Advertisement for orthosearch.org.uk
Results 1 - 93 of 93
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 559 - 566
1 May 2022
Burden EG Batten T Smith C Evans JP

Aims. Arthroplasty is being increasingly used for the management of distal humeral fractures (DHFs) in elderly patients. Arthroplasty options include total elbow arthroplasty (TEA) and hemiarthroplasty (HA); both have unique complications and there is not yet a consensus on which implant is superior. This systematic review asked: in patients aged over 65 years with unreconstructable DHFs, what differences are there in outcomes, as measured by patient-reported outcome measures (PROMs), range of motion (ROM), and complications, between distal humeral HA and TEA?. Methods. A systematic review of the literature was performed via a search of MEDLINE and Embase. Two reviewers extracted data on PROMs, ROM, and complications. PROMs and ROM results were reported descriptively and a meta-analysis of complications was conducted. Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROSPERO (CRD42021228329). Results. A total of 29 studies met the inclusion and exclusion criteria. The mean Disabilities of the Arm, Shoulder and Hand questionnaire (DASH) score was 19.6 (SD 7.5) for HA and 38 (SD 11.9) for TEA and the mean abbreviated version of DASH was 17.2 (SD 13.2) for HA and 24.9 (SD 4.8) for TEA. The Mayo Elbow Performance Score was the most commonly reported PROM across included studies, with a mean of 87 (SD 5.3) in HA and 88.3 (SD 5) in TEA. High complication rates were seen in both HA (22% (95% confidence interval (CI) 5 to 44)) and TEA (21% (95% CI 13 to 30), but no statistically significant difference identified. Conclusion. This systematic review has indicated PROMs and ROM mostly favouring HA, but with a similarly high complication rate in the two procedures. However, due to the small sample size and heterogeneity between studies, strength of evidence for these findings is low. We propose further research in the form of a national randomized controlled trial. Cite this article: Bone Joint J 2022;104-B(5):559–566


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims. The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome. Methods. We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome. Results. A total of 38 studies including 2,118 TEAs were included in the study. The mean follow-up was 80.9 months (8.2 to 156). The implant failure and complication rates were 16.1% (95% confidence interval (CI) 0.128 to 0.200) and 24.5% (95% CI 0.203 to 0.293), respectively. Aseptic loosening was the most common mode of failure (9.5%; 95% CI 0.071 to 0.124). The mean postoperative ranges of motion (ROMs) were: flexion 131.5° (124.2° to 138.8°), extension 29.3° (26.8° to 31.9°), pronation 74.0° (67.8° to 80.2°), and supination 72.5° (69.5° to 75.5°), and the mean postoperative Mayo Elbow Performance Score (MEPS) was 89.3 (95% CI 86.9 to 91.6). The meta-regression analysis identified that younger patients and implants with an unlinked design correlated with higher failure rates. Younger patients were associated with increased complications, while female patients and an unlinked prosthesis were associated with aseptic loosening. Conclusion. TEA continues to provide satisfactory results for patients with RA. However, it is associated with a substantially higher implant failure and complication rates compared with hip and knee arthroplasties. The patient’s age, sex, and whether cemented fixation and unlinked prosthesis were used can influence the outcome. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Joint J 2020;102-B(8):967–980


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1489 - 1497
1 Dec 2019
Wang J Ma H Chou TA Tsai S Chen C Wu P Chen W

Aims. The aim of this meta-analysis was to compare the outcome of total elbow arthroplasty (TEA) undertaken for rheumatoid arthritis (RA) with TEA performed for post-traumatic conditions with regard to implant failure, functional outcome, and perioperative complications. Materials and Methods. We completed a comprehensive literature search on PubMed, Web of Science, Embase, and the Cochrane Library and conducted a systematic review and meta-analysis. Nine cohort studies investigated the outcome of TEA between RA and post-traumatic conditions. The preferred reporting items for systematic reviews and meta-analysis (Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)) guidelines and Newcastle-Ottawa scale were applied to assess the quality of the included studies. We assessed three major outcome domains: implant failures (including aseptic loosening, septic loosening, bushing wear, axle failure, component disassembly, or component fracture); functional outcomes (including arc of range of movement, Mayo Elbow Performance Score (MEPS), and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), and perioperative complications (including deep infection, intraoperative fracture, postoperative fracture, and ulnar neuropathy). Results. This study included a total of 679 TEAs for RA (n = 482) or post-traumatic conditions (n = 197). After exclusion, all of the TEAs included in this meta-analysis were cemented with linked components. Our analysis demonstrated that the RA group was associated with a higher risk of septic loosening after TEA (odds ratio (OR) 3.96, 95% confidence interval (CI) 1.11 to 14.12), while there was an increased risk of bushing wear, axle failure, component disassembly, or component fracture in the post-traumatic group (OR 4.72, 95% CI 2.37 to 9.35). A higher MEPS (standardized mean difference 0.634, 95% CI 0.379 to 0.890) was found in the RA group. There were no significant differences in arc of range of movement, DASH questionnaire, and risk of aseptic loosening, deep infection, perioperative fracture, or ulnar neuropathy. Conclusion. The aetiology of TEA surgery appears to have an impact on the outcome in terms of specific modes of implant failures. RA patients might have a better functional outcome after TEA surgery. Cite this article: Bone Joint J 2019;101-B:1489–1497


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1066 - 1073
1 Aug 2018
Nishida K Hashizume K Nasu Y Ozawa M Fujiwara K Inoue H Ozaki T

Aims

The aim of this study was to report the mid-term clinical outcome of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties when used in patients with rheumatoid arthritis (RA).

Patients and Methods

We retrospectively reviewed 87 elbows, in 75 patients with RA, which was replaced using a cemented JACE total elbow arthroplasty (TEA) between August 2003 and December 2012, with a follow-up of 96%. There were 72 women and three men, with a mean age of 62 years (35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition of each elbow before and after surgery was assessed using the Mayo Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening was defined as a progressive radiolucent line of >1 mm that was completely circumferential around the prosthesis.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1096 - 1101
1 Aug 2015
Oizumi N Suenaga N Yoshioka C Yamane S

To prevent insufficiency of the triceps after total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar approach. This study evaluates the clinical results and post-operative alignment of the prosthesis using this approach.

We reviewed 25 elbows in 23 patients. There were five men and 18 women with a mean age of 69 years (54 to 83). There were 18 elbows with rheumatoid arthritis, six with a fracture or pseudoarthrosis and one elbow with osteoarthritis.

Post-operative complications included one intra-operative fracture, one elbow with heterotopic ossification, one transient ulnar nerve palsy, and one elbow with skin necrosis, but no elbow was affected by insufficiency of the triceps.

Patients were followed for a mean of 42 months (24 to 77). The mean post-operative Japanese Orthopaedic Association Elbow Score was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8 (65 to 100). The mean post-operative flexion/extension of the elbow was 135°/-8°. The Manual Muscle Testing score of the triceps was 5 in 23 elbows and 2 in two elbows (one patient). The mean alignment of the implants examined by 3D-CT was 2.8° pronation (standard deviation (sd) 5.5), 0.3° valgus (sd 2.7), and 0.7° extension (sd 3.2) for the humeral component, and 9.3° pronation (sd 9.7), 0.3° valgus (sd 4.0), and 8.6° extension (sd 3.1) for the ulnar component. There was no radiolucent line or loosening of the implants on the final radiographs.

The triceps-sparing ulnar approach allows satisfactory alignment of the implants, is effective in preventing post-operative triceps insufficiency, and gives satisfactory short-term results.

Cite this article: 2015;97-B:1096–1101.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1198 - 1204
1 Sep 2008
Peden JP Morrey BF

This study reports our experience with total elbow replacement for fused elbows. Between 1982 and 2004, 13 patients with spontaneously ankylosed elbows were treated with a linked semi-constrained non-custom total elbow implant. The mean age at operation was 54 years (24 to 80). The stiffness was a result of trauma in ten elbows, juvenile rheumatoid arthritis in one, and rheumatoid arthritis in two. The patients were followed for a mean of 12 years (2 to 26) and were evaluated clinically using the Mayo Elbow Performance Score, as well as radiologically. A mean arc from 37° of extension to 118° of flexion was achieved. Outcomes were good or excellent for seven elbows at final review. Ten patients felt better or much better after total elbow replacement. However, there was a high complication rate and re-operation was required in over half of patients. Two developed peri-operative soft-tissue breakdown requiring debridement. A muscle flap with skin grafting was used for soft-tissue cover in one. Revision was undertaken in one elbow following fracture of the ulnar component. Three patients developed a deep infection. Three elbows were manipulated under anaesthesia for post-operative stiffness. Prophylactic measures for heterotopic ossification were unsuccessful. Total elbow replacement for the ankylosed elbow should be performed with caution. However, the outcome can be reliable in the long term and have a markedly positive impact on patient function and satisfaction. The high potential for complications must be considered. We consider total elbow replacement to be an acceptable procedure in selected patients with reasonable expectations


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 330 - 334
1 Mar 2007
Cesar M Roussanne Y Bonnel F Canovas F

Between 1993 and 2002, 58 GSB III total elbow replacements were implanted in 45 patients with rheumatoid arthritis by the same surgeon. At the most recent follow-up, five patients had died (five elbows) and six (nine elbows) had been lost to follow-up, leaving 44 total elbow replacements in 34 patients available for clinical and radiological review at a mean follow-up of 74 months (25 to 143). There were 26 women and eight men with a mean age at operation of 55.7 years (24 to 77). At the latest follow-up, 31 excellent (70%), six good (14%), three fair (7%) and four poor (9%) results were noted according to the Mayo elbow performance score. Five humeral (11%) and one ulnar (2%) component were loose according to radiological criteria (type III or type IV). Of the 44 prostheses, two (5%) had been revised, one for type-IV humeral loosening after follow-up for ten years and one for fracture of the ulnar component. Seven elbows had post-operative dysfunction of the ulnar nerve, which was transient in five and permanent in two. Despite an increased incidence of loosening with time, the GSB III prosthesis has given favourable mid-term results in patients with rheumatoid arthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1416 - 1421
1 Oct 2010
Qureshi F Draviaraj KP Stanley D

Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1348 - 1351
1 Oct 2008
Rispoli DM Athwal GS Morrey BF

Ulnar neuropathy presents as a complication in 5% to 10% of total elbow replacements, but subsequent ulnar neurolysis is rarely performed. Little information is available on the surgical management of persistent ulnar neuropathy after elbow replacement. We describe our experience with the surgical management of this problem. Of 1607 total elbow replacements performed at our institution between January 1969 and December 2004, eight patients (0.5%) had a further operation for persistent or progressive ulnar neuropathy. At a mean follow-up of 9.2 years (3.1 to 21.7) six were clinically improved and satisfied with their outcome, although, only four had complete recovery. When transposition was performed on a previously untransposed nerve the rate of recovery was 75%, but this was reduced to 25% if the nerve had been transposed at the time of the replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1369 - 1374
1 Oct 2005
Athwal GS Chin PY Adams RA Morrey BF

We reviewed 20 patients who had undergone a Coonrad-Morrey total elbow arthroplasty after resection of a primary or metastatic tumour from the elbow or distal humerus between 1980 and 2002. Eighteen patients underwent reconstruction for palliative treatment with restoration of function after intralesional surgery and two after excision of a primary bone tumour. The mean follow-up was 30 months (1 to 192). Five patients (25%) were alive at the final follow-up; 14 (70%) had died of their disease and one of unrelated causes. Local control was achieved in 15 patients (75%). The mean Mayo Elbow Performance Score improved from 22 (5 to 45) to 75 points (55 to 95). Four reconstructions (20%) failed and required revision. Seven patients (35%) had early complications, the most frequent being nerve injury (25%). There were no infections or wound complications although 18 patients (90%) had radiotherapy, chemotherapy or both. The Coonrad-Morrey total elbow arthroplasty provides good relief from pain and a good functional outcome after resection of tumours of the elbow. The rates of complications involving local recurrence of tumour (25%) and nerve injury (25%) are of concern


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 767 - 771
1 Jun 2018
Robinson PM MacInnes SJ Stanley D Ali AA

Aim. The primary aim of this retrospective study was to identify the incidence of heterotopic ossification (HO) following elective and trauma elbow arthroplasty. The secondary aim was to determine clinical outcomes with respect to the formation of heterotopic ossification. Patients and Methods. A total of 55 total elbow arthroplasties (TEAs) (52 patients) performed between June 2007 and December 2015 were eligible for inclusion in the study (29 TEAs for primary elective arthroplasty and 26 TEAs for trauma). At review, 15 patients (17 total elbow arthroplasties) had died from unrelated causes. There were 14 men and 38 women with a mean age of 70 years (42 to 90). The median clinical follow-up was 3.6 years (1.2 to 6) and the median radiological follow-up was 3.1 years (0.5 to 7.5). Results. The overall incidence of HO was 84% (46/55). This was higher in the trauma group (96%, 25/26) compared with the elective arthroplasty group (72%, 21/29) (p = 0.027, Fisher’s exact test). Patients in the trauma group had HO of higher Brooker class. The presence of HO did not significantly affect elbow range of movement within the trauma or elective groups (elective arthroplasty, Mann–Whitney U test, p = 0.070; trauma arthroplasty, p = 0.370, Mann–Whitney U test). Conclusion. HO after total elbow arthroplasty is seen more commonly than previously reported. We have reported a significantly higher rate of HO in TEAs performed for trauma than those performed electively. Cite this article: Bone Joint J 2018;100-B:767–71


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 341 - 344
1 Mar 2006
Tanaka N Sakahashi H Ishii S Kudo H

The purpose of this study was to assess the long-term results (more than ten years) of two types of cemented ulnar component with type-5 Kudo total elbow arthroplasty in a consecutive series of 56 patients (60 elbows) with rheumatoid arthritis, and to compare the results in elbows above and below a Larsen grade IV. There was no radiolucency around the humeral component. Patients in whom a metal-backed ulnar component and a porous-coated stem were used had better clinical results and significantly less progression of radiolucent line formation around the ulnar component. They also had a significantly better long-term survival than patients with an all-polyethylene ulnar component. The clinical results of arthroplasty using all-polyethylene ulnar components were inferior, regardless of the degree of joint destruction. We conclude that the type-5 Kudo total elbow arthroplasty with cementless fixation of the porous-coated humeral component and cemented fixation of a metal-backed ulnar component is acceptable and well-tolerated by rheumatoid patients


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 950 - 954
1 Jul 2005
Khatri M Stirrat AN

We present the outcome of 47 Souter-Strathclyde replacements of the elbow with a mean follow-up of 82 months (12 to 129). The clinical results were assessed using a condition-specific outcome measure. The mean total score (maximum 100) before the operation was 47.21 and improved to 79.92 (p < 0.001). The mean pain score (maximum 50) improved from 21.41 to 46.70 (p < 0.001) and the mean functional component of the score (maximum 30) from 11.19 to 18.65 (p < 0.001). There was negligible change in the score for the range of movement although a significant improvement in mean flexion from 124° to 136° was noted (p < 0.001). Revision surgery was required in four patients, for dislocation, wound dehiscence and early infection in one, late infection in two and aseptic loosening in one. The cumulative survival was 75% at nine years for all causes of failure and 97% at ten years for aseptic loosening alone. Our study demonstrates the value of the Souter-Strathclyde total elbow arthroplasty in providing relief from pain and functional improvement in rheumatoid patients


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 509 - 514
1 Apr 2006
Aldridge JM Lightdale NR Mallon WJ Coonrad RW

There have been few reports in the literature of total elbow arthroplasty extending beyond 10 to 15 years. We reviewed 40 patients (41 elbows) with a mean age of 56 years (19 to 83) who had undergone a Coonrad/Coonrad-Morrey elbow arthroplasty by one surgeon for various diagnoses between 1974 and 1994. Surgical selection excluded patients with previous elbow infection or who refused to accept a sedentary level of elbow activity postoperatively. Objective data were collected from charts, radiographs, clinical photographs and supplemented by the referring orthopaedic surgeons’ records and radiographs if health or distance prevented a patient from returning for final review. Subjective outcome was defined by patient satisfaction. Of the 41 elbows, 21 were functional between 10 and 14 years after operation, ten between 15 and 19 years and ten between 20 and 31 years. There were 14 complications and 13 revisions, but no cases of acute infection, or permanent removal of any implant


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1460 - 1463
1 Nov 2006
Landor I Vavrik P Jahoda D Guttler K Sosna A

We assessed the long-term results of 58 Souter-Strathclyde total elbow replacements in 49 patients with rheumatoid arthritis. The mean length of follow-up was 9.5 years (0.7 to 16.7). The mean pre-operative Mayo Elbow Performance Score was 30 (15 to 80) and at final follow-up was 82 (60 to 95). A total of 13 elbows (22.4%) were revised, ten (17.2%) for aseptic loosening, one (1.7%) for instability, one (1.7%) for secondary loosening after fracture, and one elbow (1.7%) was removed because of deep infection. The Kaplan-Meier survival rate was 70% and 53% at ten and 16 years, respectively. Failure of the ulnar component was found to be the main problem in relation to the loosening. Anterior transposition of the ulnar nerve had no influence on ulnar nerve paresthaesiae in these patients


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 691 - 695
1 Sep 1995
Dent C Hoy G Stanley J

We reviewed 25 patients with rheumatoid arthritis who had failure of 26 primary total elbow arthroplasties causing pain and loss of function. Most revision cases required special custom implants to treat varying bone loss and soft-tissue disruption. Assessment showed satisfactory functional results in the patients treated by revision at a mean follow-up period of 35 months. Our review suggests that revision surgery produces short- to medium-term painfree function, and is the treatment of choice for a failed total elbow arthroplasty in the absence of infection


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 656 - 660
1 May 2010
Ikävalko M Tiihonen R Skyttä ET Belt EA

Between 1982 and 1997, 403 consecutive patients (522 elbows) with rheumatoid arthritis underwent Souter-Strathclyde total elbow replacement. By the end of 2007, there had been 66 revisions for aseptic loosening in 60 patients. The mean time of follow-up was 10.6 years (0 to 25) The survival rates at five-, ten, 15 and 19 years were 96% (95%, confidence interval (CI) 95 to 98), 89% (95% CI 86 to 92), 83% (95% CI 78 to 87), and 77% (95% CI 69 to 85), respectively. The small and medium-sized short-stemmed primary humeral components had a 5.6-fold and 3.6-fold risk of revision for aseptic loosening respectively, compared to the medium-sized long-stemmed component. The small and medium-sized all-polyethylene ulnar components had respectively a 28.2-fold and 8.4-fold risk of revision for aseptic loosening, compared to the metal-backed ulnar components. The use of retentive ulnar components was not associated with an increased risk of aseptic loosening compared to non-retentive implants


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1341 - 1346
1 Oct 2006
Gille J Ince A González O Katzer A Loehr JF

This study reviews the predisposing features, the clinical, and laboratory findings at the time of diagnosis and the results of single-stage revision of prosthetic replacement of the elbow for infection. Deep infection occurred in six of 305 (1.9%) primary total elbow replacements. The mean follow-up after revision was 6.8 years (6 months to 16 years) and the mean age at the time of revision was 62.7 years (56 to 74). All six cases with infection had rheumatoid arthritis and had received steroid therapy. The infective organism was Staphylococcus aureus. Four of the six elbows had a developed radiolucency around one component or the other. Successful single-stage exchange arthroplasty was carried out with antibiotic-loaded cement in five of the six cases. In one, the revision prosthesis had to be removed following recurrence of the infection. The functional result was good in three elbows, fair in one, poor in one and fair in the resection arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 343 - 348
1 Mar 2008
Prasad N Dent C

We analysed the outcome of the Coonrad-Morrey total elbow replacement used for fracture of the distal humerus in elderly patients with no evidence of inflammatory arthritis and compared the results for early versus delayed treatment. We studied a total of 32 patients with 15 in the early treatment group and 17 in the delayed treatment group. The mean follow-up was 56.1 months (18 to 88). The percentage of excellent to good results based on the Mayo elbow performance score was not significantly different, 84% in the early group and 79% in the delayed group. Subjective satisfaction was 92% in both the groups. One patient in the early group developed chronic regional pain syndrome and another type 4 aseptic loosening. Two elbows in the early group also showed type 1 radiological loosening. Two patients in the delayed group had an infection, two an ulnar nerve palsy, one developed heterotopic ossification and one type 4 aseptic loosening. Two elbows in this group also showed type 1 radiological loosening. The Kaplan-Meier survivorship analysis for the early and delayed treatment groups was 93% at 88 months and 76% at 84 months, respectively. No significant difference was found between the two groups


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 47 - 53
1 Jan 2005
Whaley A Morrey BF Adams R

We examined the effects of previous resection of the radial head and synovectomy on the outcome of subsequent total elbow arthroplasty in patients with rheumatoid arthritis. Fifteen elbows with a history of resection and synovectomy were compared with a control group of patients who had elbow arthroplasty with an implant of the same design. The mean age in both groups was 63 years. In the study group, resection of the radial head and synovectomy had been undertaken at a mean of 8.9 years before arthroplasty. The mean radiological follow-up for the 13 available patients in the study group was 5.89 years (0.3 to 11.0) and in the control group was 6.6 years (2.2 to 12.6). There were no revisions in either group. The mean Mayo elbow performance score improved from 29 to 96 in the study group, with similar improvement in the control group (28 to 87). The study group had excellent results in 13 elbows and good results in two. The control group had excellent results in seven and good results in six. Our experience indicates that previous resection of the radial head and synovectomy are not associated with an increased rate of revision following subsequent arthroplasty of the elbow. However, there was a higher rate of complication in the study group compared with the control group


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims. Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA. Patients and Methods. Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three. Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89). Results. The ROM of the elbow did not improve significantly. The mean EFAS and MAESS scores improved significantly six months post-operatively (18.6 points, standard deviation (. sd. ) 7.7; p = 0.03 and 28.8 points, . sd . 8.6; p = 0.006, respectively) and continued to improve slightly or reached a plateau. The mean pain scores at rest (Z = -3.2, p = 0.001) and during activity (Z = -3.2, p = 0.001), and stability (Z = -3.0, p = 0.003) improved significantly six months post-operatively. Thereafter scores continued to improve slightly or a plateau was reached. There were no signs of loosening. Conclusion. Revision surgery using the Latitude TEA results in improvement of functionality, reduced pain and better stability of the elbow. Improvement of ROM of the elbow should not be expected. Cite this article: Bone Joint J 2016;98-B:1086–92


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1681 - 1686
1 Dec 2013
Peach CA Nicoletti S Lawrence TM Stanley D

We report our experience of staged revision surgery for the treatment of infected total elbow arthroplasty (TEA). Between 1998 and 2010 a consecutive series of 33 patients (34 TEAs) underwent a first-stage procedure with the intention to proceed to second-stage procedure when the infection had been controlled. A single first-stage procedure with removal of the components and cement was undertaken for 29 TEAs (85%), followed by the insertion of antibiotic-impregnated cement beads, and five (15%) required two or more first-stage procedures. The most common organism isolated was coagulase-negative Staphylococcus in 21 TEAs (62%). A second-stage procedure was performed for 26 TEAs (76%); seven patients (seven TEAs, 21%) had a functional resection arthroplasty with antibiotic beads in situ and had no further surgery, one had a persistent discharge preventing further surgery. There were three recurrent infections (11.5%) in those patients who underwent a second-stage procedure. The infection presented at a mean of eight months (5 to 10) post-operatively. The mean Mayo Elbow Performance Score (MEPS) in those who underwent a second stage revision without recurrent infection was 81.1 (65 to 95). Staged revision surgery is successful in the treatment of patients with an infected TEA and is associated with a low rate of recurrent infection. However, when infection does occur, this study would suggest that it becomes apparent within ten months of the second stage procedure. Cite this article: Bone Joint J 2013;95-B:1681–6


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 668 - 671
1 May 2010
Naqui SZ Rajpura A Nuttall D Prasad P Trail IA

This is a retrospective review of the results of the Acclaim total elbow replacement in 11 older patients aged ≥ 65 years with primary osteoarthritis of the elbow, with a mean follow-up of 57.6 months (30 to 86.4). Significant reductions in pain and improvement in range of movement and function were recorded. Radiological review revealed two patients with 1 mm lucencies in a single zone, and one patient with 1 mm lucencies in two zones. No components required revision. There were no deep infections, dislocations or mechanical failures. Complications included one intra-operative medial condylar fracture and one post-operative transient ulnar neuropathy, which resolved. This study demonstrates that the Acclaim prosthesis provides good symptomatic relief and improvement of function in patients with primary osteoarthritis, with low rates of loosening or other complications. This prosthesis can therefore be considered for patients aged ≥ 65 years with primary osteoarthritis of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 351 - 353
1 Apr 2003
Espag MP Back DL Clark DI Lunn PG

We have carried out a retrospective review of 11 Souter-Strathclyde primary total elbow arthroplasties in ten patients with osteoarthritis, over a period of nine years. The diagnosis was primary osteoarthritis in nine elbows and post-traumatic arthritis in two. The mean follow-up was 68 months (15 to 117). Although no patient was symptomatic, radiological review revealed evidence of loosening affecting three humeral and two ulnar components, one of which subsequently failed and was revised at 97 months. There were no dislocations, deep infections or mechanical failures. Complications included two superficial wound infections and two neurapraxias of the ulnar nerve which resolved. This study shows that the unlinked Souter-Strathclyde total elbow arthroplasty can be considered for patients with osteoarthritis and gives good symptomatic relief and improvement in function


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 229 - 236
1 Feb 2014
deVos MJ Verdonschot N Luites JWH Anderson PG Eygendaal D

We determined the short-term clinical outcome and migration within the bone of the humeral cementless component of the Instrumented Bone Preserving (IBP) total elbow replacement in a series of 16 patients. There were four men and 12 women with a mean age at operation of 63 years (40 to 81). Migration was calculated using radiostereometric analysis. There were no intra-operative complications and no revisions. At two-year follow-up, all patients showed a significant reduction in pain and functional improvement of the elbow (both p < 0.001). Although ten components (63%) showed movement or micromovement during the first six weeks, 14 (88%) were stable at one year post-operatively. Translation was primarily found in the proximal direction (median 0.3 mm (interquartile range (IQR) -0.09 to 0.8); the major rotational movement was an anterior tilt (median 0.7° (IQR 0.4° to 1.6°)). One malaligned component continued to migrate during the second year, and one component could not be followed beyond three months because migration had caused the markers to break off the prosthesis. This study shows promising early results for the cementless humeral component of the IBP total elbow replacement. All patients had a good clinical outcome, and most components stabilised within six months of the operation. . Cite this article: Bone Joint J 2014;96-B:229–36


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 338 - 345
1 Mar 2018
Watkins CEL Elson DW Harrison JWK Pooley J

Aim. The aim of this study was to report the long-term outcome and implant survival of the lateral resurfacing elbow (LRE) arthroplasty in the treatment of elbow arthritis. Patients and Methods. We reviewed a consecutive series of 27 patients (30 elbows) who underwent LRE arthroplasty between December 2005 and January 2008. There were 15 women and 12 men, with a mean age of 61 years (25 to 82). The diagnosis was primary hypotrophic osteoarthritis (OA) in 12 patients (14 elbows), post-traumatic osteoarthritis (PTOA) in five (five elbows) and rheumatoid arthritis (RA) in ten patients (11 elbows). The mean clinical outcome scores including the Mayo Elbow Performance Score (MEPS), the American Shoulder and Elbow Surgeons elbow score (ASES-e), the mean range of movement and the radiological outcome were recorded at three, six and 12 months and at a mean final follow-up of 8.3 years (7.3 to 9.4). A one sample t-test comparing pre and postoperative values, and survival analysis using the Kaplan–Meier method were undertaken. Results. A statistically significantly increased outcome score was noted for the whole group at each time interval. This was also significantly increased at each time in each of the subgroups (OA, RA, and PTOA). Implant survivorship was 100%. Conclusion. We found that the LRE arthroplasty, which was initially developed for younger patients with osteoarthritis, is an effective form of surgical treatment for a wider range of patients with more severe degenerative changes, irrespective of their cause. It is therefore a satisfactory alternative to total elbow arthroplasty (TEA) and has lower rates of complications in the subgroups of patients we have studied. It does not require activities to be restricted to the same extent as following TEA. Based on this experience, we now recommend LRE arthroplasty rather than TEA as the primary form of implant for the treatment of patients with OA of the elbow. Cite this article: Bone Joint J 2018;100-B:338–45


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 976 - 983
1 Jul 2016
Streubel PN Simone JP Morrey BF Sanchez-Sotelo J Morrey ME

Aims. We describe the use of a protocol of irrigation and debridement (I& D) with retention of the implant for the treatment of periprosthetic infection of a total elbow arthroplasty (TEA). This may be an attractive alternative to staged re-implantation. . Patients and Methods. Between 1990 and 2010, 23 consecutive patients were treated in this way. Three were lost to follow-up leaving 20 patients (21 TEAs) in the study. There were six men and 14 women. Their mean age was 58 years (23 to 76). The protocol involved: component unlinking, irrigation and debridement (I& D), and the introduction of antibiotic laden cement beads; organism-specific intravenous antibiotics; repeat I& D and re-linkage of the implant if appropriate; long-term oral antibiotic therapy. . Results. The mean follow-up was 7.1 years (2 to 16). The infecting micro-organisms were Staphylococcus aureus in nine, coagulase-negative Staphylococcus in 13, Corynebacterium in three and other in six cases. Re-operations included three repeat staged I& Ds, two repeat superficial I& Ds and one fasciocutaneous forearm flap. One patient required removal of the implant due to persistent infection. All except three patients rated their pain as absent or mild. Outcome was rated as good or excellent in 15 patients (mean Mayo Elbow Performance Score 78 points, (5 to 100) with a mean flexion-extension arc of 103° (40° to 150°)). . Conclusion. A staged protocol can be successful in retaining stable components of an infected TEA. Function of the elbow may compare unfavourably to that after an uncomplicated TEA. Cite this article: Bone Joint J 2016;98-B:976–83


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 297 - 299
1 Mar 1992
O'Driscoll S An K Korinek S Morrey B

We used 11 cadaver elbows and a three-dimensional electromagnetic tracking device to record elbow movements before and after implantation of a 'loose-hinged' elbow prosthesis (modified Coonrad). During simulated active motion there was a maximum of 2.7 degrees (+/- 1.5 degrees) varus/valgus laxity in the cadaver joints. This increased slightly after total elbow arthroplasty to 3.8 degrees (+/- 1.4 degrees). These values are lower than those recorded for the cadaver joints and for the prostheses at the limits of their varus/valgus displacements, indicating that both behave as 'semi-constrained' joints under physiological conditions. They suggest that the muscles absorb some of the forces and moments that in a constrained prosthesis would be transferred to the prosthesis-bone interface


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 62 - 65
1 Jan 2007
Ito H Matsumoto T Yoshitomi H Kakinoki R Nakamura T

We compared the outcome of peri-operative humeral condylar fractures in patients undergoing a Coonrad-Morrey semiconstrained total elbow replacement with that of patients with rheumatoid arthritis undergoing the same procedure without fractures. In a consecutive series of 40 elbows in 33 patients, 13 elbows had a fracture in either condyle peri-operatively, and 27 elbows were intact. The fractured condyle was either fixed internally or excised. We found no statistical difference in the patients’ background, such as age, length of follow-up, immobilisation period, Larsen’s radiological grade, or Steinbrocker’s stage and functional class. There was also no statistical difference between the groups in relation to the Mayo Elbow Performance Score, muscle strength, range of movement, or radiolucency around the implants at a mean of 4.8 years (1.1 to 8.0) follow-up. We conclude that fractured condyles can be successfully treated with either internal fixation or excision, and cause no harmful effect


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 635 - 639
1 Jul 2001
Redfern DRM Dunkley AB Trail IA Stanley JK

The Souter-Strathclyde prosthesis was used in 52 revisions of total elbow replacements (TERs) between August 1986 and May 1997. Of these, 50, carried out in 45 patients, were prospectively followed for a mean of 53 months (14 to 139). The procedure produced reliable relief of pain, and the range of movement was preserved. There was a considerable incidence of adverse events associated with revision (30%), and 12 further procedures have been required. Nonetheless, a revision is the preferred salvage procedure for failed primary arthroplasty in the absence of sepsis


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 354 - 357
1 Apr 2003
Potter D Claydon P Stanley D

Between 1993 and 1996, we undertook 35 Kudo 5 total elbow replacements in a consecutive series of 31 rheumatoid patients. A total of 25 patients (29 procedures) was evaluated at a mean follow-up of six years (5 to 7.5) using the Mayo Clinic performance index. In addition, all patients were assessed for loosening using standard anteroposterior and lateral radiographs. At review, 19 elbows (65%) had either no pain or mild pain, ten (35%) had moderate pain and none had severe pain. The mean arc of flexion/extension was 94° (35 to 130) and supination/pronation was 128° (30 to 165). A fracture of the medial epicondyle occurred during surgery in one patient. This was successfully treated with a single AO screw and a standard Kudo 5 implant was inserted. Postoperatively, there were no infections. One patient had a dislocation which was treated by closed reduction and five had neurapraxia of the ulnar nerve. Radiologically, there was no evidence of loosening of the humeral component, but two ulnar components had progressive radiolucent lines suggestive of loosening. Two other ulnar components had incomplete and non-progressive radiolucent lines. With definite radiological loosening as the endpoint, the probability of survival of the Kudo 5 prosthesis at five years using the Kaplan-Meier method was 89%


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 974 - 978
1 Sep 2001
Gambirasio R Riand N Stern R Hoffmeyer P

The treatment of multifragmentary, intra-articular fractures of the distal humerus is difficult, even in young patients with bone of good quality, but is worse in elderly patients who have varying degrees of osteopenia. We have evaluated the functional outcome of primary total elbow replacement (TER) in the treatment of these fractures in ten elderly patients followed for a minimum of one year. There were no complications in regard to the soft tissues, bone or prosthesis. The mean range of flexion obtained was 125° (110 to 140) and loss of extension was 23.5° (0 to 50). The mean Mayo score was 94 points (80 to 100) and patient satisfaction was high. We feel that TER provides an alternative to open reduction and internal fixation in the management of these complicated fractures in the elderly


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 636 - 640
1 Jul 1994
Kraay M Figgie M Inglis A Wolfe S Ranawat C

We used survival analysis to evaluate 113 consecutive semiconstrained total elbow arthroplasties (TEAs) in 95 patients at a maximum follow-up of 99 months. Our criteria for failure were mechanical malfunction, revision for any reason, and deep infection. The primary diagnosis was inflammatory arthritis in 86 elbows, post-traumatic arthritis in 6, supracondylar nonunion or fracture in 12, osteoarthritis in 2 and other causes in 3. Seven failures were due to deep infection, and five of these had a primary diagnosis of inflammatory arthritis. Eight failures were revised or had revision recommended for aseptic loosening, and six of these were in patients with post-traumatic arthritis or supracondylar nonunion. The cumulative survival for TEAs performed for post-traumatic arthritis, fractures or supracondylar nonunion was 73% at three years and 53% at five years, significantly worse than the cumulative three- and five-year survivals of 92% and 90%, respectively, for patients with inflammatory arthritis. TEA with a semiconstrained prosthesis appears to have a satisfactory survival in selected patients with arthritic disorders. The incidence of deep infection was reduced by improvements in surgical technique and postoperative management, and the routine use of antibiotic-impregnated cement. The incidence of aseptic loosening was low, except in patients with supracondylar nonunion or post-traumatic arthritis


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 381 - 386
1 Mar 2016
Prasad N Ali A Stanley D

Aims

We review our experience of Coonrad-Morrey total elbow arthroplasty (TEA) for fractures of the distal humerus in non-rheumatoid patients with a minimum of ten years follow-up.

Patients and Methods

TEA through a triceps splitting approach was peformed in 37 non-rheumatoid patients for a fracture of the distal humerus between 1996 and 2004. One patient could not be traced and 17 had died before the tenth anniversary of their surgery. This left 19 patients with a minimum follow-up of ten years to form the study group. Of these, 13 patients were alive at the time of final review. The other six had died, but after the tenth anniversary of their elbow arthroplasty. Their clinical and radiological data were included in the study.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 437 - 444
1 Apr 2005
Little CP Graham AJ Carr AJ


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 920 - 924
1 Jul 2006
Mori T Kudo H Iwano K Juji T

We studied 11 patients (14 elbows) with gross rheumatoid deformity of the elbow, treated by total arthroplasty using the Kudo type-5 unlinked prosthesis, and who were evaluated between five and 11 years after operation. Massive bone defects were augmented by autogenous bone grafts. There were no major complications such as infection, subluxation or loosening. In most elbows relief from pain and stability were achieved. The results, according to the Mayo Elbow Performance Score, were excellent in eight, good in five and fair in one. In most elbows there was minimal or no resorption of the grafted bone. There were no radiolucent lines around the stems of the cementless components. This study shows that even highly unstable rheumatoid elbows can be replaced successfully using an unlinked prosthesis, with augmentation by grafting for major defects of bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 78 - 83
1 Jan 2006
Sneftrup SB Jensen SL Johannsen HV Søjbjerg JO

We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with complications occurring in 13 cases.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 82 - 87
1 Jan 2014
Duquin TR Jacobson JA Schleck CD Larson DR Sanchez-Sotelo J Morrey BF

Treatment of an infected total elbow replacement (TER) is often successful in eradicating or suppressing the infection. However, the extensor mechanism may be compromised by both the infection and the surgery. The goal of this study was to assess triceps function in patients treated for deep infection complicating a TER. Between 1976 and 2007 a total of 217 TERs in 207 patients were treated for infection of a TER at our institution. Superficial infections and those that underwent resection arthroplasty were excluded, leaving 93 TERs. Triceps function was assessed by examination and a questionnaire. Outcome was measured using the Mayo Elbow Performance Score (MEPS).

Triceps weakness was identified in 51 TERs (49 patients, 55%). At a mean follow-up of five years (0.8 to 34), the extensor mechanism was intact in 13 patients, with the remaining 38 having bone or soft-tissue loss. The mean MEPS was 70 points (5 to 100), with a mean functional score of 18 (0 to 25) of a possible 25 points.

Infection following TER can often be eradicated; however, triceps weakness occurs in more than half of the patients and may represent a major functional problem.

Cite this article: Bone Joint J 2014;96-B:82–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1129 - 1134
1 Nov 2000
Rozing P

We have reviewed 66 consecutive Souter-Strathclyde arthroplasties of the elbow implanted in 59 patients between 1982 and 1993. Thirteen patients (15 elbows) (19.6%) died. Sixteen elbows (24.2%) were revised, six for aseptic loosening (9%), four (6%) because of fracture or loosening after a fracture, three (4.5%) for infection and three (4.5%) for dislocation. Four patients refused to attend for review.

In 33 elbows with a follow-up of 93 months (60 to 167) complete relief of pain was achieved in 22 (67%) when seen at one year. After ten years or more 36% of the elbows were painfree and 64% had occasional slight pain especially under loading or stress. The mean gain in the arc of movement was 16°, but a mean flexion contracture of 33° remained. The main early complications were intraoperative fractures of the epicondyles (9%), postoperative dislocation (4.5%) and ulnar neuropathy. The incidence of ulnar neuropathy before operation was 19%. After operation 20 patients (33%) had an ulnar neuropathy, in seven of which it had been present before operation, and of these weakness of the hypothenar muscle occurred in two. The probability of survival of the Souter-Strathclyde elbow prosthesis based on the Kaplan-Meier calculation is 69% at ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 705 - 710
1 Jul 2000
Yanni ON Fearn CBD Gallannaugh SC Joshi R

We report the results of a series of 59 unconstrained total arthroplasties of the elbow after a mean follow-up of 6.5 years (4 to 10). All the patients had rheumatoid arthritis. The indication for surgery was pain in all but one. Outcome was assessed by the Mayo Elbow Performance Index (MEPI).

Of the 59 arthroplasties, two were lost to follow-up. Ten patients died, but as two of their arthroplasties were failures we included them in the results. The outcome in the remaining 49 was excellent in 26 (53%), good in 15 (31%), fair in one (2%) and poor or a failure in seven (14%). There was an improvement in the pain score (p < 0.001), movement (p < 0.001) and function (p < 0.001). Two patients developed instability, but neither required further surgery. There was a mean increase of 21° in flexion and of 7° in extension.

The overall rate of complications was 33.9%. Lesions of the ulnar nerve, one of which did not recover, occurred in four patients, deep infection in two and stiffness in five. The rates of complications were similar to those in recent reports of other elbow arthroplasties.

We carried out a radiological analysis of 39 arthroplasties which showed radiolucent lines around the humeral component in 22 and the ulnar component in 15. There were lower scores on the MEPI for those with radiolucent lines around the humeral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 80 - 84
1 Jan 1999
Trail IA Nuttall D Stanley JK

We undertook a radiological analysis of 186 standard Souter implants to determine survivorship and to analyse the pattern of failure in those needing revision. The implants had been inserted as a primary procedure in patients with rheumatoid arthritis of the elbow at our hospital over the last 12 years.

Taking revision as an endpoint, the survivorship after 12 years was 87%. If, however, revision and loosening, defined as the Hindex value equivalent to demarcation of 1 mm around the whole implant, are also included, the survivorship falls to 80%. Of the 24 implants revised, 18 (75%) were for problems with the humeral component, three (12.5%) with the ulnar component and three (12.5%) for instability.

Loosening of the humeral component occurred when the implant extended into the humerus, with the tip moving anteriorly on to the anterior humeral cortex. Our study indicates that loosening can be predicted by the rate of change in this angle of extension of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 80 - 85
1 Jan 2012
Malone AA Sanchez JS Adams R Morrey B

We report the effectiveness of revision of total elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows in 52 patients were treated with re-cementing of a total elbow replacement into part or all of the existing cement mantle or into the debrided host-bone interface, without the use of structural bone augmentation or a custom prosthesis. The original implant revision was still in situ and functional in 42 of 53 elbows (79%) at a mean of 94.5 months (26 to 266) after surgery. In 31 of these 42 elbows (74%) the Mayo Elbow Performance Score was good or excellent. Overall, of the 53 elbows, 18 (34%) required re-operation, ten (19%) for loosening. A classification system was developed to identify those not suitable for revision by this technique, and using this we have showed that successful re-implantation is statistically correlated to properly addressing the bone deficiency for both the humeral (p = 0.005) and the ulnar (p = 0.039) components.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1148 - 1155
1 Oct 2022
Watts AC Hamoodi Z McDaid C Hewitt C

Aims. Arthroplasties of the elbow, including total elbow arthroplasty, radial head arthroplasty, distal humeral hemiarthroplasty, and radiocapitellar arthroplasty, are rarely undertaken. This scoping review aims to outline the current research in this area to inform the development of future research. Methods. A scoping review was undertaken adhering to the Joanna Briggs Institute guidelines using Medline, Embase, CENTRAL, and trial registries, limited to studies published between 1 January 1990 and 7 February 2021. Endnote software was used for screening and selection, and included randomized trials, non-randomized controlled trials, prospective and retrospective cohort studies, case-control studies, analytical cross-sectional studies, and case series of ten or more patients reporting the clinical outcomes of elbow arthroplasty. The results are presented as the number of types of studies, sample size, length of follow-up, clinical outcome domains and instruments used, sources of funding, and a narrative review. Results. A total of 362 studies met the inclusion criteria. Most were of total elbow arthroplasty (246; 68%), followed by radial head arthroplasty (100; 28%), distal humeral hemiarthroplasty (11; 3%), and radiocapitellar arthroplasty (5; 1%). Most were retrospective (326; 90%) and observational (315; 87%). The median sample size for all types of implant across all studies was 36 (interquartile range (IQR) 21 to 75). The median length of follow-up for all studies was 56 months (IQR 36 to 81). A total of 583 unique outcome descriptors were used and were categorized into 18 domains. A total of 105 instruments were used to measure 39 outcomes. Conclusion. We found that most of the literature dealing with elbow arthroplasty consists of retrospective observational studies with small sample sizes and short follow-up. Many outcomes have been used with many different instruments for their measurement, indicating a need to define a core set of outcomes and instruments for future research in this area. Cite this article: Bone Joint J 2022;104-B(10):1148–1155


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 191 - 195
1 Feb 2005
Mighell MA Dunham RC Rommel EA Frankle MA

We present six patients with chronic dislocation of the elbow who were treated by primary semiconstrained total elbow arthroplasty. All were women with a mean age of 65 years (51 to 76), the mean interval between dislocation and surgery was 17 weeks (5 to 52) and the mean follow-up 58 months (24 to 123). The most dramatic improvement was in function. The mean American Shoulder and Elbow Surgeon score was 5.2 times better (p < 0.001) and the mean total range of movement increased from 33° to 121° (p < 0.001) after operation. Three patients developed wear of polyethylene. One required revision for a periprosthetic fracture, and another required a bushing exchange. Primary semiconstrained elbow arthroplasty provides significant, predictable functional improvement. Potential solutions for wear of polyethylene include a different operative technique or design of implant. Despite the high incidence of such wear, total elbow arthroplasty should be considered as a viable treatment option for chronic dislocation of the elbow in elderly patients


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function. No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%)


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1132 - 1138
1 Aug 2015
Aitken SA Jenkins PJ Rymaszewski L

The best method of managing a fracture of the distal humerus in a frail low-demand patient with osteoporotic bone remains controversial. Total elbow arthroplasty (TEA) has been recommended for patients in whom open reduction and internal fixation (ORIF) is not possible. Conservative methods of treatment, including the ‘bag of bones’ technique (acceptance of displacement of the bony fragments and early mobilisation), are now rarely considered as they are believed to give a poor functional result. We reviewed 40 elderly and low-demand patients (aged 50 to 93 years, 72% women) with a fracture of the distal humerus who had been treated conservatively at our hospital between March 2008 and December 2013, and assessed their short- and medium-term functional outcome. . In the short-term, the mean Broberg and Morrey score improved from 42 points (poor; 23 to 80) at six weeks after injury to 67 points (fair; 40 to 88) by three months. . In the medium-term, surviving patients (n = 20) had a mean Oxford elbow score of 30 points (7 to 48) at four years and a mean Disabilities of the Arm, Shoulder and Hand score of 38 points (0 to 75): 95% reported a functional range of elbow flexion. The cumulative rate of fracture union at one year was 53%. The mortality at five years approached 40%. . Conservative management of a fracture of the distal humerus in a low-demand patient only gives a modest functional result, but avoids the substantial surgical risks associated with primary ORIF or TEA. Cite this article: Bone Joint J 2015;97-B:1132–8


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 16 - 22
1 Jan 2012
Popovic D King GJW

In light of the growing number of elderly osteopenic patients with distal humeral fractures, we discuss the history of their management and current trends. Under most circumstances operative fixation and early mobilisation is the treatment of choice, as it gives the best results. The relative indications for and results of total elbow replacement versus internal fixation are discussed


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1359 - 1365
1 Oct 2014
Large R Tambe A Cresswell T Espag M Clark DI

Medium-term results of the Discovery elbow replacement are presented. We reviewed 51 consecutive primary Discovery total elbow replacements (TERs) implanted in 48 patients. The mean age of the patients was 69.2 years (49 to 92), there were 19 males and 32 females (37%:63%) The mean follow-up was 40.6 months (24 to 69). A total of six patients were lost to follow-up. Statistically significant improvements in range movement and Oxford Elbow Score were found (p < 0.001). Radiolucent lines were much more common in, and aseptic loosening was exclusive to, the humeral component. Kaplan–Meier survivorship at five years was 92.2% (95% CI 74.5% to 96.4%) for aseptic loosening. In four TERs, periprosthetic infection occurred resulting in failure. A statistically significant association between infection and increased BMI was found (p = 0.0268). Triceps failure was more frequent after the Mayo surgical approach and TER performed after previous trauma surgery. No failures of the implant were noted. . Our comparison shows that the Discovery has early clinical results that are similar to other semi-constrained TERs. We found continued radiological surveillance with particular focus on humeral lucency is warranted and has not previously been reported. Despite advances in the design of total elbow replacement prostheses, rates of complication remain high. Cite this article: Bone Joint J 2014;96-B:1359–65


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1377 - 1384
1 Oct 2015
Nestorson J Ekholm C Etzner M Adolfsson L

We report our experience of performing an elbow hemiarthroplasty in the treatment of comminuted distal humeral fractures in the elderly patients. A cohort of 42 patients (three men and 39 women, mean age 72; 56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after surgery. Functional outcome was measured with the Mayo Elbow Performance Score (MEPS) and range of movement. The disabilities of the arm, shoulder and hand questionnaire (DASH) was used as a patient rated evaluation. Complications and ulnar nerve function were recorded. Plain radiographs were obtained to assess prosthetic loosening, olecranon wear and heterotopic bone formation. The mean extension deficit was 23.5° (0° to 60°) and mean flexion was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°). The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0 to 63). Four patients had additional surgery for limited range of movement and one for partial instability. One elbow was revised due to loosening, two patients had sensory ulnar nerve symptoms, and radiographic signs of mild olecranon wear was noted in five patients. Elbow hemiarthroplasty for comminuted intra-articular distal humeral fractures produces reliable medium-term results with functional outcome and complication rates, comparable with open reduction and internal fixation and total elbow arthroplasty. Cite this article: Bone Joint J 2015;97-B:1377–84


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1273 - 1277
1 Sep 2010
Larson AN Adams RA Morrey BF

Between 1996 and 2008, nine patients with severe post-traumatic arthritis underwent revision of a failed interposition arthroplasty of the elbow with a further interposition procedure using an allograft of tendo Achillis at a mean of 5.6 years (0.7 to 13.1) after the initial procedure. There were eight men and one woman with a mean age of 47 years (36 to 56). The mean follow-up was 4.7 years (2 to 8). The mean Mayo Elbow Performance score improved from 49 (15 to 65) pre-operatively to 73 (55 to 95) (p = 0.04). The mean Disability of the Arm, Shoulder and Hand score was 26 (7 to 42). One patient was unavailable for clinical follow-up and one underwent total elbow replacement three months post-operatively. Of the remaining patients, one had an excellent, two had good, three fair and one a poor result. Subjectively, five of the nine patients were satisfied. Four continued manual labour. Revision interposition arthroplasty is an option for young, active patients with severe post-traumatic arthritis who require both mobility and durability of the elbow


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims

The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection.

Methods

From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 812 - 816
1 Aug 2002
Garcia JA Mykula R Stanley D

Between 1995 and 2000, 19 consecutive patients with fractures of the distal humerus were treated by primary total elbow replacement using the Coonrad-Morrey prosthesis. No patient had inflammatory or degenerative arthritis of the elbow. The mean age at the time of injury was 73 years (61 to 95). According to the AO classification, 11 patients had suffered a C3 injury, two a B3 and two an A3. One fracture was unclassified. Two patients died from unrelated causes and one was unable to be assessed because of concurrent illness. The mean time to follow-up was three years (1 to 5.5). At follow-up 11 patients (68%) reported no pain, four (25%) had mild pain with activity and one had mild pain at rest. The mean flexion arc was 24° to 125°. The mean supination was 90° (70 to 100) and pronation 70° (50 to 110). No elbow was unstable. The mean Disabilities of the Arm, Shoulder and Hand score was 23 (0.92 to 63.3) and the mean Mayo elbow performance score was 93 (80 to 100). Of the 16 patients, 15 were satisfied with the outcome. Radiological evaluation revealed only one patient with a radiolucent line at the cement-bone interface. It was between 1 and 2 mm in length, was present on the initial postoperative radiograph and was non-progressive at the time of follow-up. Primary total elbow arthroplasty is an acceptable option for the management of comminuted fractures of the distal humerus in elderly patients when the configuration of the fracture and the quality of the bone make reconstruction difficult


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1382 - 1388
1 Oct 2011
Amirfeyz R Stanley D

We studied, ten patients (11 elbows) who had undergone 14 allograft-prosthesis composite reconstructions following failure of a previous total elbow replacement with massive structural bone loss. There were nine women and one man with a mean age of 64 years (40 to 84), who were reviewed at a mean of 75 months (24 to 213). One patient developed a deep infection after 26 months and had the allograft-prosthesis composite removed, and two patients had mild pain. The median flexion-extension arc was 100° (95% confidence interval (CI) 76° to 124°). With the exception of the patient who had the infected failure, all the patients could use their elbows comfortably without splints or braces for activities of daily living. The mean Mayo Elbow Performance Index improved from 9.5 (95% CI 4.4 to 14.7) pre-operatively to 74 (95% CI 62.4 to 84.9) at final review. Radiologically, the rate of partial resorption was similar in the humeral and ulnar allografts (three of six and four of eight, respectively; p > 0.999). The patterns of resorption, however, were different. Union at the host-bone-allograft junction was also different between the humeral and ulnar allografts (one of six and seven of eight showing union, respectively; p = 0.03). At medium-term follow-up, allograft-prosthesis composite reconstruction appears to be a useful salvage technique for failed elbow replacements with massive bone loss. The effects of allograft resorption and host-bone-allograft junctional union on the longevity of allograft-prosthesis composite reconstruction, however, remain unknown, and it is our view that these patients should remain under long-term regular review


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 486 - 494
4 Apr 2022
Liu W Sun Z Xiong H Liu J Lu J Cai B Wang W Fan C

Aims

The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow.

Methods

We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1098 - 1103
1 Aug 2011
Ruggieri P Mavrogenis AF Guerra G Mercuri M

We retrospectively studied 14 patients with proximal and diaphyseal tumours and disappearing bone (Gorham’s) disease of the humerus treated with wide resection and reconstruction using an allograft-resurfacing composite (ARC). There were ten women and four men, with a mean age of 35 years (8 to 69). At a mean follow-up of 25 months (10 to 89), two patients had a fracture of the allograft. In one of these it was revised with a similar ARC and in the other with an intercalary prosthesis. A further patient had an infection and a fracture of the allograft that was revised with a megaprosthesis. In all patients with an ARC, healing of the ARC-host bone interface was observed. One patient had failure of the locking mechanism of the total elbow replacement. The mean post-operative Musculoskeletal Tumor Society score for the upper extremity was 77% (46.7% to 86.7%), which represents good and excellent results; one patient had a poor result (46.7%). In the short term ARC effectively relieves pain and restores shoulder function in patients with wide resection of the proximal humerus. Fracture and infection remain significant complications


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 732 - 736
1 Nov 1984
Johnson Getty C Lettin A Glasgow M

Between 1970 and 1982, 50 total elbow replacements were carried out for rheumatoid arthritis using the Stanmore prosthesis. A long-term follow-up of the 44 elbows available for review is presented. Thirty-four of these (77%) had good results, five were fair, and five were poor. The complications and limitations are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1020 - 1022
1 Nov 1999
Shahane SA Stanley D

We describe a posterior approach to the elbow which combines the advantages of both splitting and reflecting the triceps. It gives protection to the ulnar nerve and its blood supply during the operation while providing excellent exposure of the distal humerus. During closure, the triceps muscle can be tensioned, thereby improving stability of the elbow. This approach has particular relevance to unlinked total elbow arthroplasty allowing early rehabilitation of the joint


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1138 - 1140
1 Nov 2003
Chapman-Sheath PJ Giangrande P Carr AJ

Total elbow replacement can be a valuable option for the treatment of the elbow in haemophilia where there are associated arthropathic changes. We describe the outcome of seven elbow replacements in five consecutive patients with severe haemophilia A (native factor levels < 1%) at a mean of 42 months (25 to 65) after operation. All the patients had excellent relief of pain and improvement in function. One failure was due to infection in an immunocompromised patient with both HIV and Hepatitis C antibodies who was on anti-retroviral chemotherapy. The implant was revised at 30 months in a one-stage procedure and showed no evidence of loosening or infection 35 months later


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 243 - 247
1 Mar 1984
Lowe L Miller A Allum R Higginson D

This paper describes the development, operative technique and results of an unconstrained total elbow arthroplasty. Forty-seven elbow replacements were carried out in 44 patients between 1974 and 1982. There was a high rate of loosening in the early condylar replacements. The results in patients with post-traumatic arthritis were poor. The later design employs an ulnar stem, with a humeral stem if the distal humeral bone stock is poor. When used in carefully selected patients with rheumatoid arthritis, pain is reduced significantly, stability and movement are preserved and function is improved


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 622 - 626
1 Jul 1994
Cobb T Linscheid R

We treated three patients with malunion after comminuted intercondylar fractures of the humerus by intra-articular derotational opening-wedge osteotomy and the insertion of a tricortical iliac bone graft. Two patients required additional operations, including interposition arthroplasty and hardware removal. A mean arc of increased motion of 65 degrees was achieved in flexion and extension in two patients and a more functional arc in the third. Although this is viewed as a salvage procedure in patients who are thought to be too young for elbow arthroplasty, none of the three patients has significant pain and none has required total elbow arthroplasty after an average follow-up of 7.6 years


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 770 - 772
1 Sep 1997
Lee BPH Morrey BF

The short-term assessment of 14 arthroscopic synovectomies of the elbow in 11 patients with rheumatoid arthritis showed that 93% achieved a short-term rating of excellent or good on the Mayo Elbow Performance Score. At the most recent assessment at an average of 42 months, however, only 57% maintained excellent or good results; four had required total elbow replacement. Although rehabilitation is facilitated by an arthroscopic procedure the results deteriorate more rapidly than after open synovectomy. This may be due to the limitations of the arthroscopic technique and is consistent with experience of the similar procedure in the knee. Recognition of the short-term gain and the potential for serious nerve injury should be considered when offering arthroscopic synovectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 652 - 655
1 Aug 1987
Ross A Sneath R Scales J

Between 1969 and 1985 26 patients with destructive lesions of the distal humerus were treated by endoprosthetic replacement; each implant was custom-made and incorporated part of the distal humerus or the entire bone as well as a hinged total elbow replacement. Recurrence occurred in three of the patients with tumours, and three prostheses were removed because of deep infection in patients with previously compound injuries of the elbow. Another three loosened without infection, but none needed revision or removal and no amputations resulted. Other complications included nerve palsies, but the only deaths were from metastases. A useful range of elbow movement, with a stable arm and good hand function, was achieved in every patient


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 366 - 372
1 Feb 2021
Sun Z Li J Luo G Wang F Hu Y Fan C

Aims

This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the Mayo Elbow Performance Index (MEPI) and range of movement (ROM) after open elbow arthrolysis (OEA). We also assessed the proportion of patients who achieved MCID and SCB; and identified the factors associated with achieving MCID.

Methods

A cohort of 265 patients treated by OEA were included. The MEPI and ROM were evaluated at baseline and at two-year follow-up. Distribution-based MDC was calculated with confidence intervals (CIs) reflecting 80% (MDC 80), 90% (MDC 90), and 95% (MDC 95) certainty, and MCID with changes from baseline to follow-up. Anchor-based MCID (anchored to somewhat satisfied) and SCB (very satisfied) were calculated using a five-level Likert satisfaction scale. Multivariate logistic regression of factors affecting MCID achievement was performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 233 - 238
1 Mar 2000
Cheng SL Morrey BF

Between 1986 and 1994, 13 patients with mobile painful arthritic elbows were treated by distraction interposition arthroplasty using fascia lata. The mean period of follow-up was 63 months. An elbow distractor/fixator was applied for three to four weeks to separate the articular surfaces and to protect the fascial graft. Nine of the 13 patients (69%) had satisfactory relief from pain; eight (62%) had an excellent or good result by the objective criteria of the Mayo Elbow Performance score. Four have required revision to total elbow arthroplasty at a mean of 30 months with good results to date. Instability of the elbow, both before and after surgery, was found to be associated with unsatisfactory results. The rate of success when the procedure was performed for inflammatory arthritis was similar to that for post-traumatic arthritis, about 67%. Eight complications occurred in six patients, all in the group with post-traumatic arthritis. Two of these required further surgical procedures such as transposition of the ulnar nerve or repair of hernia of the fascia lata. Although less reliable than prosthetic replacement, distraction interposition arthroplasty is a useful option in the treatment of young, high-demand patients with arthritis of the elbow. It is rarely indicated in the presence of generalised inflammatory arthritis, but may be of value in those patients in whom the disease is limited primarily to the elbow


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims

To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes.

Methods

Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 273 - 275
1 Mar 2020
Ahmed SS Haddad FS


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1362 - 1369
1 Nov 2019
Giannicola G Calella P Bigazzi P Mantovani A Spinello P Cinotti G

Aims

The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up.

Patients and Methods

A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1176 - 1182
1 Sep 2017
Berger P Van Cauter M Driesen R Neyt J Cornu O Bellemans J

Aims

The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS).

Patients and Methods

A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims

We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA).

Materials and Methods

We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1382 - 1389
1 Oct 2012
Sewell MD Kang SN Al-Hadithy N Higgs DS Bayley I Falworth M Lambert SM

There is little information about the management of peri-prosthetic fracture of the humerus after total shoulder replacement (TSR). This is a retrospective review of 22 patients who underwent a revision of their original shoulder replacement for peri-prosthetic fracture of the humerus with bone loss and/or loose components. There were 20 women and two men with a mean age of 75 years (61 to 90) and a mean follow-up 42 months (12 to 91): 16 of these had undergone a previous revision TSR. Of the 22 patients, 12 were treated with a long-stemmed humeral component that bypassed the fracture. All their fractures united after a mean of 27 weeks (13 to 94). Eight patients underwent resection of the proximal humerus with endoprosthetic replacement to the level of the fracture. Two patients were managed with a clam-shell prosthesis that retained the original components. The mean Oxford shoulder score (OSS) of the original TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival using re-intervention for any reason as the endpoint was 91% (95% confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at one and five years, respectively.

There were two revisions for dislocation of the humeral head, one open reduction for modular humeral component dissociation, one internal fixation for nonunion, one trimming of a prominent screw and one re-cementation for aseptic loosening complicated by infection, ultimately requiring excision arthroplasty. Two patients sustained nerve palsies.

Revision TSR after a peri-prosthetic humeral fracture associated with bone loss and/or loose components is a salvage procedure that can provide a stable platform for elbow and hand function. Good rates of union can be achieved using a stem that bypasses the fracture. There is a high rate of complications and function is not as good as with the original replacement.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1539 - 1545
1 Nov 2015
Lenoir H Chammas M Micallef JP Lazerges C Waitzenegger T Coulet B

Determining and accurately restoring the flexion-extension axis of the elbow is essential for functional recovery after total elbow arthroplasty (TEA). We evaluated the effect of morphological features of the elbow on variations of alignment of the components at TEA. Morphological and positioning variables were compared by systematic CT scans of 22 elbows in 21 patients after TEA.

There were five men and 16 women, and the mean age was 63 years (38 to 80). The mean follow-up was 22 months (11 to 44).

The anterior offset and version of the humeral components were significantly affected by the anterior angulation of the humerus (p = 0.052 and p = 0.004, respectively). The anterior offset and version of the ulnar components were strongly significantly affected by the anterior angulation of the ulna (p < 0.001 and p < 0.001).

The closer the anterior angulation of the ulna was to the joint, the lower the ulnar anterior offset (p = 0.030) and version of the ulnar component (p = 0.010). The distance from the joint to the varus angulation also affected the lateral offset of the ulnar component (p = 0.046).

Anatomical variations at the distal humerus and proximal ulna affect the alignment of the components at TEA. This is explained by abutment of the stems of the components and is particularly severe when there are substantial deformities or the deformities are close to the joint.

Cite this article: Bone Joint J 2015;97-B:1539–45.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 78 - 83
1 Jan 2008
Schwab JH Healey JH Athanasian EA

We describe a consecutive series of five patients with bone or soft-tissue sarcomas of the elbow and intra-articular extension treated by complex soft tissue, allograft bone and prosthetic joint replacement after wide extra-articular en bloc excision. All had a pedicled myocutaneous latissimus dorsi rotation flap for soft-tissue cover and reconstruction of the triceps. Wide negative surgical margins were obtained in all five patients. No local wound complications or infections were seen. There were no local recurrences at a mean follow-up of 60 months (20 to 105). The functional results were excellent in four patients and good in one. Longer term follow-up is necessary to confirm the durability of the elbow reconstruction.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 946 - 949
1 Jul 2005
Talwalkar SC Givissis PK Trail IA Nuttall D Stanley JK

We divided 309 patients with an inflammatory arthritis who had undergone primary elbow replacement using the Souter-Strathclyde implant into two groups according to their age. The mean follow-up in the older group (mean age 64 years) was 7.3 years while in the younger patients (mean age 42 years) it was 12 years. Survivorship for three different failure end-points (revision, revision because of aseptic loosening of the humeral component, and gross loosening of the humeral implant), was compared in both groups.

Our findings showed that there was no significant difference in the incidence of loosening when young rheumatoid patients were compared with an older age group.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted.

Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:681–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1407 - 1407
1 Oct 2006


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1561 - 1565
1 Nov 2014
Park JW Kim YS Yoon JO Kim JS Chang JS Kim JM Chun JM Jeon IH

Non-tuberculous mycobacterial (NTM) infection of the musculoskeletal tissue is a rare disease. An early and accurate diagnosis is often difficult because of the indolent clinical course and difficulty of isolating pathogens. Our goal was to determine the clinical features of musculoskeletal NTM infection and to present the treatment outcomes. A total of 29 patients (nine females, 20 males between 34 and 85 years old, mean age 61.7 years; 34 to 85) with NTM infection of the musculoskeletal system between 1998 to 2011 were identified and their treatment retrospectively analysed. Microbiological studies demonstrated NTM in 29 patients: the isolates were Mycobacterium intracellulare in six patients, M. fortuitum in three, M. abscessus in two and M. marinum in one. In the remaining patients we failed to identify the species. The involved sites were the hand/wrist in nine patients the knee in five patients, spine in four patients, foot in two patients, elbow in two patients, shoulder in one, ankle in two patients, leg in three patients and multiple in one patient. The mean interval between the appearance of symptoms and diagnosis was 20.8 months (1.5 to 180). All patients underwent surgical treatment and antimicrobial medication according to our protocol for chronic musculoskeletal infection: 20 patients had NTM-specific medication and nine had conventional antimicrobial therapy. At the final follow-up 22 patients were cured, three failed to respond to treatment and four were lost to follow-up. Identifying these diseases due the initial non-specific presentation can be difficult. Treatment consists of surgical intervention and adequate antimicrobial therapy, which can result in satisfactory outcomes.

Cite this article: Bone Joint J 2014;96-B:1561–5.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1252 - 1257
1 Sep 2014
Habib M Tanwar YS Jaiswal A Singh SP Sinha S lal H

In order to achieve satisfactory reduction of complex distal humeral fractures, adequate exposure of the fracture fragments and the joint surface is required. Several surgical exposures have been described for distal humeral fractures. We report our experience using the anconeus pedicle olecranon flip osteotomy approach. This involves detachment of the triceps along with a sliver of olecranon, which retains the anconeus pedicle. We report the use of this approach in ten patients (six male, four female) with a mean age of 38.4 years (28 to 51). The mean follow-up was 15 months (12 to 18) with no loss to follow-up. Elbow function was graded using the Mayo Score. The results were excellent in four patients, good in five and fair in one patient. The mean time to both fracture and osteotomy union was 10.6 weeks (8 to 12) and 7.1 weeks (6 to 8), respectively. We found this approach gave reliably good exposure for these difficult fractures enabling anatomical reduction and bicondylar plating without complications.

Cite this article: Bone Joint J 2014;96-B:1252–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 552 - 556
1 Apr 2009
Hannouche D Ballis R Raould A Nizard RS Masquelet AC

We describe a lateral approach to the distal humerus based on initial location of the superficial branches of the radial nerve, the inferior lateral cutaneous nerve of the arm and the posterior cutaneous nerve of the forearm. In 18 upper limbs the superficial branches of the radial nerve were located in the subcutaneous tissue between the triceps and brachioradialis muscles and dissected proximally to their origin from the radial nerve, exposing the shaft of the humerus. The inferior lateral cutaneous nerve of the arm arose from the radial nerve at the lower part of the spiral groove, at a mean of 14.2 cm proximal to the lateral epicondyle. The posterior cutaneous nerve of the forearm arose from the inferior lateral cutaneous nerve at a mean of 6.9 cm (6.0 to 8.1) proximal to the lateral epicondyle and descended vertically along the dorsal aspect of the forearm. The size and constant site of emergence between the triceps and brachioradialis muscles constitute a readily identifiable landmark to explore the radial nerve and expose the humeral shaft.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 632 - 635
1 May 2009
Adams JE Hoskin TL Morrey BF Steinmann SP

A series of 103 acute fractures of the coronoid process of the ulna in 101 patients was reviewed to determine their frequency. The Regan-Morrey classification, treatment, associated injuries, course and outcomes were evaluated. Of the 103 fractures, 34 were type IA, 17 type IB, ten type IIA, 19 type IIB, ten type IIIA and 13 type IIIB. A total of 44 type-I fractures (86%) were treated conservatively, while 22 type-II (76%) and all type-III fractures were managed by operation.

At follow-up at a mean of 3.4 years (1 to 8.9) the range of movement differed significantly between the types of fracture (p = 0.002). Patients with associated injuries had a lower Mayo elbow performance score (p = 0.03), less extension (p = 0.03), more pain (p = 0.007) and less pronosupination (p = 0.004), than those without associated injuries. The presence of a fracture of the radial head had the greatest effect on outcome. An improvement in outcome relative to that of a previous series was noted, perhaps because of more aggressive management and early mobilisation. While not providing complete information about the true details of a fracture and its nature, the Regan-Morrey classification is useful as a broad index of severity and prognosis.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 820 - 824
1 Jun 2013
Zsoldos CM Basamania CJ Bal GK

Gunshot injuries to the shoulder are rare and difficult to manage. We present a case series of seven patients who sustained a severe shoulder injury to the non-dominant side as a result of a self-inflicted gunshot wound. We describe the injury as ‘suicide shoulder’ caused by upward and outward movement of the gun barrel as the trigger is pulled. All patients were male, with a mean age of 32 years (21 to 48). All were treated at the time of injury with initial repeated debridement, and within four weeks either by hemiarthroplasty (four patients) or arthrodesis (three patients). The hemiarthroplasty failed in one patient after 20 years due to infection and an arthrodesis was attempted, which also failed due to infection. Overall follow-up was for a mean of 26 months (12 to 44). All four hemiarthroplasty implants were removed with no feasible reconstruction ultimately possible, resulting in a poor functional outcome and no return to work. In contrast, all three primary arthrodeses eventually united, with two patients requiring revision plating and grafting. These patients returned to work with a good functional outcome. We recommend arthrodesis rather than replacement as the treatment of choice for this challenging injury.

Cite this article: Bone Joint J 2013;95-B:820–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 672 - 676
1 May 2005
Thomas S Price AJ Sankey RA Thomas M

Replacement of the shoulder in juvenile idiopathic arthritis is not often performed and there have been no published series to date.

We present nine glenohumeral hemiarthroplasties in eight patients with systemic or polyarticular juvenile idiopathic arthritis. The mean follow-up was six years (59 to 89 months). The mean age at the time of surgery was 32 years. Surgery took place at a mean of 27 years after diagnosis. The results indicated excellent relief from pain. There was restoration of useful function which deteriorated with time, in part because of progression of the systemic disease in this severely affected group. No patient has required revision to date and there has been no radiological evidence of loosening or osteolysis around the implants.

We discuss the pathoanatomical challenges unique to this group. There was very little space for a prosthetic joint and, in some cases, bony deformity and the small size necessitated the use of custom-made implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 722 - 725
1 Jun 2011
Buckley R Leighton R Trask K

The Canadian Orthopaedic Trauma Society was started in an endeavour to answer the difficult problem of obtaining enough patients to perform top-quality research into fractures. By maintaining a high standard, including randomised study design, inclusivity, open discussion among surgeons and excellent long-term follow-up, this group has become a leader in the orthopaedic research community. This annotation describes the short history, important components and spirit necessary to build a research community or team which will function well despite the difficult research environment facing individual surgeons.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 293 - 297
1 Mar 2011
Labek G Thaler M Janda W Agreiter M Stöckl B

In a systematic review, reports from national registers and clinical studies were identified and analysed with respect to revision rates after joint replacement, which were calculated as revisions per 100 observed component years.

After primary hip replacement, a mean of 1.29 revisions per 100 observed component years was seen. The results after primary total knee replacement are 1.26 revisions per 100 observed component years, and 1.53 after medial unicompartmental replacement. After total ankle replacement a mean of 3.29 revisions per 100 observed component years was seen.

The outcomes of total hip and knee replacement are almost identical. Revision rates of about 6% after five years and 12% after ten years are to be expected.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1119 - 1120
1 Aug 2008
Crowther MAA


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 661 - 667
1 May 2010
van Riet RP Sanchez-Sotelo J Morrey BF

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 92 - 97
1 Jan 2010
Kulkarni GS Kulkarni VS Shyam AK Kulkarni RM Kulkarni MG Nayak P

Arthrolysis and dynamic splinting have been used in the treatment of elbow contractures, but there is no standardised protocol for treatment of severe contractures with an arc of flexion < 30°. We present our results of radical arthrolysis with twin incisions with the use of a monolateral hinged fixator to treat very severe extra-articular contracture of the elbow. This retrospective study included 26 patients (15 males and 11 females) with a mean age of 30 years (12 to 60). The mean duration of stiffness was 9.1 months (5.4 to 18) with mean follow-up of 5.2 years (3.5 to 9.4). The mean pre-operative arc of movement was 15.6° (0° to 30°), with mean pre-operative flexion of 64.1° (30° to 120°) and mean pre-operative extension of 52.1° (10° to 90°). Post-operatively the mean arc improved to 102.4° (60° to 135°), the mean flexion improved to 119.1° (90° to 140°) and mean extension improved to 16.8° (0° to 30°) (p < 0.001). The Mayo elbow score improved from a mean of 45 (30 to 65) to 89 (75 to 100) points, and 13 had excellent, nine had good, three had fair and one had a poor result. We had one case of severe instability and one wound dehiscence which responded well to treatment. One case had deep infection with poor results which responded well to treatment.

Our findings indicate that this method is very effective in the treatment of severe elbow contracture; however, a randomised controlled study is necessary for further evaluation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 278 - 279
1 Feb 2006
Kontakis G


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 235 - 241
1 Feb 2010
van der Lugt JCT Valstar ER Witvoet-Braam SW Nelissen RGHH

Mechanical loosening which begins with early-onset migration of the prosthesis is the major reason for failure of the Souter-Strathclyde elbow replacement. In a prospective study of 18 Souter-Strathclyde replacements we evaluated the patterns of migration using roentgen stereophotogrammetric analysis. We had previously reported the short-term results after a follow-up of two years which we have now extended to a mean follow-up of 8.2 years (1 to 11.3). Migration was assessed along the co-ordinal axes and overall micromovement was expressed as the maximum total point movement. The alignment of the prosthesis and the presence of radiolucent lines were examined on conventional standardised radiographs.

All the humeral components showed increased and variable patterns of migration at the extended follow-up and four humeral components were revised. The maximum total point movement at two years in the revised prostheses was 1.8 mm (sd 1.0) and in the non-revised 0.7 mm (sd 0.5, p = 0.01). Most humeral components migrated into external rotation resulting in an anterior and varus tilt. The ulnar components remained stable.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1498 - 1503
1 Nov 2007
Hanna SA David LA Aston WJS Gikas PD Blunn GW Cannon SR Briggs TWR

Between 1988 and 2006, 18 patients had a custom-made endoprosthetic replacement of the distal humerus for bone tumours at our institution. There were 11 primary malignant neoplasms, six secondary deposits, and one benign aggressive tumour. The mean follow-up was for 4.4 years (1 to 18.2). Complications occurred in nine patients and included aseptic loosening in three (16.6%), local recurrence in two (11%), infection in two (11%), neuropraxia of the radial nerve in one (5.5%) and a peri-prosthetic fracture in one (5.5%). Excision was inadequate in four patients (22%), all of which developed local recurrence and/or metastases. There were seven deaths from the primary disease after a mean of 2.3 years (1 to 5), one of whom had an above-elbow amputation for local recurrence seven months before death. The remaining six had satisfactory elbow function at their last follow-up. The 11 living patients were evaluated using the Musculoskeletal Tumour Society and Toronto Extremity Salvage scoring systems. The mean scores achieved were 76% (67% to 87%) and 73% (59% to 79%), respectively. Overall, 17 of 18 patients had significant improvement in the degree of their pain following operation.

Custom-made endoprosthetic reconstruction of the elbow for bone tumours is a viable treatment in carefully selected patients. It maintains satisfactory function and provides good pain relief.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 272 - 279
1 Mar 2008
Charalambous CP Stanley JK

Posterolateral rotatory instability is the most common type of symptomatic chronic instability of the elbow. In this condition the forearm complex rotates externally in relation to the humerus, causing posterior subluxation or dislocation of the radial head. The lateral ligament complex, radial head and coronoid process are important constraints to posterolateral rotatory instability, and their disruption is involved in the pathogenesis of this condition. The diagnosis relies on a high index of clinical suspicion, active and passive apprehension tests, and examination under anaesthesia. Surgical treatment has given consistently successful results. Open reconstruction of the lateral ligaments with a tendon graft has been the procedure of choice, with arthroscopic techniques emerging as a potential alternative.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1107 - 1110
1 Aug 2005
Ali A Douglas H Stanley D

Sixteen patients who underwent a revision operation for nonunion of fractures of the distal humerus following previous internal fixation were reviewed at a mean follow-up of 39 months (8 to 69).

The Mayo elbow performance score was excellent in 11, good in two, fair in two and poor in one. In 15 patients union was achieved and in one with an infected nonunion a subsequent bone graft was necessary in order to obtain union.

Age, gender, a history of smoking, mechanism of the injury and the AO classification of the initial fracture did not correlate with the development of nonunion. In 12 patients (75%), the initial fixation was assessed as being suboptimal. The primary surgery was regarded as adequate in only three patients. Our findings suggest that the most important determinant of nonunion of a distal humeral fracture after surgery is the adequacy of fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 988 - 992
1 Aug 2006
Robertson A Nutton RW Keating JF