Limb length disparity is a frequent complication after hip surgery inducing many surgeon-patients conflicts. To date no study has been able to precisely quantify such limb length disparity. EOS® system, currently validated to measure lower limb parameters, allows from two bi-dimensional numerical orthogonal radiographies in standing position to obtain a tri-dimensional reconstruction of lower limbs. A computerized system achieves the parameters calculation. The aim of this study is to precisely measure the limb length disparities and the other hip parameters following total hip arthroplasty surgical procedure, by using a standard X-rays and using EOS® three-dimensional reconstructions. Twenty-eight patients programmed for total hip arthroplasty have been included (i.e. thirty lower limbs). Two independent performers have carried out twice the measures either on standard X-rays and using three-dimensional reconstructions of the lower limb disparities prior and after the surgical procedure. The inter and intra-observer reproducibility for the measure of the lower limb disparities have been of the EOS® measures have been respectively of 0.854 and 0.865 and for the standard X-rays of 0.717 and 0.726. Mean length disparity observed was before Total Hip Arthroplasty of −0.328 cm (0.705; −1.266/0.530) and was of 0.088 mm (1.326; −1.635/0.632) after. We are able to decrease the lower limbs disparity in 69.1% and for the average of 0,416cm. Using EOS® system has allowed assessing with greater precision the possibility to restore equal lower limb length. This assessment has permitted introducing a new planning procedure including EOS® imaging associated to the fusion of the prosthetic tri-dimensional image in order to achieve adequate lower limb length.
Osteoporosis is a metabolic disease of the bone responsible for a loss of bone resistance and an increase in fracture risk. World Health Organization (WHO) estimations are about 6.3 millions of femoral neck fractures in the world by 2050. These estimations make osteoporosis a real problem in term of public health. Knowledge in biological tissues mechanical behaviour and its evolution with age are important for the design of diagnosis and therapeutic tools. From the mechanical aspect, bone resistance is dependent on bone density, bone architecture and bone tissue quality. If the importance of bone density and bone architecture has been well explored, the bone tissue quality still remains unstudied because of the lack of biomechanical tools suitable for testing bone at this microscopic dimension. Therefore the goal of this study is to estimate the osteoporotic cancellous bone tissue mechanical behaviour at its microscopic scale, using an approach coupling mechanical assays and digital reconstruction. The experimental study is based on cancellous bone tissue extracted from human femoral head. Forty 8mm diameters bone cylinders have been removed from femoral head explanted after a femoral neck fracture treated by arthroplasty. These cylinders have been submitted to a digitally controlled compressive trial. Before and after the trials, microscanner analyses with an 8 μm spatial resolution have been realized in order to determine the micro structural parameters. The cylinders have been rebuilt with the digital model-building in order to estimate the mechanical behaviour and the bone quality.Introduction
Materials and methods
The purpose of this prospective randomized study was to compare the 2-year follow-up penetration of Oxinium versus Metal on polyethylene in a consecutive series of low friction total hip arthroplasty. Between July 2006 and May 2006, 50 patients (27 females and 23 males) with a mean age of 60.6 ± 11.4 years (21 to 75) were randomized to receive either Oxinium (25 hips) or Metal (25 hips) femoral head. Other parameters, including the femoral component and the all polyethylene socket (EtO sterilized), were identical in both groups. The primary criterion for evaluation was linear head penetration measurement using the Martell system.Introduction
Methods
To date, no technique has proved to be reliable and reproducible in order to precisely calculate radiological lower limb parameters. EOS® system allows from two bi-dimensional orthogonal radiographies in standing position to obtain a tridimensional reconstruction. A computerized system achieves the parameters calculation. The aim of the study was first to evaluate the inter and intraobserver reproducibility of the EOS® system, secondly to compare EOS® measures with X-ray orthoroentgenograms. Twenty-five patients about to receive total hip arthroplasty were included (fifty lower limbs). Two independent performers have carried out twice the measures either on standard X-rays and using three-dimensional reconstructions (femoral parameters (length, offset, collo-diaphy-seal angle, neck length, and head diameter), tibiae length, limb length, HKA, HKS). The reproducibility was estimated by intraclass correlation coefficients. The inter and intraobserver reproducibility of the EOS® measures have been respectively of 0.881 and 0.916 and more specifically of 0,997 and 0,997 for femoral length, of 0.996 and 0.997 for tibiae, of 0.999 and 0.999 for limb length, of 0.893 and 0.890 for HKS, of 0.993 and 0.994 for HKA, of 0.892 and 0.914 for femoral offset, of 0.765 and 0.850 for collo-diaphyseal angle. The inter and intraobserver reproducibility using orthoroentgenograms reached 0.854 and 0.902.
Its use prior to the decision of surgery and during surgery planning for lower limb arthroplasty is for us essential for adjusting surgical procedure accordingly.