Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure. All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR.Aims
Methods
This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales. Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence.Introduction
Methods
Traditional treatment for end-stage ankle arthritis has been ankle arthrodesis, however ankle arthroplasty is becoming an accepted alternative. The Zenith Ankle (Corin, UK) is 3rd generation implant with a mobile bearing design. In the NJR 2016 report, the Zenith was the commonest ankle prosthesis implanted in the UK. However, compared to other ankle implants, there's little published data on its performance and survival. The aim of this study was to analyse outcome in a consecutive series from a non-designer centre. We conducted a retrospective review of a consecutive series of 118 Zenith Ankle replacements implanted in our Unit (December 2010 to May 2016). Data was collected from our National Joint Registry entries, research databases, patient notes, PACS and PROMS.Introduction
Method
The aim of this study was to identify the rate of complications of total ankle replacement in a single Centre to help with informed patient consent. Between 2008 and 2012, 202 total ankle replacements (TARs) were performed by 4 surgeons at our Institute. Data was collected on all patients; demographics, arthritic disease, pre-operative deformity, prosthesis and all early and late complications.Introduction:
Methods:
A consecutive series of 23 patients (25 ankles) with osteoarthritis of the ankle and severe varus or valgus deformity were treated by open arthrodesis using compression screws. Primary union was achieved in 24 ankles one required further surgery to obtain a solid fusion. The high level of satisfaction in this group of patients reinforces the view that open arthrodesis, as opposed to ankle replacement or arthroscopic arthrodesis, continues to be the treatment of choice when there is severe varus or valgus deformity associated with the arthritis.