Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 38 - 38
1 Jul 2020
Lalone E Suh N Perrin M Badre A
Full Access

Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius.

Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm LCP Volar Column (VC) Distal Radius Plate (8-hole and 9-hole head). Plates were placed onto the distal radii models in a 3D visualization software by a fellowship-trained orthopaedic hand surgeon. The percent contact, volar cortical angle (VCA), border and overlap of the watershed line (WSL) were measured.

Both sexes showed an increase in the average VCA measure from medial to lateral columns which was statistically significant. Female VCA ranged from 28 – 36 degrees, and 38 – 45 degrees for males. WSL overlap ranged from 0 – 34.7629% for all specimens without any statistical significance. The average border distance for females was 2.58571 mm, compared to 3.52411 mm for males, with EA plates having a larger border than VC plates. The border distances had statistically significant differences between the plate types, and was approaching significance between sexes. Lastly, a maximum percent contact of 21.966 % was observed in specimen F4 at a 0.3 mm threshold. No statistical significance between plate or sex populations was observed.

This study investigated the incoherency between the volar cortical angle of the distal radius, and the pre-contoured angle of volar locking plates. It was hypothesized that if the VCA measures between plate and bone were unequal then there would be an increase in watershed line overlap, and decrease in percent contact between the surfaces. Our results agreed with literature, indicating that the VCA of bone was larger than that of the EA and VC pre-contoured plates examined in this study.

With distal radius fracture incidences and prevalence on the rise for elderly female patients, it is a necessity that volar locking plates be re-designed to factor in anatomical features of individual patients with a particular focus on sex differences. New designs should focus on providing smaller head sizes that are more accurately tailored to the natural contours of the volar distal radius. It is recommended that future studies incorporate expertise from multiple surgeons to diversify and further understand plate placement strategies.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 37 - 37
1 Jul 2020
Lalone E Grewal R Seltser A Albakri K MacDermid J Suh N Perrin M
Full Access

Scaphoid fractures are a common injury accounting for more than 58% of all carpal bone fractures(1,2). Biomechanical studies have suggested that scaphoid mal-union may lead to altered carpal contact mechanics causing decreased motion, pain and arthritis(1,2). The severity of mal-union required to cause deleterious effects has yet to be established. This limits the ability to define surgical indications or impacts on prevention of posttraumatic arthritis. Computed tomography has been shown to be a useful in determining the 3D implications of altered bony alignment on the joint contact mechanics of surrounding joints. The objective of this study was to report mid-term follow-up image-based outcomes of patients with scaphoid mal-unions to determine the extent to which arthritic changes and decreased joint space is present after a minimum of 4 years following fracture.

Participants (n=14) who had previously presented with a mal-united scaphoid fracture (indicated by a Height:Length Ratio >0.6) between November 2005 and November 2013 were identified and contacted. A short-arm thumb spica case was used to treat X patients and X required surgical management. Baseline and follow-up CT images, were performed with the wrist in radial deviation and positioned such that the long axis of the scaphoid was perpendicular to the axis of the scanner. Three-dimensional inter-bone distance (joint space), a measure of joint congruency and 3D alignment, was quantified from reconstructed CT bone models of the distal radius, scaphoid, lunate, capitate, trapezium and trapezoid from both the baseline and follow-up scans(3). Repeated measures ANOVA was used to detect differences in contact area (mm2) between baseline and follow-up CT's for the radioscaphoid, scaphocapitate and scaphotrapezium-trapezoid joint.

The average age of participants was 43.1 years (16–64 years old). There was significant loss of joint space, indicated by a greater joint contact area 3–4 years post fracture, between baseline and follow-up reconstruction models, at the scaphocapitate (mean difference: 21.5±146mm2, p=0.007) and scaphotrapezoid joints (mean difference: 18.4 ±28.6mm2, 0.042). Significant differences in the measured contact area was not found for the radioscaphoid (0.153) and scaphotrapezium joints (0.72). Additionally, the scaphoid, qualitatively, appears to track in the vorsal direction in the majority of patients following fracture.

Increased joint contact area in the scaphocapitate and scaphotrapezoid joint 3–4 years following fracture results from decreased 3D joint space and overall narrowing. Joint space narrowing, while not significantly different for all joints examined, was reduced for all joints surrounding the scaphoid. Decreased joint space and increased contact area detectable within this short interval might be suggestive of a trajectory for developing arthritis in the longer term, and illustrates the potential value of these measures for early detection. Longer term follow-up and correlation to clinical outcomes are needed to determine the importance of early joint space narrowing, and to identify those most at risk.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 113 - 113
1 Jul 2020
Badre A Perrin M Albakri K Suh N Lalone E
Full Access

Distal radius fractures are the most common upper extremity fracture. The incidence is significantly higher in elderly females with osteoporotic bone. When surgery is indicated, volar locking plates (VLPs) allow for rigid fixation particularly in comminuted fractures with poor bone quality. Although numerous studies have shown the importance of plate placement to avoid soft tissue complications associated with volar plate fixation, there has been little evidence on the anatomic fit of current VLPs. Moreover, the effect of gender differences in distal radius morphology on anatomic fitting of VLPs has not been studied. The aim of this study was to evaluate the gender difference in distal radius morphology and the accuracy of the fit of a current VLP to CT-based distal radius models.

Segmented CT models of ten female (mean age, 89 ± 5 years), and ten male (mean age, 86 ± 4 years) cadaveric wrists were obtained. Micro-CT models of the DePuy-Synthes 4-hole extra-articular (EA) and 8-hole volar column (VC) distal radius VLPs were created. A 3D visualization software was used to simulate appropriate plate placement on to the distal radius models by a fellowship-trained hand surgeon. Volar cortical angles (VCA) of the medial, middle and lateral portion of the distal radius were measured and compared between genders. The accuracy of the fit of the two VLP designs were quantified using the percentage of the watershed line (WSL) overlapped by the plate (WSL overlap), the distance between the WSL and the most distal aspect of the posterior plate (prominence distance) and the percentage of contact between the plate and bone.

There were statistically significant gender differences in medial, middle and lateral VCAs (p=.003 medial, p=.0001 middle, p=.002 lateral). VCA ranged from 28° to 36° in females and from 38° to 45° in males. The WSL overlap did not show statistically significant gender differences (male: 5.9%, female: 13.6%, p=.174). However, the difference in prominence distance between different genders approached statistical significance (male: 3.5mm, female: 2.6mm, p=.087). Contact mapping between the plate and bone did not demonstrate a perfect contact in any of our specimens. Thus, contact measurements were categorized into 0.1mm, 0.2mm, and 0.3mm threshold contacts. There were no statistically significant gender differences in any of the threshold categories (0.1mm: p=.84, 0.2mm: p=.97, 0.3mm: p=.99).

Our results confirm that there are gender differences in distal radius morphology. Current plate designs incorporate a VCA of 25° which does not match the native VCA of the distal radius in males or females. Although the difference in prominence distance approached statistical significance, there were no statistically significant gender differences in the WSL overlap or the contact threshold values. This lack of statistical significance may be related to the small sample size. This study proposes novel methods of assessing the anatomic fit of current VLPs in a 3D CT-based model that may be used in future studies with a larger sample size. Moreover, this study demonstrated the importance of considering gender differences in distal radius morphology in the design of future generations of implants.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 66 - 66
1 Jan 2004
Perrin M Fraisse J Cuisenier J
Full Access

Purpose: Replacing the entire femur for primary bone tumour is exceptional. Prostheses used in this series were custom-made by Link using the Endo Klinik (Hambourg) model. These prostheses have adjustable ante-version and a hinge type knee with rotation.

Patients and Results: Case n° 1. A 15-year-old boy, grade 2A osteosarcoma in the diaphyseal zone of the lower femur. Rosen chemotherapy. En bloc resection. Total femur prosthesis sleeved onto the trochanteric mass left in place. Excellent response:100%. Excellent functional result: mountain climbing! Current status: recurrence-free, metastasis-free at 16 years follow-up. Case n° 2. Adult osteosarcoma. 68-year-old woman with pulmonary metastasis at diagnosis. Indication due to fracture to mid third of femur. Excellent immediate result. Nine-month survival in very satisfactory condition. Case n° 3. 72-year-old woman treated one year earlier for T1N0M0 breast cancer. Metastatic image in the trochanter. Treatment by curettage and THA. Histology reported chondrosarcoma. Scintigraphy showed uptake in gluteus medius and the lower part of the femur. En bloc resection of entire femur and gluteus medius. Total femur replacement with prosthesis sleeved onto an allograft. Complete resection. Current status: recurrence-free, metastasis-free at five years. No limitation on walking distance. Walks with cane due to moderate limp. Case n° 4. Adult osteosarcoma (32 years). Low-grade tumour (1B) occupying the entire femur. Rizzoli Institute chemotherapy protocol. Resection and total femur replacement with prosthesis sleeved onto an allograf. Complete resection. Poor response. Excellent functional result, persistence of minimal limp. Active tumour with pulmonary metastasis at one year and death at 1.5 yers. Case n° 5. Grade 2B osseous leiomyosarcoma in the diaphyseal zone of the lower femur in a 37-year-old woman. Neoadjuvant chemotherapy followed by total femur resection. Excellent responder:100%. Excellent functional outcome at short follow-up (1 year).

Discussion: Total femur replacement with a prostheses sleeved on an allograft allows reinsertion of the gluteus medius and the psoas. This method is reliable and avoids major instability. Complications in this small number of patients were rare and were not serious. The functional results have been excellent and appear to depend primarily on the importance of muscle resection required to achieve tumour resection.