Advertisement for orthosearch.org.uk
Results 1 - 20 of 32
Results per page:
Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims

Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.

Methods

A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 41 - 41
24 Nov 2023
Lilleøre JG Jørgensen A Knudsen M Hanberg P Öbrink-Hansen K Tøstesen S Søballe K Stilling M Bue M
Full Access

Background and aim

Implant-associated osteomyelitis is one of the most feared complications following orthopedic surgery. Although the risk is low it is crucial to achieve adequate antibiotic concentrations proximate to the implant for a sufficient amount of time to protect the implant surface and ensure tissue integration. The aim of this study was to assess steady-state piperacillin concentrations in the proximity of an orthopedic implant inserted in cancellous bone.

Method

Six female pigs received an intravenous bolus infusion of 4 g/0.5 g piperacillin/tazobactam over 30 min every 6 h. Steady state was assumed achieved in the third dosing interval (12–18 h). Microdialysis catheters were placed in a cannulated screw in the proximal tibial cancellous bone, in cancellous bone next to the screw, and in cancellous bone on the contralateral tibia. Dialysates were collected from time 12 to 18 h and plasma samples were collected as reference.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 148 - 148
4 Apr 2023
Jørgensen P Kaptein B Søballe K Jakobsen S Stilling M
Full Access

Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry.

16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient reported outcome measures were obtained at post-op and 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during a passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner- and neck movements were described as anteversion, inclination and rotation.

Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute changes in the resulting liner/neck angle (small articulation) was 28° (12–46) and liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median (range) liner anteversion from 7° (-12–23) postoperatively to 10° (-3–16) at 1-year follow-up and inclination from 42 (35–66) postoperatively to 59 (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p=0.01).

The polyethylene liner moves over time. One year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 647 - 656
1 Jun 2022
Knudsen MB Thillemann JK Jørgensen PB Jakobsen SS Daugaard H Søballe K Stilling M

Aims

BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems.

Methods

A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery.


Bone & Joint Research
Vol. 10, Issue 1 | Pages 60 - 67
1 Jan 2021
Bendtsen MAF Bue M Hanberg P Slater J Thomassen MB Hansen J Søballe K Öbrink-Hansen K Stilling M

Aims

Flucloxacillin is commonly administered intravenously for perioperative antimicrobial prophylaxis, while oral administration is typical for prophylaxis following smaller traumatic wounds. We assessed the time, for which the free flucloxacillin concentration was maintained above the minimum inhibitory concentration (fT > MIC) for methicillin-susceptible Staphylococcus aureus in soft and bone tissue, after intravenous and oral administration, using microdialysis in a porcine model.

Methods

A total of 16 pigs were randomly allocated to either intravenous (Group IV) or oral (Group PO) flucloxacillin 1 g every six hours during a 24-hour period. Microdialysis was used for sampling in cancellous and cortical bone, subcutaneous tissue, and the knee joint. In addition, plasma was sampled. The flucloxacillin fT > MIC was evaluated using a low MIC target (0.5 μg/ml) and a high MIC target (2.0 μg/ml).


Bone & Joint Research
Vol. 8, Issue 7 | Pages 313 - 322
1 Jul 2019
Hanberg P Lund A Søballe K Bue M

Objectives

Meropenem may be an important drug in the treatment of open tibial fractures and chronic osteomyelitis. Therefore, the objective of this study was to describe meropenem pharmacokinetics in plasma, subcutaneous adipose tissue (SCT), and cancellous bone using microdialysis in a porcine model.

Methods

Six female pigs were assigned to receive 1000 mg of meropenem intravenously over five minutes. Measurements of meropenem were obtained from plasma, SCT, and cancellous bone for eight hours thereafter. Microdialysis was applied for sampling in solid tissues. The meropenem concentrations were determined using ultra-high-performance liquid chromatography.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 69 - 69
1 Dec 2018
Bue M Hanberg P Tøttrup M Thomassen M Sorensen HB Thillemann TM Andersson TL Søballe K
Full Access

Aims

Vancomycin may be an important drug for intravenous perioperative antimicrobial prophylaxis in spine surgery. We assessed single-dose vancomycin intervertebral disc, vertebral cancellous bone, and subcutaneous adipose tissue concentrations using microdialysis in a pig model.

Methods

8 female pigs received 1,000 mg of vancomycin intravenously as a single dose over 100 minutes. Microdialysis probes were placed in the C3-C4 intervertebral disc, C3 vertebral cancellous bone, and subcutaneous adipose tissue, and vancomycin concentrations were obtained over 8 hours. Venous blood samples were obtained as reference.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 45 - 45
1 Dec 2018
Bue M Hanberg P Koch J Jensen LK Lundorff M Aalbæk B Jensen HE Søballe K Tøttrup M
Full Access

Aim

The increasing incidence of orthopaedic methicillin-resistant Staphylococcus aureus (MRSA) infections represents a significant therapeutic challenge. Being effective against MRSA, the role of vancomycin may become more important in the orthopaedic setting in the years to come. Nonetheless, vancomycin bone and soft tissue penetration during infection remains unclear. We assessed the effect of a traumatically induced, implant-associated acute osteomyelitis on vancomycin bone penetration in a porcine model.

Method

In eight pigs, implant-associated osteomyelitis was induced on day 0, using a Staphylococcus aureus strain. Following administration of 1,000 mg of vancomycin on day 5, vancomycin concentrations were obtained with microdialysis for eight hours in the implant bone cavity, in cancellous bone adjacent to the implant cavity, in subcutaneous adipose tissue (SCT) adjacent to the implant cavity, and in healthy cancellous bone and healthy SCT in the contralateral leg. Venous blood samples were also obtained. The extent of infection and inflammation was evaluated by post-mortem computed tomography scans, C-reactive protein serum levels and cultures of blood and swabs.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 64 - 64
1 Apr 2018
Jacobsen JS Hölmich P Thorborg K Bolvig L Jakobsen SS Søballe K Mechlenburg I
Full Access

Introduction

Intra-articular injury has been described as primary cause of pain in hip dysplasia. At this point it is unknown whether external muscle-tendon related pain coexists with intra-articular pathology.

The primary aim was to identify muscle-tendon related pain in 100 dysplasia patients. The secondary aim was to test if muscle-tendon related pain is linearly associated to self-reported hip disability and muscle strength in patient with hip dysplasia.

Materials and methods

One hundred patients (17 men) with a mean age of 29 years (SD 9) were included. Clinical entity approach was carried out to identify muscle-tendon related pain. Muscle strength was assessed with a handheld dynamometer and self-reported hip disability was recorded with the Copenhagen Hip and Groin Outcome Score (HAGOS).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 88 - 88
1 Jan 2018
Søballe K Troelsen A Andreasen C
Full Access

The goal of periacetabular osteotomy (PAO) is to delay or prevent osteoarthritic development in dysplastic hips. However, it is unclear whether the surgical goals are achieved and if so in which patients. This information is essential to select appropriate patients for a durable PAO that achieves its goals.

We therefore (1) determined hip survival rates; (2) determined how many preserved hips were functionally successful after PAO; and (3) identified demographic, clinical, and radiographic factors predicting failure after PAO.

We reviewed 316 patients (401 hips) who had PAO. We evaluated radiographic parameters and obtained WOMAC scores. Through inquiry to the National Registry of Patients, we identified conversions to THA. Risk factors for conversion to THA were assessed. Mean followup was 8 years (range, 4–12 years).

We conclude that PAO can be performed with a good outcome at medium to long term follow-up, suggesting that it may be applied by experienced surgeons with satisfactory results. To further improve the outcome, focus should be on the potential negative influence of parameters that are easily assessed, such as the patients age (>45) preoperative grade of osteoarthritis, incongruency, and severe acetabular dysplasia. Perioperatively, the surgeon should attempt to achieve hip congruence and a CE angle between 30° to 40° to improve the durability of PAO.

Level II, prognostic study.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 62 - 62
1 Dec 2017
Hanberg PE Bue M Sørensen HB Søballe K Tøttrup M
Full Access

Aim

Pyogenic spondylodiscitis is associated with prolonged antimicrobial therapy and high relapse rates. Nevertheless, tissue pharmacokinetic studies of relevant antimicrobials in both prophylactic and therapeutic situations are still sparse. Previous approaches based on bone biopsy and discectomy exhibit important methodological limitations. The objective of this study was therefore to assess the concentration of cefuroxime in intervertebral disc (IVD), vertebral body cancellous bone, subcutaneous adipose tissue (SCT) and plasma pharmacokinetics after single dose administration by use of microdialysis (MD) in a large animal model.

Method

Ten female pigs were assigned to receive 1,500 mg of cefuroxime intravenously over 15 min. Measurements of cefuroxime were obtained from plasma, SCT, the vertebral cancellous bone and the IVD for 8 hours thereafter. MD was applied for sampling in solid tissues. The cefuroxime concentration in both the MD and plasma samples was determined using ultra-high performance liquid chromatography.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 74 - 74
1 Dec 2017
Bue M Tøttrup M Hanberg P Langhoff O Sorensen HB Thillemann TM Andersson TL Søballe K
Full Access

Aim

The incidence of orthopaedic methicillin-resistant staphylococcus aureus infections is increasing. Vancomycin may therefore play an increasingly important role in orthopaedic perioperative antimicrobial prophylaxis. Adequate antimicrobial concentrations at target site is essential for prevention of orthopaedic infections. Current studies investigating perioperative bone and soft tissue concentrations of vancomycin are sparse and challenged by a lack of appropriate methods. The aim of this study was therefore to assess the concentration of vancomycin in plasma, subcutaneous tissue and bone after single dose administration using microdialysis (MD) in patients undergoing total knee replacement.

Method

1,000 mg of vancomycin was postoperatively administered intravenously over 100 minutes to 10 male patients undergoing primary total knee replacement. Vancomycin concentrations in plasma, subcutaneous tissue (SCT), cancellous and cortical bone were measured the following 8 hours. MD was applied for sampling in solid tissues. The vancomycin concentration in MD-samples was determined using ultra-high performance liquid chromatography, whilst the free plasma concentration was determined using a chemistry analyzer*.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 89 - 89
1 Dec 2017
Lange J Troelsen A Solgaard S Ørsnes T Otte K Nielsen PT Lamm M Krarup N Mikkelsen S Zawadski A Søballe K
Full Access

Aim

Our aim was to evaluate cementless one-stage revision in chronic periprosthetic hip joint infection.

Method and patients

The study was performed as a multicentre, proof-of-concept, observational study with prospective data collection. Inclusion of patients with a chronic periprosthetic hip joint infection (PJI) were followed by protocolled surgical treatment (cementless one-stage revision - the CORIHA protocol) at one of 8 participating departments of orthopaedic surgery between 2009 – 2014, and the patients enrolled in a 2-year follow-up program. A PJI were diagnosed based on adopted criteria from McPherson and Zimmerli. At the time of initiation of the study in 2009, the collaborating departments performed approximately one-fourth of all nationwide primary HJR and more than one-third of all revisions.

In total 56 PJI patients with a median age of 72 years and a median pre-operative ASA score of 2 met the established eligibility criteria and accepted to participate; 31 (55%) were males.

The cohort had a mean follow-up time of 4.0 years, with all patients followed for minimum 2 years.

The primary outcome were relapse described as re-revision due to infection (regardless of considered as a relapse or new infection). This was evaluated by competing risk analysis (competing risks: aseptic revisions and death).

Secondary, all-cause mortality was evaluated by survival analysis.

The study was approved by the local Committees on Biomedical Research Ethics.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 95 - 95
1 Dec 2017
Falstie-Jensen T Daugaard H Lange J Ovesen J Søballe K
Full Access

Background

Periprostetic joint infections (PJI) are often difficult to diagnose, to treat and often leave the patient with severe impaired function. The presence of low virulent bacteria is frequently discovered in apparent aseptic revisions of shoulder arthroplasties and pose a challenge to diagnose preoperatively.

Dual Isotope In111 Leucocyte/ Tc99 Bone Marrow SPECT CT scan (L/BMS) is considered the radionuclide gold standard in preoperative diagnosing PJI with reported high specificity and sensitivity in hip and knee arthroplasties.

Unfortunately, it is labour-intensive and expensive to perform and documentation using L/BMS on shoulder arthroplasties lack.

Aim

To investigate if L/BMS succeeds in detecting shoulder PJI compared to tissue cultures obtained perioperatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 77 - 77
1 Dec 2016
Tøttrup M Bue M Koch J Jensen LK Hanberg P Aalbæk B Fuursted K Jensen HE Søballe K
Full Access

Aim

A reason for treatment failure, in cases of periprosthetic bone infections and osteomyelitis, may be incomplete or heterogeneous tissue distribution of antimicrobials to the affected bone. Decreased bioavailability has been demonstrated in healthy bones but never in pathological bone tissue. Therefore, the aim was to obtain pharmacokinetic parameters of cefuroxime in infected bone tissue by means of microdialysis in a porcine model of implant associated osteomyelitis

Method

An implant cavity of 4 mm in diameter was drilled 25 mm into the right tibial bone of ten pigs (30 kg/BW). Subsequently, a small steel implant (K-wire 2 × 2 mm) and 104 CFU of Staphylococcus aureus was inserted and injected into the implant cavity. Five days after inoculation, two additional drill holes of 2 × 25 mm were drilled into the trabecular bone tissue adjacent to the implant cavity and into the left uninfected tibia. After intravenous administration of 1500 mg of cefuroxime, the concentration was measured in plasma and in the three tibial drill holes for 8 hours. All measurements were performed with microdialysis. Post mortem, the presence of bone infection was assessed by computed tomography (CT) scans and cultures of swabs.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1554 - 1562
1 Nov 2016
Martinkevich P Rahbek O Stilling M Pedersen LK Gottliebsen M Søballe K Møller-Madsen B

Aims

To compare the structural durability of hydroxyapatite-tricalcium phosphate (HATCP) to autologous iliac crest bone graft in calcaneal lengthening osteotomy (CLO) for pes planovalgus in childhood.

Patients and Methods

We present the interim results of ten patients (HATCP, n = 6 and autograft, n = 5) with a mean age of 11.5 years (8.2 to 14.2) from a randomised controlled non-inferiority trial with six months follow-up. The primary outcome was the stability of the osteotomy as measured by radiostereometric analysis. A non-inferiority margin of ≤ 2 mm osteotomy compression was set.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 7 - 7
1 Dec 2015
Lange J Pedersen A Troelsen A Søballe K
Full Access

There is an apparent need for easily accessible research data on Periprosthetic hip joint infections (PJI)(1). Administrative discharge registers could be a valuable single-sources for this purpose, and studies originating from such registers have been published(2–4). However, the quality of routinely collected data for administrative purposes may be questionable for use in epidemiological research. The aim of this study was to estimate the positive predictive value of the International Classification of Disease 10th revision (ICD-10) periprosthetic hip joint infection diagnose code T84.5.

The study was performed as a cross-sectional study on data extracted from the Danish National Patient Register. Patients with a registration of performed surgical treatment for hip PJI were identified via the ICD-10 code T84.5 (Infection and inflammatory reaction due to internal joint prosthesis) in association with hip-joint associated surgical procedure codes. Medical records of the identified patients (n=283) were verified for the existence of a periprosthetic hip joint infection. Positive predictive values with 95% confidence intervals (95% CI) were calculated.

A T84.5 diagnosis code irrespective of the associated surgical procedure code had a positive predictive value of 85 % (95% CI: 80–89). Stratified to T84.5 in combination with an infection-specific surgical procedure code the positive predictive value increased to 86% (95% CI: 80–91), and in combination with a noninfection-specific surgical procedure code decreased to 82% (95% CI: 72–89).

This study is the first to evaluate the only discharge diagnose code of prosthesis-related infection in an administrative discharge register. It is apparent, that codes in administrative discharge registers are prone to misclassification on an administrative level, either by wrongful coding by the physician or administrative personal in the registration process. Misclassification must be expected and taken into consideration when using single-source administrative discharge registers for epidemiological research on periprosthetic hip joint infection. We believe that the periprosthetic hip joint infection diagnose code can be of use in single-source register based studies, but preferably should be used in combination with alternate data sources to ensure higher validity(5)

This study is funded in part by the Lundbeck foundation Centre for Fast-track Hip and Knee Surgery, Denmark.


Bone & Joint Research
Vol. 4, Issue 5 | Pages 78 - 83
1 May 2015
Martinkevich P Rahbek O Møller-Madsen B Søballe K Stilling M

Objectives

Lengthening osteotomies of the calcaneus in children are in general grafted with bone from the iliac crest. Artificial bone grafts have been introduced, however, their structural and clinical durability has not been documented. Radiostereometric analysis (RSA) is a very accurate and precise method for measurements of rigid body movements including the evaluation of joint implant and fracture stability, however, RSA has not previously been used in clinical studies of calcaneal osteotomies. We assessed the precision of RSA as a measurement tool in a lateral calcaneal lengthening osteotomy (LCLO).

Methods

LCLO was performed in six fixed adult cadaver feet. Tantalum markers were inserted on each side of the osteotomy and in the cuboideum. Lengthening was done with a plexiglas wedge. A total of 24 radiological double examinations were obtained. Two feet were excluded due to loose and poorly dispersed markers. Precision was assessed as systematic bias and 95% repeatability limits.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 140 - 140
1 Jul 2014
Hjorth M Søballe K Jakobsen S Lorenzen N Mechlenburg I Stilling M
Full Access

Summary

Five year migration results of 49 large-head metal-metal (MoM) total hip arthroplasties show good implant stability and no association between implant migration and metal-ions levels, stem and cup position, or femoral bone mineral density.

Introduction

The failure mechanism of metal-metal (MoM) total hip arthroplasty has been related to metal wear-debris and pseudotumor, but it is unknown whether implant fixation is affected by metal wear-debris.


Bone & Joint Research
Vol. 1, Issue 8 | Pages 180 - 191
1 Aug 2012
Stilling M Kold S de Raedt S Andersen NT Rahbek O Søballe K

Objectives

The accuracy and precision of two new methods of model-based radiostereometric analysis (RSA) were hypothesised to be superior to a plain radiograph method in the assessment of polyethylene (PE) wear.

Methods

A phantom device was constructed to simulate three-dimensional (3D) PE wear. Images were obtained consecutively for each simulated wear position for each modality. Three commercially available packages were evaluated: model-based RSA using laser-scanned cup models (MB-RSA), model-based RSA using computer-generated elementary geometrical shape models (EGS-RSA), and PolyWare. Precision (95% repeatability limits) and accuracy (Root Mean Square Errors) for two-dimensional (2D) and 3D wear measurements were assessed.