Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:

Objective

Neurological injuries are most common complication, which has refrained many surgeons from opting elbow arthroscopy for indicated surgeries. The objective of this study was to evaluate the safety of anterolateral (AL) and posterolateral (PL) portals and chances of injury to the radial nerve and posterior interosseous nerve around the elbow joint during elbow arthroscopy.

Material & Methods

A cadaveric study was conducted on 16 non dissected cadavers (32 elbow specimens) between the period of January 2021 to June 2022. Four portals were established using 4 mm Steinmann pins which are Proximal AL Portal, Mid-AL Portal, Distal AL Portal and PL Portal. The measurements of each portal were taken for each nerve and compared with each other.