The aim of this study is to report the 30 day COVID-19 related morbidity and mortality of patients assessed as SARS-CoV-2 negative who underwent emergency or urgent orthopaedic surgery in the NHS during the peak of the COVID-19 pandemic. A retrospective, single centre, observational cohort study of all patients undergoing surgery between 17 March 2020 and 3May 2020 was performed. Outcomes were stratified by British Orthopaedic Association COVID-19 Patient Risk Assessment Tool. Patients who were SARS-CoV-2 positive at the time of surgery were excluded.Introduction
Method
The optimal correction of the weight bearing line during High Tibial Osteotomy has not been determined. We used finite element modelling to simulate the effect that increasing opening wedge HTO has on the distribution of stress and pressure through the knee joint during normal gait. Subject-specific models were developed by combining geometry from 7T MRI scans and applied joint loads from ground reaction forces measured during level walking. Baseline stresses and pressures on the articulating proximal tibial cartilage and menisci were calculated. Progressive osteotomies were then simulated to shift the weight-bearing line from the native alignment towards/into the lateral compartment (between 40 – 80% of medial-lateral tibial width). Changes in calculated stresses and pressures were recorded. Both stress and pressure decreased in the medial compartment and increased in the lateral compartment as increasingly valgus osteotomies were simulated. The models demonstrated a consistent “safe zone” for weight bearing line position at 50%-65% medial-lateral tibial width, outside of which compartment stresses and pressures substantial increased. This study suggests a safe correction zone within which a medial opening wedge HTO can be performed correcting the WBL to 55% medio-lateral width of the tibia.
Endoprosthetic replacement (EPR) is an available option for the management of massive bone loss around failed knee implants. The aim of this study was to determine the results of knee EPRs performed for non-tumour indications. Since 2007, 85 EPRs were performed for in a single tertiary centre by seven surgeons. Mean age at surgery was 73.5 years (range:35–95) with infection as the most common indication (49%), followed by aseptic loosening (18%), complex primary replacement (16%), fracture (15%) and mechanical failure (2%). Mean follow up was 4 years (range:1–9). Functional outcome was determined using the Oxford Knee Score (OKS). At follow-up, 21 patients were deceased and 2 lost to follow-up. Complication rate was 19%. Of the 7 infected cases, 6 were treated with DAIR (debridement, antibiotics, and implant retention) and one underwent above knee amputation. Four of the patients undergoing DAIR were cleared of infection and 2 are on long-term antibiotics. Accounting for implant revision, loss to follow-up and those on long-term antibiotics as failures, 5-year survival was 89% with an average OKS of 25 (SD=10). This mid-term study shows that distal femur EPR is a valuable option for the increasing burden of complex revision knee surgery
The burden of peri-prosthetic joint infection (PJI) following hip and knee surgery is increasing. Endoprosthetic replacement (EPR) is an option for management of massive bone loss resulting from infection around failed lower limb implants. To determine clinical outcome of EPRs for treatment of PJI around the hip and knee joint.Introduction
Aims
Current work-hour restrictions and cost pressures have highlighted the limitations of apprenticeship-based learning, and led to the development of alternative methods to improve the skills of orthopaedic trainees outside of the clinical environment. These methods include using synthetic bones and simulators in the laboratory setting. Educational theory highlights the importance of context for effective learning, yet full-immersion simulation facilities are prohibitively expensive. This study explored the concept of contextualised training day in trauma & orthopaedics. Fifteen novice surgeons provided feedback after completing three teaching modules: OSCE-style Problem-based Learning of Orthopaedic Trauma in the Fracture Clinic Setting, utilising an actor and radiographs to teach history, examination, diagnostic and management skills The positioning, preparing and draping of a patient, and Examination under anaesthesia (EUA) for arthroscopic knee surgery, utilising an operating table and theatre equipment to teach procedural and examination skills Simulator based training for diagnostic shoulder and knee arthroscopy; and Bankart repair, utilising arthroscopic stack and synthetic joint models to develop arthroscopic motor skill and procedural knowledgeIntroduction
Methods
This study examines variations in knee arthroplasty patient reported outcome measures according to patient age. We analysed prospectively collected outcome data (OKS, Eq5D, satisfaction, and revision) on 2456 primary knee arthroplasty patients. Patients were stratified into defined age groups (< 55, 55–64, 65–74, 75–84, and ≥85 years). Oxford Knee Score and Eq5D were analysed pre-operatively, and postoperatively at 6 months and 2 years. Absolute scores and post-operative change in scores were calculated and compared between age groups. Satisfaction scores (0–100) were analysed at 6 months post-operatively. Linear, logistic and ordinal regression modelling was used to describe the association between age and outcomes, for continuous, binary and ordinal outcomes, respectively. Kaplan-Meier analysis was performed to describe revision rates at 2 years.Objectives
Methods
Unicompartmental Knee Replacement (UKR) is associated with fewer complications, faster recovery and better function than Total Knee Replacement (TKR). However, joint registries demonstrate a higher revision rate in UKR, limiting its use. Currently most UKRs are cemented and performed using a minimally invasive technique. In joint registries, common reasons for revision include aseptic loosening and pain. These problems could potentially be addressed by using cementless implants, which may provide more reliable fixation. The objectives of this study were to compare the quality of fixation (determined by the incidence and appearance of radiolucencies), and clinical outcomes of cemented and cementless UKR at five years. A randomised controlled trial was established with 63 knees (62 patients) randomised to either cemented (32 patients) or cementless UKR (30 patients). Fixation was assessed with fluoroscopic radiographs aligned to the bone-implant interface at one and five years. Outcome scores were collected pre-operatively and at one, two and five years, including Oxford Knee Score (OKS), American Knee Society Score, objective and functional (AKSS-O/F) and Tegner Activity Scale (TAS), expressed as absolute scores and 0–5 year change (δ) scores. Four patients died during the study period. There were no revisions. Mean operative time was 11 minutes shorter in the cementless group (p=0.029). At five years, there was no significant difference in any outcome measure except AKSS-F and δAKSS-F which were significantly better in the cementless group (both p=0.003). There were no femoral radiolucencies in either group. There were significantly more tibial radiolucencies in the cemented group (20/30 vs 2/27, p< 0.001). There were nine complete radiolucencies in the cemented group and none in the cementless group (p< 0.001). Cementless fixation provides improved fixation at five years compared to cemented fixation in UKR, maintaining equivalent or superior clinical outcomes with a shorter operative time and no increase in complications.
Hip arthroscopy is a relatively new procedure and evidence to support its use remains limited. Well-designed prospective clinical trials with long-term outcomes are required, but study design requires an understanding of current practice. Our aim was to determine temporal trends in the uptake of non-arthroplasty hip surgery in England between 2001 and 2011. Using procedure and diagnosis codes, we interrogated the Hospital Episode Statistics (HES) Database for all hip procedures performed between 2001 and 2011, excluding those relating to arthroplasty, tumour or infection. Osteotomy procedures were also excluded.Introduction
Methods
Indications for Unicompartmental Knee Arthroplasty (UKA) vary between units. Some authors have suggested, and many surgeons believe, that medial UKA should only be performed in patients who localise their pain to the medial joint line. This is despite research showing a poor correlation between patient-reported location of pain and radiological or operative findings in osteoarthritis. The aim of this study is to determine the effect of patient-reported pre-operative pain location and functional outcome of UKA at one and five years. Pre-operative pain location data were collected for 406 knees (380 patients) undergoing Oxford medial UKA. Oxford Knee Score, American Knee Society Scores and Tegner activity scale were recorded preoperatively and at follow-up. 272/406 (67%) had pure medial pain, 25/406 (6%) had pure anterior knee pain and 109/406 (27%) had mixed or generalised pain. None had pure lateral pain. The primary outcome interval is one year; 132/406 patients had attained five years by the time of analysis and their five year data is presented. At one and five years, each group had improved significantly by each measure (mean δOKS 15.6 (SD 8.9) at year one, 16.3 (9.3) at year five). There was no difference between the groups, nor between patients with and without anterior knee pain or isolated medial pain. We have found no correlation between preoperative pain location and outcome. We conclude that localised medial pain should not be a prerequisite to UKA and that it may be performed in patients with generalised or anterior knee pain.
Restrictions placed on the working hours of doctors have led to increasing time-pressures on surgical training. Consequently, there has been growing interest in developing new techniques to teach and assess technical skills. The primary aim of this study was to determine whether a novel set of visual parameters assessing visuospatial ability, fine motor dexterity and gaze control could objectively distinguish between varying levels of arthroscopic experience. The secondary aim was to evaluate the correlations between these new parameters and previously established technical skill assessment methods. 27 subjects were divided into a “novice” group (n=7), “trainee” group (n=15) and expert group (n=5) based on previous arthroscopic experience. All subjects performed a diagnostic knee arthroscopy task on a simulator. Their performance was assessed using new simple visual parameters that included “prevalence of instrument loss,” “triangulation time” and “prevalence of look downs”. In addition, performance was also evaluated using previously validated technical skill assessment methods (a global rating scale and motion analysis).Introduction
Methods
Motion analysis is a validated method of assessing technical dexterity within surgical skills centers. A more accessible and cost-effective method of skills assessment is to use a global rating scale (GRS). We aimed to perform a validation experiment to compare an arthroscopic GRS against motion analysis for monitoring orthopaedic trainees learning simulated arthroscopic meniscal repairs. An arthroscopic meniscal repair task on a knee simulator was set up in a bioskills laboratory. Nineteen orthopaedic trainees with no experience of meniscal repair were recruited and their performance assessed whilst undertaking a standardized meniscal repair on 12 occasions. An arthroscopic GRS, assessing parameters such as “depth perception,” “bimanual dexterity,” “instrument handling,” and “final product analysis” was used to evaluate technical skill. Performance was assessed blindly by watching video recordings of the arthroscopic tasks. Dexterity analysis was performed using a motion analysis tracking system which measured “time taken,” “total path length of the subject's hands,” and “number of hand movements”.Introduction
Methods
Despite interest, the current rate of day-case anterior cruciate ligament reconstruction (ACLR) in the UK remains low. Although specialised care pathways with standard operating procedures (SOPs) have been effective in reducing length of stay following some surgical procedures, this has not been previously reported for ACLR. We evaluate the effectiveness of SOPs for establishing day-case ACLR in a specialist unit. Fifty patients undergoing ACLR between May and September 2010 were studied prospectively (“study group”). SOPs were designed for pre-operative assessment, anaesthesia, surgical procedure, mobilisation and discharge. We evaluated length of stay, readmission rates, patient satisfaction and compliance to SOPs. A retrospective analysis of 50 patients who underwent ACLR prior to implementation of the day-case pathway was performed (“standard practice group”).Background
Methods
Interest in soft tissue Radiostereometric Analysis (RSA) is rising. Previous authors have tried, with varying levels of success, to use this technique to analyse the intra-substance portion of anterior cruciate ligament (ACL) graft constructs. These methods were either prone to large amounts of marker migration, deemed unsuitable for in-vivo use or, where alternative markers such as stainless steel sutures were used, lost the inherent accuracy that made RSA an attractive tool in the first place. We describe a modification of tantalum marker balls that allows for a new method of secure fixation to soft tissue in order to accurately analyse stretch, displacement and, potentially, dynamic movement using RSA. 1.5 mm tantalum tendon markers were predrilled with 0.3 mm holes, allowing them to be sutured directly to soft tissue. Using a previously described ACL graft model, the amount of marker ball migration was then analysed using RSA after cyclical loading between 20 N and 170 N at 25 Hz for 225,000 cycles.Aims
Methods
Surgical marking during tendon surgery is often used for technical
and teaching purposes. This study investigates the effect of a gentian
violet ink marker pen, a common surgical marker, on the viability
of the tissue and cells of tendon.
Objectives
Methods
To investigate the effect of lab-based simulator training, on the ability of surgical trainees to perform diagnostic knee arthroscopy. 20 orthopaedic SHOs with minimal arthroscopic experience were randomised to 2 groups. 10 received a fixed protocol of simulator based arthroscopic skills training using a bench-top knee model. Learning curves were clearly demonstrated using motion analysis equipment to monitor performance. All 20 then spent an operating list with a blinded consultant trainer. They received instruction and demonstration of diagnostic knee arthroscopy before performing the procedure independently. Their performance was assessed using the intra-operative section of the Orthopaedic Competence Assessment Project (OCAP) procedure based assessment (PBA) protocol for diagnostic arthroscopy. Performance was further quantified with a ten point global rating assessment scale.Objective
Method