The COVID-19 pandemic presents an unprecedented burden on global healthcare systems, and existing infrastructures must adapt and evolve to meet the challenge. With health systems reliant on the health of their workforce, the importance of protection against disease transmission in healthcare workers (HCWs) is clear. This study collated responses from several countries, provided by clinicians familiar with practice in each location, to identify areas of best practice and policy so as to build consensus of those measures that might reduce the risk of transmission of COVID-19 to HCWs at work. A cross-sectional descriptive survey was designed with ten open and closed questions and sent to a representative sample. The sample was selected on a convenience basis of 27 senior surgeons, members of an international surgical society, who were all frontline workers in the COVID-19 pandemic. This study was reported according to the Standards for Reporting Qualitative Research (SRQR) checklist.Aims
Methods
Effectiveness of computer-assisted joint replacement (CA-TJR) compared to conventional TJR has been evaluated by a large body of literature. Systematic reviews provide a powerful, widely accepted, evidence-based approach to synthesize the evidence and derive conclusions, yet the strength of these conclusions is dependent on the quality of the review. Multiple systematic reviews compared CA-TJR and conventional TJR with conflicting results. We aimed to assess the quality of these reviews. We searched MEDLINE, EMBASE, the Cochrane, and Epistemonikos to identify SRs published through May 2017. Full-text articles that met inclusion criteria were retrieved and assessed independently by two reviewers. Evidence was qualitatively synthesized and summarized. Outcome measures were categorized into functional, radiological, and patient safety related. The corrected covered area (CCA) was calculated to assess the degree of overlap between SRs in analyzing the same primary studies. The AMSTAR 2, a valid and reliable tool, was applied to rate the confidence in the results of the SRs (Shea et al., 2017). AMSTAR-2 has 16 domains, of which 7 are critical (e.g., justification for excluding individual studies) and 9 are non-critical (e.g., not reporting conflict of interest for individual studies). Reviews are rated as high (no critical or non-critical flaws), moderate (only non-critical flaws), low (1 critical flaw) and critically low (more than one critical flaw). Disagreement between the 2 reviewers was resolved by discussion with the senior author to achieve consensus. We reported the quality ratings of these studies and the frequency of critical and non-critical flaws.Background
Methods
Recent work has shown that joint contracture severity can be decreased with the mast cell stabilizer ketotifen in association with decreased numbers of myofibroblasts and mast cells in the joint capsule of a rabbit model of post-traumatic contractures. Neuropeptides such as Substance P (SP) can induce mast cells to release growth factors. Using a gel contraction assay, we test the hypothesis that joint capsule cell-mediated contraction of a collagen gel can be enhanced with SP, but the effect is magnified in the presence of mast cells. Anterior elbow joint capsules were obtained at the time of surgical release from 2 men (age 34 and 54) and 1 woman (age 40) with chronic (> 1 year) post-traumatic joint contractures. The human mast cell line HMC-1 (Mayo Clinic, Rochester), SP and the NK1 receptor antagonist RP67580 (Sigma, Oakville, ON) were used. NK1 is the SP receptor. Neutralized Collagen solution composed with 58% Vitrogen 100 purified collagen mixed with HMC-1 cells only (7.5 105), human capsule cells (2.5 105), or human capsule cells (2.5 105) and 7.5 105 mast cells (1:3) were cast into 24- well tissue culture plates. In some experiments, SP (1 × 10−5 M) +/− RP67580 (0.5 mM) were added. The gels were maintained with 0.5 ml DMEM composed with 2% BSA and incubated at 37C for 12 h for gelation to occur. The gels were then detached from the wall and the bottom of culture plate wells, and photographed at regular intervals up to 72 hours. Gel contraction studies were carried out on passage 4 and done in triplicate for each patient. The average value of each patients triplicate was combined to give a mean contraction at each time point. Statistical analysis involved an ANOVA with posthoc Bonferroni correction. P < 0.001 was significant.Purpose
Method