Computer-assisted navigation systems for total knee arthroplasty (TKA) were introduced to improve implantation accuracy and to optimize ligament balancing. Several comparative studies in the literature confirmed an effect on the component position and other studies could not confirm these results. For ligament balancing most studies found no significant influence on the clinical outcome using a navigation system for TKA. In the literature there were no reports of mid-term results after navigated TKA. With our study we wanted to show if the use of a navigation system for TKA will have an influence on the component's position and on the clinical results at 5-year follow up. We enrolled 200 patients in a prospective randomized study with a minimum follow up of 5 years. 100 TKA were operated on without using a navigation system (Group A) and 100 surgeries (Group B) were done with computer assistance. Radiological investigation by standard radiographs including a long-leg X-ray was performed with a follow up rate in Group A of 86.2% versus 80.2% in Group B. We measured the mechanical axis of the leg, lateral distal femoral angel (LDFA), medial proximal tibial angle (MPTA), tibial slope and the alpha-angle of the patella. Clinical investigation was performed with a follow up rate in Group A of 85.7% versus 79.8% in Group B including the parameters for the range of motion (ROM), ligament balancing, anterior drawer test, feeling of instability, anterior knee pain, effusion, WOMAC Score, Insall Score and HSS Knee Score.Background
Methods
A subvastus approach was used with a less than 10 cm incision. Femoral component alignment is established with an intramedullary, and the tibial component, with an extramedullary alignment guide. The navigation system was used for fine adjustment and verification of cutting block position. The navigation system used for the study was the VectorVision® CT-Free Knee 1.5.1.
A) Three wound drainages with an autotransfusion system and suction; B) no wound drainage; C) one intraarticular wound drainage without suction. Haemoglobin values, blood transfusion requirements, blood loss, postoperative range of motion, knee society score and rate of complications were observed and recorded. All patients were operated without tourniques for lower blood loss during total knee replacement.
Of 42 patients with resolvingscoliosis, 34 were followed up for more than 25 infantile idiopathicyears. Twenty had been primarily treated in a plaster bed and 14 by physiotherapy. The mean angle of the curve at presentation was 17° and at follow-up it was 5°. No patient had significant progression of the scoliosis during the growth spurt. When adults few had back pain or an increased disability score and there was no interference with work or social activities. The rib-vertebra angle difference proved to be an essential radiological sign when distinguishing resolving from progressive infantile idiopathic scoliosis. There was no advantage of plaster over physiotherapy with regard to either the time to resolution or the functional outcome. Treatment of resolving infantile idiopathic scoliosis in a plaster bed is therefore now outdated.