Perioperative antibiotic prophylaxis use in modern orthopaedic procedures is well established. Studies have shown significant reduction in risk of post-operative infections. However, as effectiveness of these antibiotics is dependent on achieving high serum and tissue concentrations that exceed the minimum inhibitory concentrations of infective organisms for operation duration, the timing of prophylaxis is crucial. Although, optimal timing for administering prophylaxis varies in the literature, 30 to 60 minutes prior to skin incision or inflation of tourniquet is considered best standards. To audit our practice of timing of administration of perioperative prophylactic antibiotics in trauma and orthopaedic procedures.Introduction
Objectives
Reverse total shoulder arthroplasty (RTSA) provides a surgical alternative to conventional shoulder arthroplasty in the rotator cuff deficient shoulder. Short term data has shown consistent improvements in pain and function but higher complication and failure rates have also been reported. The aims of this study were to identify the early and late complications of RTSA, to establish the frequency of glenoid notching, and to assess the post-operative functional outcomes. 21 patients (22 joints) treated with RTSA at Glasgow Royal Infirmary (GRI) between April 2006 and October 2010 were retrospectively reviewed. Indications for surgery included cuff tear arthropathy, revision hemiarthroplasty and fracture malunion. Complication rates were obtained by analysis of follow up data from Bluespier and case notes. Glenoid notching was graded from x-rays by multiple observers using the Sirveaux classification. Outcome was assessed using the Oxford Shoulder Score (OSS) and range of motion (ROM). The complication rate associated with RTSA was 14.3%, effecting 3 patients. One dislocation and 1 ulnar nerve palsy occurred within 30 days post-op. A late complication was represented by 1 dislocation, which required revision. Glenoid notching occurred in 71.4% (15 of 21patients), though the majority had a low Sirveaux classification (grade 1 or 2). OSS increased post-operatively and showed a linear improvement with time (R2 = 0.81) and ROM increased significantly post-op compared with pre-op (p<0.001). The complication rate associated with RTSA at GRI was lower than that reported in literature and the outcome was good as defined by ROM and OSS. The rate of glenoid notching was higher than literature reports but the significance of this is unclear as notching may not be associated with loosening.
The Medial Patellofemoral Ligament (MPFL) is the main restraining force against lateral patellar displacement. It is often disrupted following patellar subluxation or dislocation. MPFL reconstruction is frequently performed when conservative management fails and the patient experiences recurrent patellar dislocation. Various MPFL reconstruction procedures have been described in the literature and reported outcomes are encouraging. This study analyses the radiographic outcomes following MPFL reconstruction. From January 2006 to January 2011, 76 consecutive patients (80 knees) with patellar recurrent dislocation underwent medial patellofemoral ligament reconstruction in three large teaching hospitals. Mean follow-up was 31.8 months (range, 13–72). Semitendinosus and gracilis autografts were used for the reconstruction and all procedures were carried out by the senior authors (WL, BR, CW, MB). Plain radiographs (Anteroposterior (AP), Lateral and Skyline) performed preoperatively and postoperatively were used to compare the sulcus angle, congruence angle, lateral patellofemoral angle, trochlear dysplasia (Dejour classification), trochlear boss height and patellar height (Caton-Deschamps ratio). Plain radiographs (Lateral) performed postoperatively were used to evaluate the femoral tunnel placement used for MPFL reconstruction. The sulcus angle improved from 143.2° (122.9–157.7) to 139.3° (115.7–154.6) and the congruence angle improved from 26.7° (−17.5–82.6) to 0.26° (−35.3–7.8). The lateral patellofemoral angle was 7.99° (3.2–19.2) preoperatively and 9.02° (3.2–18.2) postoperatively. The Caton-Deschamps ratio was 1.2 (1.0–1.5) preoperatively and 1.0 (0.8–1.1) postoperatively. Using the Dejour classification of trochlear dysplasia, all preoperative radiographs were considered to be grade C or D and all postoperative radiographs were considered to be grade A or B. Trochlear boss height was 5.9mm (1.8–11.6) preoperatively and 4.7mm (1.6–6.9) postoperatively. 59% of the femoral tunnels were considered to be in a good position on postoperative radiographs. This study displayed a significant improvement in postoperative radiographic parameters, demonstrating the importance of anatomic restoration when performing MPFL reconstruction.
The aim of this study was to characterise noise associated with ceramic-on-ceramic total hip arthroplasty (THA). A questionnaire was constructed to assess noise associated with THA. 116 patients responded. All had ceramic-on-ceramic hybrid THA at Glasgow Royal Infirmary between 2005 and 2007 using a Trident prosthesis and Exeter stem. Oxford Hip Questionnaires (OHS) were also completed by the patients. 16.4% of respondents reported noise associated with their ceramic hip. The vast majority reported onset at least 1 year after implantation. The most common noise types were ‘clicking’ (47%) or ‘grinding’ (42%), while ‘squeaking’ was least frequently reported (11%). Noise was most commonly brought on by bending and during sit to stand movements. No correlation was identified between the incidence of noise and any patient specific factor or demographic variable. The mean OHS at questionnaire follow-up was 39 and there was no significant difference in OHS when comparing noisy and silent hips (p=0.65). Only 1 patient limited social or recreational activities and overall patients felt the noise had minimal effect on their quality of life. Acetabular component inclination angles were compared on post-operative x-rays. There was no significant difference (p=0.51) in inclination angles of the noisy (47.1°±6.3°, range 30–57°) and silent hips (47.8°±6.1°, range 35–68°). The groups were further analysed for deviation out with the desirable inclination range of 40–45°. Of the noisy hips, a total of 73% were out with this range compared to 63% in the silent hip group. The incidence of noise within this ceramic-on-ceramic THA group did not appear to be related to patient specific factors, patient reported outcome (OHS) or acetabular inclination angles. Subjective appraisal of the noise revealed that ‘squeaking’ was not common but patients tended to report ‘clicking’ and ‘grinding’ more. The precipitation of noise with bending activities reinforces a possible mechanical cause.
There is continued concern over complication rates (20–30% of cases) in locked proximal humeral plating. The most common sequelae of this is screw penetration of the humeral head. This is associated with natural settling of the fracture, malreducition in varus, insufficent medial support of the fracture. The proximity of the screws to the articular surface can also be influential on outcome if collapse occurs. Our operative technique is to establish the rotation of the humeral head where the drill appears closest to the articular margin (by sequential xray screening) and subtract from this to avoid intra-articular penetration of the humeral head. 55 Consecutive patients of average age 56.4 years (14.7–86.1), 17 male and 38 females, who underwent PHILOS plating were identified using Bluespier database. Xrays were analysed for fracture pattern, restoration of neck-shaft angle, plate positioning, number and configuration of screws and presence of screw penetration both intra-operatively and at postoperative follow-up. There were 6.07 screws used per head (total 330). There was one intraoperative screw penetration and 3 patients had evidence of screw penetration at follow-up, which required implant removal (total screw penetration rate of 7%). There was one case of AVN. The mean neck shaft angle was 137 degrees (anatomical 135 degrees). Accurate reduction of fractures and placement of screws in the humeral head using image intensifier can act to minimise risk of screw penetration and make some of the complications of locked proximal humeral plating avoidable.