header advert
Results 1 - 7 of 7
Results per page:
Applied filters
Research

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 60 - 60
1 Aug 2013
Leung A Smith I Spadaccino A Muir A Simpson A
Full Access

Bone cutting produces heat which macroscopically leads to charring and the formation of bone dust. As part of a project to design a novel bone cutting device, we studied the extent of histological thermal damage from bone cutting with different cutting blades.

Three blades were used: a bone hacksaw made in the nineteenth century which was used for amputation, a sagittal saw blade made by Ortho Solutions, and a sagittal saw blade made by Stryker. Sheep femurs were harvested from recently euthanised animals and cuts were made with these three devices, producing ring-shaped bone specimens. Specimens were immediately stored in formaldehyde, decalcified, and stained with hematoxylin and eosin. The edge of the specimens was then photographed microscopically, and the images examined with the computer programme Axiovision (Carl Zeiss AG, Oberkochen, Germany). Visual examination allowed identification of live and dead osteocytes, and also to measure their depth from the surface.

A minimal of 7 images was obtained per blade. The hacksaw specimens had the highest percentage of live osteocytes (n=214, 59.8%), and with the shortest average depth where live osteocytes were located (169μm, SD 78.15). In comparison, the percentage of live osteocytes for the Ortho Solutions (n=156, 17.4%) and Stryker (n=168, 29.5%) blades were much lower. The difference in average depths where live osteocytes were located was statistically significant between the three groups (p < 0.001). The average depths of dead osteocytes were shallowest for the Stryker (115μm, SD 67.56) and hacksaw (118.28 μm, SD 75.16) groups with no statistical difference between them.

In conclusion the hacksaw appeared to produce the least thermal damage histologically during cutting. The results reflect a relationship between certain features in cutting blade designs and the extent of thermal damage. Future experiments to directly measure heat produced during cutting are planned.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 56 - 56
1 Mar 2013
Leung A Smith I Spadaccino A Muir A Simpson A
Full Access

Bone cutting produces heat which macroscopically leads to charring and the formation of bone dust. As part of a project to design a novel bone-cutting device, we studied the extent of histological thermal damage from different cutting blades. Three blades were used: a nineteenth century bone hacksaw, and modern sagittal saw blades manufactured by Ortho Solutions and Stryker. Sheep femurs were harvested from recently euthanised animals and cuts were made with these blades. Specimens were immediately stored in formaldehyde, decalcified, and stained with hematoxylin and eosin. The edge of the specimens was then photographed microscopically, and the images examined with Axiovision software (Carl Zeiss AG, Oberkochen, Germany). Visual examination allowed identification of live and dead osteocytes, and also to measure their depth from the surface. A minimal of 7 images was obtained per blade. The hacksaw specimens had the highest percentage of live osteocytes (n=214, 59.8%), and the shortest average depth where live osteocytes were located (169 μm, SD 78.15). In comparison, the percentage of live osteocytes for the Ortho Solutions (n=156, 17.4%) and Stryker (n=168, 29.5%) blades were much lower. The difference in average depths where live osteocytes were located was statistically significant between the three groups (p<0.001). In conclusion the hacksaw appeared to produce the least thermal damage histologically during cutting. The results reflect a relationship between certain features in cutting blade designs and the extent of thermal damage. Future experiments to monitor heat produced during cutting are planned.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 37 - 37
1 Mar 2013
Smith I Milto K Doherty C Amyes S Simpson A Hall A
Full Access

Staphylococcus aureus is a highly virulent pathogen and implicated in approximately 50% of cases of septic arthritis. Studies investigating other S. aureus-related infections suggest that alpha-(Hla), beta-(Hlb) and gamma-(Hlg) toxins are key virulence factors, with the ‘pore-forming’ alpha-toxin considered the most potent. Here, we have assessed the influence of alpha-toxin alone on in situ chondrocyte viability. Osteochondral explants were harvested from the metacarpophalangeal joints of 3-year-old cows and cultured in Dulbecco's Modified Eagle's Medium. The flasks were then inoculated with isogenic ‘knockout’ strains of S. aureus: DU5946 (Hla+Hlb-Hlg-: alpha-toxin only strain) or DU1090 (Hla-Hlb+Hlg+: beta- and gamma-toxin only strain). Explants were incubated (37°C) and stained after 18, 24 and 40hrs with chloromethylfluorescein-di-acetate and propidium iodide, labelling living chondrocytes green and dead cells red, respectively. Axial sections were imaged by confocal microscopy and the percentage cell death determined. Alpha-toxin-producing S. aureus caused 24.8+/−3.7% chondrocyte death at 18hrs and 44.6+/−7.2% death at 24hrs. At 40hrs, there was significantly more chondrocyte death (87.4+/−3.6%;p<0.001) compared to the alpha-toxin knockout strain, which was negligible (4.1+/−1.7%; means+/−SEM; N=4 independent experiments). In this in vitro bovine cartilage explant model, whereby the effects of defined toxins were determined in isolation of a complex host immune response, in situ chondrocyte viability was dramatically and exclusively reduced by alpha-toxin. This work forms the basis for developing a rational treatment to reduce the extent of cartilage destruction during an episode of septic arthritis. IDMS was supported by Orthopaedic Research UK and The Royal College of Surgeons of Edinburgh.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 28 - 28
1 Mar 2013
Smith I Winstanley J Doherty C Amyes S Simpson A Hall A
Full Access

We have demonstrated that toxins produced by Staphylococcus aureus, a common infective agent in septic arthritis (SA), cause rapid in situ chondrocyte death. Here, we have compared the sensitivity of chondrocytes within the superficial and deep zones (SZ, DZ) of cartilage to the same toxins. Culture medium containing the toxins produced by S. aureus strain 8325-4, which include alpha-, beta-, and gamma-toxin, was prepared. Cartilage explants free of subchondral bone were taken from the metacarpophalangeal joints of 3-year-old cows, and incubated (37°C) with the toxins. Explants were stained after 6hrs with chloromethylfluorescein-di-acetate and propidium iodide, labelling living chondrocytes green and dead cells red, respectively. Full-thickness coronal sections were imaged by confocal microscopy and the percentage cell death within the SZ (100μm from articular surface) and DZ (100μm from subchondral bone interface) determined. Both zones were incubated with the same toxin culture medium for the same time period. At 0hrs, chondrocytes within all zones were >98% viable. However, after incubation with toxin-containing culture medium for 6hrs, 71.9+/−11.2% of the SZ cells were dead compared to only 47.4+/−6.7% in the DZ (p=0.03;data are means+/−SEM;N=4). These results suggest that SZ chondrocytes are considerably more sensitive to S. aureus toxins than those within deeper zones. As SZ chondrocytes are close to the synovial fluid harbouring bacterial toxins, these data emphasise the need to remove bacteria and their products aggressively as part of the treatment of SA. IDMS was supported by Orthopaedic Research UK and The Royal College of Surgeons of Edinburgh.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 49 - 49
1 Mar 2013
Lin Y Hall A Smith I Salter D Simpson H
Full Access

The cartilage diseases such as osteoarthritis and chondral injuries are considered irreversible and the result of recent treatments remains not optimal. One of the reasons is due to the poor understanding of chondrocyte behaviours. To understand more about cartilage, we designed a series of novel experiments. First, a total joint of bovine metatarsophalanges was isolated as our novel model. We chose it because the configuration and the healing potential were similar to human, and many variables of large animal studies could be controlled in laboratory. The model not only provided a good ex vivo platform for cartilage researches but also connected in vitro cellular studies and in vivo animal studies. To mimic joint movement a special driving machine was designed. To characterise the novel model viabilities of chondrocytes and contents of sulphated glycosaminoglycan (GAGs) in extracellular matrixes were measured every seven days. The preliminary results revealed the viabilities of chondrocytes remained above 80% alive in the middle zone after four-weeks culture. The GAGs contents decreased after this culturing period. The experiments still carry on going to compare the static and dynamic models which joint movement could be a determinative factor to the viability of chondrocytes. Cellular treatment is the recent mainstream for cartilage diseases. If advanced knowledge in chondrocyte behaviours could be obtained from this model, development of optimal treatment will be possible in the future.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 75 - 75
1 Aug 2012
Smith I Milto K Amyes S Simpson A Hall A
Full Access

Staphylococcus aureus is the most common bacterial isolate in septic arthritis. From studies on isolated cartilage cells, the ‘pore-forming’ alpha and gamma toxins are considered the most virulent factors. However, understanding the response of in situ chondrocytes is important in order to identify new treatments to reduce the extent of cartilage damage during, and following, episodes of septic arthritis. Animal models can give useful information; however the interpretation of data can be complex because of the strong immune response. Thus, to clarify the role of S. aureus toxins on in situ chondrocytes we have developed a bovine cartilage explant model.

Metacarpophalangeal joints, from 3-year-old cows, were opened under sterile conditions within 6hrs of slaughter and cartilage explants harvested. Explants were placed into flasks containing Dulbecco's Modified Eagle Medium (DMEM). Aspirates from a patient with septic arthritis of the hip, containing S. aureus, were compared to negative aspirates (no bacterial growth) from a patient with an inflamed knee joint (controls).

The explants were incubated at 37 degrees Celsius and stained after 18, 24 and 40hrs with the fluorescent probes chloromethylfluorescein di-acetate and propidium iodide (10 micromolar each) to label living chondrocytes green and dead cells red respectively. Following imaging of cartilage by confocal laser scanning microscopy, the percentage cell death at each time point was obtained using Volocity 4 software.

There was no detectable change in chondrocyte viability (<1% cell death) over 40hrs incubation with the negative aspirate. However, for the aspirate from a patient positive for S. aureus, there was a rapid increase in cell death between 18 and 24hrs (0.2 +/− 0.3% to 23 +/− 5% cell death respectively) and almost complete cell death at 40hrs (80 +/− 12%; data are means +/− s.d; n=4).

These results show that a strain of S. aureus capable of manifesting clinical disease exerts a potent effect on in situ chondrocytes. In the absence of an immune response, chondrocyte death was purely the result of the bacteria and their products. This bovine cartilage explant model could therefore be useful for studying the effects of S. aureus on chondrocyte behaviour and, ultimately, cartilage integrity.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 15 - 15
1 Apr 2012
Smith I Hall A Simpson A
Full Access

Few studies have investigated the direct effect of bacteria and their products on articular cartilage chondrocytes ex vivo. An ex vivo model that allows the analysis of chondrocytes in situ would therefore be an important and exciting area of future research. It was hypothesised that a bovine cartilage explant model of septic arthritis would be an ideal model for providing fundamental information on the basic cellular mechanisms of cartilage destruction and chondrocyte death induced by bacterial infection uncomplicated by the immune response.

A fresh metacarpophalangeal joint from an abattoir slaughtered 3-year-old cow was skinned, rinsed in water and opened under sterile conditions. The cartilage explants were harvested using surgical scalpels and placed into a total of three tissue culture bottles (2 explants per bottle) containing 10ml Dulbecco's Modified Eagle Medium (DMEM). 50ml of a knee aspirate from a patient with septic arthritis, containing Group B streptococci (GBS), was added to bottle 1, 50ml of a negative knee aspirate was added to bottle 2 and 50ml DMEM to bottle 3.

The explants were incubated at 37°C for 24 hours. They were then stained with the fluorescent probes Chloromethylfluorescein Di-acetate (CMFDA) and Propidium Iodide and analysed using a Confocal Scanning Laser Microscope. Cell counts to assess percentage cell death were performed using Velocity 4 software.

There was strikingly more cell death observed at 24 hours in the cartilage explant exposed to bacteria in comparison to the non-infected controls. The percentage chondrocyte death was 43% in the presence of GBS, 0.8% in the presence of the negative aspirate and 0.2% in the presence of the DMEM control.

Although this is a very preliminary pilot study, it demonstrates an extremely rapid effect on the cartilage. Future bovine explant studies of septic arthritis will therefore be feasible and achievable.