Despite the availability of numerous tests, the diagnosis of periprosthetic infection (PJI) continues to be complex. Although several studies have suggested that coagulation-related markers, such as D-dimer and fibrinogen, may be promising tools in the diagnosis of prosthetic infections, their role is still controversial. The aim of this study is to evaluate the diagnostic accuracy of serum D-dimer and fibrinogen in patients with painful total knee replacement. 83 patients with painful total knee replacement and suspected peri-prosthetic infection were included. All patients underwent pre-operative blood tests to evaluate inflammation indices (ESR and CRP) and serum D-Dimer and Fibrinogen levels. The diagnostic performance of the tests was assessed using the ICM definition as the gold standard. The diagnostic accuracy of the D-dimer and fibrinogen was measured by assessing sensitivity, specificity and by calculating the area under the ROC curve.Aim
Method
Implant-related infection is one of the leading reasons for failure in orthopaedics and trauma, and results in high social and economic costs. Various antibacterial coating technologies have proven to be safe and effective both in preclinical and clinical studies, with post-surgical implant-related infections reduced by 90% in some cases, depending on the type of coating and experimental setup used. Economic assessment may enable the cost-to-benefit profile of any given antibacterial coating to be defined, based on the expected infection rate with and without the coating, the cost of the infection management, and the cost of the coating. After reviewing the latest evidence on the available antibacterial coatings, we quantified the impact caused by delaying their large-scale application. Considering only joint arthroplasties, our calculations indicated that for an antibacterial coating, with a final user’s cost price of €600 and able to reduce post-surgical infection by 80%, each year of delay to its large-scale application would cause an estimated 35 200 new cases of post-surgical infection in Europe, equating to additional hospital costs of approximately €440 million per year. An adequate reimbursement policy for antibacterial coatings may benefit patients, healthcare systems, and related research, as could faster and more affordable regulatory pathways for the technologies still in the pipeline. This could significantly reduce the social and economic burden of implant-related infections in orthopaedics and trauma.
The treatment of osteomyelitis often requires extensive surgical debridement and removal of all infected tissues and foreign bodies. Resulting bone loss can then eventually be managed with antibacterial bone substitutes, that may also serve as a regenerative scaffold. Aim of the present study is to report the clinical results of a continuous series of patients, treated at our centre with an antibacterial bioglass*. From November 2010 to May 2016, a total of 106 patients, affected by osteomyelitis, were included in this prospective, single centre, observational study. Inclusion criteria were the presence of osteomyelitis with a contained bone defect or segmental defects < 10 mm, with adequate soft tissue coverage. All patients underwent a one-stage procedure, including surgical debridement and bone void filling with the bioactive glass*, with systemic antibiotic therapy and no local antibiotics. Clinical, radiographic and laboratory examinations were performed at 3, 6 and 12 months and yearly thereafter.Aim
Method
Biofilm-related infections represent a recurrent problem in the orthopaedic setting. In recent years, great interest was directed towards the identification of novel molecules capable to interfere with pathogens adhesion and biofilm formation on implant surfaces. In this study, two stable forms of α-tocopherol, the hydrophobic acetate ester and the water-soluble phosphate ester, were tested Antimicrobial activity against microorganisms responsible of prosthetic and joints infections was assessed by broth microdilution method. In addition, α-tocopherol esters were evaluated for both their ability to hamper bacterial adhesion and biofilm formation on sandblasted titanium surfaces.Aim
Method
The treatment of chronic osteomyelitis often
includes surgical debridement and filling the resultant void with antibiotic-loaded
polymethylmethacrylate cement, bone grafts or bone substitutes.
Recently, the use of bioactive glass to treat bone defects in infections
has been reported in a limited series of patients. However, no direct comparison
between this biomaterial and antibiotic-loaded bone substitute has
been performed. In this retrospective study, we compared the safety and efficacy
of surgical debridement and local application of the bioactive glass
S53P4 in a series of 27 patients affected by chronic osteomyelitis
of the long bones (Group A) with two other series, treated respectively
with an antibiotic-loaded hydroxyapatite and calcium sulphate compound
(Group B; n = 27) or a mixture of tricalcium phosphate and an antibiotic-loaded
demineralised bone matrix (Group C; n = 22). Systemic antibiotics
were also used in all groups. After comparable periods of follow-up, the control of infection
was similar in the three groups. In particular, 25 out of 27 (92.6%)
patients of Group A, 24 out of 27 (88.9%) in Group B and 19 out
of 22 (86.3%) in Group C showed no infection recurrence at means
of 21.8 (12 to 36), 22.1 (12 to 36) and 21.5 (12 to 36) months follow-up,
respectively, while Group A showed a reduced wound complication
rate. Our results show that patients treated with a bioactive glass
without local antibiotics achieved similar eradication of infection
and less drainage than those treated with two different antibiotic-loaded
calcium-based bone substitutes. Cite this article: