Glenoid bone loss can be a challenging problem when revising
a shoulder arthroplasty. Precise pre-operative planning based on
plain radiographs or CT scans is essential. We have investigated
a new radiological classification system to describe the degree
of medialisation of the bony glenoid and that will indicate the
amount of bone potentially available for supporting a glenoid component.
It depends on the relationship between the most medial part of the
articular surface of the glenoid with the base of the coracoid process
and the spinoglenoid notch: it classifies the degree of bone loss
into three types. It also attempts to predict the type of glenoid reconstruction
that may be possible (impaction bone grafting, structural grafting
or simple non-augmented arthroplasty) and gives guidance about whether
a pre-operative CT scan is indicated. Inter-method reliability between plain radiographs and CT scans
was assessed retrospectively by three independent observers using
data from 39 randomly selected patients. Inter-observer reliability and test-retest reliability was tested
on the same cohort using Cohen's kappa statistics. Correlation of
the type of glenoid with the Constant score and its pain component
was analysed using the Kruskal-Wallis method on data from 128 patients.
Anatomical studies of the scapula were reviewed to explain the findings.Aims
Patients and Methods
Dislocation of the acromioclavicular joint is
a relatively common injury and a number of surgical interventions
have been described for its treatment. Recently, a synthetic ligament
device has become available and been successfully used, however,
like other non-native solutions, a compromise must be reached when
choosing non-anatomical locations for their placement. This cadaveric
study aimed to assess the effect of different clavicular anchorage points
for the Lockdown device on the reduction of acromioclavicular joint
dislocations, and suggest an optimal location. We also assessed
whether further stability is provided using a coracoacromial ligament
transfer (a modified Neviaser technique). The acromioclavicular
joint was exposed on seven fresh-frozen cadaveric shoulders. The
joint was reconstructed using the Lockdown implant using four different
clavicular anchorage points and reduction was measured. The coracoacromial
ligament was then transferred to the lateral end of the clavicle,
and the joint re-assessed. If the Lockdown ligament was secured
at the level of the conoid tubercle, the acromioclavicular joint
could be reduced anatomically in all cases. If placed medial or
2 cm lateral, the joint was irreducible. If the Lockdown was placed
1 cm lateral to the conoid tubercle, the joint could be reduced
with difficulty in four cases. Correct placement of the Lockdown
device is crucial to allow anatomical joint reduction. Even when the
Lockdown was placed over the conoid tubercle, anterior clavicle
displacement remained but this could be controlled using a coracoacromial
ligament transfer. Cite this article:
The LockDown device (previously called Surgilig)
is a braided polyester mesh which is mostly used to reconstruct the
dislocated acromioclavicular joint. More than 11 000 have been implanted
worldwide. Little is known about the tissue reaction to the device
nor to its wear products when implanted in an extra-articular site
in humans. This is of importance as an adverse immunological reaction
could result in osteolysis or damage to the local tissues, thereby affecting
the longevity of the implant. We analysed the histology of five LockDown implants retrieved
from five patients over the last seven years by one of the senior
authors. Routine analysis was carried out in all five cases and
immunohistochemistry in one. The LockDown device acts as a scaffold for connective tissue
which forms an investing fibrous pseudoligament. The immunological
response at the histological level seems favourable with a limited
histiocytic and giant cell response to micron-sized wear particles.
The connective tissue envelope around the implant is less organised
than a native ligament. Cite this article:
In the UK we have many surgeon inventors – surgeons who innovate and create new ways of doing things, who invent operations, who design new instruments to facilitate surgery or design new implants for using in patients. However truly successful surgeon inventors are a rare breed and they need to develop additional knowledge and skills during their career in order to push forward their devices and innovations. This article reviews my own experiences as a surgeon inventor and the highs and lows over the whole of my surgical career.
However the complication rates have been noticeably higher for the Inverse shoulder arthroplasties with 2/44 (5%) not being completed at surgery and 5/44 (11%) requiring surgical revision subsequently. This experience mirrors that of other publications which will be summarised.
Data were collected on patients undergoing subacromial decompression (SAD) in our routine practice from 1998 to 2004. All patients had clinical signs of subacromial pain and had failed conservative treatment. Tears were not repaired. Data on age, gender, arm dominance and presence of cuff tear at operation were recorded. At six months post-operatively, patients were assessed with the Constant Score (CS). Data were analysed using multiple linear regression. Data on 427 patients were collected, 168 having rotator cuff tears. The mean age was 55.41 years (SD 12.00). There were 233 women and 191 men. There were no significant gender differences between the two groups (x2=2.34, df=1, p=0.13). The group with cuff tears were significantly older by 10.24 years (p<
0.001, 8.10 to 12.38). Power of the study was 90% at the 5% significance level. Multiple linear regression showed that gender, age and presence of a cuff tear all had a significant effect on the CS. Gender B = 5.52 (1.99 to 9.06) p = 0.002 Age B = −0.31 (−0.48 to −0.15) p <
0.001 Cuff tear B = −5.51 (−9.48 to −1.55) p = 0.007 Hand dominance and the side operated upon had no significant effect. We found that in patients with symptomatic shoulders, who had failed conservative treatment and undergone an SAD, the CS at six months follow up was lower in those who had a cuff tear. There was increased tear prevalence in slightly older patients, and these scored on average 5.5 (1.5 to 9.5) points less than expected on the CS, p = 0.007, after allowing for age and gender. We believe that the surgeon should discuss with the patient whether a 5.5 points lower score is enough of a difference to warrant a formal rotator cuff repair rather than debridement and SAD alone, and a joint decision should be made.
The NHS Plan (2000) identified the need for change in the way patients are asked to give consent for surgery to make the process more explicit. A new NHS operation consent form was introduced in April 2002 following the Bristol enquiry into deaths associated with Cardiac Surgery.
Shoulder – Arthroscopic Sub-Acromial Decompression, Anterior stabilisation, Rotator Cuff repair, excision lateral end of clavicle and Shoulder Arthroplasty. Elbow – Tennis elbow release, Arthroscopic Debridement, OK Operation and Elbow Replacement We became increasingly aware throughout this exercise that although there were many papers published; collating the relevant evidence based information for patients was either difficult or impossible. Evidence was therefore been categorised into 4 levels:
National &
International published results Our own results, either published or presented at scientific meetings Our own results as identified in internal audited outcome studies – unpublished Our opinion of the risks or benefits unsupported by any scientific or published evidence.
We report the results of a method of reconstructing massive rotator cuff (RC) tears and reinforcing the repaired RC tendons with re-tensioning of the cuff to effect reconstruction of tears which were previously considered non-repairable.
We describe a surgical procedure used to achieve glenothoracic fusion after one-stage radical, near total scapulectomy for primary or secondary malignant lesions in six patients. The aim was complete excision of the lesion and preservation of the glenoid to provide a fulcrum for movement of the arm. Post-operative assessment involved determination of the range of movement and the application of the Musculoskeletal Tumour Society score and the Constant score to evaluate function. The results showed that a functional range of movement was attainable despite such radical surgery, although there was a considerable reduction in power and ability to lift.
This study investigates the survival (with gross radiological loosening) rates of prostheses following uncemented Total Shoulder Arthroplasties (TSAs) focusing on the glenoid baseplate fixation. All uncemented TSAs inserted in one shoulder unit from 1989 to 2001 were entered onto a database prospectively and the patients monitored to death or failure of the implant, resulting in revision surgery. Over 80% of the surviving implants were monitored on sequential radiographs and the radiological loosening rate was observed. 273 TSAs have been monitored – 193 with a porous coated glenoid baseplate and 80 with a hydroxyapatite coating on top of the porous coating. The Survival rates (%) of the non-HA coated base-plates at 1 to 12 years using the Life Table Method were:- 97, 93, 89, 83, 83, 81, 79, 79, 77, 75, 75 &
75% respectively. The Survival rates for the HA coated glenoid baseplates at 1 to 4 years were 100, 97, 93, &
93% respectively. Failures were predominantly due to mechanical loosening and glenoid disassembly with only 3 cases of infection documented. Thus by 4 years there was a statistically significant improvement in survival of the glenoids. Survival rates were further reduced when radiological loosening was taken into account. The earlier series was analysed to assess the survival of prostheses inserted for RA and OA. The survival rates at 5 &
10 years were 78% &
70% for OA and 96% &
88% for RA. This Life Table analysis confirms the early benefit from the use of hydroxyapatite coating of the glenoid implant of a TSA. Further improvements, particularly in relation to reducing further the small risk of disassembly are underway.
The ACL-deficient knee demonstrates an increase in both tibial rotation and translation that can lead to progressive degeneration within the knee joint. Functional Knee Braces (FKBs) have often been prescribed as an integral part of treatment programmes for such patients. However, the ability of a FKB to increase the stability of the ACL-deficient knee by controlling tibial translation has yet to be confirmed. In addition the athlete with ACL deficiency frequently asks if he/she can use a treadmill as a safe indoor exercise tool. A prospective study was carried out on 15 pre-operative ACL-deficient patients and 15 fully matched subjects as controls. A gait analysis study was designed using the CODA ACL-deficient subjects had significantly lower speed, shorter stride length and consequently longer double support time while walking on level ground (p<
0.05). None of these variables changed following bracing. The ACL-deficient subjects showed more knee flexion at heel strike and mid-stance which was assumed to be a compensatory reaction to the ligament deficient knee. The FKB significantly reduced ROM in the ACL-deficient subjects at all gait activity levels (p<
0.05). It also reduced peak knee flexion during swing while walking on level ground, but increased maximum knee flexion in swing while walking on the treadmill. Walking on the treadmill reduced hip ROM but running on the treadmill increased ankle ROM in both groups of subjects. No significant angulatory kinematic changes were found during running on the treadmill either before or after bracing. The ACL-deficient subjects showed more knee rotation than the controls during all the trials. Neither the quadriceps nor hamstring muscles showed significant differences between the ACL-deficient and control subjects. The gastrocnemius muscle however was found to have a principal role in the ACL-deficient subjects. FKBs caused the gastrocnemius to be activated earlier (P=0.0001) and showed a positive effect during low force activities. As treadmill walking or running was always accompanied by an increased ankle plantar flexion, it always decreased the gastrocnemius onset activation time that may be a compensatory reaction to stabilise the injured knee. No significant differences were found between the ACL-deficient and the control subjects in terms of kinematics or EMG findings during running on the treadmill. We have identified beneficial biomechanical changes following the use of FKBs on ACL-deficient knees but only during walking trials. The brace was as effective for walking on the treadmill as walking on the ground. The FKBs led the deficient knees into a safer kinematics and EMG pattern. The ACL-deficient subjects ran as normally as the control subjects and no effects of the FKBs were found during running in our studies.
The aimof this study was to assess proprioception in multi-directional instability of the shoulder before and after a new surgical treatment. A cross-sectional pilot study assessing shoulder proprioception in asymptomatic controls (n=6), pre-operative patients (n=7) awaiting surgery for atraumatic, multidirectional instability having failed a comprehensive rehabilitation programme and post-operative patients (n=7) having undergone thermo-capsular shrinkage of the shoulder and post-operative rehabilitation. Data were obtained using the Proprioception Assessment System developed at this centre following a standardised protocol to record both threshold to detection of passive movement (TTDPM) and reproduction of passive position (RPP) in three positions of rotation. Means and standard deviations are presented. There were no differences between shoulders in controls and post-operative patients. Despite the small numbers, pre-operative patients showed significant differences (p<
0.05) between shoulders in 2 of the 6 test protocols. Post-operative shoulders had means similar to controls suggesting thermo-capsular shrinkage may help regain shoulder proprioception after injury.
We have studied aseptic loosening of the femoral component in 76 patients with primary total hip replacement using the Capital prosthesis. The mean follow-up was 26 months (10 to 37). Twelve femoral components (16%) were definitely and eight (10%) were possibly loose. They were characterised by a thin cement mantle (p <
0.001) and excessive residual cancellous bone in the proximomedial region (p <
0.01). We recommend that the cement mantle around the prosthesis should be 2 to 3 mm and that further long-term studies are needed to evaluate the wear properties of titanium-nitride-coated titanium femoral heads.