Objective

Guidelines published by the British Association of Spine Surgeons (BASS) and Society of British Neurological Surgeons (SBNS) recommend urgent MRI imaging and intervention in individuals suspected of having CES. The need for an evidence based protocol is driven by a lack of 24/7 MRI services and centralisation of neurosurgery to tertiary centres, compounded by CES's significant medico-legal implications. We conducted an audit to evaluate the pathway for suspected CES in BCUHB West between 2018 and 2021.

Methods

A retrospective audit of patients managed for suspected CES between 01/11/2018 and 01/05/2021 was performed, using the SBNS/BASS guidelines as the standard.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 6 - 6
3 Mar 2023
Ramage G Poacher A Ramsden M Lewis J Robertson A Wilson C
Full Access

Introduction

Virtual fracture clinics (VFC's) aim to reduce the number of outpatient appointments while improving the clinical effectiveness and patients experience through standardisation of treatment pathways. With 4.6% of ED admissions due to trauma the VFC prevents unnecessary face to face appointments providing a cost savings benefit to the NHS.

Methods

This project demonstrates the importance of efficient VFC process in reducing the burden on the fracture clinics. We completed preformed a retrospective cross-sectional study, analysing two cycles in May (n=305) and September (n=332) 2021. We reviewed all VFC referrals during this time assessing the quality of the referral, if they went on to require a face to face follow up and who the referring health care professional was. Following the cycle in May we provided ongoing education to A&E staff before re-auditing in September.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 1 - 1
3 Mar 2023
Kinghorn AF Whatling G Bowd J Wilson C Holt C
Full Access

This study aimed to examine the effect of high tibial osteotomy (HTO) on the ankle and subtalar joints via analysis of static radiographic alignment. We hypothesised that surgical alteration of the alignment of the proximal tibia would result in compensatory distal changes.

35 patients recruited as part of the wider Biomechanics and Bioengineering Centre Versus Arthritis HTO study between 2011 and 2018 had pre- and postoperative full-length weightbearing radiographs taken of their lower limbs. In addition to standard alignment measures of the limb and knee (mechanical tibiofemoral angle, Mikulicz point, medial proximal tibial angle), additional measures were taken of the ankle/subtalar joints (lateral distal tibial angle, ground-talus angle, joint line convergence angle of the ankle) as well as a novel measure of stance width. Results were compared using a paired T-test and Pearson's correlation coefficient.

Following HTO, there was a significant (5.4°) change in subtalar alignment. Ground-talus angle appeared related both to the level of malalignment preoperatively and the magnitude of the alignment change caused by the HTO surgery; suggesting subtalar positioning as a key adaptive mechanism. In addition to compensatory changes within the subtalar joints, the patients on average had a 31% wider stance following HTO. These two mechanisms do not appear to be correlated but the morphology of the tibial plafond may influence which compensatory mechanisms are employed by different subgroups of HTO patients.

These findings are of vital importance in clinical practice both to anticipate potential changes to the ankle and subtalar joints following HTO but it could also open up wider indications for HTO in the treatment of ankle malalignment and osteoarthritis.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 58 - 58
1 Feb 2021
Sires J Wilson C
Full Access

Robotic-assisted technology in total knee arthroplasty (TKA) aims to increase implantation accuracy, with real-time data being used to estimate intraoperative component alignment. Postoperatively, Perth computed tomography (CT) protocol is a valid measurement technique in determining both femoral and tibial component alignments. The aim of this study was to evaluate the accuracy of intraoperative component alignment by robotic-assisted TKA through CT validation. A total of 33 patients underwent TKA using the MAKO robotic-assisted TKA system. Intraoperative measurements of both femoral and tibial component placements, as well as limb alignment as determined by the MAKO software were recorded. Independent postoperative Perth CT protocol was obtained (n.29) and compared with intraoperative values. Mean absolute difference between intraoperative and postoperative measurements for the femoral component were 1.17 degrees (1.10) in the coronal plane, 1.79 degrees (1.12) in the sagittal plane, and 1.90 degrees (1.88) in the transverse plane. Mean absolute difference between intraoperative and postoperative measurements for the tibial component were 1.03 degrees (0.76) in the coronal plane and 1.78 degrees (1.20) in the sagittal plane. Mean absolute difference of limb alignment was 1.29 degrees (1.25), with 93.10% of measurements within 3 degrees of postoperative CT measurements. Overall, intraoperatively measured component alignment as estimated by the MAKO robotic-assisted TKA system is comparable to CT-based measurements.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 160 - 166
22 May 2020
Mathai NJ Venkatesan AS Key T Wilson C Mohanty K

Aims

COVID-19 has changed the practice of orthopaedics across the globe. The medical workforce has dealt with this outbreak with varying strategies and adaptations, which are relevant to its field and to the region. As one of the ‘hotspots’ in the UK , the surgical branch of trauma and orthopaedics need strategies to adapt to the ever-changing landscape of COVID-19.

Methods

Adapting to the crisis locally involved five operational elements: 1) triaging and workflow of orthopaedic patients; 2) operation theatre feasibility and functioning; 3) conservation of human resources and management of workforce in the department; 4) speciality training and progression; and 5) developing an exit strategy to resume elective work. Two hospitals under our trust were redesignated based on the treatment of COVID-19 patients. Registrar/consultant led telehealth reviews were carried out for early postoperative patients. Workflows for the management of outpatient care and inpatient care were created. We looked into the development of a dedicated operating space to perform the emergency orthopaedic surgeries without symptoms of COVID-19. Between March 23 and April 23, 2020, we have surgically treated 133 patients across both our hospitals in our trust. This mainly included hip fractures and fractures/infection affecting the hand.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 6 - 6
1 Apr 2019
Wilson C Singh V
Full Access

Introduction

The intra-operative diagnosis of Prosthetic Joint Infection (PJI) is a dilemma requiring intra-operative sampling of suspicious tissues for frozen section, deep tissue culture and histopathology to secure a diagnosis. Alfa defensin-1 testing has been introduced as a quick and reliable test for confirming or ruling out PJI. This study aims to assess its intra-operative reliability compared to the standard tests.

Methods

Twenty patients who underwent revision hip and knee arthroplasty surgery were included. Patients joint aspirate was tested intra-operatively with the Synovasure kit, which takes approximately ten minutes for a result. Our standard protocol of collecting 5 deep tissue samples for culture and one sample for histopathology was followed. Results for Alfa defensin-1 test were then compared with final culture and histopathology results in all these patients.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 4 - 4
1 Apr 2019
Wilson C Inglis M George D
Full Access

Introduction

Revision total hip arthroplasty is a complex procedure and becoming more common. Acetabular implant loosening or fracture has previously been treated with a cup and cage construct. Recent studies have shown significant failure rates with Cup Cage constructs in more complex 3B and 3C Acetabular revisions. As a result the use of 3D printed custom made acetabular components has become more common.

Method

We present 5 cases with severe acetabular bone loss that were treated with 3D printed acetabular components. The components were manufactured by OSSIS medical in New Zealand. The patient's original femoral stem was retained in all cases. Pre operatively the implant design was approved by the arthroplasty team prior to final manufacture. Implants were provided with a sterilisable model used intraoperatively for reference.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 5 - 5
1 Apr 2019
Wilson C Sires J Lennon S Inglis M
Full Access

Introduction

Despite improvement in implants and surgical techniques up to 20% of Total Knee Arthroplasty TKA patients continue to report dissatisfaction. The ATTUNE Knee System was designed to provide better patellar tracking and stability through the mid-range of flexion and therefore improve patient outcomes and satisfaction.

Aims

The aims of this study were to assess patient outcomes in a consecutive series of ATTUNE TKA and ensure early results were comparable to other TKA systems in Australia.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2019
Wilson C Critchely O Callary S Campbell D
Full Access

Introduction & aims

The magnitude and pattern of acceptable migration in clinically successful cementless stems is not well understood. Radiostereometric analysis (RSA) is a well-recognised method of assessing implant migration.

Previous studies have reported long term RSA results for cemented stems. The aim of this study was to assess the long-term migration characteristics of the Corail hydroxyapatite-coated cementless stem at 10 years using RSA.

Method

A prospective cohort of 30 patients undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration behaviour of a cementless stem. Tantalum markers were attached to the stem and placed in the bone intraoperatively, allowing for RSA measurements to be taken in vivo. Previous 5-year results have been presented.

A total of 14 patients (total 15 hips, one bilateral) with mean age 82 years (range, 69–92 years) underwent repeat long-term RSA radiographs at minimum 10 years post op. The mean time to follow up was 13.9 years (range, 13.3–14.4 years). The RSA radiographs were analysed to assess for implant rotation and translation.


Total knee arthroplasty is associated with early postoperative pain. Appropriate pain management is important to facilitate postoperative rehabilitation and positive functional outcomes. This study compares outcomes in TKA with three techniques; local infiltration analgesia, single shot femoral nerve block and intrathecal morphine.

Methods

Forty-five patients undergoing elective primary Total Knee Arthroplasty (TKA) with were randomized into one of three groups in a double blind proof of concept study.

Study arm 1 received local infiltration analgesia ropivacaine intra-operatively, an elastomeric device of ropivacaine for 24 hours post-op.

Study arm 2 received a femoral nerve block of ropivacaine with placebo local infiltration analgesia and placebo intrathecal morphine.

Study arm 3 received intrathecal morphine, placebo femoral nerve block and placebo local infiltration analgesia. All patients received standardized pre-operative, intraoperative and Post-operative analgesic medication.

Participants were mobilized at 4 hrs, 24hrs and 48 hrs post operation. Range of Motion, Visual Analogue Scale (VAS) pain intensity scores and two minute walk test and Timed Up and Go test were performed. Postoperative use of analgesic drugs was recorded. Knee Society Score (KSS), Oxford Knee Score and Knee Injury and Osteoarthritis Outcome Score (KOOS) were completed at preoperative and 6 weeks post op.

Results

Preliminary results of 32 participants convey the positive outcomes after total knee replacement demonstrated by the improvement in Oxford Knee Score and Knee Osteoarthritis Outcome score. There are marked improvements in the 2-minute walk tests at the six week time-point. At day one post-operative only 5 participants were unable to walk. Patient-controlled analgesia was used on 5 occasions on day one, 2 of which continued on day two. Sedation scores were recorded in six participants on day one and 2 on day two. Nausea was reported in 5 cases on day one and 9 on day two. Urinary catheter was needed in 5 cases on day one.

Importantly the study remains blinded, therefore an analysis of the three study arms is not available and is therefore currently difficult to report on the statistical significance. There will be further assessment of the efficacy of analgesia using VAS pain scores, analgesia consumption and side effects collected preoperatively, 0–24hrs and 24–48 hours postoperatively between the three randomized groups. The assessment of functional outcomes will be measured between the three groups by comparing the ability to mobilize the first 4 hrs after surgery, maximal flexion and extension, two minute walk test and timed up-and-go preoperatively, on postoperative day 1 and 2 and 6 weeks.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 132 - 132
1 May 2016
Wilson C
Full Access

Introduction

Patients undergoing total knee arthroplasty have expected blood loss during and after surgery. The current literature remains inconclusive in regards to which surgical instrumentation techniques in total knee arthroplasty are effective in minimising peri-operative blood loss. The primary objective of this retrospective review of a prospective randomized cohort study is to compare surgical and patient factors and their influence on blood loss and transfusions rates between one type of Patient Specific Instrumentation (PSI) (SignatureTM), Navigated Computer-Assisted Surgery (CAS) and Conventional Total Knee Arthroplasty (TKA) surgical techniques.

Method

128 matched patients (38 SignatureTM, 44 CAS, 46 Conventional surgeries) were compared. Pre-operative factors were analysed including; age, gender, Body Mass Index (BMI), pre-operative hemoglobin (g/L), International Normalized Ratio (INR), use of anticoagulants and co-morbid bleeding diathesis. Maximal hemoglobin drop were compared on Day 1 to 3, as well as, transfusion requirement. Peri-operative factors were collected including; surgical time, tourniquet time, drain output, insitu drain time, order of tibia or femoral cut and intra-operative loss from suction.


Background

Total knee arthroplasty is associated with early postoperative pain. Appropriate pain management is important to facilitate postoperative rehabilitation and positive functional outcomes. This study compares outcomes in TKA with three techniques; local infiltration analgesia, single shot femoral nerve block and intrathecal morphine.

Methods

Forty-five patients undergoing elective primary Total Knee Arthroplasty (TKA) with were randomized into one of three groups in a double blind proof of concept study. Study arm 1 received local infiltration analgesia ropivacaine intra-operatively, an elastomeric device of ropivacaine for 24 hours post-op. Study arm 2 received a femoral nerve block of ropivacaine with placebo local infiltration analgesia and placebo intrathecal morphine. Study arm 3 received intrathecal morphine, placebo femoral nerve block and placebo local infiltration analgesia. All patients received standardized pre-operative, intraoperative and Post-operative analgesic medication.

Participants were mobilized at 4 hrs, 24hrs and 48 hrs post operation. Range of Motion, Visual Analogue Scale (VAS) pain intensity scores and two minute walk test and Timed Up and Go test were performed. Postoperative use of analgesic drugs was recorded. Knee Society Score (KSS), Oxford Knee Score and Knee Injury and Osteoarthritis Outcome Score (KOOS) were completed at preoperative and 6 weeks post op.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 26 - 26
1 Jan 2016
Stevens A Hussenbocus S Wilson C Mercer G Krishnan J
Full Access

Introduction

Total hip replacement (THR) is a very common procedure performed for the treatment of osteoarthritis of the hip. The aim of THR is to restore function and quality of life of the patients, by restoring femoral offset, leg length, centre of rotation, and achieving stability, to avoid dislocation postoperatively.

Method

We aimed to perform preoperative assessment of femoral offset on anteroposterior (AP) radiographs of the hip, and on corresponding CT scans, for patients undergoing primary THR. Patients were positioned according to a standardised protocol prior to obtaining radiographs of the hip and CT scan. Inter- and intra-observer reliability was evaluated between 3 observers of differing levels of seniority – an orthopaedic trainee, a fellow, and a consultant. CT scan measurements of offset were performed by one consultant radiologist. The researchers measuring radiographic offset were blinded to the results of the CT measurements.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 132 - 132
1 Jan 2016
Watts A Williams B Krishnan J Wilson C
Full Access

Background

Shoulder impingement syndrome (SIS) is a common debilitating condition, treated across multiple health disciplines including Orthopaedics, Physiotherapy, and Rheumatology. There is little consistency in diagnostic criteria with ‘Shoulder impingement syndrome’ being used for a broad spectrum of complex pathologies. We assessed patterns in diagnostic procedures for SIS across multiple disciplines.

Methods

This is a systematic review of electronic databases MEDLINE, PubMed, The Cochrane Library, Embase, Scopus and CINAHL five years of publications, January 2009 - January 2014. Search terms for SIS included subacromial impingement syndrome, subacromial bursitis. Searches were delimited to articles written in English. The PRISMA guidelines were followed. Two reviewers independently screened all articles, data was then extracted by one reviewer and twenty percent of the extraction was independently assessed by the co-reviewer. Studies included were intervention studies examining individuals diagnosed with SIS and we were interested in the process and method used for the diagnosis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 27 - 27
1 Jan 2016
Stevens A Wilson C Mercer G Krishnan J
Full Access

Introduction

There are conflicting views when assessing the best imaging modality by which to assess long leg alignment pre and post operatively for patients’ receiving primary total hip replacements. It has been a long standing standard that long-leg radiographs are used for measuring and interpreting alignment of the lower limb, but recently it has been suggested that CT imaging may be a better option for this assessment.

Methods

Patients awaiting total knee replacement surgeries were invited to participate in this clinical trial. 120 participants’ consented and completed both pre and post-operative long-leg radiographs, and lower limb CT scans. Long leg radiographs were analysed and measured by senior orthopaedic surgeons pre and post-operatively, while CT scans were analysed using the perth protocol method by trained radiologists. Mechanical alignment of the lower limb was calculated using both imaging modalities, the CT “scout” scan was used for the measurement of the mechanical alignment.

Pre-operatively the patients had their imaging performed between 1 year and 1 week pre-operatively, and following surgery their imaging was standardised to 6 months post-operatively. For long leg radiographs, patients were asked to stand with their feet shoulder width apart and toes forward facing (on occasion deformities would not allow for this stance, and they were asked to adopt this stance to the best of their ability).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 130 - 130
1 Jan 2016
Wilson C Stevens A Mercer G Krishnan J
Full Access

Alignment and soft tissue balance are two of the most important factors that influence early and long term outcome of total knee arthroplasty.

Current clinical practice involves the use of plain radiographs for preoperative planning and conventional instrumentation for intra operative alignment.

The aim of this study is to assess the SignatureTM Personalised system using patient specific guides developed from MRI. The SignatureTM system is used with the VanguardRComplete Knee System. This system is compared with conventional instrumentation and computer assisted navigation with the Vanguard system.

Patients were randomised into 3 groups of 50 to either Conventional Instumented Knee, Computer Navigation Assisted Knee Arthroplasty or Signature Personalised Knee Arthoplasty. All patients had the Vanguard Total knee Arthroplasty Implanted.

All patients underwent Long leg X-rays and CT Scans to measure Alignment at pre-op and 6 months post-op. All patients had clinical review and the Knee Society Score (KSS) at 1 year post surgery was used to measure the outcome.

A complete dataset was obtained for 124 patients. There were significant differences in alignment on Long leg films ot of CT scan with perth protocol. Notably the Signature group had the smallest spread of outliers.

In conclusion the Signature knee system compares well in comparison with traditional instrumentation and CAS Total Knee Arthroplasty.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 14 - 14
1 Jan 2016
Grosser D Mercer G Wilson C Nilsson K Krishnan J
Full Access

Background

Safety and efficacy of novel prostheses relies on the determination of early implant migration and subsequent risk of loosening. Radiostereometric Analysis (RSA) has been used to evaluate the clinical failure risks of femoral stems by reporting distal migration, a measure of stem subsidence, when examining early migration characteristics. The migratory patterns of femoral stems, 24 months postoperatively, have provided a surrogate outcome measure to determine implant stabilisation and predict long-term performance and survivorship. RSA assessed femoral stem migration and provided comparison of the early migration characteristics with published data of a clinically established counterpart.

Methods

Twenty five patients undergoing primary total hip arthroplasty were implanted with a hydroxyapatite-coated femoral stem. The median age was 65 years (range, 43–75 years). During surgery tantalum markers were attached onto the distal tip and shoulder of the stem. Eight tantalum markers were inserted into the femur, four placed in each of the greater and lesser trochanter. RSA examinations were performed postoperatively at 4 to 5 days, 6, 12 and 24 months. Eleven patients who had complete RSA follow-up as well as the valid data from five patients were analysed to determine the movement of the femoral stem relative to the femur and were compared to the published data of a clinically established counterpart.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 25 - 25
1 Jan 2016
Stevens A Wilson C Shunmugam M Ranawat V Krishnan J
Full Access

Inter- and intra-observer variation has been noted in the analysis of radiographic examinations with regard to experience of surgeons, and the monitors used for conducting the evaluations. The aim of this study is to evaluate inter/intra observer variation in the measurement of mechanical alignment from long-leg radiographs.

40 patients from the elective waiting list for TKA underwent long leg radiographs pre-operatively and 6 months post-operatively (total of 80 radiographs). The x-rays were analysed by 5 observers ranging in experience from medical student to head orthopaedic surgeon. Two observers re-analysed their results 6 months later to determine intraobserver correlation, and one observer re-measured the alignment on a different monitor. These measurements were all conducted blindly and none of the observers had access to the others’ results.

80 radiographs were analysed in total, 40 pre-op and 40 post-op. The mechanical alignment was analysed using Pearson's correlation (r = 0 no agreement, r = 1 perfect agreement) and revealed that experience as an orthopaedic surgeon has little effect on the measurement of mechanical alignment from long leg radiograph. The results for the different monitor analysis were also analysed using Pearson's correlation of long leg alignment. Monitor quality does seem to affect the correlation between alignment measurements when reviewing both intra and inter observer correlation on different computer monitors.

Surgical experience has little impact on the measurement of alignment on long leg radiographs. Of greater concern is that monitors of different resolution can affect measurement of mechanical alignment. As there might be a range of monitors in use in different institutions, and also in outpatient clinics to surgical theatres, close attention should be paid to the implications of these results.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 1 - 1
1 Jun 2015
Bailey L Biggs P Wilson C Holt C Whatling G
Full Access

Risk factors for poor outcomes after total knee replacement (TKR) have been identified, but the underlying causes are not fully understood. The aim of this research was to establish the relationship between measurable gait parameters and patients' subjective function, pre and post total knee replacement. 25 subjects underwent gait analysis, before and one year following total knee replacement. Patient reported function was investigated using the Activities of Daily Living Scale of the Knee Outcome Survey (KOS). Gait analysis was performed using infrared cameras and reflective marker clusters. Correlation between motion analysis data and patient reported function was investigate. Whilst multiple gait parameters correlated with KOS score preoperatively, there was no correlation after TKR. Three preoperative measurements correlated with the improvement in score a subject achieved following surgery: These were preoperative rate of extension in swing, total range of flexion from heel strike and time point of maximum stance extension. Our results suggest that whilst preoperatively there is a close relationship between knee biomechanical function and patient reported function, after TKR factors other than biomechanical function determine patient outcomes.