header advert
Results 1 - 13 of 13
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 18 - 18
10 May 2024
Joseph R Callon K Lin J Matthews B Irwin S Williams D Ashton N Crawford H Wen J Swift S Cornish J
Full Access

Introduction

Major trauma during military conflicts involve heavily contaminated open fractures. Staphylococcus aureus (S. aureus) commonly causes infection within a protective biofilm. Lactoferrin (Lf), a natural milk glycoprotein, chelates iron and releases bacteria from biofilms, complimenting antibiotics. This research developed a periprosthetic biofilm infection model in rodents to test an Lf based lavage/sustained local release formulation embedded in Stimulin beads.

Method

Surgery was performed on adult rats and received systemic Flucloxacillin (Flu). The craniomedial tibia was exposed, drilled, then inoculated with S. aureus biofilm. A metal pin was placed within the medullary cavity and treatments conducted. Lf in lavage solutions: The defect was subject to 2× 50 mL lavage with 4 treatment groups (saline only, Lf only, Bactisure with Lf, Bactisure with saline). Lf embedded in Stimulin beads: 4 bead types were introduced (Stimulin only, Lf only, Flu only, Lf with Flu). At day 7, rats are processed for bioluminescent and X-ray imaging, and tibial explants/pins collected for bacterial enumeration (CFU).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 65 - 65
1 Aug 2020
Ekhtiari S Shah A Levesque J Williams D Yan J Thornley P
Full Access

Three-dimensional (3D) printing has become more frequently used in surgical specialties in recent years. Orthopaedic surgery is particularly well-suited to 3D printing applications, and thus has seen a variety of uses for this technology. These uses include pre-operative planning, patient-specific instrumentation (PSI), and patient-specific implant production. As with any new technology, it is important to assess the clinical impact, if any, of three-dimensional printing.

The purpose of this review was to answer the following questions:

What are the current clinical uses of 3D printing in orthopaedic surgery?

Does the use of 3D printing have an effect on peri-operative outcomes?

Four electronic databases (Embase, MEDLINE, PubMed, Web of Science) were searched for Articles discussing clinical applications of 3D printing in orthopaedics up to November 13, 2018. Titles, abstracts, and full texts were screened in duplicate and data was abstracted. Descriptive analysis was performed for all studies. A meta-analysis was performed among eligible studies to compare estimated blood loss (EBL), operative time, and fluoroscopy use between 3D printing cases and controls. Study quality was assessed using the Methodological Index for Non-Randomized Studies (MINORS) criteria for non-randomized studies and the Cochrane Risk of Bias Tool for randomized controlled trials (RCTs). This review was prospectively registered on PROSPERO (Registration ID: CRD42018099144).

One-hundred and eight studies were included, published between 2012 and 2018. A total of 2328 patients were included in these studies, and 1558 patients were treated using 3D printing technology. The mean age of patients, where reported, was 47 years old (range 3 to 90). Three-dimensional printing was most commonly reported in trauma (N = 41) and oncology (N = 22). Pre-operative planning was the most common use of 3D printing (N = 63), followed by final implants (N = 32) and PSI (N = 22). Titanium was the most commonly used 3D printing material (16 studies, 27.1%). A wide range of costs were reported for 3D printing applications, ranging from “less than $10” to $20,000. The mean MINORS score for non-randomized studies was 8.3/16 for non-comparative studies (N = 78), and 17.7/24 for non-randomized comparative studies (N = 19). Among RCTs, the most commonly identified sources of bias were for performance and detection biases. Three-dimensional printing resulted in a statistically significant decrease in mean operative time (−15.6 mins, p < .00001), mean EBL (−35.9 mL, p<.00001), and mean fluoroscopy shots (−3.5 shots, p < .00001) in 3D printing patients compared to controls.

The uses of 3D printing in orthopaedic surgery are growing rapidly, with its use being most common in trauma and oncology. Pre-operative planning is the most common use of 3D printing in orthopaedics. The use of 3D printing significantly reduces EBL, operative time, and fluoroscopy use compared to controls. Future research is needed to confirm and clarify the magnitude of these effects.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 30 - 30
1 Aug 2020
Ristevski B Gjorgjievski M Petrisor B Williams D Denkers M Rajaratnam K Johal H Al-Asiri J Chaudhry H Nauth A Hall J Whelan DB Ward S Atrey A Khoshbin A Leighton R Duffy P Schneider P Korley R Martin R Beals L Elgie C Ginsberg L Mehdian Y McKay P Simunovic N Ratcliffe J Sprague S Vicente M Scott T Hidy J Suthar P Harrison T Dillabough K Yee S Garibaldi A Bhandari M
Full Access

Distracted driving is now the number one cause of death among teenagers in the United States of America according to the National Highway Traffic Safety Administration. However, the risks and consequences of driving while distracted spans all ages, gender, and ethnicity. The Distractions on the Road: Injury eValuation in Surgery And FracturE Clinics (DRIVSAFE) Study aimed to examine the prevalence of distracted driving among patients attending hospital-based orthopaedic surgery fracture clinics. We further aimed to explore factors associated with distracted driving.

In a large, multi-center prospective observational study, we recruited 1378 adult patients with injuries treated across four clinics (Hamilton, Ontario, Toronto, Ontario, Calgary, Alberta, Halifax, Nova Scotia) across Canada. Eligible patients included those who held a valid driver's license and were able to communicate and understand written english. Patients were administered questions about distracted driving. Data were analyzed with descriptive statistics.

Patients average age was 45.8 years old (range 16 – 87), 54.3% male, and 44.6% female (1.1% not disclosed). Of 1361 patients, 1358 self-reported distracted driving (99.8%). Common sources of distractions included talking to passengers (98.7%), outer-vehicle distractions (95.5%), eating/drinking (90.4%), music listening/adjusting the radio (97.6%/93.8%), singing (83.2%), accepting phone calls (65.6%) and daydreaming (61.2%). Seventy-nine patients (6.3%), reported having been stopped by police for using a handheld device in the past. Among 113 drivers who disclosed the cause of their injury as a motor vehicle crash (MVC), 20 of them (17%) acknowledged being distracted at the time of the crash. Of the participants surveyed, 729 reported that during their lifetime they had been the driver in a MVC, with 226 (31.1%) acknowledging they were distracted at the time of the crash.

Approximately, 1 in 6 participants in this study had a MVC where they reported to be distracted. Despite the overwhelming knowledge that distracted driving is dangerous and the recognition by participants that it can be dangerous, a staggering amount of drivers engage in distracted driving on a fairly routine basis. This study demonstrates an ongoing need for research and driver education to reduce distracted driving and its devastating consequences.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 6 - 6
1 Mar 2014
Roberts N Bradley B Williams D
Full Access

Electronic PROMs have many potential uses in orthopaedic practice. The primary objective of this three-phase pilot study was to measure uptake using a web-based ePROM system following the introduction of two separate process improvements.

80 consecutive new elective orthopaedic patients in a single surgeon's practice were recruited. Group 1 (n=26) received a reminder letter, Group 2 (n=31) also received a SMS message via mobile or home telephone and Group 3 (n=23) also had access to Tablet Computer in clinic.

Overall 79% of patients had Internet access. 35% of Group 1, 55% of Group 2 and 74% of Group 3 recorded an ePROM score (p=0.02). There was no significant age difference between groups. In Group 3, 94% of patients listed for an operation completed an ePROM score (p=0.006).

Collecting PROM data effectively in everyday clinical practice is challenging. Electronic collection should improve healthcare delivery, but is in its infancy. This pilot study shows that the combination of SMS reminder and access to Tablet Computer within clinic setting enabled 94% of patients listed for an operation to complete a score on a clinical outcomes web-based system. Further process improvements, such as additional staff training and telephone call reminders, may further improve uptake.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 242 - 242
1 Dec 2013
Williams D Vinciguerra J Lerdahl J Bloebaum R
Full Access

Introduction:

Periprosthetic infections that accompany the use of total joint replacement devices cause unwanted and catastrophic outcomes for patients and clinicians. These infections become particularly problematic in the event that bacterial biofilms form on an implant surface. Previous reports have suggested that the addition of Vitamin E to ultra-high-molecular-weight polyethylene (UHMWPE) may prevent the adhesion of bacteria to its surface and thus reduce the risk of biofilm formation and subsequent infection.1–3 In this study, Vitamin E was blended with two types of UHMWPE material. It was hypothesized that the Vitamin E blended UHMWPE would resist the adhesion and formation of clinically relevant methicillin-resistant Staphylococcus aureus (MRSA) biofilms.

Methods and Materials:

Five sample types were manufactured, machined and sterilized (Table 1). To determine if MRSA biofilms would be reduced or prevented on the surface of the Vitamin E (VE) loaded samples (HXL VE 150 kGy and HXL VE 75 kGy) in comparison to the other three clinically relevant material types, each was tested for biofilm formation using a flow cell system.4

Direct Bacterial Quantification – An n = 7 samples of each material type were placed individually into a chamber of the flow cell. A solution of 10% modified brain heart infusion (BHI) broth containing 105 MRSA cells/mL was flowed through each chamber. Using previously established protocols,4–7 after 48 hours of growth, each sample was removed, and the number of colony forming units (CFU) determined using a 10-fold dilution series.

SEM Imaging – Using the same protocol as above, after the 48-hour incubation period, an n = 7 of each material type were fixed in 2.5% glutaraldehyde, dehydrated in ascending concentrations of ethanol, coated with carbon and imaged using scanning electron microscopy (SEM).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 5 - 5
1 Apr 2013
Daoud M Graham E Harding C Buecking B Williams D
Full Access

Treatment of trochanteric fractures is associated a high complication rate. This prospective multicenter study evaluates the new Zimmer Cephalomedullary Nail (CMN).

Patients over 50 years sustaining a pertrochanteric or subtrochanteric femoral fracture were prospectively enrolled and patients with multiple injuries, pathological fractures or severe dementia were excluded.

101 patients (70% female, 30% male) from 5 different hospitals were prospectively recruited between January 2011 and August 2012. Mean age was 78 (51–98) years and mean Charlson Score was 2.6 (1–6). 65% of the trochanteric fractures were unstable, 35% were stable. There were 4 (5%) minor (3 superficial infections and 1 pain over distal locking screw) and 3 (4%) major (2 lag screw cut out, 1 nail breakage) complications Fracture healing was completed in 27 of 31 patients (87%) after 12 month (3 month: 14/42 (33%); 6 month: 27/39(69%)). The Barthel Index (85, SD 19) and EQ-5-D (0.61, SD 0.30) values reached prefracture level after 6 month.

The study population and fracture type were comparable to other studies and complication and early union rates were also comparable. Technical complications were low and early functional results encouraging. Final results of this trial at one year follow up are awaited.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 35 - 35
1 Jan 2013
Williams D Price A Beard D Hadfield S Arden N Murray D Field R
Full Access

Objectives

This study examines variations in knee arthroplasty patient reported outcome measures according to patient age.

Methods

We analysed prospectively collected outcome data (OKS, Eq5D, satisfaction, and revision) on 2456 primary knee arthroplasty patients. Patients were stratified into defined age groups (< 55, 55–64, 65–74, 75–84, and ≥85 years). Oxford Knee Score and Eq5D were analysed pre-operatively, and postoperatively at 6 months and 2 years. Absolute scores and post-operative change in scores were calculated and compared between age groups. Satisfaction scores (0–100) were analysed at 6 months post-operatively. Linear, logistic and ordinal regression modelling was used to describe the association between age and outcomes, for continuous, binary and ordinal outcomes, respectively. Kaplan-Meier analysis was performed to describe revision rates at 2 years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 258 - 258
1 Sep 2012
Stammers J Williams D Berber O Abidin SZ Hunter J Leckenby J Vesely M Nielsen D
Full Access

Aims

The BOA/BAPRAS guidelines for the management of open tibial fractures (2009) recommend early senior combined orthoplastics input and appropriate facilities to manage a high caseload. St Georges Hospital is one of four London Trauma Centres fulfilling these criteria. Our aim is to determine whether becoming a trauma centre has affected the management of patients with open tibial fractures.

Methods

Data were obtained prospectively on consecutive open tibial fractures during two 8 month periods: before and after becoming a Major Trauma Centre (May 2009–Dec 2009 and April 2010–Oct 2010 respectively). Data on patient pathway including, admitting hospital, length of stay, timing and number of operations were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 58 - 58
1 May 2012
Hubble M Williams D Crawford R Timperley J Gie G
Full Access

Favourable long-term results have been reported with the standard Exeter cemented stem. We report our experience with a version for use in smaller femora, the Exeter 35.5 mm stem. Although, also a collarless polished taper, the stem is slimmer and 25 mm shorter than a standard stem.

Between August 1988 and August 2003, 192 primary hip arthroplasties were performed in 165 patients using the Exeter 35.5 mm stem. Clinical and operative data were collected prospectively. Clinical evaluation was by the Charnley, Harris and Oxford hip scores and radiographs were analysed post-operatively and at latest follow up.

The mean age at time of operation was 53 years (18 to 86), with 73 patients under the age of 50 years. The diagnosis was osteoarthritis in 91, hip dysplasia in 77, inflammatory arthritis in 18, septic arthritis of the hip in three, secondary to Perthes disease in two and avascular necrosis of the hip in one patient. The fate of every implant is known.

At a median follow-up of 8 years (5 to 19), survivorship with revision of the femoral stem for aseptic loosening as the endpoint was 100%. Fifteen cases (7.8%) underwent further surgery 11 for acetabular revision, one for stem fracture and three others.

Although, smaller than a standard Exeter Universal polished tapered cemented stem—with a shorter, slimmer taper—the performance of the Exeter 35.5 mm stem was equally good even in this young, diverse group of patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 219 - 219
1 May 2012
Hubble M Mounsey E Williams D Crawford R Howell J
Full Access

The cement in cement technique for revision total hip arthroplasty (THA) has shown good results in selected cases. However, results of its use in the revision of hemiarthroplasty to THA has not been previously reported.

Between May 1994 and May 2007 28 (20 Thompson's and 8 Exeter bipolar) hip hemiarthroplasties were revised to THA in 28 patients using the cement in cement technique. All had an Exeter stem inserted at the time of revision. Clinical and operative data were collected prospectively. Clinical evaluation was by the Charnley, Harris and Oxford. Hip scores and radiographs were analysed post-operatively and at latest follow up.

The mean age at time of hemiarthroplasty revision was 80 (35 to 93) years. The reason for revision was acetabular erosion in 12 (43%), recurrent dislocation in eight (29%), aseptic stem loosening in four (14%), periprosthetic fracture in two (7%) and infection in a further two (7%) patients. No patient has been lost to follow up. Three patients died within three months of surgery. The mean follow up of the remainder was 50 (16 to 119) months. Survivorship with revision of the femoral stem for aseptic loosening as the endpoint was 100%. Three cases (11%) have since undergone further revision, one for recurrent dislocation, one for infection, and one for periprosthetic fracture.

The cement in cement technique can be successfully applied to revision of hip hemiarthroplasty to THA. It has a number of advantages in this elderly population including minimising bone loss, blood loss and operative time.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIII | Pages 16 - 16
1 Apr 2012
Carlile GS Cowley A Thorpe B Williams D Spence R Regan M
Full Access

The time at which patients should drive following total hip replacement (THR) is dependant upon recovery and the advice they are given. The Driver Vehicle and Licensing Agency (DVLA) in the United Kingdom does not publish recommendations following THR and insurance companies usually rely on medical instruction. Few studies have been performed previously and have reached different conclusions.

Brake reaction times for patients undergoing primary THR were measured pre-operatively and at four, six and eight weeks after surgery using a vehicle driving simulator at a dedicated testing centre. Patients were prospectively recruited. Ethical approval was granted. Participants included eleven males and nine females, mean age 69 years. Side of surgery, frequency of driving and type of car (automatic or manual) were documented. Patients with postoperative complications were excluded. No adverse events occurred during the study.

Statistical analysis using Friedman's test demonstrated a statistically significant difference (P=0.015) in reaction times across the four time periods. Wilcoxon test demonstrated a highly significant difference between initial and six week mean results (P=0.003), and between four and six week results (P=0.001). No significant difference was found between six and eight weeks.

Our data suggests reaction times improve until week six and significantly between week four to six. Patients making an uncomplicated recovery following primary THR may be considered safe to return to driving from week six onwards. We recommend this is clearly documented in the medical notes, and patients should check with their insurance company prior to recommencement.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIII | Pages 18 - 18
1 Apr 2012
Rao M Arnaout F Williams D
Full Access

Knee dislocation is a rare injury in high energy trauma, but it is even rarer in low energy injuries. We present, to our knowledge, the only case in the world literature of knee dislocation following a cricketing injury. The patient was a 46 year old recreational fast bowler who, whilst bowling, slipped on the pitch on the follow through. He sustained an anteromedial knee dislocation which was reduced under intravenous sedation. He also sustained a neuropraxia of the common peroneal nerve with grade 2 weakness of ankle and toe dorsiflexion. Magnetic Resonance Imaging (MRI) confirmed a complete rupture of anterior cruciate ligament (ACL), lateral collateral ligament (LCL) and postero-lateral corner (PLC). Patient underwent surgical reconstruction and repair of his PLC along with repair of LCL with combination of anchor sutures and metal staple within 72 hours of the injury. He was treated in a cast brace. The ACL insufficiency was treated conservatively. Patient made an uneventful recovery and follow up at 3 months revealed a full range of knee movements with asymptomatic ACL laxity


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 109 - 109
1 Feb 2012
McCarthy M Aylott C Brodie A Annesley-Williams D Jones A Grevitt M Bishop M
Full Access

We aimed (1) to determine the factors which influence outcome after surgery for CES and (2) to study CES MRI measurements. 56 patients with evidence of a sphincteric disturbance who underwent urgent surgery (1994-2002) were identified and invited to clinic. 31 MRIs were available for analysis and randomised with 19 MRIs of patients undergoing discectomy for persistent radiculopathy. Observers estimated the percentage of spinal canal compromise and indicated whether they thought the scan findings could produce CES and whether the discs looked degenerate. Measurements were repeated after two weeks.

(1) 42 patients attended (mean follow up 60 months; range 25–114). Mean age at onset was 41 years (range 24–67). 26 patients were operated on within 48 hours of onset. Acute onset of sphincteric symptoms and the time to operation did not influence the outcomes. Leg weakness at onset persisted in a significant number at follow-up (p<0.005). Bowel disturbance at presentation was associated with sexual problems (<0.005) at follow-up. Urinary disturbance at presentation did not affect the outcomes. The 13 patients who failed their post-operative trial without catheter had worse outcomes. The SF36 scores at follow-up were reduced compared to age-matched norms in the population. The mean ODI was 29, LBOS 42 and VAS 4.5.

(2) No significant correlations were found between MRI canal compromise and clinical outcome. There was moderate to substantial agreement for intra- and inter-observer reproducibility.

Conclusions

Due to small numbers we cannot make the conclusion that delay to surgery influences outcome. Based on the SF36, LBOS and ODI scores, patients who have had CES do not return to a normal status. Using MRI alone, the correct identification of CES has sensitivity 68%, specificity 80% positive predictive value 84% and negative predictive value 60%. CES occurs in degenerate discs.