint were investigated, and the forces acting on the tibiofemoral compartment were calculated. A 1 cm advancement was found to be optimal in reducing the high patellofemoral joint forces occurring at 90 degrees and 110 degrees of flexion, whilst causing least reduction of the contact areas; the stresses on the joint were reduced significantly. Advancement by 2 cm and by 3 cm drastically reduced the congruity and the size of the contact area. It was also shown that 2 cm and 3 cm advancement caused an increase in forces at the patellofemoral joint and also in the tibiofemoral joint in a direction tangential to the articular surfaces


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1331 - 1335
1 Oct 2006
von Knoch F Böhm T Bürgi ML von Knoch M Bereiter H

We investigated the clinical and radiological outcome of trochleaplasty for recurrent patellar dislocation in association with trochlear dysplasia in 38 consecutive patients (45 knees) with a mean follow-up of 8.3 years (4 to 14). None had recurrence of dislocation after trochleaplasty. Post-operatively, patellofemoral pain, present pre-operatively in only 35 knees, became worse in 15 (33.4%), remained unchanged in four (8.8%) and improved in 22 (49%). Four knees which had no pain pre-operatively (8.8%) continued to have no pain. A total of 33 knees were available for radiological assessment. Post-operatively, all but two knees (93.9%) had correction of trochlear dysplasia radiologically but degenerative changes of the patellofemoral joint developed in 30% (10) of the knees. We conclude that recurrent patellar dislocation associated with trochlear dysplasia can be treated successfully by trochleaplasty, but the impact on patellofemoral pain and the development of patellofemoral osteoarthritis is less predictable. Overall, subjective patient satisfaction with restored patellofemoral stability after trochleaplasty appeared to outweigh its possible sequelae


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims

Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.

Methods

This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims

This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height.

Methods

Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1591 - 1595
1 Dec 2006
Price AJ Oppold PT Murray DW Zavatsky AB

The Oxford medial unicompartmental knee replacement was designed to reproduce normal mobility and forces in the knee, but its detailed effect on the patellofemoral joint has not been studied previously. We have examined the effect on patellofemoral mechanics of the knee by simultaneously measuring patellofemoral kinematics and forces in 11 cadaver knee specimens in a supine leg-extension rig. Comparison was made between the intact normal knee and sequential unicompartmental and total knee replacement. Following medial mobile-bearing unicompartmental replacement in 11 knees, patellofemoral kinematics and forces did not change significantly from those in the intact knee across any measured parameter. In contrast, following posterior cruciate ligament retaining total knee replacement in eight knees, there were significant changes in patellofemoral movement and forces. The Oxford device appears to produce near-normal patellofemoral mechanics, which may partly explain the low incidence of complications with the extensor mechanism associated with clinical use


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1348 - 1354
1 Oct 2011
Vanbiervliet J Bellemans J Verlinden C Luyckx J Labey L Innocenti B Vandenneucker H

Complications involving the patellofemoral joint, caused by malrotation of the femoral component during total knee replacement, are an important cause of persistent pain and failure leading to revision surgery. The aim of this study was to determine and quantify the influence of femoral component malrotation on patellofemoral wear, and to determine whether or not there is a difference in the rate of wear of the patellar component when articulated against oxidised zirconium (OxZr) and cobalt-chrome (CoCr) components. An in vitro method was used to simulate patellar maltracking for both materials. Both rates of wear and changes in height on the patellar articular surface were measured. The mean rates of wear measured were very small compared to standard tibiofemoral wear rates. When data for each femoral component material were pooled, the mean rate of wear was 0.19 mm. 3. /Mcycle (. sd. 0.21) for OxZr and 0.34 mm. 3. /Mcycle (. sd. 0.335) for CoCr. The largest change in height on each patella varied from -0.05 mm to -0.33 mm over the different configurations. The results suggest that patellar maltracking due to an internally rotated femoral component leads to an increased mean patellar wear. Although not statistically significant, the mean wear production may be lower for OxZr than for CoCr components


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1081 - 1084
1 Aug 2005
Han I Chang CB Lee S Lee MC Seong SC Kim TK

We sought to determine the degree of correlation between the condition of the patellar articular cartilage and patellofemoral symptoms and function in osteoarthritic patients undergoing total knee arthroplasty. The depth of the osteoarthritic lesion, as graded by the Outerbridge classification and its size and location were assessed to determine the condition of the patellar cartilage in 80 consecutive osteoarthritic knees undergoing total knee arthroplasty. The association between the condition of the cartilage and patellofemoral symptoms and function was investigated by correlation analysis. The depth and size of the lesion had a significant but weak correlation with anterior knee pain (r = −0.300 and −0.289; p = 0.007 and 0.009, respectively), whereas location had no significant association (p > 0.05). None had a significant association with patellofemoral functional parameters (chair-rising, stair-climbing, and quadriceps power) (p > 0.05). Our study indicates that patellofemoral symptoms and function are not completely determined by the condition of the cartilage. Caution should be taken when the symptoms and functional limitations are attributed to a lesion in the patellofemoral joint in making a decision regarding patellar resurfacing in total knee arthroplasty


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1235 - 1238
1 Dec 2023
Kader DF Jones S Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1259 - 1264
1 Dec 2023
Hurley ET Hughes AJ Savage-Elliott I Dejour D Campbell KA Mulcahey MK Wittstein JR Jazrawi LM

Aims

The aim of this study was to establish consensus statements on the diagnosis, nonoperative management, and indications, if any, for medial patellofemoral complex (MPFC) repair in patients with patellar instability, using the modified Delphi approach.

Methods

A total of 60 surgeons from 11 countries were invited to develop consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest within patellar instability. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered to be unanimous.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1265 - 1270
1 Dec 2023
Hurley ET Sherman SL Chahla J Gursoy S Alaia MJ Tanaka MJ Pace JL Jazrawi LM

Aims

The aim of this study was to establish consensus statements on medial patellofemoral ligament (MPFL) reconstruction, anteromedialization tibial tubercle osteotomy, trochleoplasty, and rehabilitation and return to sporting activity in patients with patellar instability, using the modified Delphi process.

Methods

This was the second part of a study dealing with these aspects of management in these patients. As in part I, a total of 60 surgeons from 11 countries contributed to the development of consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered unanimous.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 235 - 239
1 Mar 1997
Takahashi T Wada Y Yamamoto H

We measured the pressure distribution across the tibiofemoral and patellofemoral joints during total knee arthroplasty (TKA) using Fuji pressure-sensitive film (Prescale) in 51 patients (63 joints) comparing the results with those in 21 patients in whom Prescale was not used. We classified the stress-distribution patterns in the tibiofemoral joints into four types: normal, varus-valgus instability, rotational malalignment, and a combination of instability and malrotation. The medial ligaments were then released according to the information obtained from these patterns. The conformity ratio of the contact area between repeated trials was 87.0%. Pressure distribution across the patellofemoral joints was also considered. There was a significant decrease in the mean valgus stress angle in the Prescale group compared with the control group (p < 0.01). Release of the lateral retinaculum according to the results showed no significant differences in subluxation of the patella between the released group and the group which did not appear to need this procedure


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 269 - 276
1 Mar 2023
Tay ML Monk AP Frampton CM Hooper GJ Young SW

Aims

Unicompartmental knee arthroplasty (UKA) has higher revision rates than total knee arthroplasty (TKA). As revision of UKA may be less technically demanding than revision TKA, UKA patients with poor functional outcomes may be more likely to be offered revision than TKA patients with similar outcomes. The aim of this study was to compare clinical thresholds for revisions between TKA and UKA using revision incidence and patient-reported outcomes, in a large, matched cohort at early, mid-, and late-term follow-up.

Methods

Analyses were performed on propensity score-matched patient cohorts of TKAs and UKAs (2:1) registered in the New Zealand Joint Registry between 1 January 1999 and 31 December 2019 with an Oxford Knee Score (OKS) response at six months (n, TKA: 16,774; UKA: 8,387), five years (TKA: 6,718; UKA: 3,359), or ten years (TKA: 3,486; UKA: 1,743). Associations between OKS and revision within two years following the score were examined. Thresholds were compared using receiver operating characteristic analysis. Reasons for aseptic revision were compared using cumulative incidence with competing risk.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 622 - 634
1 Jun 2023
Simpson CJRW Wright E Ng N Yap NJ Ndou S Scott CEH Clement ND

Aims

This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of anterior knee pain, knee-specific patient-reported outcome measures, complication rates, and reoperation rates.

Methods

A systematic review of MEDLINE, PubMed, and Google Scholar was performed to identify randomized controlled trials (RCTs) according to search criteria. Search terms used included: arthroplasty, replacement, knee (Mesh), TKA, prosthesis, patella, patellar resurfacing, and patellar retaining. RCTs that compared patellar resurfacing versus unresurfaced in primary TKA were included for further analysis. Studies were evaluated using the Scottish Intercollegiate Guidelines Network assessment tool for quality and minimization of bias. Data were synthesized and meta-analysis performed.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims

This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults.

Methods

This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 996 - 1000
1 Sep 2000
Weale AE Murray DW Baines J Newman JH

Failure of a unicompartmental knee replacement (UKR) may be caused by progressive osteoarthritis of the knee and/or failure of the prosthesis. Limb alignment can influence both of these factors. We have examined the fate of the other compartments and measured changes in leg alignment after UKR. A total of 50 UKRs was carried out on 45 carefully selected patients between 1989 and 1992. At operation, deliberate attempts were made to avoid overcorrection of the deformity. Four patients died, one patient was lost to follow-up and two knees were revised before review which was at a minimum of five years. Standard long-leg weight-bearing anteroposterior views of the knee and skyline views of the patellofemoral joint were taken before and at eight months and five years after operation. The radiographs of the remaining 43 knees were reviewed twice by blind and randomised assessment to measure the progression of osteoarthritis within the joints. Overcorrection of the deformity in the coronal plane was avoided in all but two knees. Only one showed evidence of progression of osteoarthritis within the patellofemoral joint, and this was only identified in one of the four assessments. Deterioration in the state of the opposite tibiofemoral compartment was not seen. Varus deformity tended to recur. Recurrent varus of 2° was observed between eight months and five years after operation. There was no correlation between the postoperative tibiofemoral angle and the extent of recurrent varus recorded at five years. Changes in alignment may be indicative of minor polyethylene wear or of subsidence of the tibial component. The incidence of progressive osteoarthritis within the knee was very low after UKR. Patients should be carefully selected and overcorrection of the deformity be avoided


Aims

The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery.

Methods

A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 840 - 845
1 May 2021
Rossi SMP Perticarini L Clocchiatti S Ghiara M Benazzo F

Aims

In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up.

Methods

A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1561 - 1570
1 Oct 2021
Blyth MJG Banger MS Doonan J Jones BG MacLean AD Rowe PJ

Aims

The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively.

Methods

A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1514 - 1525
1 Sep 2021
Scott CEH Holland G Gillespie M Keenan OJ Gherman A MacDonald DJ Simpson AHRW Clement ND

Aims

The aims of this study were to investigate the ability to kneel after total knee arthroplasty (TKA) without patellar resurfacing, and its effect on patient-reported outcome measures (PROMs). Secondary aims included identifying which kneeling positions were most important to patients, and the influence of radiological parameters on the ability to kneel before and after TKA.

Methods

This prospective longitudinal study involved 209 patients who underwent single radius cruciate-retaining TKA without patellar resurfacing. Preoperative EuroQol five-dimension questionnaire (EQ-5D), Oxford Knee Score (OKS), and the ability to achieve four kneeling positions were assessed including a single leg kneel, a double leg kneel, a high-flexion kneel, and a praying position. The severity of radiological osteoarthritis (OA) was graded and the pattern of OA was recorded intraoperatively. The flexion of the femoral component, posterior condylar offset, and anterior femoral offset were measured radiologically. At two to four years postoperatively, 151 patients with a mean age of 70.0 years (SD 9.44) were included. Their mean BMI was 30.4 kg/m2 (SD 5.36) and 60 were male (40%). They completed EQ-5D, OKS, and Kujala scores, assessments of the ability to kneel, and a visual analogue scale for anterior knee pain and satisfaction.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 339 - 343
1 Mar 2012
Sewell MD Hanna SA Al-Khateeb H Miles J Pollock RC Carrington RWJ Skinner JA Cannon SR Briggs TWR

Patients with skeletal dysplasia are prone to developing advanced osteoarthritis of the knee requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure owing to the deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We retrospectively reviewed the outcome of 11 TKRs performed in eight patients with skeletal dysplasia at our institution using the Stanmore Modular Individualised Lower Extremity System (SMILES) custom-made rotating-hinge TKR. There were three men and five women with mean age of 57 years (41 to 79). Patients were followed clinically and radiologically for a mean of seven years (3 to 11.5). The mean Knee Society clinical and function scores improved from 24 (14 to 36) and 20 (5 to 40) pre-operatively, respectively, to 68 (28 to 80) and 50 (22 to 74), respectively, at final follow-up. Four complications were recorded, including a patellar fracture following a fall, a tibial peri-prosthetic fracture, persistent anterior knee pain, and aseptic loosening of a femoral component requiring revision. Our results demonstrate that custom primary rotating-hinge TKR in patients with skeletal dysplasia is effective at relieving pain, with a satisfactory range of movement and improved function. It compensates for bony deformity and ligament deficiency and reduces the likelihood of corrective osteotomy. Patellofemoral joint complications are frequent and functional outcome is worse than with primary TKR in the general population


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 861 - 864
1 Aug 2002
Nakagawa K Wada Y Minamide M Tsuchiya A Moriya H

We examined an39 patients (45 knees) who had undergone Elmslie-Trillat procedure for recurrent or habitual dislocation of the patella with a follow-up of more than ten years. The mean age at the time of surgery was 18.4 years; the mean follow-up was 161 months (120 to 238). Using Fulkerson’s functional knee score, 41 knees (91%) had an excellent or good result at a mean follow-up of 45 months, and this was maintained in 29 (64%) at the final review. The main cause of deterioration in the clinical results was the onset or worsening of patellofemoral joint pain, not patellar instability


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 797 - 803
1 Nov 1987
Katz M Hungerford D

Thirty-six patients with reflex sympathetic dystrophy primarily affecting the knee were reviewed. Injuries or operation about the patellofemoral joint triggered its onset in 64% of patients. Co-existent mechanical derangement of the knee was present in 64% of patients. Those patients who underwent sympathetic blockade or sympathectomy within one year of onset of symptoms had significantly better pain and function scores than those in whom intervention was later. Early diagnosis remains the key to successful management. Surgery for co-existent mechanical derangement in the affected knee should not be performed until the syndrome is controlled


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 435 - 442
1 Nov 1979
Sikorski J Peters J Watt I

A new radiological technique is presented in which serial axial radiographs of the patellofemoral joints are taken under conditions in which the muscles about the knee and hip are contracted in a manner similar to that during weight-bearing. A form of analysis has been developed whereby patellar rotation can be measured in two planes and femoral rotation about its long axis inferred. A population of asymptomatic adults and children was investigated in this way and their results (regarded as normal) compared with those in fifteen children with idiopathic chondromalacia patellae. In the normal child the femur rotates medially with the onset of muscle activity; by contrast the children with chondromalacia show a reversal of this mechanism


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 296 - 299
1 Mar 1989
Macdonald D Hutton J Kelly I

We assessed patellofemoral joint function by combining the measurement of maximal isometric extensor torque at the knee with clinical and radiological measurements in order to calculate the patellofemoral contact force. Eighteen volunteers established the normal ranges of results and the reliability of the system. Of the 39 patients with a variety of knee problems, 29 had anterior knee pain, and all had a subsequent arthroscopy. Patients with anterior knee pain and lesions in the patellar cartilage had significantly reduced isometric contact forces, but those with normal patellofemoral cartilage had normal contact forces. Our method may be useful in providing an objective assessment of anterior knee pain and a quantitative means of monitoring its treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 117 - 120
1 Jan 1986
Soudry M Lanir A Angel D Roffman M Kaplan N Mendes D

Nuclear magnetic resonance imaging (MRI) was used to study the normal knee. As well as revealing bone quality, MRI provided useful information on intra-articular and extra-articular soft tissues. Midsagittal views gave clear images of the cruciate ligaments, and of the patellar and quadriceps tendons. Parasagittal views were the best for delineating the menisci which, like ligaments and tendons, are of low intensity; the semimembranosus tendon and its insertion to the proximal tibia were also seen clearly in these views. The cruciate ligaments and menisci, though visible in the coronal view also, were better seen in the sagittal view. Axial views provided information on the structure of the patella, its cartilage, the patellofemoral joint and posterior soft-tissue structures


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 685 - 693
1 Nov 1984
Fairbank J Pynsent P van Poortvliet J Phillips H

Mechanical abnormalities of the patellofemoral joint are among the many causes that have been suggested for adolescent knee pain. This study seeks to identify these factors. Measurements of joint mobility and lower limb morphology were made on 446 pupils at a comprehensive school, 136 of whom had suffered knee pain in the previous year. The pupils with symptoms enjoyed sporting activities significantly more than their symptom-free contemporaries. Joint mobility, the Q-angle, genu valgum and anteversion of the femoral neck were not significantly different between those pupils with and those without anterior knee pain. Data on lower limb morphology of normal adolescents are presented. Examination of 52 hospital outpatients aged 13 to 36 years with anterior knee pain produced results comparable with those for the pupils. It is concluded that chronic overloading, rather than faulty mechanics, is the dominant factor in the genesis of anterior knee pain in adolescent patients


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 625 - 631
1 Jul 1999
Peltonen J Vaara P Marttinen E Ryöppy S Poussa M

We examined clinically and radiologically the knees of 46 patients (27 females and 19 males) with diastrophic dysplasia. The age of the patients varied from newborn to 38 years. A total of 18 patients was followed during their growth until adolescence. The knees of two legally aborted fetuses appeared on examination to be macroscopically normal and congruous. Excessive valgus deformity of the tibiofemoral weight-bearing angle with a mean of 14° was noted in infancy. Most of the patients had marked instability of the knees. The range of movement of the knee began to decrease before the age of five years. There were signs of early degeneration and deformation of the bony epiphyses before the age of six years. The patellofemoral joint was abnormal from an early age. A marked patella infera, often associated with a lateral position of the patella with bony fragmentation, was noted. The knee in diastrophic dysplasia is basically unstable, showing early deformation of the subchondral bone and degeneration of the joint


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 900 - 906
1 Sep 1998
Miller RK Goodfellow JW Murray DW O’Connor JJ

Using a new, non-invasive method, we measured the patellofemoral force (PFF) in cadaver knees mounted in a rig to simulate weight-bearing. The PFF was measured from 20° to 120° of flexion before and after implanting three designs of knee prosthesis. Medial unicompartmental arthroplasty with a meniscal-bearing prosthesis and with retention of both cruciate ligaments caused no significant change in the PFF. After arthroplasty with a posterior-cruciate-retaining prosthesis and division of the anterior cruciate ligament, the PFF decreased in extension and increased by 20% in flexion. Implantation of a posterior stabilised prosthesis and division of both cruciate ligaments produced a decrease in the PFF in extension but maintained normal load in flexion. There was a direct relationship between the PFF and the angle made with the patellar tendon and the long axis of the tibia. The abnormalities of the patellar tendon angle which resulted from implantation of the two total prostheses explain the observed changes in the PFF and show how the mechanics of the patellofemoral joint depend upon the kinematics of the tibiofemoral articulation


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 822 - 827
1 May 2021
Buzzatti L Keelson B Vanlauwe J Buls N De Mey J Vandemeulebroucke J Cattrysse E Scheerlinck T

Evaluating musculoskeletal conditions of the lower limb and understanding the pathophysiology of complex bone kinematics is challenging. Static images do not take into account the dynamic component of relative bone motion and muscle activation. Fluoroscopy and dynamic MRI have important limitations. Dynamic CT (4D-CT) is an emerging alternative that combines high spatial and temporal resolution, with an increased availability in clinical practice. 4D-CT allows simultaneous visualization of bone morphology and joint kinematics. This unique combination makes it an ideal tool to evaluate functional disorders of the musculoskeletal system. In the lower limb, 4D-CT has been used to diagnose femoroacetabular impingement, patellofemoral, ankle and subtalar joint instability, or reduced range of motion. 4D-CT has also been used to demonstrate the effect of surgery, mainly on patellar instability. 4D-CT will need further research and validation before it can be widely used in clinical practice. We believe, however, it is here to stay, and will become a reference in the diagnosis of lower limb conditions and the evaluation of treatment options.

Cite this article: Bone Joint J 2021;103-B(5):822–827.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 788 - 792
1 Nov 1989
Kujala U Osterman K Kormano M Nelimarkka O Hurme M Taimela S

Magnetic resonance imaging was used to analyse the patellofemoral relationships during the first 30 degrees of knee flexion in women with recurrent patellar dislocation. The patellofemoral joints were imaged both sagittally and axially with the knee flexed 0 degrees, 10 degrees, 20 degrees, and 30 degrees. At the beginning of knee flexion the sulcus angle was greater than in unaffected women, the lateral patellofemoral angle was smaller, the patella displaced further laterally, tilted more laterally and the congruence angle was directed more laterally. At 30 degrees of knee flexion these differences were less marked than at 0 degree to 10 degrees. Logistic regression analysis showed that the sulcus angle at 10 degrees of knee flexion was the most diagnostic feature, indicating that there is an anatomical predisposition to recurrent dislocation and that pathological patellar tracking starts from the beginning of flexion. Traditional sunrise radiographic films taken at 25 degrees to 30 degrees knee flexion clearly miss diagnostically important information


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 716 - 726
1 Jun 2020
Scott CEH Holland G Krahelski O Murray IR Keating JF Keenan OJF

Aims

This study aims to determine the proportion of patients with end-stage knee osteoarthritis (OA) possibly suitable for partial (PKA) or combined partial knee arthroplasty (CPKA) according to patterns of full-thickness cartilage loss and anterior cruciate ligament (ACL) status.

Methods

A cross-sectional analysis of 300 consecutive patients (mean age 69 years (SD 9.5, 44 to 91), mean body mass index (BMI) 30.6 (SD 5.5, 20 to 53), 178 female (59.3%)) undergoing total knee arthroplasty (TKA) for Kellgren-Lawrence grade ≥ 3 knee OA was conducted. The point of maximal tibial bone loss on preoperative lateral radiographs was determined as a percentage of the tibial diameter. At surgery, Lachman’s test and ACL status were recorded. The presence of full-thickness cartilage loss within 16 articular surface regions (two patella, eight femoral, six tibial) was recorded.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 301 - 309
1 Mar 2020
Keenan OJF Holland G Maempel JF Keating JF Scott CEH

Aims

Although knee osteoarthritis (OA) is diagnosed and monitored radiologically, actual full-thickness cartilage loss (FTCL) has rarely been correlated with radiological classification. This study aims to analyze which classification system correlates best with FTCL and to assess their reliability.

Methods

A prospective study of 300 consecutive patients undergoing unilateral total knee arthroplasty (TKA) for OA (mean age 69 years (44 to 91; standard deviation (SD) 9.5), 178 (59%) female). Two blinded examiners independently graded preoperative radiographs using five common systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlbäck. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC). Intraoperatively, anterior cruciate ligament (ACL) status and the presence of FTCL in 16 regions of interest were recorded. Radiological classification and FTCL were correlated using the Spearman correlation coefficient.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1108 - 1108
1 Aug 2020
Burger JA Dooley MS Kleeblad LJ Zuiderbaan HA Pearle AD


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 426 - 433
1 Apr 2020
Boettner F Sculco P Faschingbauer M Rueckl K Windhager R Kasparek MF

Aims

To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps.

Methods

In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims

Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design.

Methods

Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m2 (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 91 - 95
1 Jun 2020
Johnson, Jr. WB Engh, Jr. CA Parks NL Hamilton WG Ho PH Fricka KB

Aims

It has been hypothesized that a unicompartmental knee arthroplasty (UKA) is more likely to be revised than a total knee arthroplasty (TKA) because conversion surgery to a primary TKA is a less complicated procedure. The purpose of this study was to determine if there is a lower threshold for revising a UKA compared with TKA based on Oxford Knee Scores (OKSs) and range of movement (ROM) at the time of revision.

Methods

We retrospectively reviewed 619 aseptic revision cases performed between December 1998 and October 2018. This included 138 UKAs that underwent conversion to TKA and 481 initial TKA revisions. Age, body mass index (BMI), time in situ, OKS, and ROM were available for all patients.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 108 - 116
1 Jan 2020
Burger JA Kleeblad LJ Laas N Pearle AD

Aims

Limited evidence is available on mid-term outcomes of robotic-arm assisted (RA) partial knee arthroplasty (PKA). Therefore, the purpose of this study was to evaluate mid-term survivorship, modes of failure, and patient-reported outcomes of RA PKA.

Methods

A retrospective review of patients who underwent RA PKA between June 2007 and August 2016 was performed. Patients received a fixed-bearing medial or lateral unicompartmental knee arthroplasty (UKA), patellofemoral arthroplasty (PFA), or bicompartmental knee arthroplasty (BiKA; PFA plus medial UKA). All patients completed a questionnaire regarding revision surgery, reoperations, and level of satisfaction. Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed using the KOOS for Joint Replacement Junior survey.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 325 - 330
1 Mar 2019
Balcarek P Zimmermann F

Aims

The aim of this study was to evaluate cartilaginous patellotrochlear congruence and patellofemoral alignment parameters after deepening trochleoplasty in severe trochlear dysplasia.

Patients and Methods

The study group comprised 20 patients (two male, 18 female; mean age 24 years (16 to 39)) who underwent deepening trochleoplasty and medial patellofemoral ligament (MPFL) reconstruction for the treatment of recurrent lateral patellar dislocation due to severe trochlear dysplasia (Dejour type B to D). Pre- and postoperative MRI investigations of the study group were compared with MRI data of 20 age- and gender-matched control patients (two male, 18 female; mean age 27 years (18 to 44)) regarding the patellotrochlear contact ratio, patellotrochlear contact area, posterior patellar edge-trochlear groove ratio, and patellar tilt.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1168 - 1176
1 Sep 2019
Calder PR McKay JE Timms AJ Roskrow T Fugazzotto S Edel P Goodier WD

Aims

The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients.

Patients and Methods

A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications.


Aims

The aim is to assess the cost-effectiveness of patellofemoral arthroplasty (PFA) in comparison with total knee arthroplasty (TKA) for the treatment of isolated patellofemoral osteoarthritis (OA) based on prospectively collected data on health outcomes and resource use from a blinded, randomized, clinical trial.

Methods

A total of 100 patients with isolated patellofemoral osteoarthritis were randomized to receive either PFA or TKA by experienced knee surgeons trained in using both implants. Patients completed patient-reported outcomes including EuroQol five-dimension questionnaire (EQ-5D) and 6-Item Short-Form Health Survey questionnaire (SF-6D) before the procedure. The scores were completed again after six weeks, three, six, and nine months, and again after one- and two-year post-surgery and yearly henceforth. Time-weighted outcome measures were constructed. Cost data were obtained from clinical registrations and patient-reported questionnaires. Incremental gain in health outcomes (quality-adjusted life-years (QALYs)) and incremental costs were compared for the two groups of patients. Net monetary benefit was calculated assuming a threshold value of €10,000, €35,000, and €50,000 per QALY and used to test the statistical uncertainty and central assumptions about outcomes and costs.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 310 - 318
1 Mar 2020
Joseph MN Achten J Parsons NR Costa ML

Aims

A pragmatic, single-centre, double-blind randomized clinical trial was conducted in a NHS teaching hospital to evaluate whether there is a difference in functional knee scores, quality-of-life outcome assessments, and complications at one-year after intervention between total knee arthroplasty (TKA) and patellofemoral arthroplasty (PFA) in patients with severe isolated patellofemoral arthritis.

Methods

This parallel, two-arm, superiority trial was powered at 80%, and involved 64 patients with severe isolated patellofemoral arthritis. The primary outcome measure was the functional section of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score at 12 months. Secondary outcomes were the full 24-item WOMAC, Oxford Knee Score (OKS), American Knee Society Score (AKSS), EuroQol five dimension (EQ-5D) quality-of-life score, the University of California, Los Angeles (UCLA) Physical Activity Rating Scale, and complication rates collected at three, six, and 12 months. For longer-term follow-up, OKS, EQ-5D, and self-reported satisfaction score were collected at 24 and 60 months.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 811 - 821
1 Jun 2018
Fu K Duan G Liu C Niu J Wang F

Aims

The aim of this study was to investigate the changes in femoral trochlear morphology following surgical correction of recurrent patellar dislocation associated with trochlear dysplasia in children.

Patients and Methods

A total of 23 patients with a mean age of 9.6 years (7 to 11) were included All had bilateral recurrent patellar dislocation associated with femoral trochlear dysplasia. The knee with traumatic dislocation at the time of presentation or that had dislocated most frequently was treated with medial patellar retinacular plasty (Group S). The contralateral knee served as a control and was treated conservatively (Group C). All patients were treated between October 2008 and August 2013. The mean follow-up was 48.7 months (43 to 56). Axial CT scans were undertaken in all patients to assess the trochlear morphological characteristics on a particular axial image which was established at the point with the greatest epicondylar width based on measurements preoperatively and at the final follow-up.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1162 - 1167
1 Sep 2018
Metcalfe AJ Ahearn N Hassaballa MA Parsons N Ackroyd CE Murray JR Robinson JR Eldridge JD Porteous AJ

Aims

This study reports on the medium- to long-term implant survivorship and patient-reported outcomes for the Avon patellofemoral joint (PFJ) arthroplasty.

Patients and Methods

A total of 558 Avon PFJ arthroplasties in 431 patients, with minimum two-year follow-up, were identified from a prospective database. Patient-reported outcomes and implant survivorship were analyzed, with follow-up of up to 18 years.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1058 - 1062
1 Sep 2019
van Kuijk KSR Reijman M Bierma-Zeinstra SMA Waarsing JH Meuffels DE

Aims

Little is known about the risk factors that predispose to a rupture of the posterior cruciate ligament (PCL). Identifying risk factors is the first step in trying to prevent a rupture of the PCL from occurring. The morphology of the knee in patients who rupture their PCL may differ from that of control patients. The purpose of this study was to identify any variations in bone morphology that are related to a PCL.

Patients and Methods

We compared the anteroposterior (AP), lateral, and Rosenberg view radiographs of 94 patients with a ruptured PCL to a control group of 168 patients matched by age, sex, and body mass index (BMI), but with an intact PCL after a knee injury. Statistical shape modelling software was used to assess the shape of the knee and determine any difference in anatomical landmarks.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 922 - 928
1 Aug 2019
Garner A van Arkel RJ Cobb J

Aims

There has been a recent resurgence in interest in combined partial knee arthroplasty (PKA) as an alternative to total knee arthroplasty (TKA). The varied terminology used to describe these procedures leads to confusion and ambiguity in communication between surgeons, allied health professionals, and patients. A standardized classification system is required for patient safety, accurate clinical record-keeping, clear communication, correct coding for appropriate remuneration, and joint registry data collection.

Materials and Methods

An advanced PubMed search was conducted, using medical subject headings (MeSH) to identify terms and abbreviations used to describe knee arthroplasty procedures. The search related to TKA, unicompartmental (UKA), patellofemoral (PFA), and combined PKA procedures. Surveys were conducted of orthopaedic surgeons, trainees, and biomechanical engineers, who were asked which of the descriptive terms and abbreviations identified from the literature search they found most intuitive and appropriate to describe each procedure. The results were used to determine a popular consensus.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA.

Patients and Methods

In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 838 - 847
1 Jul 2019
Robinson PG Clement ND Hamilton D Blyth MJG Haddad FS Patton JT

Aims

Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used.

Materials and Methods

A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 432 - 435
1 Apr 2018
Murray DW Parkinson RW

Unicompartmental knee arthroplasty (UKA) has numerous advantages over total knee arthroplasty (TKA) and one disadvantage, the higher revision rate. The best way to minimize the revision rate is for surgeons to use UKA for at least 20% of their knee arthroplasties. To achieve this, they need to learn and apply the appropriate indications and techniques. This would decrease the revision rate and increase the number of UKAs which were implanted, which would save money and patients would benefit from improved outcomes over their lifetime.

Cite this article: Bone Joint J 2018;100-B:432–5.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims

The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal.

Patients and Methods

A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 331 - 339
1 Mar 2019
McEwen P Balendra G Doma K

Aims

The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases?

Patients and Methods

A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 41 - 46
1 Jan 2019
Clement ND Howard TA Immelman RJ MacDonald D Patton JT Lawson GM Burnett R

Aims

The primary aim of this study was to compare the knee-specific functional outcome of patellofemoral arthroplasty with total knee arthroplasty (TKA) in the management of patients with patellofemoral osteoarthritis.

Patients and Methods

A total of 54 consecutive Avon patellofemoral arthroplasties were identified and propensity-score-matched to a group of 54 patients undergoing a TKA with patellar resurfacing for patellofemoral osteoarthritis. The Oxford Knee Score (OKS), the 12-Item Short-Form Health Survey (SF-12), and patient satisfaction were collected at a mean follow up of 9.2 years (8 to 15). Survival was defined by revision or intention to revise.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 11 - 15
1 Oct 2016
Konan S Haddad FS

Aims

Medial unicompartmental knee arthroplasty (UKA) is associated with successful outcomes in carefully selected patient cohorts. We hypothesised that severity and location of patellofemoral cartilage lesions significantly influences functional outcome after Oxford medial compartmental knee arthroplasty.

Patients and Methods

We reviewed 100 consecutive UKAs at minimum eight-year follow-up (96 to 132). A single surgeon performed all procedures. Patients were selected based on clinical and plain radiographic assessment. All patients had end-stage medial compartment osteoarthritis (OA) with sparing of the lateral compartment and intact anterior cruciate ligaments. None of the patients had end-stage patellofemoral OA, but patients with anterior knee pain or partial thickness chondral loss were not excluded. There were 57 male and 43 female patients. The mean age at surgery was 69 years (41 to 82). At surgery the joint was carefully inspected for patellofemoral chondral loss and this was documented based on severity of cartilage loss (0 to 4 Outerbridge grading) and topographic location (medial, lateral, central, and superior or inferior). Functional scores collected included Oxford Knee Score (OKS), patient satisfaction scale and University College Hospital (UCH) knee score. Intraclass correlation was used to compare chondral damage to outcomes.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 41 - 47
1 Oct 2016
Lisowski LA Meijer LI Bekerom MPJVD Pilot P Lisowski AE

Aims

The interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has increased rapidly but the long-term follow-up of the Oxford UKAs has yet to be analysed in non-designer centres. We have examined our ten- to 15-year clinical and radiological follow-up data for the Oxford Phase III UKAs.

Patients and Methods

Between January 1999 and January 2005 a total of 138 consecutive Oxford Phase III arthroplasties were performed by a single surgeon in 129 patients for medial compartment osteoarthritis (71 right and 67 left knees, mean age 72.0 years (47 to 91), mean body mass index 28.2 (20.7 to 52.2)). Both clinical data and radiographs were prospectively recorded and obtained at intervals. Of the 129 patients, 32 patients (32 knees) died, ten patients (12 knees) were not able to take part in the final clinical and radiological assessment due to physical and mental conditions, but via telephone interview it was confirmed that none of these ten patients (12 knees) had a revision of the knee arthroplasty. One patient (two knees) was lost to follow-up.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 344 - 350
1 Mar 2017
Metcalfe AJ Clark DA Kemp MA Eldridge JD

Aims

The Bereiter trochleoplasty has been used in our unit for 12 years to manage recurrent patellar instability in patients with severe trochlea dysplasia. The aim of this study was to document the outcome of a large consecutive cohort of patients who have undergone this operation.

Patients and Methods

Between June 2002 and August 2013, 214 consecutive trochleoplasties were carried out in 185 patients. There were 133 women and 52 men with a mean age of 21.3 years (14 to 38). All patients were offered yearly clinical and radiological follow-up. They completed the following patient reported outcome scores (PROMs): International Knee Documentation Committee subjective scale, the Kujala score, the Western Ontario and McMaster Universities Arthritis Index score and the short-form (SF)-12.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 329 - 336
1 Mar 2015
Tigchelaar S van Essen P Bénard M Koëter S Wymenga A

An increased tibial tubercle–trochlear groove (TT-TG) distance is related to patellar maltracking and instability. Tibial tubercle transfer is a common treatment option for these patients with good short-term results, although the results can deteriorate over time owing to the progression of osteoarthritis. We present a ten-year follow-up study of a self-centring tibial tubercle osteotomy in 60 knees, 30 with maltracking and 30 with patellar instability. Inclusion criteria were a TT-TG ≥ 15 mm and symptoms for > one year. One patient (one knee) was lost to follow-up and one required total knee arthroplasty because of progressive osteoarthritis. Further patellar dislocations occurred in three knees, all in the instability group, one of which required further surgery. The mean visual analogue scores for pain, and Lysholm and Kujala scores improved significantly and were maintained at the final follow-up (repeated measures, p = 0.000, intergroup differences p = 0.449). Signs of maltracking were found in only a minority of patients, with no difference between groups (p > 0.05). An increase in patellofemoral osteoarthritis was seen in 16 knees (31%) with a maximum of grade 2 on the Kellgren–Lawrence scale. The mean increase in grades was 0.31 (0 to 2) and 0.41 (0 to 2) in the maltracking and instability groups respectively (p = 0.2285)

This self-centring tibial tubercle osteotomy provides good results at ten years’ follow-up without inducing progressive osteoarthritis.

Cite this article: Bone Joint J 2015;97-B:329–36.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 159 - 170
1 Feb 2017
Clark D Metcalfe A Wogan C Mandalia V Eldridge J

Patellar instability most frequently presents during adolescence. Congenital and infantile dislocation of the patella is a distinct entity from adolescent instability and measurable abnormalities may be present at birth. In the normal patellofemoral joint an increase in quadriceps angle and patellar height are matched by an increase in trochlear depth as the joint matures. Adolescent instability may herald a lifelong condition leading to chronic disability and arthritis.

Restoring normal anatomy by trochleoplasty, tibial tubercle transfer or medial patellofemoral ligament (MPFL) reconstruction in the young adult prevents further instability. Although these techniques are proven in the young adult, they may cause growth arrest and deformity where the physis is open. A vigorous non-operative strategy may permit delay of surgery until growth is complete. Where non-operative treatment has failed a modified MPFL reconstruction may be performed to maintain stability until physeal closure permits anatomical reconstruction. If significant growth remains an extraosseous reconstruction of the MPFL may impart the lowest risk to the physis. If minor growth remains image intensifier guided placement of femoral intraosseous fixation may impart a small, but acceptable, risk to the physis.

This paper presents and discusses the literature relating to adolescent instability and provides a framework for management of these patients.

Cite this article: Bone Joint J 2017;99-B:159–70.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 84 - 86
1 Nov 2014
Russell RD Huo MH Jones RE

Patellofemoral complications are common after total knee replacement (TKR). Leaving the patellar unsurfaced after TKR may lead to complications such as anterior knee pain, and re-operation to surface it. Complications after patellar resurfacing include patellar fracture, aseptic loosening, patellar instability, polyethylene wear, patellar clunk and osteonecrosis. Historically, patellar complications account for one of the larger proportions of causes of failure in TKR, however, with contemporary implant designs, complication rates have decreased. Most remaining failures relate to patellofemoral tracking. Understanding the causes of patellofemoral maltracking is essential to prevent these complications as well as manage them when they occur.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):84–6.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 894 - 903
1 Jul 2017
Bonnin MP Saffarini M Nover L van der Maas J Haeberle C Hannink G Victor J

Aims

The morphometry of the distal femur was largely studied to improve bone-implant fit in total knee arthroplasty (TKA), but little is known about the asymmetry of the posterior condyles. This study aimed to investigate the dimensions of the posterior condyles and the influence of externally rotating the femoral component on potential prosthetic overhang or under-coverage.

Patients and Methods

We analysed the shape of 110 arthritic knees at the time of primary TKA using pre-operative CT scans. The height and width of each condyle were measured at the posterior femoral cut in neutral position, and in 3º and 5º of external rotation, using both central and medial referencing systems. We compared the morphological characteristics with those of 14 TKA models.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 60 - 64
1 Jan 2017
Lange J Haas SB

Valgus knee deformity can present a number of unique surgical challenges for the total knee arthroplasty (TKA) surgeon. Understanding the typical patterns of bone and soft-tissue pathology in the valgus arthritic knee is critical for appropriate surgical planning. This review aims to provide the knee arthroplasty surgeon with an understanding of surgical management strategies for the treatment of valgus knee arthritis.

Lateral femoral and tibial deficiencies, contracted lateral soft tissues, attenuated medial soft tissues, and multiplanar deformities may all be present in the valgus arthritic knee. A number of classifications have been reported in order to guide surgical management, and a variety of surgical strategies have been described with satisfactory clinical results. Depending on the severity of the deformity, a variety of TKA implant designs may be appropriate for use.

Regardless of an operating surgeon’s preferred surgical strategy, adherence to a step-wise approach to deformity correction is advised.

Cite this article: Bone Joint J 2017;99-B(1 Supple A):60–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 56 - 61
1 Jan 2012
Kawahara S Matsuda S Fukagawa S Mitsuyasu H Nakahara H Higaki H Shimoto T Iwamoto Y

In posterior stabilised total knee replacement (TKR) a larger femoral component is sometimes selected to manage the increased flexion gap caused by resection of the posterior cruciate ligament. However, concerns remain regarding the adverse effect of the increased anteroposterior dimensions of the femoral component on the patellofemoral (PF) joint. Meanwhile, the gender-specific femoral component has a narrower and thinner anterior flange and is expected to reduce the PF contact force. PF contact forces were measured at 90°, 120°, 130° and 140° of flexion using the NexGen Legacy Posterior Stabilized (LPS)-Flex Fixed Bearing Knee system using Standard, Upsized and Gender femoral components during TKR. Increasing the size of the femoral component significantly increased mean PF forces at 120°, 130° and 140° of flexion (p = 0.005, p < 0.001 and p < 0.001, respectively). No difference was found in contact force between the Gender and the Standard components. Among the patients who had overhang of the Standard component, mean contact forces with the Gender component were slightly lower than those of the Standard component, but no statistical difference was found at 90°, 120°, 130° or 140° of flexion (p = 0.689, 0.615, 0.253 and 0.248, respectively).

Upsized femoral components would increase PF forces in deep knee flexion. Gender-specific implants would not reduce PF forces.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 124 - 128
1 Nov 2013
Hofmann AA Shaeffer JF McCandless JB Magee TH

Isolated patellofemoral arthritis is a common condition and there are varying opinions on the most effective treatments. Non-operative and operative treatments have failed to demonstrate effective long-term treatment for those in an advanced stage of the condition. Newer designs and increased technology in patellofemoral replacement (PFR) have produced more consistent outcomes. This has led to a renewed enthusiasm for this procedure. Newer PFR prostheses have addressed the patellar maltracking issues plaguing some of the older designs. Short-term results with contemporary prostheses and new technology are described here.

Cite this article: Bone Joint J 2013;95-B, Supple A:124–8.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 478 - 485
1 Apr 2013
Naveed MA Ackroyd CE Porteous AJ

We present the ten- to 15-year follow-up of 31 patients (34 knees), who underwent an Elmslie-Trillat tibial tubercle osteotomy for chronic, severe patellar instability, unresponsive to non-operative treatment. The mean age of the patients at the time of surgery was 31 years (18 to 46) and they were reviewed post-operatively, at four years (2 to 8) and then at 12 years (10 to 15). All patients had pre-operative knee radiographs and Cox and Insall knee scores. Superolateral portal arthroscopy was performed per-operatively to document chondral damage and after the osteotomy to assess the stability of the patellofemoral joint. A total of 28 knees (82%) had a varying degree of damage to the articular surface. At final follow-up 25 patients (28 knees) were available for review and underwent clinical examination, radiographs of the knee, and Cox and Insall scoring. Six patients who had no arthroscopic chondral abnormality showed no or only early signs of osteoarthritis on final radiographs; while 12 patients with lower grade chondral damage (grade 1 to 2) showed early to moderate signs of osteoarthritis and six out of ten knees with higher grade chondral damage (grade 3 to 4) showed marked evidence of osteoarthritis; four of these had undergone a knee replacement. In the 22 patients (24 knees) with complete follow-up, 19 knees (79.2%) were reported to have a good or excellent outcome at four years, while 15 knees (62.5%) were reported to have the same at long-term follow-up. The functional and radiological results show that the extent of pre-operatively sustained chondral damage is directly related to the subsequent development of patellofemoral osteoarthritis.

Cite this article: Bone Joint J 2013;95-B:478–85.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 3 - 10
1 Oct 2016
Hamilton TW Pandit HG Lombardi AV Adams JB Oosthuizen CR Clavé A Dodd CAF Berend KR Murray DW

Aims

An evidence-based radiographic Decision Aid for meniscal-bearing unicompartmental knee arthroplasty (UKA) has been developed and this study investigates its performance at an independent centre.

Patients and Methods

Pre-operative radiographs, including stress views, from a consecutive cohort of 550 knees undergoing arthroplasty (UKA or total knee arthroplasty; TKA) by a single-surgeon were assessed. Suitability for UKA was determined using the Decision Aid, with the assessor blinded to treatment received, and compared with actual treatment received, which was determined by an experienced UKA surgeon based on history, examination, radiographic assessment including stress radiographs, and intra-operative assessment in line with the recommended indications as described in the literature.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 737 - 742
1 May 2010
Verlinden C Uvin P Labey L Luyckx JP Bellemans J Vandenneucker H

Malrotation of the femoral component is a cause of patellofemoral maltracking after total knee arthroplasty. Its precise effect on the patellofemoral mechanics has not been well quantified. We have developed an in vitro method to measure the influence of patellar maltracking on contact. Maltracking was induced by progressively rotating the femoral component either internally or externally. The contact mechanics were analysed using Tekscan. The results showed that excessive malrotation of the femoral component, both internally and externally, had a significant influence on the mechanics of contact. The contact area decreased with progressive maltracking, with a concomitant increase in contact pressure. The amount of contact area that carries more than the yield stress of ultra-high molecular weight polyethylene significantly increases with progressive maltracking. It is likely that the elevated pressures noted in malrotation could cause accelerated and excessive wear of the patellar button.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 436 - 444
1 Apr 2013
Scott CEH Nutton RW Biant LC

The lateral compartment is predominantly affected in approximately 10% of patients with osteoarthritis of the knee. The anatomy, kinematics and loading during movement differ considerably between medial and lateral compartments of the knee. This in the main explains the relative protection of the lateral compartment compared with the medial compartment in the development of osteoarthritis. The aetiology of lateral compartment osteoarthritis can be idiopathic, usually affecting the femur, or secondary to trauma commonly affecting the tibia. Surgical management of lateral compartment osteoarthritis can include osteotomy, unicompartmental knee replacement and total knee replacement. This review discusses the biomechanics, pathogenesis and development of lateral compartment osteoarthritis and its management.

Cite this article: Bone Joint J 2013;95-B:436–44.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 723 - 729
1 Jun 2016
Jones MH Williams AM

Osteochondritis Dissecans (OCD) is a condition for which the aetiology remains unknown. It affects subchondral bone and secondarily its overlying cartilage and is mostly found in the knee. It can occur in adults, but is generally identified when growth remains, when it is referred to as juvenile OCD. As the condition progresses, the affected subchondral bone separates from adjacent healthy bone, and can lead to demarcation and separation of its associated articular cartilage. Any symptoms which arise relate to the stage of the disease. Early disease without separation of the lesion results in pain. Separation of the lesion leads to mechanical symptoms and swelling and, in advanced cases, the formation of loose bodies.

Early identification of OCD is essential as untreated OCD can lead to the premature degeneration of the joint, whereas appropriate treatment can halt the disease process and lead to healing. Establishing the stability of the lesion is a key part of providing the correct treatment. Stable lesions, particularly in juvenile patients, have greater propensity to heal with non-surgical treatment, whereas unstable or displaced lesions usually require surgical management.

This article discusses the aetiology, clinical presentation and prognosis of OCD in the knee. It presents an algorithm for treatment, which aims to promote healing of native hyaline cartilage and to ensure joint congruity.

Take home message: Although there is no clear consensus as to the best treatment of OCD, every attempt should be made to retain the osteochondral fragment when possible as, with a careful surgical technique, there is potential for healing even in chronic lesions

Cite this article: Bone Joint J 2016;98-B:723–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 1 - 6
1 Jan 2010
Clifton R Ng CY Nutton RW

We have reviewed the literature to establish the role of lateral retinacular release in the management of disorders of the extensor apparatus of the knee. The scientific evidence for intervention is explored and reports on outcome are discussed.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 622 - 627
1 May 2016
Donaldson JR Tudor F Gollish J

Aims

The aim of this study was to examine the results of revision total knee arthroplasty (TKA) undertaken for stiffness in the absence of sepsis or loosening.

Patients and Methods

We present the results of revision surgery for stiff TKA in 48 cases (35 (72.9%) women and 13 (27.1%) men). The mean age at revision surgery was 65.5 years (42 to 83). All surgeries were performed by a single surgeon. Stiffness was defined as an arc of flexion of < 70° or a flexion contracture of > 15°. The changes in the range of movement (ROM) and the Western Ontario and McMasters Osteoarthritis index scores (WOMAC) were recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 141 - 146
1 Nov 2012
Minas T

Hyaline articular cartilage has been known to be a troublesome tissue to repair once damaged. Since the introduction of autologous chondrocyte implantation (ACI) in 1994, a renewed interest in the field of cartilage repair with new repair techniques and the hope for products that are regenerative have blossomed. This article reviews the basic science structure and function of articular cartilage, and techniques that are presently available to effect repair and their expected outcomes.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 54 - 58
1 Jan 2014
Vijayan S Bentley G Rahman J Briggs TWR Skinner JA Carrington RWJ

The management of failed autologous chondrocyte implantation (ACI) and matrix-assisted autologous chondrocyte implantation (MACI) for the treatment of symptomatic osteochondral defects in the knee represents a major challenge. Patients are young, active and usually unsuitable for prosthetic replacement. This study reports the results in patients who underwent revision cartilage transplantation of their original ACI/MACI graft for clinical or graft-related failure. We assessed 22 patients (12 men and 10 women) with a mean age of 37.4 years (18 to 48) at a mean of 5.4 years (1.3 to 10.9). The mean period between primary and revision grafting was 46.1 months (7 to 89). The mean defect size was 446.6 mm2 (150 to 875) and they were located on 11 medial and two lateral femoral condyles, eight patellae and one trochlea.

The mean modified Cincinnati knee score improved from 40.5 (16 to 77) pre-operatively to 64.9 (8 to 94) at their most recent review (p < 0.001). The visual analogue pain score improved from 6.1 (3 to 9) to 4.7 (0 to 10) (p = 0.042). A total of 14 patients (63%) reported an ‘excellent’ (n = 6) or ‘good’ (n = 8) clinical outcome, 5 ‘fair’ and one ‘poor’ outcome. Two patients underwent patellofemoral joint replacement. This study demonstrates that revision cartilage transplantation after primary ACI and MACI can yield acceptable functional results and continue to preserve the joint.

Cite this article: Bone Joint J 2014;96-B:54–8.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 3 - 8
1 Oct 2015
Murray DW Liddle AD Dodd CAF Pandit H

There is a large amount of evidence available about the relative merits of unicompartmental and total knee arthroplasty (UKA and TKA). Based on the same evidence, different people draw different conclusions and as a result, there is great variability in the usage of UKA.

The revision rate of UKA is much higher than TKA and so some surgeons conclude that UKA should not be performed. Other surgeons believe that the main reason for the high revision rate is that UKA is easy to revise and, therefore, the threshold for revision is low. They also believe that UKA has many advantages over TKA such as a faster recovery, lower morbidity and mortality and better function. They therefore conclude that UKA should be undertaken whenever appropriate.

The solution to this argument is to minimise the revision rate of UKA, thereby addressing the main disadvantage of UKA. The evidence suggests that this will be achieved if surgeons use UKA for at least 20% of their knee arthroplasties and use implants that are appropriate for these broad indications.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):3–8.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1064 - 1068
1 Aug 2013
Cavaignac E Lafontan V Reina N Pailhé R Warmy M Laffosse JM Chiron P

The significance of weight in the indications for unicompartmental knee replacement (UKR) is unclear. Our hypothesis was that weight does not affect the long-term rate of survival of UKRs.

We undertook a retrospective study of 212 UKRs at a mean follow-up of 12 years (7 to 22). The patients were distributed according to body mass index (BMI; < vs ≥ 30 kg/m2) and weight (< vs ≥ 82 kg). Kaplan-Meier survivorship analysis was performed and ten-year survival rates were compared between the sub-groups. Multimodal regression analysis determined the impact of the various theoretical contraindications on the long-term rate of survival of UKR.

The ten-year rates of survival were similar in the two weight subgroups (≥ 82 kg: 93.5% (95% confidence interval (CI) 66.5 to 96.3); < 82 kg: 92.5% (95% CI 82.5 to 94.1)) and also in the two BMI subgroups (≥ 30 kg/m2: 92% (95% CI 82.5 to 95.3); < 30 kg/m2: 94% (95% CI 78.4 to 95.9)). Multimodal regression analysis revealed that weight plays a part in reducing the risk of revision with a relative risk of 0.387, although this did not reach statistical significance (p = 0.662). The results relating weight and BMI to the clinical outcome were not statistically significant. Thus, this study confirms that weight does not influence the long-term rate of survival of UKR.

Cite this article: Bone Joint J 2013;95-B:1064–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 54 - 60
1 Jan 2006
Pandit H Jenkins C Barker K Dodd CAF Murray DW

This prospective study describes the complications and survival of the first 688 Phase 3 Oxford medial unicompartmental knee replacements implanted using a minimally-invasive technique by two surgeons and followed up independently. None was lost to follow-up. We had carried out 132 of the procedures more than five years ago. The clinical assessment of 101 of these which were available for review at five years is also presented.

Nine of the 688 knees were revised: four for infection, three for dislocation of the bearing and two for unexplained pain. A further seven knees (1%) required other procedures: four had a manipulation under anaesthesia, two an arthroscopy and one a debridement for superficial infection. The survival rate at seven years was 97.3% (95% confidence interval 5.3). At five years, 96% of the patients had a good or excellent American Knee Society score, the mean Oxford knee score was 39 and the mean flexion was 133°. This study demonstrates that the minimally-invasive Oxford unicompartmental knee replacement is a reliable and effective procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 180 - 185
1 Feb 2008
Utting MR Mulford JS Eldridge JDJ

Trochlear dysplasia is a developmental condition characterised by an abnormally flat or dome-shaped trochlea and is an important contributory factor to patellofemoral instability and recurrent dislocation. We studied prospectively a series of 54 consecutive patients (59 knees) with patellofemoral instability secondary to trochlear dysplasia, who were treated by a trochleoplasty by a single surgeon between June 2002 and June 2007.

Pre- and post-operative scores were assessed by the patients and a satisfaction questionnaire was completed.

Of the 54 patients (59 knees) in the series, 39 (44 knees) were female and 15 (15 knees) were male. Their mean age at surgery was 21 years and 6 months (14 years 4 months to 33 years 11 months). In 40 patients (42 knees) the mean follow-up was for 24 months (12 to 58). One patient was unable to attend for follow-up. An analysis of the results of those patients followed up for at least 12 months showed a statistically significant improvement in outcome (p < 0.001 for all scores). Overall, 50 patients (92.6%) were satisfied with the outcome of their procedure.

The early results of trochleoplasty are encouraging in this challenging group of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 527 - 534
1 Apr 2008
Merican AM Amis AA

Anatomical descriptions of the lateral retinaculum have been published, but the attachments, name or even existence of its tissue bands and layers are ill-defined. We have examined 35 specimens of the knee. The deep fascia is the most superficial layer and the joint capsule is the deepest. The intermediate layer is the most substantial and consists of derivatives of the iliotibial band and the quadriceps aponeurosis. The longitudinal fibres of the iliotibial band merge with those of the quadriceps aponeurosis adjacent to the patella. These longitudinal fibres are reinforced by superficial arciform fibres and on the deep aspect by transverse fibres of the iliotibial band. The latter are dense and provide attachment of the iliotibial band to the patella and the tendon of vastus lateralis obliquus.

Our study identifies two important new findings which are a constant connection of the deep fascia to the quadriceps tendon superior and lateral to the patella, and, a connection of the deeper transverse fibres to the tendon of vastus lateralis obliquus.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1228 - 1233
1 Sep 2012
Baliga S McNair CJ Barnett KJ MacLeod J Humphry RW Finlayson D

The incidence of anterior knee pain following total knee replacement (TKR) is reported to be as high as 49%. The source of the pain is poorly understood but the soft tissues around the patella have been implicated.

In theory circumferential electrocautery denervates the patella thereby reducing efferent pain signals. However, there is mixed evidence that this practice translates into improved outcomes.

We aimed to investigate the clinical effect of intra-operative circumpatellar electrocautery in patients undergoing TKR using the LCS mobile bearing or Kinemax fixed bearing TKR. A total of 200 patients were randomised to receive either circumpatellar electrocautery (diathermy) or not (control). Patients were assessed by visual analogue scale (VAS) for anterior knee pain and Oxford knee score (OKS) pre-operatively and three months, six months and one year post-operatively. Patients and assessors were blinded.

There were 91 patients in the diathermy group and 94 in the control. The mean VAS improvement at one year was 3.9 in both groups (control; -10 to 6, diathermy; -9 to 8, p < 0.001 in both cases, paired, two-tailed t-test). There was no significant difference in VAS between the groups at any other time. The mean OKS improvement was 17.7 points (0 to 34) in the intervention group and 16.6 (0 to 42) points in the control (p = 0.36). There was no significant difference between the two groups in OKS at any other time.

We found no relevant effect of patellar electrocautery on either VAS anterior knee pain or OKS for patients undergoing LCS and Kinemax TKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 198 - 204
1 Feb 2011
Pandit H Jenkins C Gill HS Barker K Dodd CAF Murray DW

This prospective study describes the outcome of the first 1000 phase 3 Oxford medial unicompartmental knee replacements (UKRs) implanted using a minimally invasive surgical approach for the recommended indications by two surgeons and followed up independently. The mean follow-up was 5.6 years (1 to 11) with 547 knees having a minimum follow-up of five years. At five years their mean Oxford knee score was 41.3 (sd 7.2), the mean American Knee Society Objective Score 86.4 (sd 13.4), mean American Knee Society Functional Score 86.1 (sd 16.6), mean Tegner activity score 2.8 (sd 1.1). For the entire cohort, the mean maximum flexion was 130° at the time of final review.

The incidence of implant-related re-operations was 2.9%; of these 29 re-operations two were revisions requiring revision knee replacement components with stems and wedges, 17 were conversions to a primary total knee replacement, six were open reductions for dislocation of the bearing, three were secondary lateral UKRs and one was revision of a tibial component. The most common reason for further surgical intervention was progression of arthritis in the lateral compartment (0.9%), followed by dislocation of the bearing (0.6%) and revision for unexplained pain (0.6%). If all implant-related re-operations are considered failures, the ten-year survival rate was 96% (95% confidence interval, 92.5 to 99.5). If only revisions requiring revision components are considered failures the ten-year survival rate is 99.8% (confidence interval 99 to 100).

This is the largest published series of UKRs implanted through a minimally invasive surgical approach and with ten-year survival data. The survival rates are similar to those obtained with a standard open approach whereas the function is better. This demonstrates the effectiveness and safety of a minimally invasive surgical approach for implanting the Oxford UKR.