Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To

Abstract

Reverse shoulder arthroplasty (RSA) is being increasingly used for complex, displaced fractures of the proximal humerus. The main goal of the current study was to evaluate the functional and radiographic results after primary RSA of three or four-part fractures of the proximal humerus in elderly patients.

Between 2012 and 2020, 70 consecutive patients with a recent three- or four-part fracture of the proximal humerus were treated with an RSA. There were 41 women and 29 men, with a mean age of 76 years. The dominant arm was involved in 42 patients (60%). All surgeries were carried out within 21 days. Displaced three-part fracture sustained in 16 patients, 24 had fracture dislocation and 30 sustained a four-part fracture of the proximal humerus. Patients were followed up for a mean of 26 months.

The mean postoperative OSS at the end of the follow-up period was 32.4. The mean DASH score was 44.3. Tuberosity non-union occurred in 18 patients (12.6%), malunion in 7 patients (4.9%), heterotopic ossification in 4 patients (2.8%) and scapular notching in one patient. Anatomical reconstruction was achieved in 25 patients (17.5%), the influence of greater tuberosity healing on shoulder function could not be demonstrated. Heterotopic ossification seems to affect OSS and QDASH, we found statistically significant relation between HO and clinical outcomes. Patients with heterotopic ossification had significantly lower postoperative scores on DASH and OSS (P = .0527).

Despite expecting good functional outcome with low complication rate after RSA, the functional outcome was irrespective of healing of the tuberosities.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 10 - 10
1 Jan 2022
Sobti A Jaffry Z Raj S Yiu A Negida A Singh B Brennan P Imam M Collaborative O
Full Access

Abstract

Background

Healthcare workers have had to make rapid and drastic adjustments to their practice in response to the COVID-19 pandemic. This work describes the effect on their physical, mental, financial and family well-being and assesses the support provided by their institutions.

Methods

An online survey was distributed through medical organisations, social media platforms and collaborators to staff based in an operating theatre environment.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 20 - 20
1 Nov 2017
Singh B Prasad R Bawale R Pillai D Mohanlal P
Full Access

Introduction

Adhesive capsulitis is a common condition causing painful limitation of shoulder movements. Hydrodistension is one of the techniques, is well recognised and has shown good outcomes. However, the results of hydro distension release in secondary adhesive capsulitis are not clear.

Patients and Methods

This is a retrospective study on patients undergoing hydro distension release. Patients who had any surgical intervention were classed as secondary whilst the rest were included in the primary group. The hydro distension is a standard technique where in the senior author locates the gleno humeral joint using radio opaque dye, followed by injection of 20 mls 0.5% L-bupivacaine and 80 mg of Triamcinolone, this is followed by use of 60 mls saline to perform the hydro distension.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 16 - 16
1 Nov 2017
Singh B Bawale R Mohanlal P Prasad VR
Full Access

Aim

To see if minor upper limb surgery procedures like CTR, Trigger release, Joint injections are safe for a remote telephonic review by specialist nurse. This arrangement was to help maintain our current agreed departmental New to Follow up ratio of 1:1.56 and also to improve access to specialist clinics.

Methods

This was a prospective study. Patients undergoing minor procedures were informed about the remote follow up arrangements when placed on waiting list and on the day of surgery. Patients were assured access to clinic up to 3 months after procedure. A specialist nurse undertook a telephone consultation at 2 and 6 weeks using a proforma provided by the Consultant.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 18 - 18
1 Nov 2017
Singh B Bawale R Sinha S Gulihar A Tyler J
Full Access

Introduction

A recent meta-analysis published in the British Medical Journal suggested an increased risk of infection, but none of the studies were large enough to reach statistical significance. A prospective, randomised trial was designed at our institution to investigate the wound healing and complications related to surgery following fracture neck of femur in the elderly.

Objectives

The primary aim was to compare the wound problems and infection following two different methods of skin closure: Subcuticular monocryl suture to metal clips for closure of skin. The secondary aim was to look at the duration of surgery after both types of closure. We received ethical approval for this study. We screened and recruited all eligible patients admitted with acute hip fracture undergoing hemi-arthroplasty or dynamic hip screw.

We recruited 541 patients in the study over the period of 3.5 years at our institution.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_13 | Pages 1 - 1
1 Jun 2016
Prasad VR Fung M Borowsky K Tolat A Singh B
Full Access

We wished to assess the usefulness of Inspace balloon arthroplasty (IBA), in our Upper limb unit by regular patient reviews prospectively. This prospective study was started adhering to local approval process. Patients were identified in routine clinical practice by three upper limb consultants presenting with pain and disability and diagnosis of cuff tear was established clinically and on MRI. The patients were explained of ‘available’ treatment options and an information leaflet about balloon arthroplasty provided. Patients were seen in 4 weeks, in a dedicated clinic to find out their willingness to participate. Consultant shoulder surgeons carried out all Balloon arthroplasties and where the cuff was reparable or contraindications identified were excluded from study.

All the patients were reviewed by an independent clinician pre-operatively and post operatively using the assessment tools of Oxford Shoulder Scores (OSS), SF12 and VAS at 6 weeks, followed by 3, 6, 12 months and annually after.

We performed a total of 32 IBA procedures. At the latest follow-up we identified that 24 patients have completed 2 years post procedure. Of these patients 1 deceased after 6 months, 3 were lost to follow up one each at 6, 12 and 24 months. Three were revised to reverse TSA. The OSS reflects that the positive difference of 10 in the average scores (24 pre-operative versus 34 at 2 years) noted at one year follow up were maintained at 2 years. Similar observations made analysing at 12 months and 2 years scores for the VAS pain scores of 3 at 2 years compared to pre-operative score of 6 and so were improvements in both physical & mental components of SF12.

Our study observes that the IBA provides a sustainable pain relief and functional improvements over 2 years and may be a suitable alternative in physiologically compromised patients with irreparable RCT.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 20 - 20
1 Oct 2015
Mohanlal P Bawale R Samsani S Jain S Joshi A Singh B Prasad R Pillai D
Full Access

Introduction

The MHRA guidelines for metal on metal (MOM) suggest cobalt and chromium levels of more than 7ppb as potential for soft tissue reaction. However, in some patients soft tissue reaction is seen even in the presence of normal serum metal ions levels.

Methods

A prospective review of all patients who had metal-on-metal hip arthroplasty was done. Patients who had both serum metal ion levels and MARS MRI scan were included in this study.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 3 - 3
1 Oct 2015
Goyal A Pillai D Bawale R Singh B
Full Access

Introduction

One of the disadvantages of lateral decubitus position during arthroscopic rotator cuff repair is the difficulty to control arm rotation intraoperatively making it necessary to create additional portals for anchor placement or an additional scrubbed assistant to control arm rotation.

Methods & Technique

We describe the use of commercially available TRIMANO® support arm from Arthrex as an easy device for secure positioning during arthroscopic rotator cuff repair in lateral decubitus position. Though initially marketed to be used for shoulder arthroplasties performed in beach chair position, the senior author has used TRIMANO® to perform arthroscopic rotator cuff repair in lateral decubitus position. The device is easily connected to the operating table side rail while the affected side forearm of the patient is placed in a disposable sterile foam arm holder and attached to the TRIMANO® arm. The “Click and Move” system of the TRIMANO® allows freedom to move the arm in any direction and also provides traction to distract the joint if needed.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 36 - 36
1 Oct 2015
Goyal A Pillai D Bawale R Singh B
Full Access

Accurate implant size estimation for internal fixation of long bone fractures can reduce intra-operative errors, operative time and radiation exposure. With the advent of pre-packed sterile implants, the exponential increase in the number of internal fixation devices and the lack of standard templates for them on PACS systems, templating has become increasingly difficult. This often results in the opening up of wrong implants leading to increased costs both in terms of increased operative time and additional implants. We describe a technique to determine implant size preoperatively using sterile implant boxes. Post anaesthesia and positioning, the pre packed implant box of approximate size is placed over the limb across the fracture site. An X-ray is then taken using the C-arm. In case of a plate, the number of holes desired on either side of the fracture, the shape of the implant and planned placement of screws are seen. Different implant boxes with the contained implant are placed and once the most appropriate implant for the particular fracture is reached, the box is opened and implant is kept ready for insertion. This technique has been found to be accurate, easy, reproducible and effective for estimating the implant size thereby decreasing the chances of opening wrong implants and saving the intra operative time substantially.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 2 - 2
1 Oct 2015
Prasad V Singh B Borowsky K Tolat A Kurta I
Full Access

Aim

To determine the benefit of dissolvable Balloon Arthroplasy in managing patients with massive irreparable rotator cuff tears (RCT).

Methods

This is prospective pilot study carried out adhering to the local approval process. Patients having massive cuff tear with pain or functional limitation were seen by consultants and MRI confirmed the diagnosis. The patients were explained of ‘all available’ treatment options and information leaflet about the new procedure balloon arthroplasty, provided. Patients were seen after 4 weeks in a dedicated clinic to find out if they were willing to participate. Patients were seen by a physiotherapist pre and post-operatively at 6 weeks then at 3, 6 and 12months in addition to medical follow-ups, using VAS, Oxford Shoulder, Constant and SF36 scores. All procedures were carried out by consultant shoulder surgeons and where the cuff was reparable or contraindications identified were excluded.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_10 | Pages 18 - 18
1 Oct 2015
Bawale R Samsani SR Jain S Joshi A Ahmed S Singh B Mohanlal P Pillai D Prasad R
Full Access

Background

Revision surgery for a failed metal on metal (MoM) hip arthroplasty is often unpredictable and challenging due to associated massive soft tissue and bony lesions. We present the analysis and early outcomes of revision surgery in failed MoM hip arthroplasties at our institution.

Methods

We have retrospectively analysed the findings and outcomes of revision surgery in 61 failed MoM hip arthroplasties performed between 2009 and 2014. These patients were identified in the special MoM hip surveillance pathway. All these patients underwent clinical assessment and relevant investigations. Intra-operative and histopathological findings were analysed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 32 - 32
1 Apr 2013
Bawale R Singh B
Full Access

Introduction

The wrist arthroscopy has been performed since 1979. With the advances in technology and surgical expertise, wrist arthroscopy has become third commonest procedure after knee and shoulder joint. Wrist arthroscopy has become a gold standard for diagnosing TFCC pathologies and other intercarpal disorders. Our aim was to compare the clinical, MRI and arthroscopic findings while treating various wrist pathologies.

Materials/Method

In retrospective trial, 30 patients (19 male and 11 female) with clinical evidence of wrist lesions were evaluated with MRI followed by wrist arthroscopy. The mean age of the patients at the time of outpatient appointment was 44 years with an average waiting time of 6.6 months. Inclusion criteria: all patients undergoing wrist surgery. Exclusion criteria: septic arthritis, acute distal radius fractures. Kappa analysis was used to compare the three methods of wrist pathology assessment. The total 30 patients were assessed for clinical findings, MRI report and corresponding arthroscopic findings.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 8 - 8
1 Apr 2012
Singh B Kewill S Hales P
Full Access

The carpometacarpal joint of the thumb is one of the most common locations of degenerative arthritis. Surgical options include trapezio-metacarpal fusion, replacement or resection arthroplasty with or without interposition.

We report the medium term results of a Modified Thompson's suspensionplasty. The radial half of the APL tendon was looped around the FCR tendon to create the suspension. The remainder of the tendon is then used for interposition.

We carried out a retrospective review of 50 patients (67 hands) who underwent this procedure from January 1999 to December 2005. There were 41 female (52 hands) and 9 male (15 hands). The average age at the time of surgery was 62 years (range 41 years – 79 years). The average follow up was 5.33 years (1-9 yrs). 22 patients also had a concurrent second procedure to the same thumb and a further three had a third procedure.

The average PRWHE score was 25 (0 – 80) and the average DASH score was 40 (24 – 100)

There were eight complications which included four persistent radial sided wrist pain. Two of these underwent tenotomy of FCR, whilst two responded to conservative measures. Two patients had symptoms related to scapho-trapezoid arthritis, which responded to an injection. One patient had superficial infection which settled with oral antibiotics, whilst another patient had early chronic regional pain syndrome. Overall the satisfaction rate was 90% with 48 patients (96%) willing to undergo the same procedure again.

We conclude that the modified Thompson's suspensionplasty gives excellent medium term results.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 18 - 18
1 Apr 2012
Hosangadi N Shetty K Nicholl J Singh B
Full Access

Fractures of distal tibia are common and often present with dilemma of appropriate and safe management. The use of locking plates has changed the way these fractures have been managed as it avoids extensive soft tissue dissection and periosteal stripping

The aims of this study were to look at the results of stabilization and analyse the complications of fractures of distal tibia treated with Locked plates

We carried out a retrospective study of patients who underwent surgical treatment for distal tibial fractures using MIPO (Minimally invasive Percutaneous Osteosynthesis) technique. The data was gathered from theatre data base. We studied a period between Nov 2006 to May 2009. We collected patient demographics as well as the type of fractures, mechanism of injury, radiological union and associated complications. There were no open fractures in the study. The limb was splinted for two weeks after surgery in a back slab. The patients were followed up at 6 weeks, 3, 6, 9 and 12 months after surgery.

There were 45 patients in the study with 29 males & 16 females between ages of 20 – 87 (avg. 49 yrs). 24 patients sustained injury due to a fall, 12 were involved in RTA and the remaining 9 were sports related injuries. The mean time to surgery was 3.15 days (1 – 7) and surgery was carried either by the consultant or their direct supervision. The mean hospital stay was 7 days (2 – 35) and mean time to radiological evidence of callus was 9 weeks. All patients eventually returned to their preinjury employment. 76% showed radiological union at 6 months and 90% at 9 months.

There were 3 superficial wound infections, 2 deep infections whilst 2 needed bone grafting and 1 implant failure. 2 patients developed mild form of CRPS which resolved at 12 months. 11 patients had metal discomfort of which 9 had removal of hardware. All these patients had the tip snapped off.

MIPO with LCP is a reliable and reproducible technique in treatment of closed unstable fracture of distal tibia. Patients must be counselled about implant removal after fracture union. Avoid snapping the tip of the LCP.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 134 - 134
1 Mar 2012
Gogi N Perera A Vishwanath M Gella S Singh B
Full Access

Aim

To assess the influence of posterior slope on Knee flexion and function in Asian and Caucasian populations.

Material & methods

We have conducted a prospective comparative study of 109 Asian and Caucasian posterior tibial slopes. All data has been collected prospectively and includes personal data (height, weight, tibial measurements), ASA grading, knees scores and range of movement. Analysis was performed for the whole group and comparisons were made between the two sets of patients. Minimum follow-up was two years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 121 - 121
1 Feb 2012
Haidar S Charity R Bassi R Nicolai P Tillu A Singh B
Full Access

Knee warmth is a common clinical observation following total knee arthroplasty (TKA). This can cause concern that infection is present. The purpose of our study was to establish the pattern of knee skin temperature following uncomplicated TKA. It was a prospective study carried out between 2001 and 2004. A pocket digital surface thermometer was used.

A preliminary study established that the best site to measure knee skin temperature was superomedial to the patella and the best time was 12 noon. Patients with an increased risk of infection and those with a contralateral knee pathology or a previous surgery were excluded. Forty-eight patients fulfilled the inclusion criteria and consented to participate; the skin temperature of operated and contralateral knees was measured pre-operatively and daily during the first six weeks post-operatively. Measurements were also taken at 3, 6, 12 and 24 months following surgery. During the course of the study, patients developing complications of the operated knee or any pathology of the contralateral knee were excluded.

Thirty-two patients completed the main study. Following surgery, systemic and both knees temperatures increased. Whereas systemic and contralateral knee temperatures settled within one week, the operated knee temperature took a longer time. The difference in temperature between the two knees had a mean value of +2.9°C at 7 days. This mean value decreased to +1.6°C at 6 weeks, +1.3°C at 3 months, +0.9°C at 6 months +0.3°C at 12 months and +0.04°C at 24 months. Following uncomplicated TKA, the operated knee skin temperature increases compared to the contralateral knee. This increase peaks at day 3 and diminishes slowly over several months; however, it remains statistically significant up to 6 months.

These results correlate with the findings of previous studies that showed a prolonged elevation of inflammatory markers.