Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 12 - 12
1 Jul 2012
Pastides P Tokarczyk S Ismail L Sarraf K Ahearne D
Full Access

The main purpose of preoperative blood tests is to provide information to reduce the possible harm or increase the benefit to patients by altering their clinical management if necessary. This information may help clinicians assess the risk to the patient, predict postoperative complications and establish a baseline measurement for later reference.

National Institute of Clinical Excellence (NICE) has issued guidelines around the need for pre-operative blood tests related to the age of the patient, comorbidities and the complexity of the procedure they will undergo.

We decided to retrospectively review the pre-operative blood requests for patients under the age of 65 who were admitted at our institution over a 2 month period for open reduction and internal fixation of the ankle or tibial plateau and manipulation under anaesthesia of the lower limb. Patients were divided into 2 groups, under the age of 40 and between 40-65 years old. Patients under the age of 18 were excluded. These surgical procedures were classified as ‘intermediate complexity’.

Admission clerkings of our 63 patient cohort were reviewed to ascertain if any patients had a significant co-morbidity or past medical history. The pre operative blood tests requested for each patient were audited against the NICE recommendations.

None of the patients under the age of 40 had any significant comorbidites, whilst 8 patients above the age of 40 suffered with hypertension.

95% of patients had at least one blood test carried out. All patients over the age of 40 had at least one blood test. Tests requested included full blood count (91%), urea and electrolytes (91%), coagulation (66%), liver function tests (67%), group and save (69%), CRP (70%), ESR (2%), thyroid function tests (5%) and CK (2%). Only 5 patients (5%) followed the guidelines correctly.

The clinical value of testing healthy individuals before an operation is debatable. The possible benefits of routine preoperative investigations include identification of unsuspected conditions that may require treatment before surgery or a change in surgical or anaesthetic management. The American Society of Anaesthesiologists has stated that ‘routine preoperative tests (i.e. tests intended to discover a disease or disorder in an asymptomatic patient) do not make an important contribution to the process of perioperative assessment and management of the patient by the anaesthesiologist.’

The overzealous requesting of preoperative blood tests also has a financial burden upon individual institutions. Our study also showed that some blood tests, such as inflammatory markers and thyroid function tests, were inappropriately requested. Adherence to the NICE guidelines would have resulted in a significant financial saving.

This review has shown that adopting the NICE guidelines may result in a decrease in the amount of unnecessary blood tests patients undergo when they attend hospital for routine, minor or intermediate surgical procedures. If these guidelines were implemented for all surgical procedures, this would undoubtedly result in a significant financial saving for the institution and the NHS as a whole. At our institution we have implemented surgical and anaesthetic team awareness and education around these guidelines in a bid to reduce the use of unnecessary testing.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 8 - 8
1 Jul 2012
Sarraf K Abdul-Jabar H Wharton R Shah G Singer G
Full Access

Femoral component fracture is a rarely reported but devastating complication of total knee arthroplasty. It has occurred most frequently with Whiteside Ortholoc II replacements uncemented knee replacements. Presentation may be with acute pain, progressive pain or returning deformity. It occurs more commonly in the medial condyle of the femoral component. It is rarely seen in cemented replacements.

All currently available literature describing fractures of condylar replacements, both cemented and uncemented. Predisposing factors include varus deformity either pre or post operatively. The mechanism of failure is thought to be failure of the infiltration of bone into the replacement. This is often due to polyethylene wear or metallosis causing abnormal tissue reaction with or without osteolysis.

We present the case of a fractured Press Fit Condylar (PFC) cemented implant (DePuy, Johnson&Johnson, Raynham, Massachusettes, USA) affecting the medial condyle. To our knowledge this is only the third reported case of fracture in a PFC implant, and the first in a cemented PFC implant.

Our patient was a 64 year old male who presented with unresolving knee pain post total knee arthroplasty, caused by fatigue fracture of the medial condyle of the femoral component. This was identified as loosening on plain radiographs and replaced with a revision prosthesis with a good post operative result. Given our aging population and with the increase of joint arthroplasty, this case sheds light on a potentially under recognised and increasingly important cause of knee pain following arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 11 - 11
1 Jul 2012
Sarraf K Atherton D Sadri A Jayaweera A Gibbons C Jones I
Full Access

Full-thickness burns around the knee can involve the extensor mechanism. The gastrocnemius flap is well described for soft tissue reconstruction around the knee. We describe a method where a Whichita Fusion Nail¯ knee arthrodesis, combined with a medial gastrocnemius muscle flap was used to salvage the knee and preserve the lower leg following a full-thickness contact burn.

The gastrocnemius flap for wound coverage of an open knee joint was originally described in 1970 and remains the workhorse for soft tissue knee reconstruction. There are a number of local alternatives including the vastus lateralis, medialis and sartorius flap; and perforator flaps such as the medial sural artery perforator island flap and islanded posterior calf perforator flap, however many of these are unsuitable for larger defects.

Full-thickness burns around the knee can put the extensor mechanism at risk and subsequent rupture is a possible consequence. The gastrocnemius flap has been used to cover a medial knee defect with exposed joint cavity following a burn and also been used in post burn contracture release around the knee.

The primary indication for Wichita fusion nail is a failed total knee replacement. It allows intramedullary stabilization with compression at the arthrodesis site to stimulate bone union. With fusion rates reported up to 100% and low complication rates as compared to other methods of fusion, the technique has a useful role in limb salvage type procedures.

While use of the gastrocnemius flap in knee burns has been described before we believe this is the first time that this combination of techniques, namely knee arthrodesis with soft tissue reconstruction using a gastrocnemius flap, has been reported. Combining these procedures with a multidisciplinary approach provides a useful alternative leading to limb salvage and avoiding the need for an above knee amputation when extensor reconstruction is not possible.