Abstract
Objective
Neurological injuries are most common complication, which has refrained many surgeons from opting elbow arthroscopy for indicated surgeries. The objective of this study was to evaluate the safety of anterolateral (AL) and posterolateral (PL) portals and chances of injury to the radial nerve and posterior interosseous nerve around the elbow joint during elbow arthroscopy.
Material & Methods
A cadaveric study was conducted on 16 non dissected cadavers (32 elbow specimens) between the period of January 2021 to June 2022. Four portals were established using 4 mm Steinmann pins which are Proximal AL Portal, Mid-AL Portal, Distal AL Portal and PL Portal. The measurements of each portal were taken for each nerve and compared with each other.
Results
In our study, the mean age was 56.5 years. Proximal AL Portal was found to be at an average distance of 12.03 mm from radial nerve, 9.48 mm from the PIN and 9.35 mm from the PACN (Posterior Antebrachial Cutaneous Nerve). Distal AL Portal was at an average distance of 7.95 mm away from the radial nerve which closest to radial nerve amongst all portals. The radial nerve had the most risk of being injured out of all the nerves in the AL and PL portals followed by PIN and PACN in AL portal. Ulnar nerve was found safe in the PL portal.
Conclusion
The PL portal was safer than the AL portal for conducting elbow arthroscopy. Care should be taken specially to protect radial nerve while performing elbow arthroscopy.