As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach. A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).Aims
Methods
Iliosacral sarcoma resections have been shown to have high rates of local recurrence (LR) and poor overall survival. There is also no universal classification for the resection of pelvic sarcomas invading the sacrum. This study proposes a novel classification system and analyzes the survival and risk of recurrence, when using this system. This is a retrospective analysis of 151 patients (with median follow-up in survivors of 44 months (interquartile range 12 to 77)) who underwent hemipelvectomy with iliosacral resection at a single centre between 2007 and 2019. The proposed classification differentiates the extent of iliosacral resection and defines types S1 to S6 (S1 resection medial and parallel to the sacroiliac joint, S2 resection through the ipsilateral sacral lateral mass to the neuroforamina, S3 resection through the ipsilateral neuroforamina, S4 resection through ipsilateral the spinal canal, and S5 and S6 contralateral sacral resections). Descriptive statistics and the chi-squared test were used for categorical variables, and the Kaplan-Meier survival analysis were performed.Aims
Methods
Orthopaedic and reconstructive surgeons are faced with large defects after the resection of malignant tumours of the sacrum. Spinopelvic reconstruction is advocated for resections above the level of the S1 neural foramina or involving the sacroiliac joint. Fixation may be augmented with either free vascularized fibular flaps (FVFs) or allograft fibular struts (AFSs) in a cathedral style. However, there are no studies comparing these reconstructive techniques. We reviewed 44 patients (23 female, 21 male) with a mean age of 40 years (SD 17), who underwent en bloc sacrectomy for a malignant tumour of the sacrum with a reconstruction using a total (n = 20), subtotal (n = 2), or hemicathedral (n = 25) technique. The reconstructions were supplemented with a FVF in 25 patients (57%) and an AFS in 19 patients (43%). The mean length of the strut graft was 13 cm (SD 4). The mean follow-up was seven years (SD 5).Aims
Methods
The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function. Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips).Aims
Materials and Methods
Patients with recurrent anterior dislocation of the shoulder commonly have an anterior osseous defect of the glenoid. Once the defect reaches a critical size, stability may be restored by bone grafting. The critical size of this defect under non-physiological loading conditions has previously been identified as 20% of the length of the glenoid. As the stability of the shoulder is load-dependent, with higher joint forces leading to a loss of stability, the aim of this study was to determine the critical size of an osseous defect that leads to further anterior instability of the shoulder under physiological loading despite a Bankart repair. Two finite element (FE) models were used to determine the risk of dislocation of the shoulder during 30 activities of daily living (ADLs) for the intact glenoid and after creating anterior osseous defects of increasing magnitudes. A Bankart repair was simulated for each size of defect, and the shoulder was tested under loading conditions that replicate Aims
Patients and Methods
The sacrum is frequently invaded by a pelvic tumour. The aim
of this study was to review our experience of treating this group
of patients and to identify the feasibility of a new surgical classification
in the management of these tumours. We reviewed 141 patients who, between 2005 and 2014, had undergone
surgical excision of a pelvic tumour with invasion of the sacrum. In a new classification, pelvisacral (Ps) I, II, and III resections
refer to a sagittal osteotomy through the ipsilateral wing of the
sacrum, through the sacral midline, or lateral to the contralateral
sacral foramina, respectively. A Ps a resection describes a pelvic
osteotomy through the ilium and a Ps b resection describes a concurrent
resection of the acetabulum with osteotomies performed through the
pubis and ischium or the pubic symphysis. Within each type, surgical
approaches were standardized to guide resection of the tumour.Aims
Patients and Methods
Aims. We aimed to investigate factors related to the technique of medial
opening wedge high tibial osteotomy which might predispose to the
development of a lateral hinge fracture. Patients and Methods. A total of 71 patients with 82 osteotomies were included in the
study. Their mean age was 62.9 years (37 to 80). The classification
of the type of osteotomy was based on whether it extended beyond
the fibular head. The
Computer hexapod assisted orthopaedic surgery (CHAOS), is a method
to achieve the intra-operative correction of long bone deformities
using a hexapod external fixator before definitive internal fixation
with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this
method in a consecutive case series of patients undergoing femoral
deformity correction, with a minimum six-month follow-up, to assess
the complications and to define the ideal group of patients for
whom this treatment is appropriate. The medical records and radiographs of all patients who underwent
CHAOS for femoral deformity at our institution between 2005 and
2011 were retrospectively reviewed. Records were available for all
55 consecutive procedures undertaken in 49 patients with a mean
age of 35.6 years (10.9 to 75.3) at the time of surgery.Aims
Patients and Methods
We wished to examine the effectiveness of tibial lengthening
using a two ring Ilizarov frame in skeletally immature patients.
This is a potentially biomechanically unstable construct which risks
the loss of axial control. We retrospectively reviewed a consecutive series of 24 boys and
26 girls, with a mean age of 8.6 years (4 to 14), who underwent
52 tibial lengthening procedures with a mean follow-up of 4.3 years
(4.0 to 16.9). Tibial alignment was measured before and after treatment
using joint orientation lines from the knee and a calculation of
the oblique plane axis.Aims
Patients and Methods
The aim of this study is to introduce and investigate the efficacy
and feasibility of a new vertebral osteotomy technique, vertebral
column decancellation (VCD), for rigid thoracolumbar kyphotic deformity
(TLKD) secondary to ankylosing spondylitis (AS). We took 39 patients from between January 2009 and January 2013
(26 male, 13 female, mean age 37.4 years, 28 to 54) with AS and
a TLKD who underwent VCD (VCD group) and compared their outcome
with 45 patients (31 male, 14 female, mean age 34.8 years, 23 to
47) with AS and TLKD, who underwent pedicle subtraction osteotomy
(PSO group), according to the same selection criteria. The technique
of VCD was performed at single vertebral level in the thoracolumbar
region of AS patients according to classification of AS kyphotic
deformity. Pre- and post-operative chin-brow vertical angle (CBVA),
sagittal vertical axis (SVA) and sagittal Cobb angle in the thoracolumbar
region were reviewed in the VCD and PSO groups. Intra- , post-operative
and general complications were analysed in both group.Aims
Patients and Methods
This animal study compares different methods
of performing an osteotomy, including using an Erbium-doped Yttrium
Aluminum Garnet laser, histologically, radiologically and biomechanically.
A total of 24 New Zealand rabbits were divided into four groups
(Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical
saw blade and Group IV: laser). A proximal transverse diaphyseal
osteotomy was performed on the right tibias of the rabbits after the
application of a circular external fixator. The rabbits were killed
six weeks after the procedure, the operated tibias were resected
and radiographs taken. The specimens were tested biomechanically using three-point bending
forces, and four tibias from each group were examined histologically.
Outcome parameters were the biomechanical stability of the tibias
as assessed by the failure to load and radiographic and histological
examination of the osteotomy site. The osteotomies healed in all specimens both radiographically
and histologically. The differences in the mean radiographic (p
= 0.568) and histological (p = 0.71) scores, and in the mean failure
loads (p = 0.180) were not statistically significant between the
groups. Different methods of performing an osteotomy give similar quality
of union. The laser osteotomy, which is not widely used in orthopaedics
is an alternative to the current methods. Cite this article:
We report our experience of using a computer
navigation system to aid resection of malignant musculoskeletal tumours
of the pelvis and limbs and, where appropriate, their subsequent
reconstruction. We also highlight circumstances in which navigation
should be used with caution. We resected a musculoskeletal tumour from 18 patients (15 male,
three female, mean age of 30 years (13 to 75) using commercially
available computer navigation software (Orthomap 3D) and assessed
its impact on the accuracy of our surgery. Of nine pelvic tumours,
three had a biological reconstruction with extracorporeal irradiation,
four underwent endoprosthetic replacement (EPR) and two required
no bony reconstruction. There were eight tumours of the bones of
the limbs. Four diaphyseal tumours underwent biological reconstruction.
Two patients with a sarcoma of the proximal femur and two with a
sarcoma of the proximal humerus underwent extra-articular resection
and, where appropriate, EPR. One soft-tissue sarcoma of the adductor
compartment which involved the femur was resected and reconstructed
using an EPR. Computer navigation was used to aid reconstruction
in eight patients. Histological examination of the resected specimens revealed tumour-free
margins in all patients. Post-operative radiographs and CT showed
that the resection and reconstruction had been carried out as planned
in all patients where navigation was used. In two patients, computer
navigation had to be abandoned and the operation was completed under
CT and radiological control. The use of computer navigation in musculoskeletal oncology allows
accurate identification of the local anatomy and can define the
extent of the tumour and proposed resection margins. Furthermore,
it helps in reconstruction of limb length, rotation and overall
alignment after resection of an appendicular tumour. Cite this article:
Giant cell tumour is the most common aggressive
benign tumour of the musculoskeletal system and has a high rate of
local recurrence. When it occurs in proximity to the hip, reconstruction
of the joint is a challenge. Options for reconstruction after wide
resection include the use of a megaprosthesis or an allograft-prosthesis
composite. We performed a clinical and radiological study to evaluate
the functional results of a proximal femoral allograft-prosthesis
composite in the treatment of proximal femoral giant cell tumour
after wide resection. This was an observational study, between 2006
and 2012, of 18 patients with a mean age of 32 years (28 to 42)
and a mean follow-up of 54 months (18 to 79). We achieved excellent
outcomes using Harris Hip Score in 13 patients and a good outcome
in five. All allografts united. There were no complications such
as infection, failure, fracture or resorption of the graft, or recurrent
tumour. Resection and reconstruction of giant cell tumours with
proximal femoral allograft–prosthesis composite is a better option
than using a prosthesis considering preservation of bone stock and excellent
restoration of function. A good result requires demanding bone banking techniques, effective
measures to prevent infection and stability at the allograft-host
junction. Cite this article:
Many different lengths of stem are available
for use in primary total hip replacement, and the morphology of
the proximal femur varies greatly. The more recently developed shortened
stems provide a distribution of stress which closely mimics that
of the native femur. Shortening the femoral component potentially
comes at the cost of decreased initial stability. Clinical studies
on the performance of shortened cemented and cementless stems are promising,
although long-term follow-up studies are lacking. We provide an
overview of the current literature on the anatomical features of
the proximal femur and the biomechanical aspects and clinical outcomes
associated with the length of the femoral component in primary hip
replacement, and suggest a classification system for the length
of femoral stems. Cite this article:
We report our early experience with the use of
a new prosthesis, the Modular Hemipelvic Prosthesis II, for reconstruction
of the hemipelvis after resection of a primary malignant peri-acetabular
tumour involving the sacroiliac joint. We retrospectively reviewed the outcome of 17 patients who had
undergone resection of a pelvic tumour and reconstruction with this
prosthesis between July 2002 and July 2010. One patient had a type I+II+III+IV resection (ilium + peri-acetabulum
+ pubis/ischium + sacrum) and 16 had a type I+II+IV resection (ilium
+ acetabulum + sacrum). The outcome was assessed at a mean follow-up
of 33 months (15 to 59). One patient was alive with disease, 11
were alive without disease and five had died of disease. The overall
five-year survival rate was 62.4%. Six patients had a local recurrence.
The mean Musculoskeletal Tumour Society score was 58% (33 to 77).
Deep infection occurred in two patients, problems with wound healing
in five and dislocation in one. For patients with a primary malignant peri-acetabular sarcoma
involving the sacroiliac joint, we believe that this new prosthesis
is a viable option for reconstruction of the bony defect left following
resection of the tumour. It results in a satisfactory functional
outcome with an acceptable rate of complications. Cite this article:
Using human cadaver specimens, we investigated
the role of supplementary fibular plating in the treatment of distal
tibial fractures using an intramedullary nail. Fibular plating is
thought to improve stability in these situations, but has been reported
to have increased soft-tissue complications and to impair union
of the fracture. We proposed that multidirectional locking screws
provide adequate stability, making additional fibular plating unnecessary.
A distal tibiofibular osteotomy model performed on matched fresh-frozen
lower limb specimens was stabilised with reamed nails using conventional
biplanar distal locking (CDL) or multidirectional distal locking
(MDL) options with and without fibular plating. Rotational stiffness
was assessed under a constant axial force of 150 N and a superimposed
torque of ± 5 Nm. Total movement, and neutral zone and fracture
gap movement were analysed. In the CDL group, fibular plating improved stiffness at the tibial
fracture site, albeit to a small degree (p = 0.013). In the MDL
group additional fibular plating did not increase the stiffness.
The MDL nail without fibular plating was significantly more stable
than the CDL nail with an additional fibular plate (p = 0.008). These findings suggest that additional fibular plating does not
improve stability if a multidirectional distal locking intramedullary
nail is used, and is therefore unnecessary if not needed to aid
reduction. Cite this article:
We have investigated the benefits of patient
specific instrument guides, applied to osteotomies around the knee. Single,
dual and triple planar osteotomies were performed on tibias or femurs
in 14 subjects. In all patients, a detailed pre-operative plan was
prepared based upon full leg standing radiographic and CT scan information.
The planned
Fracture repair occurs by two broad mechanisms:
direct healing, and indirect healing with callus formation. The effects
of bisphosphonates on fracture repair have been assessed only in
models of indirect fracture healing. A rodent model of rigid compression plate fixation of a standardised
tibial osteotomy was used. Ten skeletally mature Sprague–Dawley
rats received daily subcutaneous injections of 1 µg/kg ibandronate
(IBAN) and ten control rats received saline (control). Three weeks
later a tibial osteotomy was rigidly fixed with compression plating.
Six weeks later the animals were killed. Fracture repair was assessed
with mechanical testing, radiographs and histology. The mean stress at failure in a four-point bending test was significantly
lower in the IBAN group compared with controls (8.69 Nmm-2 ( Bisphosphonate treatment in a therapeutic dose, as used for risk
reduction in fragility fractures, had an inhibitory effect on direct
fracture healing. We propose that bisphosphonate therapy not be
commenced until after the fracture has united if the fracture has
been rigidly fixed and is undergoing direct osteonal healing. Cite this article:
We analysed the clinical and radiological outcomes
of a new surgical technique for the treatment of heterozygote post-axial
metatarsal-type foot synpolydactyly with HOX-D13 genetic mutations
with a mean follow-up of 30.9 months (24 to 42). A total of 57 feet
in 36 patients (mean age 6.8 years (2 to 16)) were treated with
this new technique, which transfers the distal part of the duplicated
fourth metatarsal to the proximal part of the fifth metatarsal.
Clinical and radiological assessments were undertaken pre- and post-operatively
and any complications were recorded. Final outcomes were evaluated
according to the methods described by Phelps and Grogan. Forefoot width
was reduced and the lengths of the all reconstructed toes were maintained
after surgery. Union was achieved for all the metatarsal osteotomies
without any angular deformities. Outcomes at the final assessment
were excellent in 51 feet (89%) and good in six (11%). This newly
described surgical technique provides for painless, comfortable
shoe-wearing after a single, easy-to-perform operation with good
clinical, radiological and functional outcomes. Cite this article: