Ensuring correct rotation of the femoral component
is a challenging aspect of patellofemoral replacement surgery. Rotation
equal to the epicondylar axis or marginally more external rotation
is acceptable. Internal rotation is associated with poor outcomes.
This paper comprises two studies evaluating the use of the medial
malleolus as a landmark to guide rotation. We used 100 lower-leg anteroposterior radiographs to evaluate
the reliability of the medial malleolus as a landmark. Assessment
was made of the angle between the tibial shaft and a line from the
intramedullary rod entry site to the medial malleolus. The femoral
cut was made in ten cadaver knees using the inferior tip of the
medial malleolus as a landmark for rotation. Rotation of the cut
relative to the anatomical epicondylar axis was assessed using CT.
The study of radiographs found the position of the medial malleolus
relative to the tibial axis is consistent. Using the inferior tip
of the medial malleolus in the cadaver study produced a mean external
rotation of 1.6° (0.1° to 3.7°) from the anatomical epicondylar
axis. Using the inferior tip of the medial malleolus to guide the
femoral cutting jig avoids internal rotation and introduces an acceptable
amount of external rotation of the femoral component.
A number of measurements of patella height exist all of which use a position on the tibia as a reference. The Patellotrochlear Index has recently been proposed as a more accurate reflection of the functional height of the patella and described in normal knees. We aimed to compare patellar height measurements in patients with patellofemoral dysplasia. In a retrospective analysis of the MRI scans of 33 knees in 29 patients with patellofemoral dysplasia we assessed the inter- and intraobserver reliability of four patellar height measurements: the Patellotrochlear Index (PTI), Insall-Salvati (IS), Blackburne-Peel (BP) and Caton-Deschamps (CD) ratios. We also assessed the correlation between the different measurements in predicting patella alta. Three blinded observers on two separate occasions performed the measurements. There were 21 females and 8 males with a mean age of 21.4 years (13–33). Statistical analysis revealed good inter-observer reliability for all measurements (0.78 for PTI, 0.78 for IS, 0.73 for BP and 0.77 for CD). Intra-observer reliability was also good (0.80, 0.83, 0.75, 0.78 respectively). When comparing the different measurements for patella alta there was a weak correlation between the PTI and the others. There was a strong correlation between the CD and BP ratios (0.96) and a moderate correlation between IS and CD and IS and BP ratios (0.594 and 0.539 respectively). All measurements are reproducible. The PTI however suggests patella alta exists in different patients to that suggested by the established measures. We propose the PTI as a more clinically relevant measure.
A number of measurements of patellar height are in clinical use all of which reference from the tibia. The patellotrochlear index has been proposed recently as a more accurate reflection of the functional height of the patella and described in normal knees. We compared patellar height measurements in patients with patellofemoral dysplasia. In a retrospective analysis of the MRI scans of 33 knees in 29 patients with patellofemoral dysplasia we assessed the inter- and intraobserver reliability of four patellar height measurements: the recently described Patellotrochlear Index (PTI), Insall-Salvati (IS), Blackburne-Peel (BP) and Caton-Deschamps (CD) ratios. We also assessed the correlation between the different measurements in predicting patella alta. Three blinded observers on two separate occasions performed the measurements. There were 21 females and 8 males with a mean age of 21.4 years (13–33). Statistical analysis revealed good inter-observer reliability for all measurements (0.78 for PTI, 0.78 for IS, 0.73 for BP and 0.77 for CD). Intra-observer reliability was also good (0.80, 0.83, 0.75, 0.78 respectively). There was weak correlation between the PTI and the other ratios for patella alta. There was a strong correlation between the CD and BP ratios (0.96) and a moderate correlation between IS and CD and IS and BP ratios (0.594 and 0.539 respectively). We propose the PTI as a more clinically relevant measure.
A number of measurements of patella height exist all of which use a position on the tibia as a reference. The Patellotrochlear Index has recently been proposed as a more accurate reflection of the functional height of the patella and described in normal knees.
Statistical analysis revealed good inter-observer reliability for all measurements (0.78 for PTI, 0.78 for IS, 0.73 for BP and 0.77 for CD). Intra-observer reliability was also good (0.80, 0.83, 0.75, 0.78 respectively). When comparing the different measurements for patella alta there was a weak correlation between the PTI and the others. There was a strong correlation between the CD and BP ratios (0.96) and a moderate correlation between IS and CD and IS and BP ratios (0.594 and 0.539 respectively).
This paper describes a simple new MRI measurement of the axial patellar tendon angle (APTA), and compares this angle in patients with and without patello-femoral instability.
In PFI, the patella is commonly tilted laterally. This is matched by the orientation of the patellar tendon. The increased tilt of the tendon is only partially corrected at its distal insertion with an abnormal angle of tibial attachment. When performing distal realignment procedures, angular correction as well as displacement may be appropriate.
This paper describes a simple new MRI measurement of the axial patellar tendon angle (APTA), and compares this angle in patients with and without patello-femoral instability.
In PFI, the patella is commonly tilted laterally. This is matched by the orientation of the patellar tendon. The increased tilt of the tendon is only partially normalized at its distal insertion with an abnormal angle of tibial attachment. When performing distal realignment procedures, angular correction as well as displacement may be appropriate.
Patello-femoral instability (PFI) and pain may be caused by anatomical abnormality. Many radiographic measurements have been used to describe the shape and position of the patella and femoral trochlea. This paper describes a simple new MRI measurement of the axial patellar tendon angle (APTA), and compares this angle in patients with and without patello-femoral instability.
In PFI, the patella is commonly tilted laterally. This is matched by the orientation of the patellar tendon. The increased tilt of the tendon is only partially normalized at its distal insertion with an abnormal angle of tibial attachment. When performing distal realignment procedures, angular correction as well as displacement may be appropriate.
During Anterior Cruciate Ligament reconstruction, using bone- patellar tendon- bone graft, debris can accumulate in the joint. We assessed incidence and potential for complications, described the radiographic appearance and defined the natural history of these intrarticular debris in 50 consecutive reconstructions. The records and radiographs of 50 consecutive cases were reviewed. A stripe of radio-opaque material, resembling a comma, termed the “comma” sign, was noted behind the lateral femoral condyle on the early postoperative radiographs of 40 of the 50 cases. There was no statistically significant difference in loss of knee motion at six, twelve, twenty- six and fifty- two weeks postoperatively (P>
0.50) between the patients presenting the radio-opacity and those without it. A second set of radiographs was taken in 12 patients between 3 and 18 months postoperatively, revealing that this radio- opaque material was visible in 1 case only. No correlation was found between presence of radio- opacities and duration of pain, effusion, analgesia requirement, discharge timing, time to driving and time to work. A protocol of postoperative early weight- bearing mobilisation had been followed in all cases which may have played a role in promoting the faster dissolution of the debris.
Cartilaginous and bony sulcus angles. Cartilage thickness in the sulcus and on both condyles. Morphology of the bony and cartilaginous surface contour (flat, convex or concave). Horizontal distance of the bony and cartilaginous sulcus measured from the lateral epicondyle. Inter and intra observer error was recorded.
The average bony sulcus angle (SA) was 166.9 degrees (141 – 203) whereas the average cartilaginous SA was 184.8 degrees (152 – 222). In 74 of 75 axial images (98.6%) the cartilaginous SA was greater than the bony SA by an average of 17.6 degrees (3 45). The average cartilage thickness in the centre of the trochlea was 3.5 mm (1.4 – 5.2), and the thickness on the lateral and medial condyles were 2.2mm (1.8 3.5) and 1.9mm (0.6 3.3) respectively. In 74 of 75 axial images (98.6%) the cartilaginous contour was different to the osseous contour on subjective assessment. In 58 of 75 images (77.3%) the cartilaginous contour changed the bony morphology from concave to flat or convex, or from flat to convex. In 17 (22.6%) it reduced the concavity. The average horizontal distance of the bony sulcus from the lateral epicondyle was 33.7mm (24 42) and that of the cartilaginous sulcus 31.8mm (23 39).