Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 667 - 674
1 May 2018
Lauthe O Soubeyrand M Babinet A Dumaine V Anract P Biau DJ

Aims

The primary aim of this study was to determine the morbidity of a tibial strut autograft and characterize the rate of bony union following its use.

Patients and Methods

We retrospectively assessed a series of 104 patients from a single centre who were treated with a tibial strut autograft of > 5 cm in length. A total of 30 had a segmental reconstruction with continuity of bone, 27 had a segmental reconstruction without continuity of bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity was defined as any event that required a modification of the postoperative management. Union was assessed clinically and radiologically at a median of 36 months (IQR, 14 to 74).


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 543 - 543
1 Nov 2011
Vincent-Mansour C Bernat A Soubeyrand M Molina V Gagey O Court C
Full Access

Purpose of the study: Kyphoplasty was introduced to reinforce the anterior column in osteoporotic vertebral fractures. It can be used for non-osteoporotic fractures. The purpose of this work was to report the clinical and radiographic results of kyphoplasty for non-ostoporotic vertebral fractures.

Material and methods: From December 2005 to August 2008, we followed prospectively 21 patients (12 M, 9 F) mean age 45 years (16–58) treated for thoracolumbar fractures by kyphoplasty in order to reinforce the anterior column. There were 23 fractures (T11 = 2, T12 = 5, L1 = 8, L2 = 4, L3 = 4) Magerl: A1 = 6, A3.1 = 7, A3.2 = 1, B1 = 2, B2 = 7. All patients were assessed preoperatively, postoperatively, and at last follow-up with a visual analogue scale (VAS) and the EIFEL function score. The sagittal CT scans passing through the pedicles and the midline were used to measure: the height of the anterior and posterior walls of the fractured vertebra and the supra and infra vertebrae as well as the kyphosis angle.

Results: Thirteen fractures were treated by kyphoplasty alone; seven by kyphoplasty combined with percutaneous osteosynthesis; three by kyphoplasty combined with open osteosynthesis with decompression because of preoperative neurological deficits. Mean follow-up was 13 months (6–28). There were no postoperative neurological or infectious complications. At last follow-up, the mean VAS was 1.25 (05) and the mean EIFEL 4 (0–12). Preoperatively, mean compression was 40.9% (6.2–81.4) for the anterior column and 16.7% (0–60.2) for the posterior column. Postoperatively the respective values were 22.8% (5.1–69.3) and 12.3% (−12 to 72.6) for a mean correction of 46.2% for the anterior column and 14.3% for the posterior column. At last follow-up, compression was respectively 26.1% and 7.9%. The vertebral kyphosis was 16.3 (6–16.3) preoperatively and 9.1 (3–4) postoperatively (mean correction 8.7). At last follow-up, vertebral kyphosis was 9.1 (1.7–28.3).

Discussion: Kyphoplasty allows satisfactory restoration of vertebral height without loosing short-term correction. For us, kyphoplasty should be associated with posterior fixation in patients with posterior injury. For neurological lesions, kyphoplasty associated with decompression and posterior fixation avoid the need for complementary anterior procedures.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 527 - 527
1 Nov 2011
Soubeyrand M Mahjoub S Vincent-Mansour C Gagey O Molina V Biau D Court C Michel J Ciritsis B
Full Access

Purpose of the study: Percutaneous screw fixation is widely used for the treatment of non-displaced fresh fractures of the carpal scaphoid. This screw fixation can be achieved either via a volar approach (retrograde insertion) or via a dorsal approach (antegrade insertion). The purpose of our study was to define the best approach as a function of the orientation of the fracture line (types B1 or B2 in the Herbert classification).

Material and methods: We used 12 upper limbs. For each wrist we obtained three scanner images: in maximal flexion, in the neutral position, and in maximal extension. For each scanner image, the parasagittal slice corresponding to the ideal plane for screw position was identified by digital reconstruction. On each slice, the type B1 and B2 fractures were modellised, as was the displacement of the corresponding screws introduced via the volar incision (S1) or the dorsal incision (S2). Each virtual screw was positioned as perpendicular as possible to the fracture line. For each slice corresponding to a given wrist position, we measured the angles between the fracture line (B1, B2) and the screws (S1, S2), giving four angles V1 (S1-B1), V2 (S1-B1), D1 (S2-B1), D2 (S2-B2). Thus the angle closest to 90° was considered the most satisfactory.

Results: For B2 fractures, the position of the virtual screw perpendicular to the fracture line was possible via both the volar and the dorsal incision. For B1 fractures, it was impossible to position the screw perpendicular to the fracture line, but the dorsal approach with the wrist in maximal flexion gave the best position.

Conclusion: For B2 fractures, the dorsal and volar approach allow optimal screw insertion so the choice of the incision depends on the surgeon’s experience. For B1 fractures, we recommend the dorsal approach.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 529 - 530
1 Nov 2011
Kalouche I Vincent-Mansour C Soubeyrand M Molina V Court C Gagey O
Full Access

Purpose of the study: Different posterior osteosynthesis techniques have been described for the treatment of unstable injury of the pelvic girdle. Bi-iliac fixation using threaded rods or plate-screw fixation has been proposed. The purpose of this work was to describe a modification of the posterior osteosynthesis using instrumentation designed for the spinal column.

Material and methods: From January 2006 to October 2008, four patients (three men, one woman, mean age 24 years, range 18–34) underwent surgery in our unit for unstable fractures of the pelvis with a trans-sacral posterior fracture line (AO classification C1.3–4). Two patients presented neurological signs including one by head trauma with hemiplegia. Two patients had an anterior fixation with an external fixator and another an anterior plate fixation. The operation was conducted via a posterior midline incision. After reduction of the fracture, the osteosynthesis was achieved with two poly-axial screws inserted in each of the iliac wings and connected by two rods and one or two cross connectors.

Results: Mean follow-up was 7.5 months (range 5–17). None of the patients developed infectious, neurological or mechanical complications postoperatively. Complete pain-free weight-bearing and walking were achieved in patients at three months. None of the patients had a horizontal or vertical misalignment callus measuring more than 5 mm. Screw analysis showed that three screws penetrated the sacroiliac joint in the first patient of the series with no clinical consequence.

Discussion: This posterior fixation technique for unstable fractures of the pelvis appears to be reliable and reproducible for type C fractures in combination with anterior fixation. It uses standard instrumentation for spinal osteosynthesis. A study with a larger population and longer follow-up is needed.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 497 - 497
1 Nov 2011
Soubeyrand M Vincent-Mansour C Guidon J Asselineau A Ducharnes G Court C Gagey O Molina V
Full Access

Purpose of the study: High-energy varus or valgus ankle trauma causes severe injury to the capsule and ligaments. We describe a presentation associating massive tears of the lateral/medial collateral ligaments with a transversal wound of the corresponding malleolus. This wound results from excessive tension on the skin cause by the major varus/valgus. We have defined this injury as an open and severe ankle sprain (OSAS).

Material and method: This was a retrospective analysis. We search the databases of three participating centres using the corresponding diagnostic and therapeutic codes from January 2005 to January 2009. The identified files were screened to select patients with OSAS.

Results: There were 11 cases of OSAS. Eight involved the lateral side of the ankle and three the medial side. Mean age was 41 years (range 21–45). All patients were victims of a high-energy trauma (five motorcycle accidents) and four patients had fallen from a high point. Associated injuries were tendon section (n=3), section of the deep fibular nerve (n=2), and section of the anterior tibial artery (n=1). Pneumarthrosis was the only visible anomaly on the plain x-rays of seven ankles. Diagnosis was confirmed preoperatively in all cases clinically with varus-valgus stress manoeuvres.

Conclusion: OSAS is a rare misleading injury. Confusion with a common wound is possible. The risk is to miss acute instability and thus its treatment. The diagnosis should be proposed for all transversal wounds without contusion over the malleolus with normal x-rays.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1389 - 1394
1 Oct 2011
Soubeyrand M Ciais G Wassermann V Kalouche I Biau D Dumontier C Gagey O

Disruption of the interosseous membrane is easily missed in patients with Essex-Lopresti syndrome. None of the imaging techniques available for diagnosing disruption of the interosseous membrane are completely dependable.

We undertook an investigation to identify whether a simple intra-operative test could be used to diagnose disruption of the interosseous membrane during surgery for fracture of the radial head and to see if the test was reproducible.

We studied 20 cadaveric forearms after excision of the radial head, ten with and ten without disruption of the interosseous membrane. On each forearm, we performed the radius joystick test: moderate lateral traction was applied to the radial neck with the forearm in maximal pronation, to look for lateral displacement of the proximal radius indicating that the interosseous membrane had been disrupted. Each of six surgeons (three junior and three senior) performed the test on two consecutive days.

Intra-observer agreement was 77% (95% confidence interval (CI) 67 to 85) and interobserver agreement was 97% (95% CI 92 to 100). Sensitivity was 100% (95% CI 97 to 100), specificity 88% (95% CI 81 to 93), positive predictive value 90% (95% CI 83 to 94), and negative predictive value 100%).

This cadaveric study suggests that the radius joystick test may be useful for detecting disruption of the interosseous membrane in patients undergoing open surgery for fracture of the radial head and is reproducible. A confirmatory study in vivo is now required.