Advertisement for orthosearch.org.uk
Results 1 - 100 of 6336
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 234 - 244
1 Feb 2021
Gibb BP Hadjiargyrou M

Antibiotic resistance represents a threat to human health. It has been suggested that by 2050, antibiotic-resistant infections could cause ten million deaths each year. In orthopaedics, many patients undergoing surgery suffer from complications resulting from implant-associated infection. In these circumstances secondary surgery is usually required and chronic and/or relapsing disease may ensue. The development of effective treatments for antibiotic-resistant infections is needed. Recent evidence shows that bacteriophage (phages; viruses that infect bacteria) therapy may represent a viable and successful solution. In this review, a brief description of bone and joint infection and the nature of bacteriophages is presented, as well as a summary of our current knowledge on the use of bacteriophages in the treatment of bacterial infections. We present contemporary published in vitro and in vivo data as well as data from clinical trials, as they relate to bone and joint infections. We discuss the potential use of bacteriophage therapy in orthopaedic infections. This area of research is beginning to reveal successful results, but mostly in nonorthopaedic fields. We believe that bacteriophage therapy has potential therapeutic value for implant-associated infections in orthopaedics. Cite this article: Bone Joint J 2021;103-B(2):234–244


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 119 - 124
1 Jan 2018
Broderick C Hopkins S Mack DJF Aston W Pollock R Skinner JA Warren S

Aims. Tuberculosis (TB) infection of bones and joints accounts for 6.7% of TB cases in England, and is associated with significant morbidity and disability. Public Health England reports that patients with TB experience delays in diagnosis and treatment. Our aims were to determine the demographics, presentation and investigation of patients with a TB infection of bones and joints, to help doctors assessing potential cases and to identify avoidable delays. Patients and Methods. This was a retrospective observational study of all adults with positive TB cultures on specimens taken at a tertiary orthopaedic centre between June 2012 and May 2014. A laboratory information system search identified the patients. The demographics, clinical presentation, radiology, histopathology and key clinical dates were obtained from medical records. Results. A total of 31 adult patients were identified. Their median age was 37 years (interquartile range (IQR): 29 to 53); 21 (68%) were male; 89% were migrants. The main sites affected were joints (10, 32%), the spine (8, 26%) and long bones (6, 19%); 8 (26%) had multifocal disease. The most common presenting symptoms were pain (29/31, 94%) and swelling (26/28, 93%). ‘Typical’ symptoms of TB, such as fever, sweats and weight loss, were uncommon. Patients waited a median of seven months (IQR 3 to 13.5) between the onset of symptoms and referral to the tertiary centre and 2.3 months (IQR 1.6 to 3.4.)) between referral and starting treatment. Radiology suggested TB in 26 (84%), but in seven patients (23%) the initial biopsy specimens were not sent for mycobacterial culture, necessitating a second biopsy. Rapid Polymerase Chain Reaction-based testing for TB using Xpert MTB/RIF was performed in five patients; 4 (80%) tested positive for TB. These patients had a reduced time between the diagnostic biopsy and starting treatment than those whose samples were not tested (median eight days versus 36 days, p = 0.016). Conclusion. Patients with bone and joint TB experience delays in diagnosis and treatment, some of which are avoidable. Maintaining a high index of clinical suspicion and sending specimens for mycobacterial culture are crucial to avoid missing cases. Rapid diagnostic tests reduce delays and should be performed on patients with radiological features of TB. Cite this article: Bone Joint J 2018;100-B:119–24


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 845 - 850
1 Jun 2014
Romanò CL Logoluso N Meani E Romanò D De Vecchi E Vassena C Drago L

The treatment of chronic osteomyelitis often includes surgical debridement and filling the resultant void with antibiotic-loaded polymethylmethacrylate cement, bone grafts or bone substitutes. Recently, the use of bioactive glass to treat bone defects in infections has been reported in a limited series of patients. However, no direct comparison between this biomaterial and antibiotic-loaded bone substitute has been performed. . In this retrospective study, we compared the safety and efficacy of surgical debridement and local application of the bioactive glass S53P4 in a series of 27 patients affected by chronic osteomyelitis of the long bones (Group A) with two other series, treated respectively with an antibiotic-loaded hydroxyapatite and calcium sulphate compound (Group B; n = 27) or a mixture of tricalcium phosphate and an antibiotic-loaded demineralised bone matrix (Group C; n = 22). Systemic antibiotics were also used in all groups. After comparable periods of follow-up, the control of infection was similar in the three groups. In particular, 25 out of 27 (92.6%) patients of Group A, 24 out of 27 (88.9%) in Group B and 19 out of 22 (86.3%) in Group C showed no infection recurrence at means of 21.8 (12 to 36), 22.1 (12 to 36) and 21.5 (12 to 36) months follow-up, respectively, while Group A showed a reduced wound complication rate. Our results show that patients treated with a bioactive glass without local antibiotics achieved similar eradication of infection and less drainage than those treated with two different antibiotic-loaded calcium-based bone substitutes. Cite this article: Bone Joint J 2014; 96-B:845–50


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 665 - 672
1 May 2014
Gaston CL Nakamura T Reddy K Abudu A Carter S Jeys L Tillman R Grimer R

Bone sarcomas are rare cancers and orthopaedic surgeons come across them infrequently, sometimes unexpectedly during surgical procedures. We investigated the outcomes of patients who underwent a surgical procedure where sarcomas were found unexpectedly and were subsequently referred to our unit for treatment. We identified 95 patients (44 intra-lesional excisions, 35 fracture fixations, 16 joint replacements) with mean age of 48 years (11 to 83); 60% were males (n = 57). Local recurrence arose in 40% who underwent limb salvage surgery versus 12% who had an amputation. Despite achieving local control, overall survival was worse for patients treated with amputation rather than limb salvage (54% vs 75% five-year survival). Factors that negatively influenced survival were invasive primary surgery (fracture fixation, joint replacement), a delay of greater than two months until referral to our oncology service, and high-grade tumours. Survival in these circumstances depends mostly on factors that are determined prior to definitive treatment by a tertiary orthopaedic oncology unit. Limb salvage in this group of patients is associated with a higher rate of inadequate marginal surgery and, consequently, higher local recurrence rates than amputation, but should still be attempted whenever possible, as local control is not the primary determinant of survival. . Cite this article: Bone Joint J 2014;96-B:665–72


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1821 - 1830
1 Dec 2021
Marson BA Manning JC James M Craxford S Deshmukh SR Perry DC Ollivere BJ

Aims. The aim of this study is to develop a core set of outcome domains that should be considered and reported in all future trials of childhood limb fractures. Methods. A four-phase study was conducted to agree a set of core outcome domains. Identification of candidate outcome domains were identified through systematic review of trials, and outcome domains relevant to families were identified through semi-structured interviews with 20 families (parent-child pairing or group). Outcome domains were prioritized using an international three-round Delphi survey with 205 panellists and then condensed into a core outcome set through a consensus workshop with 30 stakeholders. Results. The systematic review and interviews identified 85 outcome domains as relevant to professionals or families. The Delphi survey prioritized 30 upper and 29 lower limb outcome domains at first round, an additional 17 upper and 18 lower limb outcomes at second round, and four additional outcomes for upper and lower limb at the third round as important domains. At the consensus workshop, the core outcome domains were agreed as: 1) pain and discomfort; 2) return to physical and recreational activities; 3) emotional and psychosocial wellbeing; 4) complications from the injury and treatment; 5) rturn to baseline activities daily living; 6) participation in learning; 7) appearance and deformity; and 8) time to union. In addition, 9a) recovery of mobility and 9b) recovery of manual dexterity was recommended as a core outcome for lower and upper limb fractures, respectively. Conclusion. This set of core outcome domains is recommended as a minimum set of outcomes to be reported in all trials. It is not an exhaustive set and further work is required to identify what outcome tools should be used to measure each of these outcomes. Adoption of this outcome set will improve the consistency of research for these children that can be combined for more meaningful meta-analyses and policy development. Cite this article: Bone Joint J 2021;103-B(12):1821–1830


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1599 - 1607
1 Dec 2020
Marson BA Craxford S Deshmukh SR Grindlay DJC Manning JC Ollivere BJ

Aims. This study evaluates the quality of patient-reported outcome measures (PROMs) reported in childhood fracture trials and recommends outcome measures to assess and report physical function, functional capacity, and quality of life using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) standards. Methods. A Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)-compliant systematic review of OVID Medline, Embase, and Cochrane CENTRAL was performed to identify all PROMs reported in trials. A search of OVID Medline, Embase, and PsycINFO was performed to identify all PROMs with validation studies in childhood fractures. Development studies were identified through hand-searching. Data extraction was undertaken by two reviewers. Study quality and risk of bias was evaluated by COSMIN guidelines and recorded on standardized checklists. Results. Searches yielded 13,672 studies, which were screened to identify 124 trials and two validation studies. Review of the 124 trials identified 16 reported PROMs, of which two had validation studies. The development papers were retrieved for all PROMs. The quality of the original development studies was adequate for Patient-Reported Outcomes Measurement Information System (PROMIS) Mobility and Upper Extremity and doubtful for the EuroQol Five Dimension Youth questionnaire (EQ-5D-Y). All other PROMs were found to have inadequate development studies. No content validity studies were identified. Reviewer-rated content validity was acceptable for six PROMs: Activity Scale for Kids (ASK), Childhood Health Assessment Questionnaire, PROMIS Upper Extremity, PROMIS Mobility, EQ-5D-Y, and Pediatric Quality of Life Inventory (PedsQL4.0). The Modified Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire was shown to have indeterminate reliability and convergence validity in one study and PROMIS Upper Extremity had insufficient convergence validity in one study. Conclusion. There is insufficient evidence to recommend strongly the use of any single PROM to assess and report physical function or quality of life following childhood fractures. There is a need to conduct validation studies for PROMs. In the absence of these studies, we cautiously recommend the use of the PROMIS or ASK-P for physical function and the PedsQL4.0 or EQ-5D-Y for quality of life. Cite this article: Bone Joint J 2020;102-B(12):1599–1607


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 548 - 554
1 Jun 2024
Ohyama Y Minoda Y Masuda S Sugama R Ohta Y Nakamura H

Aims. The aim of this study was to compare the pattern of initial fixation and changes in periprosthetic bone mineral density (BMD) between patients who underwent total hip arthroplasty (THA) using a traditional fully hydroxyapatite (HA)-coated stem (T-HA group) and those with a newly introduced fully HA-coated stem (N-HA group). Methods. The study included 36 patients with T-HA stems and 30 with N-HA stems. Dual-energy X-ray absorptiometry was used to measure the change in periprosthetic BMD, one and two years postoperatively. The 3D contact between the stem and femoral cortical bone was evaluated using a density-mapping system, and clinical assessment, including patient-reported outcome measurements, was recorded. Results. There were significantly larger contact areas in Gruen zones 3, 5, and 6 in the N-HA group than in the T-HA group. At two years postoperatively, there was a significant decrease in BMD around the proximal-medial femur (zone 6) in the N-HA group and a significant increase in the T-HA group. BMD changes in both groups correlated with BMI or preoperative lumbar BMD rather than with the extent of contact with the femoral cortical bone. Conclusion. The N-HA-coated stem showed a significantly larger contact area, indicating a distal fixation pattern, compared with the traditional fully HA-coated stem. The T-HA-coated stem showed better preservation of periprosthetic BMD, two years postoperatively. Surgeons should consider these patterns of fixation and differences in BMD when selecting fully HA-coated stems for THA, to improve the long-term outcomes. Cite this article: Bone Joint J 2024;106-B(6):548–554


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 1002 - 1008
1 Aug 2019
Al-Hourani K Stoddart M Khan U Riddick A Kelly M

Aims. Type IIIB open tibial fractures are devastating high-energy injuries. At initial debridement, the surgeon will often be faced with large bone fragments with tenuous, if any, soft-tissue attachments. Conventionally these are discarded to avoid infection. We aimed to determine if orthoplastic reconstruction using mechanically relevant devitalized bone (ORDB) was associated with an increased infection rate in type IIIB open tibial shaft fractures. Patient and Methods. This was a consecutive cohort study of 113 patients, who had sustained type IIIB fractures of the tibia following blunt trauma, over a four-year period in a level 1 trauma centre. The median age was 44.3 years (interquartile range (IQR) 28.1 to 65.9) with a median follow-up of 1.7 years (IQR 1.2 to 2.1). There were 73 male patients and 40 female patients. The primary outcome measures were deep infection rate and number of operations. The secondary outcomes were nonunion and flap failure. Results. In all, 44 patients had ORDB as part of their reconstruction, with the remaining 69 not requiring it. Eight out of 113 patients (7.1%) developed a deep infection (ORDB 1/44, non-ORDB 7/69). The median number of operations was two. A total of 16/242 complication-related reoperations were undertaken (6.6%), with 2/16 (12.5%) occurring in the ORDB group. Conclusion. In the setting of an effective orthoplastic approach to type IIIB open diaphyseal tibial fractures, using mechanically relevant debrided devitalized bone fragments in the definitive reconstruction appears to be safe. Cite this article: Bone Joint J 2019;101-B:1002–1008


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 473 - 477
1 Apr 2015
Bone MC Dold P Flohr M Preuss R Joyce TJ Aspden RM Holland J Deehan D

Concerns have been raised that deformation of acetabular shells may disrupt the assembly process of modular prostheses. In this study we aimed to examine the effect that the strength of bone has on the amount of deformation of the acetabular shell. The hypothesis was that stronger bone would result in greater deformation. A total of 17 acetabular shells were inserted into the acetabula of eight cadavers, and deformation was measured using an optical measuring system. Cores of bone from the femoral head were taken from each cadaver and compressed using a materials testing machine. The highest peak modulus and yield stress for each cadaver were used to represent the strength of the bone and compared with the values for the deformation and the surgeon’s subjective assessment of the hardness of the bone. The mean deformation of the shell was 129 µm (3 to 340). No correlation was found between deformation and either the maximum peak modulus (r² = 0.011, t = 0.426, p = 0.676) or the yield stress (r² = 0.024, t = 0.614, p = 0.549) of the bone. Although no correlation was found between the strength of the bone and deformation, the values for the deformation observed could be sufficient to disrupt the assembly process of modular acetabular components. Cite this article: Bone Joint J 2015; 97-B:473–7


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 227 - 229
1 Mar 2023
Theologis T Brady MA Hartshorn S Faust SN Offiah AC

Acute bone and joint infections in children are serious, and misdiagnosis can threaten limb and life. Most young children who present acutely with pain, limping, and/or loss of function have transient synovitis, which will resolve spontaneously within a few days. A minority will have a bone or joint infection. Clinicians are faced with a diagnostic challenge: children with transient synovitis can safely be sent home, but children with bone and joint infection require urgent treatment to avoid complications. Clinicians often respond to this challenge by using a series of rudimentary decision support tools, based on clinical, haematological, and biochemical parameters, to differentiate childhood osteoarticular infection from other diagnoses. However, these tools were developed without methodological expertise in diagnostic accuracy and do not consider the importance of imaging (ultrasound scan and MRI). There is wide variation in clinical practice with regard to the indications, choice, sequence, and timing of imaging. This variation is most likely due to the lack of evidence concerning the role of imaging in acute bone and joint infection in children. We describe the first steps of a large UK multicentre study, funded by the National Institute for Health Research, which seeks to integrate definitively the role of imaging into a decision support tool, developed with the assistance of individuals with expertise in the development of clinical prediction tools. Cite this article: Bone Joint J 2023;105-B(3):227–229


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 475 - 481
1 May 2024
Lee M Lee G Lee K

Aims. The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan. Methods. We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured. Results. Out of 37 ankles, graft incorporation was successful in 30 cases. Among the remaining seven cases, four (10.8%) exhibited cyst re-progression, so secondary bone grafting was needed. After secondary bone grafting, no further progression has been noted, resulting in an overall 91.9% success rate (34 of 37) at a mean follow-up period of 47.5 months (24 to 120). The remaining three cases (8.1%) showed implant loosening, so tibiotalocalcaneal arthrodesis was performed. Functional outcomes were also improved after bone grafting in all variables at the latest follow-up (p < 0.05). The mean incorporation rate of the grafts according to the location of the cysts was 84.8% (55.2% to 96.1%) at the medial malleolus, 65.1% (27.6% to 97.1%) at the tibia, and 81.2% (42.8% to 98.7%) at the talus. Smoking was identified as a significant predisposing factor adversely affecting graft incorporation (p = 0.001). Conclusion. Bone grafting for periprosthetic bone cysts following primary TAA is a reliable procedure with a satisfactory success rate and functional outcomes. Regular follow-up, including CT scan, is important for the detection of cyst re-progression to prevent implant loosening after bone grafting. Cite this article: Bone Joint J 2024;106-B(5):475–481


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 559 - 567
1 May 2023
Aoude A Nikomarov D Perera JR Ibe IK Griffin AM Tsoi KM Ferguson PC Wunder JS

Aims. Giant cell tumour of bone (GCTB) is a locally aggressive lesion that is difficult to treat as salvaging the joint can be associated with a high rate of local recurrence (LR). We evaluated the risk factors for tumour relapse after treatment of a GCTB of the limbs. Methods. A total of 354 consecutive patients with a GCTB underwent joint salvage by curettage and reconstruction with bone graft and/or cement or en bloc resection. Patient, tumour, and treatment factors were analyzed for their impact on LR. Patients treated with denosumab were excluded. Results. There were 53 LRs (15%) at a mean 30.5 months (5 to 116). LR was higher after curettage (18.4%) than after resection (4.6%; p = 0.008). Neither pathological fracture (p = 0.240), Campanacci grade (p = 0.734), soft-tissue extension (p = 0.297), or tumour size (p = 0.872) affected the risk of recurrence. Joint salvage was possible in 74% of patients overall (262/354), and 98% after curettage alone (262/267). Of 49 patients with LR after curettage, 44 (90%) underwent repeated curettage and joint salvage. For patients treated by curettage, only age less than 30 years (p = 0.042) and location in the distal radius (p = 0.043) predicted higher LR. The rate of LR did not differ whether cement or bone graft was used (p = 0.753), but may have been reduced by the use of hydrogen peroxide (p = 0.069). Complications occurred in 15.3% of cases (54/354) and did not differ by treatment. Conclusion. Most patients with a GCTB can undergo successful joint salvage by aggressive curettage, even in the presence of a soft-tissue mass, pathological fracture, or a large lesion, with an 18.4% risk of local recurrence. However, 90% of local relapses after curettage can be treated by repeat joint salvage. Maximizing joint salvage is important to optimize long-term function since most patients with a GCTB are young adults. Younger patients and those with distal radius tumours treated with joint-sparing procedures have a higher rate of local relapse and may require more aggressive treatment and closer follow-up. Cite this article: Bone Joint J 2023;105-B(5):559–567


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 11 - 16
1 Jan 2023
San-Julián M Gómez-Álvarez J Idoate MÁ Aquerreta JD Vázquez-García B Lamo-Espinosa JM

Paediatric bone sarcomas are a dual challenge for orthopaedic surgeons in terms of tumour resection and reconstruction, as it is important to minimize functional and growth problems without compromising survival rates. Cañadell’s technique consists of a Type I epiphysiolysis performed using continuous distraction by an external fixator prior to resection. It was designed to achieve a safe margin due to the ability of the physeal cartilage to be a barrier to tumour spread in some situations, avoiding the need for articular reconstruction, and preserving the growth capacity most of the times. Despite initial doubts raised in the scientific community, this technique is now widely used in many countries for the treatment of metaphyseal paediatric bone sarcomas. This annotation highlights the importance of Cañadell’s work and reviews the experience of applying it to bone sarcoma patients over the last 40 years. Cite this article: Bone Joint J 2023;105-B(1):11–16


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 121 - 128
1 Jan 2015
Kang S Han I Hong SH Cho HS Kim W Kim H

Cancellous allograft bone chips are commonly used in the reconstruction of defects in bone after removal of benign tumours. We investigated the MRI features of grafted bone chips and their change over time, and compared them with those with recurrent tumour. We retrospectively reviewed 66 post-operative MRIs from 34 patients who had undergone curettage and grafting with cancellous bone chips to fill the defect after excision of a tumour. All grafts showed consistent features at least six months after grafting: homogeneous intermediate or low signal intensities with or without scattered hyperintense foci (speckled hyperintensities) on T1 images; high signal intensities with scattered hypointense foci (speckled hypointensities) on T2 images, and peripheral rim enhancement with or without central heterogeneous enhancements on enhanced images. Incorporation of the graft occurred from the periphery to the centre, and was completed within three years. Recurrent lesions consistently showed the same signal intensities as those of pre-operative MRIs of the primary lesions. There were four misdiagnoses, three of which were chondroid tumours. We identified typical MRI features and clarified the incorporation process of grafted cancellous allograft bone chips. The most important characteristics of recurrent tumours were that they showed the same signal intensities as the primary tumours. It might sometimes be difficult to differentiate grafted cancellous allograft bone chips from a recurrent chondroid tumour. Cite this article: Bone Joint J 2015;97-B:121–8


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims. The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Methods. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis. Results. Among the 203 enrolled patients, infection recurred in 27 patients (13.3%) after bone grafting. The union rate was 75.9% (154 patients) after second-stage surgery without additional procedures, and final union was achieved in 173 patients (85.2%) after second-stage surgery with or without additional procedures. The mean healing time was 9.3 months (3 to 37). Multivariate logistic regression analysis of 203 patients showed that the number (≥ two) of debridements (first stage) was an independent risk factor for infection recurrence and nonunion. Larger defect sizes were associated with higher odds of nonunion. After excluding 27 patients with infection recurrence, multivariate analysis of the remaining 176 patients suggested that intramedullary nail plus plate internal fixation, smoking, and an allograft-to-autograft ratio exceeding 1:3 adversely affected healing time. Conclusion. The IMT is an effective method to achieve infection eradication and union in the management of infected segmental bone defects. Our study identified several risk factors associated with unfavourable outcomes. Some of these factors are modifiable, and the risk of adverse outcomes can be reduced by adopting targeted interventions or strategies. Surgeons can fully inform patients with non-modifiable risk factors preoperatively, and may even use other methods for bone defect reconstruction. Cite this article: Bone Joint J 2024;106-B(6):613–622


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims. To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time. Methods. We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated. Results. The mean time between the implantation and the second CT scan was two years (1 to 5). The mean age of the patients during CTAC implantation was 75 years (60 to 92). The mean scaffold-bone contact area increased from 16% (SD 12.6) to 28% (SD 11.9). The mean scaffold-bone distance decreased from a mean of 6.5 mm (SD 2.0) to 5.5 mm (SD 1.6). None of the CTACs were revised or radiologically loose. Conclusion. There was a statistically significant increase of scaffold-bone contact area over time, but the total contact area of the scaffold in relation to the acetabular bone remained relatively low. As all implants remained well fixed, the question remains to what extend the scaffold contributes to the observed stability, in relation to the screws. A future design implication might be an elimination of the bulky scaffold component. This design modification would reduce production costs and may optimize the primary fit of the implant. Cite this article: Bone Joint J 2024;106-B(4):359–364


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1206 - 1215
1 Nov 2023
Ladegaard TH Sørensen MS Petersen MM

Aims. We first sought to compare survival for patients treated surgically for solitary and multiple metastases in the appendicular skeleton, and second, to explore the role of complete and incomplete resection (R0 and R1/R2) in patients with a solitary bony metastasis in the appendicular skeleton. Methods. We conducted a retrospective study on a population-based cohort of all adult patients treated surgically for bony metastases of the appendicular skeleton between January 2014 and December 2019. We excluded patients in whom the status of bone metastases and resection margin was unknown. Patients were followed until the end of the study or to their death. We had no loss to follow-up. We used Kaplan-Meier analysis (with log-rank test) to evaluate patient survival. We identified 506 operations in 459 patients. A total of 120 operations (in 116 patients) were for solitary metastases and 386 (in 345 patients) for multiple metastases. Of the 120 operations, 70 (in 69 patients) had no/an unknown status of visceral metastases (solitary group) and 50 (in 49 patients) had visceral metastases. In the solitary group, 45 operations (in 44 patients) were R0 (resections for cure or complete remission) and 25 (in 25 patients) were R1/R2 (resections leaving microscopic or macroscopic tumour, respectively). The most common types of cancer in the solitary group were kidney (n = 27), lung (n = 25), and breast (n = 20). Results. The one-year patient survival was 47% (95% confidence interval (CI) 38 to 57) for the solitary bony metastases and 34% (95% CI 29 to 39) for multiple bone metastases (p < 0.001). The one-year patient survival was 64% (95% CI 52 to 75) for solitary bony metastases without/with unknown visceral metastases and 23% (95% CI 11 to 36) for solitary bony metastases with visceral metastases (p < 0.001). The one-year patient survival was 75% (95% CI 62 to 89) for a solitary bony metastasis after R0 surgery and 42% (95% CI 22 to 61) for a solitary bony metastasis with R1/R2 surgery (p < 0.001). Conclusion. Our study suggests that the surgical treatment of patients with a solitary bony metastasis to the appendicular skeleton results in better survival than for patients with multiple bony metastases. Furthermore, aggressive treatment of a solitary bony metastasis with R0 surgery may improve patient survival. Cite this article: Bone Joint J 2023;105-B(11):1206–1215


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 898 - 906
1 Sep 2024
Kayani B Wazir MUK Mancino F Plastow R Haddad FS

Aims. The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system. Methods. This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed. Results. The BOne trauma and Soft-Tissue Injury classification system in total Hip arthroplasty (BOSTI Hip) grades osseous acetabular trauma and periarticular muscle damage during THA. The classification system has an interclass correlation coefficient of 0.90 (95% CI 0.86 to 0.93) for interobserver agreement and 0.89 (95% CI 0.84 to 0.93) for intraobserver agreement. RO THA was associated with improved BOSTI Hip scores (p = 0.002) and more pristine osseous surfaces in the anterior superior (p = 0.001) and posterior superior (p < 0.001) acetabular quadrants compared with CO THA. There were no differences between the groups in relation to injury to the gluteus medius (p = 0.084), obturator internus (p = 0.241), piriformis (p = 0.081), superior gamellus (p = 0.116), inferior gamellus (p = 0.132), quadratus femoris (p = 0.208), and vastus lateralis (p = 0.135), but overall combined muscle injury was reduced in RO THA compared with CO THA (p = 0.023). Discussion. The proposed BOSTI Hip classification provides a reproducible grading system for stratifying iatrogenic bone trauma and soft-tissue injury during THA. RO THA was associated with improved BOSTI Hip scores, more pristine osseous acetabular surfaces, and reduced combined periarticular muscle injury compared with CO THA. Further research is required to understand if these intraoperative findings translate to differences in clinical outcomes between the treatment groups. Cite this article: Bone Joint J 2024;106-B(9):898–906


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 86 - 92
1 Jan 2024
Scholte CHJ Dorleijn DMJ Krijvenaar DT van de Sande MAJ van Langevelde K

Aims. Due to its indolent clinical behaviour, the treatment paradigm of atypical cartilaginous tumours (ACTs) in the long bones is slowly shifting from intralesional resection (curettage) and local adjuvants, towards active surveillance through wait-and-scan follow-up. In this retrospective cohort study performed in a tertiary referral centre, we studied the natural behaviour of ACT lesions by active surveillance with MRI. Clinical symptoms were not considered in the surveillance programme. Methods. The aim of this study was to see whether active surveillance is safe regarding malignant degeneration and local progression. In total, 117 patients were evaluated with MRI assessing growth, cortical destruction, endosteal scalloping, periosteal reaction, relation to the cortex, and perilesional bone marrow oedema. Patients received up to six follow-up scans. Results. At the time of the first follow-up MRI, 8% of the lesions showed growth (n = 9), 86% remained stable (101), and 6% decreased in size (n = 7). During the third follow-up, with a mean follow-up time of 60 months (SD 23), 24 patients were scanned, of whom 13% had lesions that had grown and 13% lesions that had decreased in size. After 96 months (SD 37), at the sixth follow-up MRI, 100% of the lesions remained stable. None of the lesions showed malignant progression and although some lesions grew in size (mean 1 mm (SD 0.8)), no malignant progression occurred. Conclusion. We conclude that active surveillance with MRI is safe for ACTs in the long bones in the short- and mid-term follow-up. Cite this article: Bone Joint J 2024;106-B(1):86–92


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 508 - 514
1 May 2024
Maximen J Jeantet R Violas P

Aims. The aim of this study is to evaluate the surgical treatment with the best healing rate for patients with proximal femoral unicameral bone cysts (UBCs) after initial surgery, and to determine which procedure has the lowest adverse event burden during follow-up. Methods. This multicentre retrospective study was conducted in 20 tertiary paediatric hospitals in France, Belgium, and Switzerland, and included patients aged < 16 years admitted for UBC treatment in the proximal femur from January 1995 to December 2017. UBCs were divided into seven groups based on the index treatment, which included elastic stable intramedullary nail (ESIN) insertion with or without percutaneous injection or grafting, percutaneous injection alone, curettage and grafting alone, and insertion of other orthopaedic hardware with or without curettage. Results. A total of 201 patients were included in the study. The mean age at diagnosis was 8.7 years (SD 3.9); 77% (n = 156) were male. The mean follow-up was 9.4 years (SD 3.9). ESIN insertion without complementary procedure had a 67% UBC healing rate after the first operation (vs 30% with percutaneous injection alone (p = 0.027), 43% with curettage and grafting (p = 0.064), and 21% with insertion of other hardware combined with curettage (p < 0.001) or 36% alone (p = 0.014)). ESIN insertion with percutaneous injection presented a 79% healing rate, higher than percutaneous injection alone (p = 0.017), curettage and grafting (p = 0.028), and insertion of other hardware combined with curettage (p < 0.001) or alone (p = 0.014). Patients who underwent ESIN insertion with curettage had a 53% healing rate, higher than insertion of other hardware combined with curettage (p = 0.009). The overall rate of postoperative complications was 25% and did not differ between groups (p = 0.228). A total of 32 limb length discrepancies were identified. Conclusion. ESIN insertion, either alone or combined with percutaneous injection or curettage and grafting, may offer higher healing rates than other operative procedures. Limb length discrepancy remains a major concern, and might be partly explained by the cyst’s location and the consequence of surgery. Therefore, providing information about this risk is crucial. Cite this article: Bone Joint J 2024;106-B(5):508–514


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims. To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia. Methods. We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure. Results. A total of 64 patients (76 hips) were included in this study. The median follow-up period was ten years (interquartile range (IQR) five to 14). The median mHHS improved from 67 (IQR 56 to 80) preoperatively to 96 (IQR 85 to 97) at the latest follow-up (p < 0.001). The radiological parameters improved postoperatively (p < 0.001), with the resulting parameters falling within the normal range in 42% to 95% of hips. The survival rate was 95% at ten years and 80% at 15 years. Preoperative Tönnis grade 2 was an independent risk factor for TOA failure. Conclusion. Our findings suggest that TOA with structural bone allografting is a viable surgical option for correcting severely dysplastic acetabulum in adolescents and young adults without advanced osteoarthritis, with favourable mid-term outcomes. Cite this article: Bone Joint J 2023;105-B(7):743–750


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 82 - 88
1 May 2024
Villa JM Rajschmir K Hosseinzadeh S Manrique-Succar J Grieco P Higuera-Rueda CA Riesgo AM

Aims. Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation. Methods. A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707). Results. Out of the 33 cases analyzed, six (18.2%) constructs required revision, with four revisions due to uncontrolled infection, one for dislocation, and one for aseptic loosening. Among the 27 non-revised constructs, only one showed wider radiolucencies compared to immediate postoperative radiographs, indicating potential loosening. Patients who underwent revision (n = 6) were significantly younger and had a higher BMI compared to those with non-revised constructs (p = 0.016 and p = 0.026, respectively). Sex, race, ethnicity, American Society of Anesthesiologists grade, infection status (patients with postoperative PJI diagnosis (septic) vs patients without such diagnosis (aseptic)), and mean follow-up did not significantly differ between revised and non-revised groups. Conclusion. The HiRISC technique may serve as a feasible short-term (about one to two years) alternative in patients with large acetabular defects, particularly in cases of PJI. Longer follow-up is necessary to establish the long-term survival of this technique. Cite this article: Bone Joint J 2024;106-B(5 Supple B):82–88


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 808 - 814
1 Jul 2023
Gundavda MK Lazarides AL Burke ZDC Focaccia M Griffin AM Tsoi KM Ferguson PC Wunder JS

Aims. The preoperative grading of chondrosarcomas of bone that accurately predicts surgical management is difficult for surgeons, radiologists, and pathologists. There are often discrepancies in grade between the initial biopsy and the final histology. Recent advances in the use of imaging methods have shown promise in the ability to predict the final grade. The most important clinical distinction is between grade 1 chondrosarcomas, which are amenable to curettage, and resection-grade chondrosarcomas (grade 2 and 3) which require en bloc resection. The aim of this study was to evaluate the use of a Radiological Aggressiveness Score (RAS) to predict the grade of primary chondrosarcomas in long bones and thus to guide management. Methods. A total of 113 patients with a primary chondrosarcoma of a long bone presenting between January 2001 and December 2021 were identified on retrospective review of a single oncology centre’s prospectively collected database. The nine-parameter RAS included variables from radiographs and MRI scans. The best cut-off of parameters to predict the final grade of chondrosarcoma after resection was determined using a receiver operating characteristic curve (ROC), and this was correlated with the biopsy grade. Results. A RAS of ≥ four parameters was 97.9% sensitive and 90.5% specific in predicting resection-grade chondrosarcoma based on a ROC cut-off derived using the Youden index. Cronbach’s α of 0.897 was derived as the interclass correlation for scoring the lesions by four blinded reviewers who were surgeons. Concordance between resection-grade lesions predicted from the RAS and ROC cut-off with the final grade after resection was 96.46%. Concordance between the biopsy grade and the final grade was 63.8%. However, when the patients were analyzed based on surgical management, the initial biopsy was able to differentiate low-grade from resection-grade chondrosarcomas in 82.9% of biopsies. Conclusion. These findings suggest that the RAS is an accurate method for guiding the surgical management of patients with these tumours, particularly when the initial biopsy results are discordant with the clinical presentation. Cite this article: Bone Joint J 2023;105-B(7):808–814


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 203 - 211
1 Feb 2024
Park JH Won J Kim H Kim Y Kim S Han I

Aims. This study aimed to compare the performance of survival prediction models for bone metastases of the extremities (BM-E) with pathological fractures in an Asian cohort, and investigate patient characteristics associated with survival. Methods. This retrospective cohort study included 469 patients, who underwent surgery for BM-E between January 2009 and March 2022 at a tertiary hospital in South Korea. Postoperative survival was calculated using the PATHFx3.0, SPRING13, OPTIModel, SORG, and IOR models. Model performance was assessed with area under the curve (AUC), calibration curve, Brier score, and decision curve analysis. Cox regression analyses were performed to evaluate the factors contributing to survival. Results. The SORG model demonstrated the highest discriminatory accuracy with AUC (0.80 (95% confidence interval (CI) 0.76 to 0.85)) at 12 months. In calibration analysis, the PATHfx3.0 and OPTIModel models underestimated survival, while the SPRING13 and IOR models overestimated survival. The SORG model exhibited excellent calibration with intercepts of 0.10 (95% CI -0.13 to 0.33) at 12 months. The SORG model also had lower Brier scores than the null score at three and 12 months, indicating good overall performance. Decision curve analysis showed that all five survival prediction models provided greater net benefit than the default strategy of operating on either all or no patients. Rapid growth cancer and low serum albumin levels were associated with three-, six-, and 12-month survival. Conclusion. State-of-art survival prediction models for BM-E (PATHFx3.0, SPRING13, OPTIModel, SORG, and IOR models) are useful clinical tools for orthopaedic surgeons in the decision-making process for the treatment in Asian patients, with SORG models offering the best predictive performance. Rapid growth cancer and serum albumin level are independent, statistically significant factors contributing to survival following surgery of BM-E. Further refinement of survival prediction models will bring about informed and patient-specific treatment of BM-E. Cite this article: Bone Joint J 2024;106-B(2):203–211


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 551 - 558
1 May 2023
Wang H Ji T Qu H Yan T Li D Yang R Tang X Guo W

Aims. The aim of this study was to determine the rate of indocyanine green (ICG) staining of bone and soft-tissue tumours, as well as the stability and accuracy of ICG fluorescence imaging in detecting tumour residuals during surgery for bone and soft-tissue tumours. Methods. ICG fluorescence imaging was performed during surgery in 34 patients with bone and soft-tissue tumours. ICG was administered intravenously at a dose of 2 mg/kg over a period of 60 minutes on the day prior to surgery. The tumour stain rate and signal-to-background ratio of each tumour were post hoc analyzed. After tumour resection, the tumour bed was scanned to locate sites with fluorescence residuals, which were subsequently inspected and biopsied. Results. The overall tumour stain rate was 88% (30/34 patients), and specific stain rates included 90% for osteosarcomas and 92% for giant cell tumours. For malignant tumours, the overall stain rate was 94%, while it was 82% for benign tumours. The ICG tumour stain was not influenced by different pathologies, such as malignant versus benign pathology, the reception (or lack thereof) of neoadjuvant chemotherapies, the length of time between drug administration and surgery, the number of doses of denosumab for patients with giant cell tumours, or the tumour response to neoadjuvant chemotherapy. The overall accuracy rate of successfully predicting tumour residuals using fluorescence was 49% (23/47 pieces of tissue). The accuracy rate after en bloc resection was significantly lower than that after piecemeal resection (16% vs 71%; p < 0.001). Conclusion. A high percentage of bone and soft-tissue tumours can be stained by ICG and the tumour staining with ICG was stable. This approach can be used in both benign and malignant tumours, regardless of whether neoadjuvant chemotherapy is adopted. The technique is also useful to detect tumour residuals in the wound, especially in patients undergoing piecemeal resection. Cite this article: Bone Joint J 2023;105-B(5):551–558


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 34 - 44
1 Jan 2022
Beckers L Dandois F Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims. Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs. Methods. In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m. 2. (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research. Results. Significant reduction of tracer activity from the preoperative situation was found in femoral and anteromedial tibial VOIs adjacent to the UKA components. Temporarily increased osteoblastic bone activity was observed in VOIs comprising the UKA keel structure at one year postoperatively compared to the preoperative activity. Persistent higher tracer uptake was found in the posterior tibial cortex at final follow-up. Multivariate analysis showed no statistical difference in osteoblastic bone activity underneath cemented or cementless components. Conclusion. Well-functioning medial mobile-bearing UKAs showed distinct changes in patterns of normalized bone tracer activity in the different VOIs adjacent to the prosthetic components, regardless of their type of fixation. Compared to the preoperative situation, persistent high bone activity was found underneath the keel and the posterior tibial cortex at final follow-up, with significant reduced activity only being identified in femoral and anteromedial tibial VOIs. Cite this article: Bone Joint J 2022;104-B(1):34–44


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1233 - 1234
1 Dec 2023
Haddad FS


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 81 - 86
1 Jun 2021
Mahfouz MR Abdel Fatah EE Johnson JM Komistek RD

Aims. The objective of this study is to assess the use of ultrasound (US) as a radiation-free imaging modality to reconstruct 3D anatomy of the knee for use in preoperative templating in knee arthroplasty. Methods. Using an US system, which is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allows 3D tracking of the probe, femur, and tibia. The raw US radiofrequency (RF) signals are acquired and, using real-time signal processing, bone boundaries are extracted. Bone boundaries and the tracking information are fused in a 3D point cloud for the femur and tibia. Using a statistical shaping model, the patient-specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was conducted for 17 cadavers by comparing the 3D US models with those created using CT. US scans from 15 users were compared in order to examine the effect of operator variability on the output. Results. The results revealed that the US bone models were accurate compared with the CT models (root mean squared error (RM)S: femur, 1.07 mm (SD 0.15); tibia, 1.02 mm (SD 0.13). Additionally, femoral landmarking proved to be accurate (transepicondylar axis: 1.07° (SD 0.65°); posterior condylar axis: 0.73° (SD 0.41°); distal condylar axis: 0.96° (SD 0.89°); medial anteroposterior (AP): 1.22 mm (SD 0.69); lateral AP: 1.21 mm (SD 1.02)). Tibial landmarking errors were slightly higher (posterior slope axis: 1.92° (SD 1.31°); and tubercle axis: 1.91° (SD 1.24°)). For implant sizing, 90% of the femora and 60% of the tibiae were sized correctly, while the remainder were only one size different from the required implant size. No difference was observed between moderate and skilled users. Conclusion. The 3D US bone models were proven to be closely matched compared with CT and suitable for preoperative planning. The 3D US is radiation-free and offers numerous clinical opportunities for bone visualization rapidly during clinic visits, to enable preoperative planning with implant sizing. There is potential to extend its application to 3D dynamic ligament balancing, and intraoperative registration for use with robots and navigation systems. Cite this article: Bone Joint J 2021;103-B(6 Supple A):81–86


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 297 - 301
1 Feb 2022
Jamshidi K Bagherifard A Mohaghegh MR Mirzaei A

Aims. Giant cell tumours (GCTs) of the proximal femur are rare, and there is no consensus about the best method of filling the defect left by curettage. In this study, we compared the outcome of using a fibular strut allograft and bone cement to reconstruct the bone defect after extended curettage of a GCT of the proximal femur. Methods. In a retrospective study, we reviewed 26 patients with a GCT of the proximal femur in whom the bone defect had been filled with either a fibular strut allograft (n = 12) or bone cement (n = 14). Their demographic details and oncological and nononcological complications were retrieved from their medical records. Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) score. Results. Mean follow-up was 116 months (SD 59.2; 48 to 240) for the fibular strut allograft group and 113 months (SD 43.7; 60 to 192) for the bone cement group (p = 0.391). The rate of recurrence was not significantly different between the two groups (25% vs 21.4%). The rate of nononcological complications was 16.7% in the strut allograft group and 42.8% in the bone cement group. Degenerative joint disease was the most frequent nononcological complication in the cement group. The mean MSTS score of the patients was 92.4% (SD 11.5%; 73.3% to 100.0%) in the fibular strut allograft group and 74.2% (SD 10.5%; 66.7% to 96.7%) in the bone cement group (p < 0.001). Conclusion. Given the similar rate of recurrence and a lower rate of nononcological complications, fibular strut grafting could be recommended as a method of reconstructing the bone defect left by curettage of a GCT of the proximal femur. Cite this article: Bone Joint J 2022;104-B(2):297–301


Aims. Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. Methods. A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. Results. One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous fixation of the stem. No patient had radiolucency around the interlocking screws and no screw broke. One patient had non-progressive subsidence and two had a dislocation. The mean Harris Hip Score increased from of 57.8 points (SD 7.9) three months postoperatively to 76.1 points (SD 10.7) 24 months postoperatively. Conclusion. The 2° tapered, fluted revision femoral component with distal cone-in-cone-fixation, combined with additional distal interlocking in patients with bony deficiency at the isthmus, led to reproducibly good results in patients with a Vancouver B3 fracture and Paprosky type IIIA, IIIB, and IV defects with regard to union of the fracture, subsidence or loosening of the stem, and clinical outcomes. Cite this article: Bone Joint J 2024;106-B(4):344–351


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1731 - 1735
1 Nov 2021
Iobst CA Frost MW Rölfing JD Rahbek O Bafor A Duncan M Kold S

Aims. Limb-lengthening nails have largely replaced external fixation in limb-lengthening and reconstructive surgery. However, the adverse events and high prevalence of radiological changes recently noted with the STRYDE lengthening nail have raised concerns about the use of internal lengthening nails. The aim of this study was to compare the prevalence of radiological bone abnormalities between STRYDE, PRECICE, and FITBONE nails prior to nail removal. Methods. This was a retrospective case series from three centres. Patients were included if they had either of the three limb-lengthening nails (STYDE, PRECICE, or FITBONE) removed. Standard orthogonal radiographs immediately prior to nail removal were examined for bone abnormalities at the junction of the telescoping nail parts. Results. In total, 306 patients (168 male, 138 female) had 366 limb-lengthening nails removed. The mean time from nail insertion to radiological evaluation was 434 days (36 to 3,015). Overall, 77% of STRYDE nails (20/26) had bone abnormalities at the interface compared with only 2% of FITBONE (4/242) and 1% of PRECICE nails (1/98; p < 0.001). Focal osteolysis in conjunction with periosteal reaction at the telescoping interface was only observed in STRYDE nails. Conclusion. Bone abnormalities at the interface of telescoping nail parts were seen in the majority of STRYDE nails, but only very rarely with FITBONE or PRECICE nails. We conclude that the low prevalence of radiological changes at the junctional interface of 242 FITBONE and 98 PRECICE nails at the time of nail removal does not warrant clinical concerns. Cite this article: Bone Joint J 2021;103-B(11):1731–1735


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 230 - 230
1 Mar 2023
Theologis T Brady MA Hartshorn S Faust SN Offiah AC


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1723 - 1734
1 Dec 2020
Fung B Hoit G Schemitsch E Godbout C Nauth A

Aims. The purpose of this study was to: review the efficacy of the induced membrane technique (IMT), also known as the Masquelet technique; and investigate the relationship between patient factors and technique variations on the outcomes of the IMT. Methods. A systematic search was performed in CINAHL, The Cochrane Library, Embase, Ovid MEDLINE, and PubMed. We included articles from 1 January 1980 to 30 September 2019. Studies with a minimum sample size of five cases, where the IMT was performed primarily in adult patients (≥ 18 years old), in a long bone were included. Multivariate regression models were performed on patient-level data to determine variables associated with nonunion, postoperative infection, and the need for additional procedures. Results. A total of 48 studies were included, with 1,386 cases treated with the IMT. Patients had a mean age of 40.7 years (4 to 88), and the mean defect size was 5.9 cm (0.5 to 26). In total, 82.3% of cases achieved union after the index second stage procedure. The mean time to union was 6.6 months (1.4 to 58.7) after the second stage. Our multivariate analysis of 450 individual patients showed that the odds of developing a nonunion were significantly increased in those with preoperative infection. Patients with tibial defects, and those with larger defects, were at significantly higher odds of developing a postoperative infection. Our analysis also demonstrated a trend towards the inclusion of antibiotics in the cement spacer having a protective effect against the need for additional procedures. Conclusion. The IMT is an effective management strategy for complex segmental bone defects. Standardized reporting of individual patient data or larger prospective trials is required to determine the optimal implementation of this technique. This is the most comprehensive review of the IMT, and the first to compile individual patient data and use regression models to determine predictors of outcomes. Cite this article: Bone Joint J 2020;102-B(12):1723–1734


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 268 - 272
1 Feb 2020
Diarbakerli E Savvides P Wihlborg A Abbott A Bergström I Gerdhem P

Aims. Idiopathic scoliosis is the most common spinal deformity in adolescents and children. The aetiology of the disease remains unknown. Previous studies have shown a lower bone mineral density in individuals with idiopathic scoliosis, which may contribute to the causation. The aim of the present study was to compare bone health in adolescents with idiopathic scoliosis with controls. Methods. We included 78 adolescents with idiopathic scoliosis (57 female patients) at a mean age of 13.7 years (8.5 to 19.6) and 52 age- and sex-matched healthy controls (39 female patients) at a mean age of 13.8 years (9.1 to 17.6). Mean skeletal age, estimated according to the Tanner-Whitehouse 3 system (TW3), was 13.4 years (7.4 to 17.8) for those with idiopathic scoliosis, and 13.1 years (7.4 to 16.5) for the controls. Mean Cobb angle for those with idiopathic scoliosis was 29° (SD 11°). All individuals were scanned with dual energy x-ray absorptiometry (DXA) and peripheral quantitative CT (pQCT) of the left radius and tibia to assess bone density. Statistical analyses were performed with independent-samples t-test, the Mann-Whitney U test, and the chi-squared test. Results. Compared with controls, adolescents with idiopathic scoliosis had mean lower DXA values in the left femoral neck (0.94 g/cm. 2. (SD 0.14) vs 1.00 g/cm. 2. (SD 0.15)), left total hip (0.94 g/cm. 2. (SD 0.14) vs 1.01 g/cm. 2. (SD 0.17)), L1 to L4 (0.99 g/cm. 2. (SD 0.15) vs 1.06 g/cm. 2. (SD 0.17)) and distal radius (0.35 g/cm. 2. (SD 0.07) vs 0.39 g/cm. 2. (SD 0.08; all p ≤ 0.024), but not in the mid-radius (0.72 g/cm. 2. vs 0.74 g/cm. 2. ; p = 0.198, independent t-test) and total body less head (1,559 g (SD 380) vs 1,649 g (SD 492; p = 0.0.247, independent t-test). Compared with controls, adolescents with idiopathic scoliosis had lower trabecular volume bone mineral density (BMD) on pQCT in the distal radius (184.7 mg/cm. 3. (SD 40.0) vs 201.7 mg/cm. 3. (SD 46.8); p = 0.029), but not in other parts of the radius or the tibia (p ≥ 0.062, Mann-Whitney U test). Conclusion. In the present study, idiopathic scoliosis patients seemed to have lower BMD at central skeletal sites and less evident differences at peripheral skeletal sites when compared with controls. Cite this article: Bone Joint J 2020;102-B(2):268–272


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1237 - 1243
1 Sep 2017
Emori M Kaya M Irifune H Takahashi N Shimizu J Mizushima E Murahashi Y Yamashita T

Aims. The aims of this study were to analyse the long-term outcome of vascularised fibular graft (VFG) reconstruction after tumour resection and to evaluate the usefulness of the method. . Patients and Methods. We retrospectively reviewed 49 patients who had undergone resection of a sarcoma and reconstruction using a VFG between 1988 and 2015. Their mean follow-up was 98 months (5 to 317). Reconstruction was with an osteochondral graft (n = 13), intercalary graft (n = 12), inlay graft (n = 4), or resection arthrodesis (n = 20). We analysed the oncological and functional outcome, and the rate of bony union and complications. Results. Five- and ten-year overall survival rates were 89% and 86%, respectively. Local recurrence occurred in two patients. Eight patients developed pulmonary metastases. Bone union was achieved in 44 patients (90%). Fracture occurred in six patients (12%), infection in three (6%), and nonunion in five (10%). The mean Musculoskeletal Tumor Society (MSTS) scores were as follows: osteochondral graft 70%; intercalary graft 73%; inlay graft 89%; and resection arthrodesis 83%. Conclusion. Although associated with a relatively high rate of complications, each reconstruction method is useful, with a high rate of successful limb salvage and a good long-term functional outcome. Cite this article: Bone Joint J 2017;99-B:1237–43


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 7 - 15
1 Jan 2021
Farhan-Alanie MM Burnand HG Whitehouse MR

Aims. This study aimed to compare the effect of antibiotic-loaded bone cement (ALBC) versus plain bone cement (PBC) on revision rates for periprosthetic joint infection (PJI) and all-cause revisions following primary elective total hip arthroplasty (THA) and total knee arthroplasty (TKA). Methods. MEDLINE, Embase, Web of Science, and Cochrane databases were systematically searched for studies comparing ALBC versus PBC, reporting on revision rates for PJI or all-cause revision following primary elective THA or TKA. A random-effects meta-analysis was performed. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO ID CRD42018107691). Results. Nine studies and one registry report were identified, enabling the inclusion of 371,977 THA and 671,246 TKA. Pooled analysis for THA demonstrated ALBC was protective against revision for PJI compared with PBC (relative risk (RR) 0.66, 95% confidence interval (CI) 0.56 to 0.77; p < 0.001), however, no differences were seen for all-cause revision rate (RR 0.62, 95% CI 0.35 to 1.09; p = 0.100). For TKA, there were no significant differences in revision rates for PJI or all causes between ALBC and PBC (RR 0.92, 95% CI 0.59 to 1.45; p = 0.730, and RR 0.73, 95% CI 0.53 to 1.02; p = 0.060, respectively). Conclusion. ALBC demonstrated a protective effect against revision for PJI compared with PBC in THA with no difference in all-cause revisions. No differences in revision rates for PJI and all-cause revision between ALBC and PBC for TKA were observed. Cite this article: Bone Joint J 2021;103-B(1):7–15


Aims. The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail). Methods. Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of radiolucent lines, and additional patient-reported outcome measures (PROMs). Results. There were no statistically significant differences between the groups regarding PROMs (median OHS (CFP 45 (interquartile range (IQR) 35 to 48); Corail 45 (IQR 40 to 48); p = 0.568). RSA showed stable stems in both groups, with little or no further subsidence between two and five years. Resorption of the femoral neck was evident in nine patients in the CFP group and in none of the 15 Corail stems with a collar that could be studied. Dual X-ray absorbiometry showed a significantly higher loss of BMD in the proximal Gruen zones in the CFP group (mean changes in BMD: Gruen zone 1, CFP -9.5 (95% confidence interval (CI) -14.8 to -4.2), Corail 1.0 (95% CI 3.4 to 5.4); Gruen zone 7, CFP -23.0 (95% CI -29.4 to -16.6), Corail -7.2 (95% CI -15.9 to 1.4). Two CFP stems were revised before two years’ follow-up due to loosening, and one Corail stem was revised after two years due to chronic infection. Conclusion. The CFP stem has a similar clinical outcome and subsidence pattern when compared with the Corail stem. More pronounced proximal stress-shielding was seen with the CFP stem, suggesting diaphyseal fixation, and questioning its femoral neck-sparing properties in the long term. Cite this article: Bone Joint J 2022;104-B(5):581–588


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims. To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes. Methods. A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups. Results. There were ten and 25 defects in the femur and tibia, respectively. Median LEFS improved significantly from 8 (IQR 1.5 to 19.3) preoperatively to 63.5 (IQR 57 to 73.3) at final follow-up (p < 0.001). Bone healing was achieved in all limbs, and median time from the second stage to bone healing was six months (IQR 5 to 10). Median time to bone healing, preoperative LEFS, or postoperative LEFS did not differ significantly between the defect size groups or among the treatment groups. Conclusion. IMT using β-TCP provided satisfactory clinical and radiological outcomes for segmental bone defects in the lower limbs; surgical outcomes were not influenced by bone defect size or operated part. Cite this article: Bone Joint J 2021;103-B(3):456–461


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1349 - 1353
3 Oct 2020
Park CH Song K Kim JR Lee S

Aims. The hypothesis of this study was that bone peg fixation in the treatment of osteochondral lesions of the talus would show satisfactory clinical and radiological results, without complications. Methods. Between September 2014 and July 2017, 25 patients with symptomatic osteochondritis of the talus and an osteochondral fragment, who were treated using bone peg fixation, were analyzed retrospectively. All were available for complete follow-up at a mean 22 of months (12 to 35). There were 15 males and ten females with a mean age of 19.6 years (11 to 34). The clinical results were evaluated using a visual analogue scale (VAS) and the American Orthopaedic Foot and Ankle Society (AOFAS) score preoperatively and at the final follow-up. The radiological results were evaluated using classification described by Hepple et al based on the MRI findings, the location of the lesion, the size of the osteochondral fragment, and the postoperative healing of the lesion. Results. The mean VAS and AOFAS score improved significantly from 6.3 (4 to 8) and 70.6 (44 to 78) preoperatively to 1.6 (0 to 5) and 91.1 (77 to 100) at the final follow-up, respectively (p < 0.001). The classification on MRI was stage 2a in nine patients, stage 3 in 14, and stage 4 in two. The lesion was located on the posteromedial aspect of the dome of the talus in 19 patients, the anterolateral aspect in five, and the centrolateral aspect in one. The mean size of the fragment was 11.2 mm (5 to 20) horizontally, 10.4 mm (7 to 18) vertically, and 5.2 mm (3 to 10) deep, respectively. The postoperative healing state was good in 19 patients and fair in six. Conclusion. Bone peg fixation for osteochondral lesions of the talus showed satisfactory clinical and radiographic results, without complications. This technique could be a good form of treatment for patients with this condition who have an osteochondral fragment. Cite this article: Bone Joint J 2020;102-B(10):1349–1353


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 997 - 1002
1 Aug 2020
Leong JW Cook MJ O’Neill TW Board TN

Aims. The aim of this study was to investigate whether the use of antibiotic-loaded bone cement influenced the risk of revision surgery after primary total hip arthroplasty (THA) for osteoarthritis. Methods. The study involved data collected by the National Joint Registry (NJR) for England and Wales, Northern Ireland and the Isle of Man between 1 September 2005 and 31 August 2017. Cox proportional hazards were used to investigate the association between use of antibiotic-loaded bone cement and the risk of revision due to prosthetic joint infection (PJI), with adjustments made for the year of the initial procedure, age at the time of surgery, sex, American Society of Anesthesiologists (ASA) grade, head size, and body mass index (BMI). We looked also at the association between use of antibiotic-loaded bone cement and the risk of revision due to aseptic loosening or osteolysis. Results. The cohort included 418,857 THAs of whom 397,896 had received antibiotic-loaded bone cement and 20,961 plain cement. After adjusting for putative confounding factors, the risk of revision for PJI was lower in those in whom antibiotic-loaded bone cement was used (hazard ration (HR) 0.79; 95% confidence interval (CI) 0.64 to 0.98). There was also a protective effect on the risk of revision due to aseptic loosening or osteolysis, in the period of > 4.1 years after primary THA, HR 0.57, 95% CI 0.45, 0.72. Conclusion. Within the limits of registry analysis, this study showed an association between the use of antibiotic-loaded bone cement and lower rates of revision due to PJI. The findings support the continued use of antibiotic-loaded bone cement in cemented THA. Cite this article: Bone Joint J 2020;102-B(8):997–1002


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 184 - 191
1 Jan 2021
Perrin DL Visgauss JD Wilson DA Griffin AM Abdul Razak AR Ferguson PC Wunder JS

Aims. Local recurrence remains a challenging and common problem following curettage and joint-sparing surgery for giant cell tumour of bone (GCTB). We previously reported a 15% local recurrence rate at a median follow-up of 30 months in 20 patients with high-risk GCTB treated with neoadjuvant Denosumab. The aim of this study was to determine if this initial favourable outcome following the use of Denosumab was maintained with longer follow-up. Methods. Patients with GCTB of the limb considered high-risk for unsuccessful joint salvage, due to minimal periarticular and subchondral bone, large soft tissue mass, or pathological fracture, were treated with Denosumab followed by extended intralesional curettage with the goal of preserving the joint surface. Patients were followed for local recurrence, metastasis, and secondary sarcoma. Results. A total of 25 patients with a mean age of 33.8 years (18 to 67) with high-risk GCTB received median six cycles of Denosumab before surgery. Tumours occurred most commonly around the knee (17/25, 68%). The median follow-up was 57 months (interquartile range (IQR) 13 to 88). The joint was salvaged in 23 patients (92%). Two required knee arthroplasty due to intra-articular fracture and arthritis. Local recurrence developed in 11 patients (44%) at a mean of 32.5 months (3 to 75) following surgery, of whom four underwent repeat curettage and joint salvage. One patient developed secondary osteosarcoma and another benign GCT lung metastases. Conclusion. The use of Denosumab for joint salvage was associated with a higher than expected rate of local recurrence at 44%. Neoadjuvant Denosumab for joint-sparing procedures should be considered with caution in light of these results. Cite this article: Bone Joint J 2021;103-B(1):184–191


1. The antigenicity of cancellous bone has been investigated in ninety-seven rabbits. 2. The immune responses of lymph nodes draining fresh homografts of cancellous bone (Burwell and Gowland 1961b) has been used as a histological indicator of the antigenicity of components of fresh homologous cancellous bone and also of the antigenicity of homologous bone subjected to a variety of physical or chemical treatments. 3. The principal antigenic component of a fresh homograft of iliac cancellous bone is the nucleated cells of the red marrow. 4. Homologous marrow-free cancellous bone does not usually produce cytological evidence of an immune response in the lymph node draining the graft, unless new homograft bone formation occurs. 5. The treatment of marrow-containing cancellous bone by boiling, freezing at - 20 degrees Centigrade, freeze-drying, irradiation or by merthiolate solution impairs the transplantation antigenicity of the tissue as a homograft. 6. The immersion of cancellous bone in a glycerol-serum-Ringer solution which is then slowly cooled to - 79 degrees Centigrade, stored for one week and then rapidly thawed, allows considerable preservation of the antigenicity of the red marrow. 7. Knowledge concerning the antigenicity of fresh and treated homologous bone is discussed. 8. Evidence is presented to show that the large and medium lymphoid cell response of lymph nodes draining homografts is due principally to the T-antigens, rather than H-antigens, of the grafts. 9. The changes which occur in the first regional lymph nodes draining tissue homografts may provide another test system to assess the transplantation antigenicity of foreign tissues or extracts of foreign tissues other than bone


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1380 - 1385
2 Aug 2021
Kim Y Ryu J Kim JK Al-Dhafer BAA Shin YH

Aims. The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function. Methods. We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis. Results. According to Eaton-Glickel classification, 11, 17, 17, and eight hands were stage 0 to I, II, III, and IV, respectively. The interobserver reliability for determining the stage of arthritis was moderate for radiographs (k = 0.41) and substantial for CT scans (k = 0.67). In a binary categorical analysis using SUVmax, pain (p < 0.001) and PRWHE scores (p = 0.004) were significantly higher in hands with higher SUVmax. Using multivariate linear regression to estimate the pain VAS, only SUVmax (B 0.172 (95% confidence interval (CI) 0.065 to 0.279; p = 0.002) showed a significant association. Estimating the variation of PRWHE scores using the same model, only SUVmax (B 1.378 (95% CI, 0.082 to 2.674); p = 0.038) showed a significant association. Conclusion. The CT scans of SPECT/CT provided better interobserver reliability than routine radiographs for evaluating the severity of arthritis. A higher SUVmax in SPECT/CT was associated with more pain and functional disabilities of basal joint arthritis of the thumb. This approach could be used to complement radiographs for the evaluation of patients with this condition. Cite this article: Bone Joint J 2021;103-B(8):1380–1385


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 186 - 190
1 Feb 2020
Puri A Hegde P Gulia A Parikh M

Aims. The aim of this study was to analyze the complications and outcomes of treatment in a series of previously untreated patients with a primary aneurysmal bone cyst (ABC) who had been treated by percutaneous sclerosant therapy using polidocanol. Methods. Between January 2010 and December 2016, 56 patients were treated primarily with serial intralesional sclerosant injections. Their mean age was 20 years (1 to 54). The sites involved were clavicle (n = 3), humeri (n = 11), radius (n = 1), ulna (n = 3), hand (n = 2), pelvis (n = 12), femur (n = 7), tibia (n = 13), fibula (n = 3), and foot (n = 1). After histopathological confirmation of the diagnosis, 3% polidocanol (hydroxypolyaethoxydodecan) was injected into the lesion under image intensifier guidance. Patients were evaluated clinically and radiologically every six to eight weeks. In the absence of clinical and/or radiological response, a repeat sclerosant injection was given after eight to 12 weeks and repeated at similar intervals if necessary. Results. There were no complications of treatment. One patient was lost to follow-up. Overall, 46/55 (84%) of lesions healed after one or more injections of polidocanol: 24/55 (44%) patients healed with a single injection, and 43/55 (78%) within two injections. Of these 46, four (9%) patients developed local recurrence, two of whom healed with a repeat sclerosant injection. Thus, 44/55 (80%) patients of primary ABC healed with sclerotherapy. The mean follow-up was 62 months (20 to 111). The local recurrence free survival (LRFS) with percutaneous sclerosant therapy with polidocanol was 100%, 98% (95% confidence interval (CI) 85 to 100) and 93% (95% CI 78 to 98) at two, three, and five years, respectively. Conclusion. Percutaneous sclerotherapy using polidocanol is a safe, effective, minimally invasive and inexpensive method of treating a primary ABC of the limbs or pelvis. Cite this article: Bone Joint J 2020;102-B(2):186–190


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 665 - 671
1 Apr 2021
Osawa Y Seki T Okura T Takegami Y Ishiguro N Hasegawa Y

Aims. We compared the clinical outcomes of curved intertrochanteric varus osteotomy (CVO) with bone impaction grafting (BIG) with CVO alone for the treatment of osteonecrosis of the femoral head (ONFH). Methods. This retrospective comparative study included 81 patients with ONFH; 37 patients (40 hips) underwent CVO with BIG (BIG group) and 44 patients (47 hips) underwent CVO alone (CVO group). Patients in the BIG group were followed-up for a mean of 12.2 years (10.0 to 16.5). Patients in the CVO group were followed-up for a mean of 14.5 years (10.0 to 21.0). Assessment parameters included the Harris Hip Score (HHS), Oxford Hip Score (OHS), Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire (JHEQ), complication rates, and survival rates, with conversion to total hip arthroplasty (THA) and radiological failure as the endpoints. Results. There were no significant differences in preoperative and postoperative HHS or postoperative OHS and JHEQ between the BIG group and the CVO group. Complication rates were comparable between groups. Ten-year survival rates with conversion to THA and radiological failure as the endpoints were not significantly different between groups. Successful CVO (postoperative coverage ratio of more than one-third) exhibited better ten-year survival rates with radiological failure as the endpoint in the BIG group (91.4%) than in the CVO group (77.7%), but this difference was not significant (p = 0.079). Conclusion. Long-term outcomes of CVO with BIG were favourable when proper patient selection and accurate surgery are performed. However, this study did not show improvements in treatment results with the concomitant use of BIG. Cite this article: Bone Joint J 2021;103-B(4):665–671


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1200 - 1209
14 Sep 2020
Miyamura S Lans J He JJ Murase T Jupiter JB Chen NC

Aims. We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. Methods. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves. Results. In the nonunion group, both the distal (100.2%) and proximal (126.6%) fragments had a significantly higher bone density compared to the union (distal: 85.7%; proximal: 108.3%) or control groups (distal: 91.6%; proximal: 109.1%) using the 3D bone density measurement, which were statistically significant for all comparisons. 2D measurements were highly correlated to 3D bone density measurements (Spearman’s correlation coefficient (R) = 0.85 to 0.95). Using 2D measurements, ROC curve analysis revealed the optimal cutoffs of 90.8% and 116.3% for distal and proximal fragments. This led to a sensitivity of 1.00 if either cutoff is met and a specificity of 0.82 when both cutoffs are met. Conclusion. Using 3D modelling software, nonunions were found to exhibit bone density increases in both the distal and proximal fragments in CTs performed between four to 18 weeks after fracture during the course of treatment. 2D bone density measurements using standard CT scans correlate well with 3D models. In patients with scaphoid fractures, CT bone density measurements may be useful in predicting the likelihood of nonunion. Cite this article: Bone Joint J 2020;102-B(9):1200–1209


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 123 - 130
1 Jan 2021
Lapner P Pollock JW Laneuville O Uhthoff HK Zhang T Sheikh A McIlquham K Trudel G

Aims. Despite recent advances in arthroscopic rotator cuff repair, re-tear rates remain high. New methods to improve healing rates following rotator cuff repair must be sought. Our primary objective was to determine if adjunctive bone marrow stimulation with channelling five to seven days prior to arthroscopic cuff repair would lead to higher Western Ontario Rotator Cuff (WORC) scores at 24 months postoperatively compared with no channelling. Methods. A prospective, randomized controlled trial was conducted in patients undergoing arthroscopic rotator cuff repair. Patients were randomized to receive either a percutaneous bone channelling of the rotator cuff footprint or a sham procedure under ultrasound guidance five to seven days prior to index surgery. Outcome measures included the WORC, American Shoulder and Elbow Surgeons (ASES), and Constant scores, strength, ultrasound-determined healing rates, and adverse events. Results. Overall, 94 patients were randomized to either bone channelling or a sham procedure. Statistically significant improvements in all clinical outcome scores occurred in both groups from preoperative to all timepoints (p < 0.001). Intention-to-treat analysis revealed no statistical differences in WORC scores between the two interventions at 24 months postoperatively (p = 0.690). No differences were observed in secondary outcomes at any timepoint and healing rates did not differ between groups (p = 0.186). Conclusion. Preoperative bone channelling one week prior to arthroscopic rotator cuff repair was not associated with significant improvements in WORC, ASES, Constant scores, strength, or ultrasound-determined healing rates. Cite this article: Bone Joint J 2021;103-B(1):123–130


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 838 - 844
1 Jul 2020
Chen L Hong G Hong Z Lin T Chen Z Zhang Q He W

Aims. The aim of this study was to report the medium-term outcomes of impaction bone allograft and fibular grafting for osteonecrosis of the femoral head (ONFH) and to define the optimal indications. Methods. A total of 67 patients (77 hips) with ONFH were enrolled in a single centre retrospective review. Success of the procedure was assessed using the Harris Hip Score (HHS) and rate of revision to total hip arthroplasty (THA). Risk factors were studied, including age, aetiology, duration of hip pain, as well as two classification systems (Association Research Circulation Osseous (ARCO) and Japanese Investigation Committee (JIC) systems). Results. After a mean follow-up period of 8.61 years (SD 1.45), 81.3% (52/64) of enrolled cases had a good or excellent HHS at latest follow-up (declining to 76.0% (38/50) for those with more than eight years of follow-up). Overall survival was 92.1% at eight years’ follow-up (95% CI 83.2% to 96.4%). A total of 12 hips (19.0%) failed (reoperation or HHS < 70 points) at final follow-up. Rate of success was adversely affected by increasing age, duration of pain, and more severe disease as measured using the ARCO and JIC classifications, but not by aetiology of the ONFH. Conclusion. We report favourable medium-term results of this procedure. Best outcomes can be expected in patients matching the following indications: younger than 40 years; less 12-month hip pain before surgery; femoral head collapse being less than 2 mm; and integrated lateral wall of femoral head. Cite this article: Bone Joint J 2020;102-B(7):838–844


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 3 | Pages 503 - 519
1 Aug 1962
Little K Kelly M Courts A

1. The appearance of decalcified bone matrix in the electron microscope is described. 2. In the matrix two types of collagen fibril have been distinguished. Differences observed are in solubility, x-ray diffraction pattern and appearance. In infant bone the form which appears as fine fibrils predominates. In adult bone the form which appears as tubular fibrils of larger diameter predominates. 3. In bones from elderly subjects the chemical reaction employed to convert collagen into eucollagen sometimes hydrolyses fatty acid esters, and lines due to the free fatty acid are found on the x-ray diffraction patterns of the insoluble residue after citrate extraction. 4. In ancient bones and fossils the stable tubular form of collagen survives, but not the fine fibrils. 5. When decalcified, the matrix in osteoporotic bones loses its architecture and fibrillar form. Under conditions in which only a small fraction is dissolved from normal bone most of the collagen in osteoporotic bone disperses in citric acid. The insoluble residue then gives a modified x-ray diffraction pattern. 6. Evidence has been produced to suggest that the immediate cause of many forms of osteoporosis is some local factor affecting the osteocytes, rather than a general chemical effect


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 625 - 627
1 Aug 1988
Aspenberg P Lohmander L Thorngren K

Extraskeletal bone formation can be induced in rodents by implantation of demineralised bone matrix and such implantation has been used to treat bone defects in man, but it is uncertain if induction or merely conduction occurs. We studied bone induction in primates by excising segments of the fibulae of adult squirrel monkeys, defatting and demineralising them before reimplanting them into the quadriceps of the same animal. As a control experiment, rat matrix was prepared in exactly the same way and implanted in rats. After six weeks the implants were harvested and either ashed and analysed for calcium content or prepared for histology. In the rats, the calcium content indicated that about 20% of the original matrix had been replaced by new bone. In the monkeys the calcium content was about the same as that in normal body fluid and no bone was seen in histological sections. This result casts doubt on the use of demineralised human bone matrix as a bone inductor, although it may function by other mechanisms


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 407 - 412
1 Apr 2002
Chang CH Stanton RP Glutting J

In 79 consecutive patients with unicameral bone cysts we compared the results of aspiration and injection of bone marrow with those of aspiration and injection of steroid. All were treated by the same protocol. The only difference was the substance injected into the cysts. The mean radiological follow-up to detect activity in the cyst was 44 months (12 to 108). Of the 79 patients, 14 received a total of 27 injections of bone marrow and 65 a total of 99 injections of steroid. Repeated injections were required in 57% of patients after bone marrow had been used and in 49% after steroid. No complications were noted in either group. In this series no advantage could be shown for the use of autogenous injection of bone marrow compared with injection of steroid in the management of unicameral bone cysts


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1402 - 1407
1 Nov 2019
Cehic M Lerner RG Achten J Griffin XL Prieto-Alhambra D Costa ML

Aims. Bone health assessment and the prescription of medication for secondary fracture prevention have become an integral part of the acute management of patients with hip fracture. However, there is little evidence regarding compliance with prescription guidelines and subsequent adherence to medication in this patient group. Patients and Methods. The World Hip Trauma Evaluation (WHiTE) is a multicentre, prospective cohort of hip fracture patients in NHS hospitals in England and Wales. Patients aged 60 years and older who received operative treatment for a hip fracture were eligible for inclusion in WHiTE. The prescription of bone protection medications was recorded from participants’ discharge summaries, and participant-reported use of bone protection medications was recorded at 120 days following surgery. Results. Of 5456 recruited patients with baseline data, 2853 patients (52%) were prescribed bone protection medication at discharge, of which oral bisphosphonates were the most common, 4109 patients (75%) were prescribed vitamin D or calcium, and 606 patients (11%) were not prescribed anything. Of those prescribed a bone protection medication, only 932 patients (33%) reported still taking their medication 120 days later. Conclusion. These data provide a reference for current prescription and adherence rates. Adherence with oral medication remains poor in patients with hip fracture. Cite this article: Bone Joint J 2019;101-B:1402–1407


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 107 - 110
1 Jan 1993
Miyamoto S Takaoka K Ono K

We investigated bone induction by bone morphogenetic protein in primates, comparing it with that seen in rodents. Twelve Millipore diffusion chambers containing 5 mg of semipurified bone morphogenetic protein were implanted into the dorsal muscles of 12 young, adult crab-eating monkeys (Macaca fascicularis) and were retrieved six weeks later. In six of nine unbroken chambers, new bone with haematopoietic marrow had been induced on the host-side surface of the filter. The incidence of trans-filter bone induction in the monkeys was almost equal to that observed in mice, and the new bone yield was approximately half as much as in mice. Our results show that bone morphogenetic protein can induce new bone formation in primates within six weeks, and support the hope that it will be useful as a substitute for bone graft in man


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 1 | Pages 110 - 140
1 Feb 1964
Burwell RG

1. Previous immunological studies have shown that homografts of fresh marrow-free iliac bone are only weakly, if at all, antigenic. 2. In view of this finding an attempt was made to produce a foreign bone graft capable of forming new bone as readily as an iliac autograft by the following method. Living cells of high osteogenic potential and of autologous type were introduced into the graft by combining homologous fresh marrow-free iliac bone with the animal's own red marrow to form a fresh composite homograft-autograft of cancellous bone. 3. Such fresh composite homograft-autografts were inserted into a muscular site in Wistar rats and removed for microscopical examination at intervals of one to seven days and at two, six and twelve weeks after transplantation. 4. It is found that bone and marrow together as a fresh composite homograft-autograft form considerably more new bone than do either of the components of the graft transplanted separately. Homografts of fresh marrow-free iliac bone form, in general, a small amount of early phase and late phase new bone. Autografts of red marrow transplanted alone to a muscular site formed new bone in thirteen to thirty experiments (43 per cent). 5. The stimulus to osteogenesis, and the cellular source of osteoblasts, in marrow autografts is discussed in the light of present knowledge. The concept is suggested that after its transplantation there develops in marrow an inductive system leading to osteoblastic differentiation and bone formation. It is proposed that the necrosis of a portion of a marrow graft liberates osteogenic substances which are taken up by primitive wandering cells derived from littoral cells lining the vascular sinusoids of the surviving portions of the marrow which are induced, thereby, to differentiate as osteoblasts. 6. The cellular source of osteoblasts in a fresh composite homograft-autograft of cancellous bone is discussed. It is deduced that the new bone is derived mainly from the contained marrow of the graft, by mechanisms similar to those leading to osteoblastic differentiation in transplanted autografts of marrow. 7. The stimulus to the greater formation of new bone by fresh composite autograft-homografts than by autografts of marrow transplanted alone is discussed. Two explanations are suggested: 1) a more extensive necrosis of marrow in a composite homograft-autograft than in marrow transplanted alone; and 2) an inductive effect of bone upon marrow. 8. The new bone formed by autografts of fresh marrow-containing iliac bone, it is concluded, is derived not only from osteoblasts on the surfaces of the grafted bone but also from primitive wandering cells derived from littoral cells lining the vascular sinusoids of the surviving portions of its marrow. 9. Mechanisms which may play a role in the histogenesis of woven bone are discussed. 10. The significance of the relation of bone and marrow is considered briefly in the light of knowledge concerning the venous patterns of bone and marrow


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 121 - 126
1 Jan 2007
Jensen TB Overgaard S Lind M Rahbek O Bünger C Søballe K

Impacted bone allograft is often used in revision joint replacement. Hydroxyapatite granules have been suggested as a substitute or to enhance morcellised bone allograft. We hypothesised that adding osteogenic protein-1 to a composite of bone allograft and non-resorbable hydroxyapatite granules (ProOsteon) would improve the incorporation of bone and implant fixation. We also compared the response to using ProOsteon alone against bone allograft used in isolation. We implanted two non-weight-bearing hydroxyapatite-coated implants into each proximal humerus of six dogs, with each implant surrounded by a concentric 3 mm gap. These gaps were randomly allocated to four different procedures in each dog: 1) bone allograft used on its own; 2) ProOsteon used on its own; 3) allograft and ProOsteon used together; or 4) allograft and ProOsteon with the addition of osteogenic protein-1. After three weeks osteogenic protein-1 increased bone formation and the energy absorption of implants grafted with allograft and ProOsteon. A composite of allograft, ProOsteon and osteogenic protein-1 was comparable, but not superior to, allograft used on its own. ProOsteon alone cannot be recommended as a substitute for allograft around non-cemented implants, but should be used to extend the volume of the graft, preferably with the addition of a growth factor


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1144 - 1150
1 Sep 2019
Tsuda Y Fujiwara T Sree D Stevenson JD Evans S Abudu A

Aims. The aim of this study was to report the results of custom-made endoprostheses with extracortical plates plus or minus a short, intramedullary stem aimed at preserving the physis after resection of bone sarcomas in children. Patients and Methods. Between 2007 and 2017, 18 children aged less than 16 years old who underwent resection of bone sarcomas, leaving ≤ 5 cm of bone from the physis, and reconstruction with a custom-made endoprosthesis were reviewed. Median follow-up was 67 months (interquartile range 45 to 91). The tumours were located in the femur in 11 patients, proximal humerus in six, and proximal tibia in one. Results. The five-year overall survival rate was 78%. No patient developed local recurrence. The five-year implant survival rate was 79%. In all, 11 patients (61%) developed a complication. Seven patients (39%) required further surgery to treat the complications. Implant failures occurred in three patients (17%) including one patient with aseptic loosening and two patients with implant or periprosthetic fracture. The preserved physis continued to grow at mean 3.3 cm (0 to 14). The mean Musculoskeletal Society score was 88% (67% to 97%). Conclusion. Custom-made endoprostheses that aim to preserve the physis are a safe and effective option for preserving physeal growth, limb length, and joint function with an acceptable rate of complications. Cite this article: Bone Joint J 2019;101-B:1144–1150


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 635 - 642
1 Aug 1986
Nilsson O Urist M Dawson E Schmalzried T Finerman G

In dogs, resection of a length of the ulna equal to twice the diameter of the mid-shaft leaves a defect which consistently fails to unite. In response to an implant of 100 mg of bovine bone morphogenetic protein (BMP), the defect becomes filled by callus consisting of fibrocartilage, cartilage and woven bone within four weeks. The cartilage is resorbed and replaced by new bone in four to eight weeks. Woven bone is then resorbed, colonised by bone marrow cells and remodelled into lamellar bone. Union of the defect is produced by 12 weeks. Control defects filled with autogeneic cortical bone chips unite after the same period. In regeneration induced by bone morphogenetic protein (BMP) and in repair enhanced by bone graft, union depends upon the proliferation of cells within and around the bone ends. Our working hypothesis is that BMP induces the differentiation of perivascular connective tissue cells into chondroblasts and osteoprogenitor cells and thereby augments the process of bone regeneration from the cells already present in the endosteum and periosteum


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 1 | Pages 102 - 109
1 Feb 1968
Dooley BJ

Cancellous inlay bone grafting for delayed union or non-union of the scaphoid bone gives good results in most cases (Table IV). The operation is easy, does not require radiological control and does not damage the dorsal arterial plexus. The indications for the operation are twofold: firstly for patients complaining of disabling symptoms in the wrist joint with an established pseudarthrosis of the scaphoid bone, with neither arthritic changes nor severe avascularity of the proximal fragment; and, secondly, for delayed union in recent fractures despite adequate immobilisation. Union may still occur if conservative treatment is continued further, but because this may take up to eighteen months (during which time most patients would be unable to work), operation is a reasonable alternative. In this series two scaphoid fractures united after operation with some collapse of the proximal fragment. This probably resulted from removal of too much bone (preliminary to inlaying the graft) from an already small fragment with a poor blood supply. The operation can be performed even in the presence of a small proximal fragment and gave a satisfactory result in two out of three such cases


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 189 - 196
1 May 1977
Nade S Burwell R

This paper examines the fate of decalcified allografts (homografts) of iliac cancellous bone impregnated with autologous red marrow and implanted intermuscularly into the anterior abdominal wall of rabbits. In contrast to the findings of Urist and other workers that cortical bone decalcified with hydrochloric acid (HCl) and then freeze-dried is inductive to new bone formation in various heterotopic sites, evidence is presented that iliac bone decalcified by HCl and grafted alone to a muscular site is itself very weakly inductive to bone formation. However, when combined with autologous bone marrow the HCl-decalcified bone provides a better substrate for bone formation by marrow cells than does either undecalcified iliac bone, or iliac bone decalcified with ethylene-diamine-tetra-acetic acid. The freezing or freeze-drying of decalcified bone does not affect new bone formation when implanted alone or with autologous marrow. The differences between the cortical and cancellous bone as inductive substrates for osteogenesis are discussed and the interrelationship of bone and marrow in combined bone grafts are re-evaluated


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 64 - 71
1 Jan 2020
Tsuda Y Fujiwara T Stevenson JD Parry MC Tillman R Abudu A

Aims. The purpose of this study was to report the long-term results of extendable endoprostheses of the humerus in children after the resection of a bone sarcoma. Methods. A total of 35 consecutive patients treated with extendable endoprosthetic replacement of the humerus in children were included. There were 17 boys and 18 girls in the series with a median age at the time of initial surgery of nine years (interquartile range (IQR) 7 to 11). Results. The median follow-up time was 10.6 years (IQR 3.9 to 20.4). The overall implant survival at ten years was 75%. Complications occurred in 13 patients (37%). Subluxation at the proximal humerus occurred in 19 patients (54%) but only six (17%) were symptomatic. Subluxation was seen more commonly in children under the age of nine years (86%) than in those aged nine years or more (33%) (p = 0.002). Implant failure occurred in nine patients (26%): the most common cause was aseptic loosening (four patients, 11%). Lengthening of the implant was carried out in 23 patients (66%). At final follow up, three patients had a limb that was shortened by 5 cm or more. The mean Musculoskeletal Tumor Society (MSTS) functional score was 79% (73% to 90%). Conclusion. Extendable endoprosthetic replacement is a reliable method of reconstructing humerus after excision of a bone sarcoma. Children who are less than nine years old have a high risk of subluxation. Cite this article: Bone Joint J 2020;102-B(1):64–71


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 62 - 67
1 Jun 2019
Tanzer M Chuang PJ Ngo CG Song L TenHuisen KS

Aims. The purpose of this study was to evaluate the biological fixation of a 3D printed porous implant, with and without different hydroxyapatite (HA) coatings, in a canine model. Materials and Methods. A canine transcortical model was used to evaluate the characteristics of bone ingrowth of Ti6Al4V cylindrical implants fabricated using laser rapid manufacturing (LRM). At four and 12 weeks post-implantation, we performed histological analysis and mechanical push-out testing on three groups of implants: a HA-free control (LRM), LRM with precipitated HA (LRM-PA), and LRM with plasma-sprayed HA (LRM-PSHA). Results. Substantial bone ingrowth was observed in all LRM implants, with and without HA, at both time periods. Bone ingrowth increased from 42% to 52% at four weeks, to 60% to 65% at 12 weeks. Mechanical tests indicated a minimum shear fixation strength of 20 MPa to 24 MPa at four weeks, and 34 MPa to 40 MPa at 12 weeks. There was no significant difference in the amount of bone ingrowth or in the shear strength between the three implant types at either time period. Conclusion. At four and 12 weeks, the 3D printed porous implants exhibited consistent bone ingrowth and high mechanical shear strength. Based on the results of this study, we confirmed the suitability of this novel new additive manufacturing porous material for biological fixation by bone ingrowth. Cite this article: Bone Joint J 2019;101-B(6 Supple B):62–67


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 638 - 645
1 May 2020
Sternheim A Traub F Trabelsi N Dadia S Gortzak Y Snir N Gorfine M Yosibash Z

Aims. Accurate estimations of the risk of fracture due to metastatic bone disease in the femur is essential in order to avoid both under-treatment and over-treatment of patients with an impending pathological fracture. The purpose of the current retrospective in vivo study was to use CT-based finite element analyses (CTFEA) to identify a clear quantitative differentiating factor between patients who are at imminent risk of fracturing their femur and those who are not, and to identify the exact location of maximal weakness where the fracture is most likely to occur. Methods. Data were collected on 82 patients with femoral metastatic bone disease, 41 of whom did not undergo prophylactic fixation. A total of 15 had a pathological fracture within six months following the CT scan, and 26 were fracture-free during the five months following the scan. The Mirels score and strain fold ratio (SFR) based on CTFEA was computed for all patients. A SFR value of 1.48 was used as the threshold for a pathological fracture. The sensitivity, specificity, positive, and negative predicted values for Mirels score and SFR predictions were computed for nine patients who fractured and 24 who did not, as well as a comparison of areas under the receiver operating characteristic curves (AUC of the ROC curves). Results. The sensitivity of SFR was 100% compared with 88% for the Mirels score, and the specificity of SFR was 67% compared with 38% for the Mirels score. The AUC was 0.905 for SFR compared with 0.578 for the Mirels score (p = 0.008). Conclusion. All the patients who sustained a pathological fracture of the femur had an SFR of > 1.48. CTFEA was far better at predicting the risk of fracture and its location accurately compared with the Mirels score. CTFEA is quick and automated and can be incorporated into the protocol of CT scanners. Cite this article: Bone Joint J 2020;102-B(5):638–645


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 253 - 257
1 Feb 2007
Seel EH Davies EM

We performed a biomechanical study to compare the augmentation of isolated fractured vertebral bodies using two different bone tamps. Compression fractures were created in 21 vertebral bodies harvested from red deer after determining their initial strength and stiffness, which was then assessed after standardised bipedicular vertebral augmentation using a balloon or an expandable polymer bone tamp. The median strength and stiffness of the balloon bone tamp group was 6.71 kN (. sd. 2.71) and 1.885 kN/mm (. sd. 0.340), respectively, versus 7.36 kN (. sd. 3.43) and 1.882 kN/mm (. sd. 0.868) in the polymer bone tamp group. The strength and stiffness tended to be greater in the polymer bone tamp group than in the balloon bone tamp group, but this difference was not statistically significant (strength p > 0.8, and stiffness p = 0.4)


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 2 | Pages 386 - 401
1 May 1963
Burwell RG

1. Experiments to examine the antigenicity of homologous bone tissues in rats are reported. The tissues studied included fresh marrow-free cortical bone blocks and chips, fresh, boiled, frozen and freeze-dried marrow-containing iliac bone, fresh iliac bone devoid of marrow, and fresh red marrow. 2. The various tissues were transplanted from hooded to Wistar rats. Three weeks later a skin graft from each donor was transplanted to its respective host to detect the presence of transplantation immunity, which was indicated by the early rejection of the skin graft. 3. Homografts of fresh cortical bone evoked transplantation immunity indicating that it contained transplantation antigens which were also in the skin. 4. Homografts of fresh marrow-containing iliac bone also evoked transplantation immunity, which was shown to be caused by the red marrow. 5. Fresh iliac homografts devoid of marrow did not elicit transplantation immunity. This suggests that iliac bone tissue may not contain transplantation antigens or that the small amount of iliac bone inserted was insufficient. 6. Microscopy of the grafts, removed after three weeks, showed that the inflammatory infiltrations around the bone homografts and autografts were not very different, but that the amount of new bone formed was different. The autografts produced a lot of new bone, the homografts only a little. 7. It is suggested that the immune response evoked in the host by the foreign graft impairs the formation of new bone by fresh homografts of cortical blocks, cortical chips and marrow-containing iliac bone. 8. The impairment of new bone formation by homografts of marrow-free iliac bone is discussed. Such bone grafts fail to evoke detectable transplantation immunity. Why these grafts do not form more new homologous bone than the other homografts studied, is not clear. 9. Homografts of boiled and frozen iliac bone do not evoke any detectable change in the sensitivity of the host to donor tissue. 10. Homografts of freeze-dried marrow-containing iliac bone elicit a slight but significant prolongation of the survival of skin homografts. The implication, in terms of modern immunological theory, is that in such grafts certain tissue antigens still persist


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 3 | Pages 597 - 608
1 Aug 1963
Burwell RG Gowland G Dexter F

1. The antigenicity of homologous cortical and cancellous bone has been investigated in eighty-four rabbits. 2. The primary immune responses which occur in lymph nodes draining homografts of fresh tissues (Burwell and Gowland 1961, 1962) have been used as a histological indicator of the antigenicity of fresh homologous cortical bone freed from soft tissues. 3. The secondary immune responses which occur in lymph nodes draining homografts of fresh marrow-containing iliac bone (Burwell 1962a, b) have been used also as a histological indicator of the antigenicity of homografts of 1) fresh cortical bone freed from soft tissues, 2) fresh marrow-free iliac bone, and 3) mairow-containing iliac bone treated by boiling, freezi ng, freeze-drying and merthiolate solution. 4. It is found that whereas fresh homologous cortical bone fails usually to produce cytological evidence of a primary response in the regional lymph nodes, fresh homologous cortical bone chips inserted into the drainage areas of lymph nodes sensitised previously to donor ..tissue evoke constantly cytological evidence of a secondary response. 5. Fresh homologous marrow-free iliac bone inserted into the drainage areas of lymph nodes sensitised previously to donor tissue does not produce detectable evidence of a secondary response. 6. Homografts of boiled marrow-containing iliac bone do not elicit a secondary response in lymph nodes previously sensitised to donor tissue. 7. Previous work has shown that homografts of frozen (–20 degrees Centigrade) marrow-containing iliac bone do not evoke a primary response in lymph nodes draining such grafts. In the present work it is shown that similar frozen homografts inserted into the drainage areas of lymph nodes previously sensitised to donor tissue evoked a secondary response in three of six lymph nodes. 8. Homografts offreeze-dried marrow-containing iliac bone fail usually to evoke a secondary response in lymph nodes sensitised to donor tissue. 9. Homografts of marrow-containing iliac bone treated by immersion in merthiolate solution before being inserted into the drainage areas of lymph nodes previously sensitised to tissue from the donor elicited a secondary response in three of five lymph nodes. 10. Knowledge concerning the antigenicity offresh and treated homologous bone is discussed in the light of recent work


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 138 - 141
1 Jan 2000
Skripitz R Andreassen TT Aspenberg P

Intermittent treatment with parathyroid hormone (PTH) has an anabolic effect on both intact cancellous and cortical bone. Very little is known about the effect of the administration of PTH on the healing of fractures or the incorporation of orthopaedic implants. We have investigated the spontaneous ingrowth of callus and the formation of bone in a titanium chamber implanted at the medioproximal aspect of the tibial metaphysis of the rat. Four groups of ten male rats weighing approximately 350 g were injected with human PTH (1-34) in a dosage of 0, 15, 60 or 240 μg/kg/day, respectively, for 42 days from the day of implantation of the chamber. During the observation period the chamber became only partly filled with callus and bone and no difference in ingrowth distance into the chamber was found between the groups. The cancellous density was increased by 90%, 132% and 173% in the groups given PTH in a dosage of 15, 60 or 240 μg/kg/day, respectively. There was a linear correlation between bone density and the log PTH doses (r. 2. = 0.6). Our findings suggest that treatment with PTH may have a potential for enhancement of the incorporation of orthopaedic implants as well as a beneficial effect on the healing of fractures when it is given in low dosages


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 20 - 25
1 Jan 1997
Schreuder HWB Veth RPH Pruszczynski M Lemmens JAM Koops HS Molenaar WM

We treated 26 patients with 27 aneurysmal bone cysts by curettage and cryotherapy and evaluated local tumour control, complications and functional outcome. The mean follow-up time was 47 months (19 to154). There was local recurrence in one patient. Two patients developed deep wound infections and one had a postoperative fracture. We compared our results with previous reports in which several different methods of treatment had been used and concluded that curettage with adjuvant cryotherapy had similar results to those of marginal resection, and that no major bony reconstruction was required. We recommend the use of cryotherapy as an adjuvant to the surgical treatment of aneurysmal bone cysts. It provides local tumour control. Combination with bone grafting achieved consolidation of the lesion in all our patients


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 363 - 368
1 May 1996
Hamer AJ Strachan JR Black MM Ibbotson CJ Stockley I Elson RA

There have been conflicting reports on the effects of gamma irradiation on the material properties of cortical allograft bone. To investigate changes which result from the method of preparation, test samples must be produced with similar mechanical properties to minimise variations other than those resulting from treatment. We describe a new method for the comparative measurement of bone strength using standard bone samples. We used 233 samples from six cadavers to study the effects of irradiation at a standard dose (28 kGy) alone and combined with deep freezing. We also investigated the effects of varying the dose from 6.8 to 60 kGy (n = 132). None of the treatments had any effect on the elastic behaviour of the samples, but there was a reduction in strength to 64% of control values (p < 0.01) after irradiation with 28 kGy. There was also a dose-dependent reduction in strength and in the ability of the samples to absorb work before failure. We suggest that irradiation may cause an alteration in the bone matrix of allograft bone, but provided it is used in situations in which loading is within its elastic region, then failure should not occur


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1454
1 Nov 2018
Green CM Buckley SC Hamer AJ Kerry RM Harrison TP

Aims. The management of acetabular defects at the time of revision hip arthroplasty surgery is a challenge. This study presents the results of a long-term follow-up study of the use of irradiated allograft bone in acetabular reconstruction. Patients and Methods. Between 1990 and 2000, 123 hips in 110 patients underwent acetabular reconstruction for aseptic loosening, using impaction bone grafting with frozen, irradiated, and morsellized femoral heads and a cemented acetabular component. A total of 55 men and 55 women with a mean age of 64.3 years (26 to 97) at the time of revision surgery are included in this study. Results. At a mean follow-up of 16.9 years, there had been 23 revisions (18.7%), including ten for infection, eight for aseptic loosening, and three for dislocation. Of the 66 surviving hips (58 patients) that could be reassessed, 50 hips (42 patients; 75.6%) were still functioning satisfactorily. Union of the graft had occurred in all hips with a surviving implant. Survival analysis for all indications was 80.6% at 15 years (55 patients at risk, 95% confidence interval (CI) 71.1 to 87.2) and 73.7% at 20 years (eight patients at risk, 95% CI 61.6 to 82.5). Conclusion. Acetabular reconstruction using frozen, irradiated, and morsellized allograft bone and a cemented acetabular component is an effective method of treatment. It gives satisfactory long-term results and is comparable to other types of reconstruction. Cite this article: Bone Joint J 2018;100-B:1449–54


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 377 - 386
1 May 1960
Whiston TB Walmsley R

1. A series of experiments on adult rabbits was carried out in which a tendon was transplanted and embedded in a bony tunnel and traversed a joint after the manner of a tenodesis. 2. Histological observations were made on the reaction of surrounding bone and tendon at intervals over a period of 307 days. 3. The findings suggest that the buried tendon undergoes a process of progressive degeneration, and that host cells issuing from the adjacent bone marrow infiltrate and ultimately replace it by new tendon tissue. 4. The invading cells are believed to be derived, as a result of the provocative stimuli provided by the experiment, from primitive reticular cells of the haemopoietic tissue. 5. The tunnelled bone undergoes considerable remodelling and associated with this is the presence of a considerable number of osteoblasts and osteoclasts



The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1331 - 1347
1 Nov 2019
Jameson SS Asaad A Diament M Kasim A Bigirumurame T Baker P Mason J Partington P Reed M

Aims. Antibiotic-loaded bone cements (ALBCs) may offer early protection against the formation of bacterial biofilm after joint arthroplasty. Use in hip arthroplasty is widely accepted, but there is a lack of evidence in total knee arthroplasty (TKA). The objective of this study was to evaluate the use of ALBC in a large population of TKA patients. Materials and Methods. Data from the National Joint Registry (NJR) of England and Wales were obtained for all primary cemented TKAs between March 2003 and July 2016. Patient, implant, and surgical variables were analyzed. Cox proportional hazards models were used to assess the influence of ALBC on risk of revision. Body mass index (BMI) data were available in a subset of patients. Results. Of 731 214 TKAs, 15 295 (2.1%) were implanted with plain cement and 715 919 (97.9%) with ALBC. There were 13 391 revisions; 2391 were performed for infection. After adjusting for other variables, ALBC had a significantly lower risk of revision for any cause (hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.77 to 0.93; p < 0.001). ALBC was associated with a lower risk of revision for all aseptic causes (HR 0.85, 95% CI 0.77 to 0.95; p < 0.001) and revisions for infection (HR 0.84, 95% CI 0.67 to 1.01; p = 0.06). The results were similar when BMI was added into the model, and in a subanalysis where surgeons using only ALBC over the entire study period were excluded. Prosthesis survival at ten years for TKAs implanted with ALBC was 96.3% (95% CI 96.3 to 96.4) compared with 95.5% (95% CI 95.0 to 95.9) in those implanted with plain cement. On a population level, where 100 000 TKAs are performed annually, this difference represents 870 fewer revisions at ten years in the ALBC group. Conclusion. After adjusting for a range of variables, ALBC was associated with a significantly lower risk of revision in this registry-based study of an entire nation of primary cemented knee arthroplasties. Using ALBC does not appear to increase midterm implant failure rates. Cite this article: Bone Joint J 2019;101-B:1331–1347


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 806 - 809
1 Jun 2008
Burkhart KJ Rommens PM

We describe a patient with insufficient bone regeneration of the tibia after bone transport over an intramedullary nail, in whom union was ultimately achieved after exchange nailing and intramedullary application of rh-bone morphogenetic protein-7 at the site of distraction


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 3 | Pages 688 - 710
1 Aug 1962
Burwell RG

1. The response of the first regional lymph node to a homograft of fresh iliac cancellous bone inserted subcutaneously into the rabbit's ear three weeks after the introduction of a similar graft from the same donor into the same ear has been investigated in thirty rabbits. Fifteen rabbits which received second-set autografts of cancellous bone have also been studied. 2. The insertion of second-set homografts of fresh marrow-containing cancellous bone evokes an immune secondary response in the lymph nodes draining the grafts. 3. The increase in weight of the first regional lymph nodes on the side receiving second-set homografts is more rapid and of greater magnitude than that of nodes draining first-set homografts of cancellous bone. Second-set autografts evoke weight changes in the draining nodes similar to those in nodes draining first-set autografts of cancellous bone. 4. The histological changes which occur in the lymph nodes draining the second-set homografts (secondary response) are described and compared with those occurring in lymph nodes draining first-set homografts of cancellous bone (primary response). 5. In the primary response the distribution of large and medium lymphoid cells is throughout an activated sector of the cortex of the lymph node (Burwell and Gowland 1961), but in the secondary response these cells are found peripherally within the activated sector of the node. In both the primary and the secondary responses large and medium lymphoid cells are found in the medullary trabeculae of the lymph nodes. 6. The differences between the primary response of lymph nodes draining a tissue homograft (cancellous bone) and the primary response of lymph nodes draining classical antigens, and reported by other workers, are described. 7. Knowledge concerning the inflammatory response in the tissues of the host surrounding homografts of fresh cortical and cancellous bone implanted into animals previously sensitised to tissue from the respective donor is reviewed. 8. The late phase of new bone formation by homografts of fresh cancellous bone is discussed in the light of immunological studies


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims. Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA. Patients and Methods. In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis. Results. Significant reduction of normalized tracer activity was observed one year postoperatively in tibial and femoral VOIs adjacent to the joint line in the lateral compartment. Patellar VOIs and remaining femoral VOIs demonstrated a significant, diminished normalized tracer activity at final follow-up. Conclusion. The osteoblastic bone activity in the native compartments decreased significantly after treatment of medial end-stage OA with a UKA, implying reduced stress to the subchondral bone in the retained compartments after a UKA. Cite this article: Bone Joint J 2019;101-B:915–921



The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 214 - 221
1 May 1980
Gregg P Walder D

The early diagnosis of caisson disease of bone is hindered by the long delay which must elapse before an abnormality becomes apparent on a radiograph. The possible use of bone scintigraphy for this purpose was investigated. Necrosis of the bone and marrow was produced in rabbits by glass microspheres to simulate persistent gas-bubble emboli and then serial radiographs and scintigrams using 99mTc-diphosphonate were obtained. Regions of necrosis could be detected as "hot-spots" on the scintigrams as early as three weeks after the causative insult, which was many weeks before any abnormality could be detected on the radiographs. Histological examination of excised femora suggested that the scintigraphic abnormality might depend on the new bone formation during a reactive or repair process. It is suggested that scintigraphy may have clinical value in caisson disease


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1392 - 1398
1 Oct 2018
Willeumier JJ van de Sande MAJ van der Wal RJP Dijkstra PDS

Aims. The aim of this study was to assess the current trends in the estimation of survival and the preferred forms of treatment of pathological fractures among national and international general and oncological orthopaedic surgeons, and to explore whether improvements in the management of these patients could be identified in this way. Materials and Methods. All members of the Dutch Orthopaedic Society (DOS) and the European Musculoskeletal Oncology Society (EMSOS) were invited to complete a web-based questionnaire containing 12 cases. Results. A total of 96 of 948 members of the DOS (10.1%; groups 1 and 2) and 33 of 182 members of the EMSOS (18%; group 3) replied. The estimation of survival was accurate by more than 50% of all three groups, if the expected survival was short (< 3 months) or long (> 12 months). General orthopaedic surgeons preferred using an intramedullary nail for fractures of the humerus and femur, irrespective of the expected survival or the origin of primary tumour or the location of the fracture. Oncological orthopaedic surgeons recommended prosthetic reconstruction in patients with a long expected survival. Conclusion. Identifying patients who require centralized care, as opposed to those who can be adequately treated in a regional centre, can improve the management of patients with pathological fractures. This differentiation should be based on the expected survival, the type and extent of the tumour, and the location of the fracture. Cite this article: Bone Joint J 2018;100-B:1392–8


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 667 - 674
1 May 2018
Lauthe O Soubeyrand M Babinet A Dumaine V Anract P Biau DJ

Aims. The primary aim of this study was to determine the morbidity of a tibial strut autograft and characterize the rate of bony union following its use. Patients and Methods. We retrospectively assessed a series of 104 patients from a single centre who were treated with a tibial strut autograft of > 5 cm in length. A total of 30 had a segmental reconstruction with continuity of bone, 27 had a segmental reconstruction without continuity of bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity was defined as any event that required a modification of the postoperative management. Union was assessed clinically and radiologically at a median of 36 months (IQR, 14 to 74). Results. Donor-site morbidity occurred in four patients (4%; 95% confidence interval (CI) 1 to 10). One patient had a stress fracture of the tibia, which healed with a varus deformity, requiring an osteotomy. Two patients required evacuation of a haematoma and one developed anterior compartment syndrome which required fasciotomies. The cumulative probability of union was 90% (95% CI 80 to 96) at five years. The type of reconstruction (p = 0.018), continuity of bone (p = 0.006) and length of tibial graft (p = 0.037) were associated with the time to union. Conclusion. The tibial strut autograft has a low risk of morbidity and provides adequate bone stock for treating various defects of long bones. Cite this article: Bone Joint J 2018;100-B:667–74


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 884 - 891
1 Jul 2016
Elliott DS Newman KJH Forward DP Hahn DM Ollivere B Kojima K Handley R Rossiter ND Wixted JJ Smith RM Moran CG

This article presents a unified clinical theory that links established facts about the physiology of bone and homeostasis, with those involved in the healing of fractures and the development of nonunion. The key to this theory is the concept that the tissue that forms in and around a fracture should be considered a specific functional entity. This ‘bone-healing unit’ produces a physiological response to its biological and mechanical environment, which leads to the normal healing of bone. This tissue responds to mechanical forces and functions according to Wolff’s law, Perren’s strain theory and Frost’s concept of the “mechanostat”. In response to the local mechanical environment, the bone-healing unit normally changes with time, producing different tissues that can tolerate various levels of strain. The normal result is the formation of bone that bridges the fracture – healing by callus. Nonunion occurs when the bone-healing unit fails either due to mechanical or biological problems or a combination of both. In clinical practice, the majority of nonunions are due to mechanical problems with instability, resulting in too much strain at the fracture site. In most nonunions, there is an intact bone-healing unit. We suggest that this maintains its biological potential to heal, but fails to function due to the mechanical conditions. The theory predicts the healing pattern of multifragmentary fractures and the observed morphological characteristics of different nonunions. It suggests that the majority of nonunions will heal if the correct mechanical environment is produced by surgery, without the need for biological adjuncts such as autologous bone graft. Cite this article: Bone Joint J 2016;98-B:884–91


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 787 - 792
1 Jul 2019
Goto K Kuroda Y Kawai T Kawanabe K Matsuda S

Aims. In the 1990s, a bioactive bone cement (BABC) containing apatite-wollastonite glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl methacrylate resin was developed at our hospital. In 1996, we used BABC to fix the acetabular component in primary total hip arthroplasty (THA) in 20 patients as part of a clinical trial. The purpose of this study was to investigate the long-term results of primary THA using BABC. Patients and Methods. A total of 20 patients (three men and 17 women) with a mean age of 57.4 years (40 to 71), a mean body weight of 52.3 kg (39 to 64), and a mean body mass index (BMI) of 23.0 kg/m. 2. (19.8 to 28.6) were evaluated clinically and radiologically. Survival analyses were undertaken, and wear analyses were carried out using a computer-aided method. Results. The mean follow-up was 17.6 years (1.5 to 21.1). Radiological loosening occurred in four sockets with aseptic loosening at a mean of 7.8 years (1.5 to 20.7). Kaplan–Meier survival analyses using revision of the acetabular component, radiological loosening of the acetabular component, and the worst-case scenario with revision of the acetabular component to include the two patients lost to follow-up as endpoints yielded survival rates of 94.7%, 84.4%, and 85.0% at ten years, and 70.0%, 84.4%, and 62.8% at 20 years, respectively. Wear analysis revealed a mean linear wear rate of 0.068 mm per year. Conclusion. The long-term results of primary THAs using BABC were unsatisfactory. Its brittle nature and poor handling properties need to be improved before it becomes an alternative method of fixing the acetabular component in cemented THA. Cite this article: Bone Joint J 2019;101-B:787–792


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1152 - 1156
1 Aug 2015
Gupta S Cafferky D Cowie F Riches P Mahendra A

Extracorporeal irradiation of an excised tumour-bearing segment of bone followed by its re-implantation is a technique used in bone sarcoma surgery for limb salvage when the bone is of reasonable quality. There is no agreement among previous studies about the dose of irradiation to be given: up to 300 Gy have been used. We investigated the influence of extracorporeal irradiation on the elastic and viscoelastic properties of bone. Bone was harvested from mature cattle and subdivided into 13 groups: 12 were exposed to increasing levels of irradiation: one was not and was used as a control. The specimens, once irradiated, underwent mechanical testing in saline at 37°C. The mechanical properties of each group, including Young’s modulus, storage modulus and loss modulus, were determined experimentally and compared with the control group. . There were insignificant changes in all of these mechanical properties with an increasing level of irradiation. . We conclude that the overall mechanical effect of high levels of extracorporeal irradiation (300 Gy) on bone is negligible. Consequently the dose can be maximised to reduce the risk of local tumour recurrence. Cite this article: Bone Joint J 2015;97-B:1152–6


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1241 - 1248
1 Sep 2018
Higuchi T Yamamoto N Hayashi K Takeuchi A Abe K Taniguchi Y Kato S Murakami H Tsuchiya H

Aims. The aims of this study were to evaluate the long-term outcome of surgery for bone or soft-tissue metastases from renal cell carcinoma (RCC) and to determine factors that affect prognosis. Patients and Methods. Between 1993 and 2014, 58 patients underwent surgery for bone or soft-tissue metastases from RCC at our hospital. There were 46 men and 12 women with a mean age of 60 years (25 to 84). The mean follow-up period was 52 months (1 to 257). The surgical sites included the spine (33 patients), appendicular skeleton (ten patients), pelvis (eight patients), thorax (four patients), and soft tissue (three patients). The surgical procedures were en bloc metastasectomy in 46 patients (including 33 patients of total en bloc spondylectomy (TES)) and intralesional curettage in 12 patients. These patients were retrospectively evaluated for factors associated with prognosis. Results. The one-, three-, five-, ten-, and 15-year overall survival (OS) rates were 89%, 75%, 62%, 48%, and 25%, respectively. The median survival time (MST) was 127 months for en bloc metastasectomy and 54 months for intralesional curettage and bone grafting. The median survival time was 127 months for the spine, 140 months for lesions of the appendicular skeleton, and 54 months for the pelvis. Multivariate analysis showed that non-clear cell type RCC and metastases to more than two sites were independent risk factors for a poor prognosis. Conclusion. Patients with bone or soft-tissue metastases from a RCC have a reasonable prognosis, making surgical resection a viable option even in patients in whom the metastases are advanced. Cite this article: Bone Joint J 2018;100-B:1241–8


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1132 - 1138
1 Aug 2015
Aitken SA Jenkins PJ Rymaszewski L

The best method of managing a fracture of the distal humerus in a frail low-demand patient with osteoporotic bone remains controversial. Total elbow arthroplasty (TEA) has been recommended for patients in whom open reduction and internal fixation (ORIF) is not possible. Conservative methods of treatment, including the ‘bag of bones’ technique (acceptance of displacement of the bony fragments and early mobilisation), are now rarely considered as they are believed to give a poor functional result. We reviewed 40 elderly and low-demand patients (aged 50 to 93 years, 72% women) with a fracture of the distal humerus who had been treated conservatively at our hospital between March 2008 and December 2013, and assessed their short- and medium-term functional outcome. . In the short-term, the mean Broberg and Morrey score improved from 42 points (poor; 23 to 80) at six weeks after injury to 67 points (fair; 40 to 88) by three months. . In the medium-term, surviving patients (n = 20) had a mean Oxford elbow score of 30 points (7 to 48) at four years and a mean Disabilities of the Arm, Shoulder and Hand score of 38 points (0 to 75): 95% reported a functional range of elbow flexion. The cumulative rate of fracture union at one year was 53%. The mortality at five years approached 40%. . Conservative management of a fracture of the distal humerus in a low-demand patient only gives a modest functional result, but avoids the substantial surgical risks associated with primary ORIF or TEA. Cite this article: Bone Joint J 2015;97-B:1132–8


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 256 - 261
1 Feb 2018
Kim W Lee JS Chung HW

Aims. Adjuvant treatment after intralesional curettage for atypical cartilaginous tumours (ACTs) of long bones is widely accepted for extending surgical margins. However, evaluating the isolated effect of adjuvant treatment is difficult, and it is unclear whether not using such adjuvants provides poor oncological outcomes. Hence, we analyzed whether intralesional curettage without cryosurgery or chemical adjuvants provides poor oncological outcomes in patients with an ACT. Patients and Methods. A total of 24 patients (nine men, 15 women) (mean age 45 years; 18 to 62) were treated for ACTs of long bones and followed up for a median of 66 months (interquartile range 50 to 84). All patients were treated with extensive manual curettage and limited burring. Bone cement and grafts were used to fill bone defects in 16 and eight patients, respectively. No chemical adjuvants or cryosurgery were used. Results. No local recurrence was detectable on plain radiographs and MRI or CT images. At the last follow-up, there were no distant metastases or disease-specific deaths. No procedure-related complications or postoperative fractures developed. Conclusion. Intralesional curettage without cryosurgery or chemical adjuvants may provide excellent oncological outcomes for patients with ACTs of long bones, without the risk of complications related to adjuvant use. Our investigation suggests thorough curettage alone is a reasonable treatment option for ACT. However, we acknowledge the limited size of our investigation warrants a multicentre collaborative study to confirm our findings. Cite this article: Bone Joint J 2018;100-B:256–61


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1126 - 1131
1 Aug 2016
Shiels SM Cobb RR Bedigrew KM Ritter G Kirk JF Kimbler A Finger Baker I Wenke JC

Aims. Demineralised bone matrix (DBM) is rarely used for the local delivery of prophylactic antibiotics. Our aim, in this study, was to show that a graft with a bioactive glass and DBM combination, which is currently available for clinical use, can be loaded with tobramycin and release levels of antibiotic greater than the minimum inhibitory concentration for Staphylococcus aureus without interfering with the bone healing properties of the graft, thus protecting the graft and surrounding tissues from infection. Materials and Methods. Antibiotic was loaded into a graft and subsequently evaluated for drug elution kinetics and the inhibition of bacterial growth. A rat femoral condylar plug model was used to determine the effect of the graft, loaded with antibiotic, on bone healing. Results. We found that tobramycin loaded into a graft composed of bioglass and DBM eluted antibiotic above the minimum inhibitory concentration for three days in vitro. It was also found that the antibiotic loaded into the graft produced no adverse effects on the bone healing properties of the DBM at a lower level of antibiotic. Conclusion. This antibiotic-loaded bone void filler may represent a promising option for the delivery of local antibiotics in orthopaedic surgery. Cite this article: Bone Joint J 2016;98-B:1126–31


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims. This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect. Patients and Methods. A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively. Results. The mean time to follow-up was 55 months (12 to 126). Overall, 16 (94%) of the patients achieved radiological filling of their bony defect and united to the native bone ends proximally and distally, resulting in a functioning limb. Complications included device failure in two patients (12%), infection in two (12%), and wound dehiscence in one (6%). Four patients (24%) required secondary surgery, four (24%) had a residual limb-length discrepancy, and one (6%) had a residual angular limb deformity. Conclusion. A titanium mesh cage is a useful adjunct in the treatment of an extra-articular segmental defect in a long bone. Cite this article: Bone Joint J 2018;100-B:646–51


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 703 - 709
1 May 2016
Kim Y Kang HG Kim JH Kim S Lin PP Kim HS

Aims. The purpose of the study was to investigate whether closed intramedullary (IM) nailing with percutaneous cement augmentation is better than conventional closed nailing at relieving pain and suppressing tumours in patients with metastases of the femur and humerus. Patients and Methods. A total of 43 patients (27 men, 16 women, mean age 63.7 years, standard deviation (. sd. ) 12.2; 21 to 84) underwent closed IM nailing with cement augmentation for long bone metastases. A further 27 patients, who underwent conventional closed IM nailing, served as controls. Pain was assessed using a visual analogue scale (VAS) score pre-operatively (pre-operative VAS), one week post-operatively (immediate post-operative VAS), and at six weeks post-operatively (follow-up post-operative VAS). Progression of the tumour was evaluated in subgroups of patients using F-18-fludeoxyglucose (F-18-FDG) positron emission tomography (PET)/computed tomography (CT) and/or bone scintigraphy (BS), at a mean of 8.8 and 7.2 months post-operatively, respectively. Results. The mean pain scores of patients who underwent closed nailing with cement augmentation were significantly lower than those of the control patients post-operatively (immediate post-operative VAS: 3.8, . sd. 0.9 versus 6.0, . sd. 0.9; follow-up post-operative VAS: 3.3, . sd. 2.5 versus 6.6, . sd. 2.2; all p < 0.001). The progression of the metastasis was suppressed in 50% (10/20) of patients who underwent closed nailing with augmentation, but in only 8% (1/13) of those in the control group. Conclusion. Percutaneous cement augmentation of closed IM nailing improves the relief of pain and limits the progression of the tumour in patients with metastases to the long bones. Take home message: Percutaneous cement augmentation while performing closed IM nailing has some advantages for long bone metastases. Cite this article: Bone Joint J 2016;98-B:703–9


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 2 | Pages 344 - 345
1 May 1969
Burns-Cox CJ Higgins AT


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1542 - 1547
1 Nov 2016
Sampath Kumar V Tyrrell PNM Singh J Gregory J Cribb GL Cool P

Aims. The purpose of this study was to determine if clinical and radiological surveillance of cartilage tumours with low biological activity is appropriate. Patients and Methods. A total of 98 patients with an intramedullary cartilage neoplasm in a long bone met our inclusion criteria and were included in the study. These patients had undergone a total of 384 scans. Patients with radiological follow-up of more than three years (46 patients) were divided into two groups: an active group (11 patients) and a latent group (35 patients). Results. Active lesions had a total growth in all three planes that was > 6 mm, whilst latent lesions had < 6 mm of growth. Most latent lesions were heavily calcified: active lesions were calcified less than 50% (p = 0.025). Conclusion. Clinico-radiological surveillance can identify growing cartilage lesions: MRI is the surveillance modality of choice. A CT scan is recommended, in addition, at presentation to assess the amount of calcification within the lesion. A first follow-up MRI is suggested one year from diagnosis. If the total growth in the cartilage lesion is > 6 mm, surgical treatment should be considered. Otherwise, a second surveillance scan can be performed at three years to determine further management. Cite this article: Bone Joint J 2016;98-B:1542–7


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 358 - 364
1 Mar 2017
Torkington MS Davison MJ Wheelwright EF Jenkins PJ Anthony I Lovering AM Blyth M Jones B

Aims. To investigate the bone penetration of intravenous antibiotic prophylaxis with flucloxacillin and gentamicin during hip and knee arthroplasty, and their efficacy against Staphylococcus (S.) aureus and S. epidermidis. Patients and Methods. Bone samples from the femoral head, neck and acetabulum were collected from 18 patients undergoing total hip arthroplasty (THA) and from the femur and tibia in 21 patients during total knee arthroplasty (TKA). The concentration of both antibiotics in the samples was analysed using high performance liquid chromatography. Penetration was expressed as a percentage of venous blood concentration. The efficacy against common infecting organisms was measured against both the minimum inhibitory concentration 50, and the more stringent epidemiological cutoff value for resistance (ECOFF). Results. The bone penetration of gentamicin was higher than flucloxacillin. Relative to ECOFF, flucloxacillin concentrations were effective against S. aureus and S. epidermidis in all THAs and 20 (95%) TKAs. Gentamicin concentrations were effective against S. epidermidis in all bone samples. Gentamicin was effective against S. aureus in 11 (61.1%) femoral neck samples in THA. Effective concentrations of gentamicin against S. aureus were only achieved in four (19%) femoral and six (29%) tibial samples in TKA. Conclusion. Flucloxacillin and gentamicin were found to penetrate bone during THA and TKA. Gentamicin was effective against S. epidermidis in both THA and TKA, while levels were subtherapeutic against S. aureus in most TKAs. Bone penetration of both antibiotics was less in TKA than THA, and may relate to the use of a tourniquet. Using this antibiotic combination, effective cover against the two common infective organisms was achieved in all THAs and all but one TKA. Cite this article: Bone Joint J 2017;99-B:358–64


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 824 - 831
1 Jul 2019
Mahmoud EE Adachi N Mawas AS Deie M Ochi M

Aim. Mesenchymal stem cells (MSCs) have several properties that may support their use as an early treatment option for osteoarthritis (OA). This study investigated the role of multiple injections of allogeneic bone marrow-derived stem cells (BMSCs) to alleviate the progression of osteoarthritic changes in the various structures of the mature rabbit knee in an anterior cruciate ligament (ACL)-deficient OA model. Materials and Methods. Two months after bilateral section of the ACL of Japanese white rabbits aged nine months or more, either phosphate buffered saline (PBS) or 1 x 10. 6. MSCs were injected into the knee joint in single or three consecutive doses. After two months, the articular cartilage and meniscus were assessed macroscopically, histologically, and immunohistochemically using collagen I and II. Results. Within the PBS injection (control group), typical progressive degenerative changes were revealed in the various knee structures. In the single MSC injection (single group), osteoarthritic changes were attenuated, but still appeared, especially in the medial compartments involving fibrillation of the articular cartilage, osteophyte formation in the medial plateau, and longitudinal tear of the meniscus. In the multiple-injections group, the smoothness and texture of the articular cartilage and meniscus were improved. Histologically, absence or reduction in matrix staining and cellularity were noticeable in the control and single-injection groups, respectively, in contrast to the multiple-injections group, which showed good intensity of matrix staining and chondrocyte distribution in the various cartilage zones. Osteoarthritis Research Society International (OARSI) scoring showed significantly better results in the multiple-injections group than in the other groups. Immunohistochemically, collagen I existed superficially in the medial femoral condyle in the single group, while collagen II was more evident in the multiple-injections group than the single-injection group. Conclusion. A single injection of MSCs was not enough to restore the condition of osteoarthritic joints. This is in contrast to multiple injections of MSCs, which had the ability to replace lost cells, as well as reducing inflammation. Cite this article: Bone Joint J 2019;101-B:824–831


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 1 | Pages 208 - 208
1 Feb 1972
Wilson RI


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1626 - 1632
1 Dec 2018
Medellin MR Fujiwara T Tillman RM Jeys LM Gregory J Stevenson JD Parry M Abudu A

Aims. The aim of this paper was to investigate the prognostic factors for local recurrence in patients with pathological fracture through giant cell tumours of bone (GCTB). Patients and Methods. A total of 107 patients presenting with fractures through GCTB treated at our institution (Royal Orthopaedic Hospital, Birmingham, United Kingdom) between 1995 and 2016 were retrospectively studied. Of these patients, 57 were female (53%) and 50 were male (47%).The mean age at diagnosis was 33 years (14 to 86). A univariate analysis was performed, followed by multivariate analysis to identify risk factors based on the treatment and clinical characteristics. Results. The initial surgical treatment was curettage with or without adjuvants in 55 patients (51%), en bloc resection with or without reconstruction in 45 patients (42%), and neoadjuvant denosumab, followed by resection (n = 3, 3%) or curettage (n = 4, 4%). The choice of treatment depended on tumour location, Campanacci tumour staging, intra-articular involvement, and fracture displacement. Neoadjuvant denosumab was used only in fractures through Campanacci stage 3 tumours. Local recurrence occurred in 28 patients (25%). Surgery more than six weeks after the fracture did not affect the risk of recurrence in any of the groups. In Campanacci stage 3 tumours not treated with denosumab, en bloc resection had lower local recurrences (13%), compared with curettage (39%). In tumours classified as Campanacci 2, intralesional curettage and en bloc resections had similar recurrence rates (21% and 24%, respectively). After univariate analysis, the type of surgical intervention, location, and the use of denosumab were independent factors predicting local recurrence. Further surgery was required 33% more often after intralesional curettage in comparison with resections (mean 1.59, 0 to 5 vs 1.06, 0 to 3 operations). All patients treated with denosumab followed by intralesional curettage developed local recurrence. Conclusion. In patients with pathological fractures through GCTB not treated with denosumab, en bloc resection offers lower risks of local recurrence in tumours classified as Campanacci stage 3. Curettage or resections are both similar options in terms of the risk of local recurrence for tumours classified as Campanacci stage 2. The benefits of denosumab followed by intralesional curettage in these patients still remains unclear


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 535 - 541
1 Apr 2018
Stevenson JD Doxey R Abudu A Parry M Evans S Peart F Jeys L

Aims. Preserving growth following limb-salvage surgery of the upper limb in children remains a challenge. Vascularized autografts may provide rapid biological incorporation with the potential for growth and longevity. In this study, we aimed to describe the outcomes following proximal humeral reconstruction with a vascularized fibular epiphyseal transfer in children with a primary sarcoma of bone. We also aimed to quantify the hypertrophy of the graft and the annual growth, and to determine the functional outcomes of the neoglenofibular joint. Patients and Methods. We retrospectively analyzed 11 patients who underwent this procedure for a primary bone tumour of the proximal humerus between 2004 and 2015. Six had Ewing’s sarcoma and five had osteosarcoma. Their mean age at the time of surgery was five years (two to eight). The mean follow-up was 5.2 years (1 to 12.2). Results. The overall survival at five and ten years was 91% (confidence interval (CI) 95% 75% to 100%). At the time of the final review, ten patients were alive. One with local recurrence and metastasis died one-year post-operatively. Complications included seven fractures, four transient nerve palsies, and two patients developed avascular necrosis of the graft. All the fractures presented within the first postoperative year and united with conservative management. One patient had two further operations for a slipped fibular epiphysis of the autograft, and a hemi-epiphysiodesis for lateral tibial physeal arrest. Hypertrophy and axial growth were evident in nine patients who did not have avascular necrosis of the graft. The mean hypertrophy index was 65% (55% to 82%), and the mean growth was 4.6 mm per annum (2.4 to 7.6) in these nine grafts. At final follow-up, the mean modified functional Musculoskeletal Tumour Society score was 77% (63% to 83%) and the mean Toronto Extremity Salvage Score (TESS) was 84% (65% to 94%). Conclusion. Vascularized fibular epiphyseal transfer preserves function and growth in young children following excision of the proximal humerus for a malignant bone tumour. Function compares favourably to other limb-salvage procedures in children. Longer term analysis is required to determine if this technique proves to be durable into adulthood. Cite this article: Bone Joint J 2018;100-B:535–41


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1487 - 1490
1 Nov 2018
Teramoto A Shoji H Kura H Sakakibara Y Kamiya T Watanabe K Yamashita T

Aims. The aims of this study were to evaluate the morphology of the ankle in patients with an osteochondral lesion of the talus using 3D CT, and to investigate factors that predispose to this condition. Patients and Methods. The study involved 19 patients (19 ankles) who underwent surgery for a medial osteochondral lesion (OLT group) and a control group of 19 healthy patients (19 ankles) without ankle pathology. The mean age was significantly lower in the OLT group than in the control group (27.0 vs 38.9 years; p = 0.02). There were 13 men and six women in each group. 3D CT models of the ankle were made based on Digital Imaging and Communications in Medicine (DICOM) data. The medial malleolar articular and tibial plafond surface, and the medial and lateral surface area of the trochlea of the talus were defined. The tibial axis-medial malleolus (TMM) angle, the medial malleolar surface area and volume (MMA and MMV) and the anterior opening angle of the talus were measured. Results. The mean TMM angle was significantly larger in the OLT group (34.2°, . sd. 4.4°) than in the control group (29.2°, . sd. 4.8°; p = 0.002). The mean MMA and MMV were significantly smaller in the OLT group than in the control group (219.8 mm. 2. , . sd. 42.4) vs (280.5 mm. 2. , . sd. 38.2), and (2119.9 mm. 3. , . sd. 562.5) vs (2646.4 mm. 3. , . sd. 631.4; p < 0.01 and p = 0.01, respectively). The mean anterior opening angle of the talus was significantly larger in the OLT group than in the control group (15.4°, . sd. 3.9°) vs (10.2°, . sd. 3.6°; p < 0.001). Conclusion. 3D CT measurements showed that, in patients with a medial osteochondral lesion of the talus, the medial malleolus opens distally, the MMA and MMV are small, and the anterior opening angle of the talus is large. This suggests that abnormal morphology of the ankle predisposes to the development of osteochondral lesions of the talus. Cite this article: Bone Joint J 2018;100-B:1487–90


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 574 - 580
1 May 2007
Delloye C Cornu O Druez V Barbier O

Bone allografts can be used in any kind of surgery involving bone from minor defects to major bone loss after tumour resection. This review describes the various types of bone grafts and the current knowledge on bone allografts, from procurement and preparation to implantation. The surgical conditions for optimising the incorporation of bone are outlined, and surgeon expectations from a bone allograft discussed


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 73 - 77
1 Jan 2016
Mäkinen TJ Fichman SG Watts E Kuzyk PRT Safir OA Gross AE

An uncemented hemispherical acetabular component is the mainstay of acetabular revision and gives excellent long-term results. Occasionally, the degree of acetabular bone loss means that a hemispherical component will be unstable when sited in the correct anatomical location or there is minimal bleeding host bone left for biological fixation. On these occasions an alternative method of reconstruction has to be used. A major column structural allograft has been shown to restore the deficient bone stock to some degree, but it needs to be off-loaded with a reconstruction cage to prevent collapse of the graft. The use of porous metal augments is a promising method of overcoming some of the problems associated with structural allograft. If the defect is large, the augment needs to be protected by a cage to allow ingrowth to occur. Cup-cage reconstruction is an effective method of treating chronic pelvic discontinuity and large contained or uncontained bone defects. . This paper presents the indications, surgical techniques and outcomes of various methods which use acetabular reconstruction cages for revision total hip arthroplasty. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):73–7


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1614 - 1620
1 Nov 2010
Fini M Tschon M Ronchetti M Cavani F Bianchi G Mercuri M Alberghini M Cadossi R

Short intense electrical pulses transiently increase the permeability of the cell membrane, an effect known as electroporation. This can be combined with antiblastic drugs for ablation of tumours of the skin and subcutaneous tissue. The aim of this study was to test the efficacy of electroporation when applied to bone and to understand whether the presence of mineralised trabeculae would affect the capability of the electric field to porate the membrane of bone cells. Different levels of electrical field were applied to the femoral bone of rabbits. The field distribution and modelling were simulated by computer. Specimens of bone from treated and control rabbits were obtained for histology, histomorphometry and biomechanical testing. After seven days, the area of ablation had increased in line with the number of pulses and/or with the amplitude of the electrical field applied. The osteogenic activity in the ablated area had recovered by 30 days. Biomechanical testing showed structural integrity of the bone at both times. Electroporation using the appropriate combination of voltage and pulses induced ablation of bone cells without affecting the recovery of osteogenic activity. It can be an effective treatment in bone and when used in combination with drugs, an option for the treatment of metastases


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 877 - 877
1 Sep 1997
COHEN J