Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure. All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR.Aims
Methods
Ankle fractures in the elderly are an increasing problem with our aging population. Options for treatment include non-operative and operative with a range of techniques available. Failure of treatment can lead to significant complications, morbidity and poor function. We compared the outcomes of two operative techniques, intramedullary hindfoot nailing (IMN) and fibular-pro-tibia fixation (FPT). This is the largest analysis of these techniques and there are no comparative studies published. We retrospectively reviewed patients over the age of 60 with ankle fractures who were treated operatively between 2012 and 2017. We identified 1417 cases, including 27 patients treated with IMN and 41 treated with FPT. Age, sex, co-morbidities and injury pattern were collected. Primary outcome was re-operation rate. Secondary outcomes included other complications, length of stay and functional status.Introduction
Method
We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year.Aims
Methods
Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR. We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.Aims
Methods
Traditional treatment for end-stage ankle arthritis has been ankle arthrodesis, however ankle arthroplasty is becoming an accepted alternative. The Zenith Ankle (Corin, UK) is 3rd generation implant with a mobile bearing design. In the NJR 2016 report, the Zenith was the commonest ankle prosthesis implanted in the UK. However, compared to other ankle implants, there's little published data on its performance and survival. The aim of this study was to analyse outcome in a consecutive series from a non-designer centre. We conducted a retrospective review of a consecutive series of 118 Zenith Ankle replacements implanted in our Unit (December 2010 to May 2016). Data was collected from our National Joint Registry entries, research databases, patient notes, PACS and PROMS.Introduction
Method
Arthroplasty for treatment of end stage hallux rigidus is controversial. Arthrodesis remains the gold-standard, but this procedure is not without complications, with up to 10% non-union, 14% re-operation and 10% transfer metatarsalgia rates reported. The aim of this study was to analyse the outcome of the double-stemmed silastic implant (Wright-Medical) for end stage hallux rigidus. We conducted a retrospective review of a consecutive series of 108 silastic 1st MTPJ implanted in our Unit (January 2005 – December 2016). Data was collected from our research databases, patient notes, PACS and PROMS. No patient was lost to follow-up.Introduction
Method
We present a review of litigation claims relating
to foot and ankle surgery in the NHS in England during the 17-year period
between 1995 and 2012. A freedom of information request was made to obtain data from
the NHS litigation authority (NHSLA) relating to orthopaedic claims,
and the foot and ankle claims were reviewed. During this period of time, a total of 10 273 orthopaedic claims
were made, of which 1294 (12.6%) were related to the foot and ankle.
1036 were closed, which comprised of 1104 specific complaints. Analysis
was performed using the complaints as the denominator. The cost
of settling these claims was more than £36 million. There were 372 complaints (33.7%) involving the ankle, of which
273 (73.4%) were related to trauma. Conditions affecting the first
ray accounted for 236 (21.4%), of which 232 (98.3%) concerned elective
practice. Overall, claims due to diagnostic errors accounted for
210 (19.0%) complaints, 208 (18.8%) from alleged incompetent surgery
and 149 (13.5%) from alleged mismanagement. Our findings show that the incorrect, delayed or missed diagnosis
of conditions affecting the foot and ankle is a key area for improvement,
especially in trauma practice. Cite this article: