Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 2 - 2
19 Aug 2024
Becker L Resl M Wu Y Kirschbaum S Perka C
Full Access

Studies and meta-analyses worldwide show an increased use of one-stage revisions for treating periprosthetic hip infections, often yielding comparable or better outcomes than two-stage revisions. However, it remains unclear if these successful results can be consistently achieved nationwide besides large centers.

This observational cohort study used data from the German Arthroplasty Registry (EPRD) to compare the mortality and re-revision rates between one-stage (n=8183) and two-stage (n=657) first-time revision total hip arthroplasty (RTHA). Kaplan-Meier estimates were applied to evaluate the re-revision rate and cumulative mortality for RTHA.

There was a significant difference in mortality between one-stage and two-stage RTHA (p=0.02). One-year post-surgery, the mortality rate was 9.4% for one-stage revisions and 5.5% for two-stage revisions. At the five-year follow-up, the mortality rate for one-stage revisions was 25.5%, compared to 20.0% for two-stage revisions. No significant differences (p=0.30) were found in re-revision rates between one-stage and two-stage revisions after one year (one-stage 16.5% vs. two-stage 13.5%) or five years (one-stage 21.6% vs. two-stage 20.8%). For multiple revisions, the mortality differences were even larger (p<0.001), with a one-year mortality rate of 12.8% for one-stage RTHA and 5.7% for two-stage RTHA.

Despite the excellent results of one-stage RTHA in the literature from individual large centers, it shows a significantly higher mortality rate with equal re-revision rate compared to two-stage revision in the nationwide care besides large centers. Significant differences can already be seen within the first year, indicating an increased perioperative mortality for one-stage revision, which might be explained by longer surgery duration, blood-loss and patient selection or maybe a lack of experience concerning proper surgical debridement for one-stage revision. This illustrates the need to establish centers for joint-revision surgery that provide interdisciplinary care and high case numbers to improve perioperative outcomes.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 55 - 55
19 Aug 2024
Morlock M Wu Y Grimberg A Günther K Michel M Perka C
Full Access

Implant fracture of modular revision stems is a major complication after total hip arthroplasty revision (rTHA). Studies looking at specific modular designs report fracture rates of 0.3% to 0.66% whereas fractures of monobloc designs are only reported anecdotally. It is unclear whether the overall re-revision rate of modular designs is higher and if, whether stem fractures or other revision reasons are responsible for this elevation.

All revisions within 5 years after implantation of a revision stems (n0=13,900; n5=2506) were analysed using Cox regression with design (modular: n=17, monobloc: n=27), BMI, Sex and Elixhauser Score as independent variables. One stage and two stage revisions were analysed separately (1-stage: modular n= 7,102; monobloc n= 4,542; 2-stage: 1,551 / 704). The revision volume of the hospitals was also considered (low: <20 revisions, medium: 21–50 revisions, high: >50 revisions).

For the 1-stage revisions, the re-revision risk after 4 years was 14,3% [13.2%, 15.5%] for monobloc and 17.4% [16.40%, 18.40%] for modular stems (p< 0.001). Stem fracture was the reason for re-revision in 2.4% of the modular (fracture rate 0.42%) and 0.6% of the monobloc revisions. The difference in re-revision rates between the designs was mainly due to differences in dislocation and stem loosening. For the 2-stage revisions, the revision risks for either design were similar (21.7% [18,5%, 25.4%] vs. 23.0% [20.8%, 25.4%]; p=0.05). Patient characteristics influenced the comparison between the two designs in the 1-stage group but very little in the 2-stage group.

Modular revision stem fractures only contribute very minor to re-revision risk. In 2-stage revisions, no difference in overall re-revision rates between designs was observed. This might indicate that the differences observed for 1-stage procedures are due to differences between the patient cohorts, not reflected by the parameters available or surgeon choice.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 479 - 488
6 Jun 2024
Paksoy A Meller S Schwotzer F Moroder P Trampuz A Imiolczyk J Perka C Hackl M Plachel F Akgün D

Aims

Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in hip arthroplasty PJI patients.

Methods

This was a prospective pilot study, including 24 patients divided into three groups, with eight patients each undergoing revision of their hip arthroplasty due to aseptic reasons, and low- and high-grade PJI, respectively. The number of intraoperative samples and the incidence of positive cultures were recorded for each patient. Additionally, venous blood samples and periarticular tissue samples were collected from each patient to determine miRNA expressions between the groups. MiRNA screening was performed by small RNA-sequencing using the miRNA next generation sequencing (NGS) discovery (miND) pipeline.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 565 - 572
1 Jun 2024
Resl M Becker L Steinbrück A Wu Y Perka C

Aims

This study compares the re-revision rate and mortality following septic and aseptic revision hip arthroplasty (rTHA) in registry data, and compares the outcomes to previously reported data.

Methods

This is an observational cohort study using data from the German Arthroplasty Registry (EPRD). A total of 17,842 rTHAs were included, and the rates and cumulative incidence of hip re-revision and mortality following septic and aseptic rTHA were analyzed with seven-year follow-up. The Kaplan-Meier estimates were used to determine the re-revision rate and cumulative probability of mortality following rTHA.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 758 - 765
12 Oct 2023
Wagener N Löchel J Hipfl C Perka C Hardt S Leopold VJ

Aims

Psychological status may be an important predictor of outcome after periacetabular osteotomy (PAO). The aim of this study was to investigate the influence of psychological distress on postoperative health-related quality of life, joint function, self-assessed pain, and sports ability in patients undergoing PAO.

Methods

In all, 202 consecutive patients who underwent PAO for developmental dysplasia of the hip (DDH) at our institution from 2015 to 2017 were included and followed up at 63 months (SD 10) postoperatively. Of these, 101 with complete data sets entered final analysis. Patients were assessed by questionnaire. Psychological status was measured by Brief Symptom Inventory (BSI-18), health-related quality of life was raised with 36-Item Short Form Survey (SF-36), hip functionality was measured by the short version 0f the International Hip Outcome Tool (iHOT-12), Subjective Hip Value (SHV), and Hip Disability and Outcome Score (HOS). Surgery satisfaction and pain were assessed. Dependent variables (endpoints) were postoperative quality of life (SF-36, HOS quality of life (QoL)), joint function (iHOT-12, SHV, HOS), patient satisfaction, and pain. Psychological distress was assessed by the Global Severity Index (GSI), somatization (BSI Soma), depression (BSI Depr), and anxiety (BSI Anx). Influence of psychological status was assessed by means of univariate and multiple multivariate regression analysis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 44 - 44
23 Jun 2023
Scholz J Perka C Hipfl C
Full Access

Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation.

We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation, leg length and offset. Risk factors for re-dislocation were determined by cox regression analysis. Modified Harris hip scores (mHHS) were calculated. Mean follow-up was 53 months (1 to 103).

DM constructs were used more frequently in elderly patients (p=0.011) and hips with abductor deficiency (p< 0.001). The re-dislocation rate was 11.1% for DM bearings compared with 15.9% for standard bearings and 18.2% for CL (p=0.732). Revision-free survival for DM constructs was 83% (95% CI 0.77 – 0.90) compared to 75% (95% CI 0.68 – 0.82) for standard articulations and 71% (95% CI 0.56 – 0.85) for CL (p=0.455). Younger age (HR 0.91; p=0.020), lower comorbidity (HR 0.42; p=0.031), smaller heads (HR 0.80; p=0.041) and cup retention (HR 8.23; p=0.022) were associated with re-dislocation. Radiological analysis did not reveal a relationship between restoration of hip geometry and re-dislocation. mHHS significantly improved from 43.8 points to 65.7 points (p<0.001) with no differences among bearing types.

Our findings suggest that DM bearings do not sufficiently prevent dislocation in revision THA for recurrent dislocation. Reconstruction of the abductor complex may play a key role to reduce the burden in these high-risk patients.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 801 - 810
1 Jul 2022
Krull P Steinbrück A Grimberg AW Melsheimer O Morlock M Perka C

Aims

Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA).

Methods

We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 28 - 28
1 Nov 2021
Perka C Krull P Steinbrück A Morlock M
Full Access

Special acetabular polyethylene (PE) liners are intended to increase the stability of the artificial hip joint, yet registry studies on them are limited. The pupose of this study was to investigate differences in revision rates for mechanical complications in primary cementless total hip arthroplasty (THA) with standard and special PE acetabular liners in patients with ostheoarthritis.

Data from the German Arthroplasty Registry (EPRD) between 2012 until 2020 were analysed. Patients with diagnosed ostheoarthritis of the hip without relevant prior surgeries, who received a primary cementless THA with a ceramic/PE bearing articulation were included. Cumulative incidences of revision for mechanical complications for Standard and 4 special PE liners (Lipped, Increased Offset, Angulated, Angulated|Increased Offset) were determined using the Kaplan-Meier Estimator. Confounding factors were investigated with a Cox proportional-hazards model.

In total 151.104 cases were included. 7-year unadjusted revision-free survival for mechanical complications compared to Standard liners (97.7%) was lower for Angulated (97.4%), Lipped (97.2%) and Angulated|Increased Offset liners (94.7%), but higher for Increased Offset liners (98.1%). Risk of revision for mechanical complications was not significantly different between Standard, Lipped and Angulated liners. Increased Offset liners (HR=0.68; 95% CI=0.5–0.92) reduced, while Angulated|Increased Offset liners (HR= 1.81; 95% CI=1.38–2.36) increased the risk. Higher age at admission and an Elixhauser comorbidity index greater zero increased the risk, whereas a larger liner share slightly reduced the risk.

Only the use of Increased Offset liners reduced the risk of revision for mechanical complications compared to Standard liners — other special liners did not.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1070 - 1077
1 Jun 2021
Hipfl C Mooij W Perka C Hardt S Wassilew GI

Aims

The purpose of this study was to evaluate unexpected positive cultures in total hip arthroplasty (THA) revisions for presumed aseptic loosening, to assess the prevalence of low-grade infection using two definition criteria, and to analyze its impact on implant survival after revision.

Methods

A total of 274 THA revisions performed for presumed aseptic loosening from 2012 to 2016 were reviewed. In addition to obtaining intraoperative tissue cultures from all patients, synovial and sonication fluid samples of the removed implant were obtained in 215 cases (79%) and 101 cases (37%), respectively. Histopathological analysis was performed in 250 cases (91%). Patients were classified as having low-grade infections according to institutional criteria and Musculoskeletal Infection Society (MSIS) International Consensus Meeting (ICM) 2013 criteria. Low-grade infections according to institutional criteria were treated with targeted antibiotics for six weeks postoperatively. Implant failure was defined as the need for re-revision resulting from periprosthetic joint infection (PJI) and aseptic reasons. The mean follow-up was 68 months (26 to 95).


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 573 - 579
1 May 2020
Krueger DR Guenther K Deml MC Perka C

Aims

We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed.

Methods

All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 311 - 316
1 Mar 2019
Löchel J Janz V Hipfl C Perka C Wassilew GI

Aims

The use of trabecular metal (TM) shells supported by augments has provided good mid-term results after revision total hip arthroplasty (THA) in patients with a bony defect of the acetabulum. The aim of this study was to assess the long-term implant survivorship and radiological and clinical outcomes after acetabular revision using this technique.

Patients and Methods

Between 2006 and 2010, 60 patients (62 hips) underwent acetabular revision using a combination of a TM shell and augment. A total of 51 patients (53 hips) had complete follow-up at a minimum of seven years and were included in the study. Of these patients, 15 were men (29.4%) and 36 were women (70.6%). Their mean age at the time of revision THA was 64.6 years (28 to 85). Three patients (5.2%) had a Paprosky IIA defect, 13 (24.5%) had a type IIB defect, six (11.3%) had a type IIC defect, 22 (41.5%) had a type IIIA defect, and nine (17%) had a type IIIB defect. Five patients (9.4%) also had pelvic discontinuity.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1442 - 1448
1 Nov 2018
Hipfl C Janz V Löchel J Perka C Wassilew GI

Aims

Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems.

Patients and Methods

We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 20 - 20
1 Jan 2018
Renz N Mudrovcic S Trampuz A Perka C
Full Access

Cutibacterium species (formerly Propionibacterium species) are increasingly recognized as causative pathogens of low-grade periprosthetic joint infections (PJI). The clinical manifestation of infections caused by this low virulent microorganism is nonspecific and the interpretation remains challenging. In this prospective cohort study from 01/2012 to 07/2017 we analyzed the clinical and diagnostic characteristics of microbiologically proven hip PJI caused by Cutibacterium species. PJI was defined by growth of Cutibacteria in ≥2 periprosthetic tissue samples or in sonication fluid of the removed implant (>50 CFU/ml) at revision surgery. If Cutibacteria grew only in synovial fluid at least one other positive microbiological specimen or non-microbiological criterion was required.

We included 26 patients suffering from Cutibacterium hip PJI, among them 19 were males (73%). The majority of PJI (24, 92%) presented delayed (3–24 months) or late (>24 months) after implantation. Sinus tract was present in 4 patients (16%) and radiological implant loosening in 16 patients (62%). Among non-microbiological diagnostic tests, increased synovial fluid leukocyte count showed the highest sensitivity (82%), followed by tissue histology (71%) and serum C-reactive protein (58%). After 7 days of incubation Cutibacterium grew in synovial fluid, periprosthetic tissue and sonication fluid culture in 20%, 42% and 32%, respectively, and in 43%, 76% and 83%, respectively, after 14 days of incubation.

We conclude that Cutibacterium PJI was diagnosed late in the disease course and presented with subtle clinical signs. Prolonged culture incubation and implant sonication improved the poor performance of conventional microbiological tests. Due to lack of reliable diagnostic tests, Cutibacterium remains difficult to detect making the diagnosis challenging.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1584 - 1589
1 Dec 2017
Wassilew GI Heller MO Janz V Perka C Müller M Renner L

Aims

This study sought to establish the prevalence of the cross over sign (COS) and posterior wall sign (PWS) in relation to the anterior pelvic plane (APP) in an asymptomatic population through reliable and accurate 3D-CT based assessment.

Materials and Methods

Data from pelvic CT scans of 100 asymptomatic subjects (200 hips) undertaken for conditions unrelated to disorders of the hip were available for analysis in this study. A previously established 3D analysis method was applied to assess the prevalence of the COS and PWS in relation to the APP.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 14 - 17
1 Jan 2016
Sentuerk U von Roth P Perka C

The leading indication for revision total hip arthroplasty (THA) remains aseptic loosening owing to wear. The younger, more active patients currently undergoing THA present unprecedented demands on the bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest rates of wear. The recent advances, especially involving alumina/zirconia composite ceramic, have led to substantial improvements and good results in vitro.

Alumina/zirconia composite ceramics are extremely hard, scratch resistant and biocompatible. They offer a low co-efficient of friction and superior lubrication and lower rates of wear compared with other bearings. The major disadvantage is the risk of fracture of the ceramic. The new composite ceramic has reduced the risk of fracture of the femoral head to 0.002%. The risk of fracture of the liner is slightly higher (0.02%).

Assuming that the components are introduced without impingement, CoC bearings have major advantages over other bearings. Owing to the superior hardness, they produce less third body wear and are less vulnerable to intra-operative damage.

The improved tribology means that CoC bearings are an excellent choice for young, active patients requiring THA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):14–17.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1604 - 1607
1 Dec 2015
Wassilew GI Perka C Janz V Krämer M Renner L

We have investigated the effect of using tranexamic acid (TXA) during peri-acetabular osteotomy (PAO) on peri-operative blood loss and blood transfusion requirements. In addition we analysed whether the use of TXA was associated with an increased risk of venous thromboembolism (VTE) following this procedure.

A consecutive series of 96 PAOs, performed by a single surgeon, were reviewed. A total of 48 patients received TXA and 48 did not. The TXA group received a continuous infusion of TXA at a rate of 10 mg/kg/h. The primary outcome measure was the requirement for blood transfusion. Secondary outcomes included total blood loss, the decrease in the level of haemoglobin in the blood, the length of hospital stay, and the complications of this treatment.

The mean rate of transfusion was significantly lower in the TXA group (62.5% vs 12.5%, p < 0.001). The mean blood loss was also significantly reduced in the TXA group (1.9 L (standard deviation (sd) 0.9) vs 1.5 L (sd 0.7), p < 0.01). No post-operative episodes of VTE were identified in either group.

The use of TXA reduced the blood loss and the rate of transfusion after PAO significantly, without adverse effects such as an increased rate of VTE.

Cite this article: Bone Joint J 2015;97-B:1604–7.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1615 - 1622
1 Dec 2015
Müller M Abdel MP Wassilew GI Duda G Perka C

The accurate reconstruction of hip anatomy and biomechanics is thought to be important in achieveing good clinical outcomes following total hip arthroplasty (THA). To this end some newer hip designs have introduced further modularity into the design of the femoral component such that neck­shaft angle and anteversion, which can be adjusted intra-operatively. The clinical effect of this increased modularity is unknown. We have investigated the changes in these anatomical parameters following conventional THA with a prosthesis of predetermined neck–shaft angle and assessed the effect of changes in the hip anatomy on clinical outcomes.

In total, 44 patients (mean age 65.3 years (standard deviation (sd) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²) (sd 3.1)) underwent a pre- and post-operative three-dimensional CT scanning of the hip. The pre- and post-operative neck–shaft angle, offset, hip centre of rotation, femoral anteversion, and stem alignment were measured. Additionally, a functional assessment and pain score were evaluated before surgery and at one year post-operatively and related to the post-operative anatomical changes.

The mean pre-operative neck–shaft angle was significantly increased by 2.8° from 128° (sd 6.2; 119° to 147°) to 131° (sd 2.1; 127° to 136°) (p = 0.009). The mean pre-operative anteversion was 24.9° (sd 8; 7.9 to 39.1) and reduced to 7.4° (sd 7.3; -11.6° to 25.9°) post-operatively (p < 0.001). The post-operative changes had no influence on function and pain. Using a standard uncemented femoral component, high pre- and post-operative variability of femoral anteversion and neck–shaft angles was found with a significant decrease of the post-operative anteversion and slight increase of the neck–shaft angles, but without any impact on clinical outcome.

Cite this article: Bone Joint J 2015;97-B:1615–22.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1618 - 1622
1 Dec 2014
von Roth P Abdel MP Wauer F Winkler T Wassilew G Diederichs G Perka C

Intact abductors of the hip play a crucial role in preventing limping and are known to be damaged through the direct lateral approach. The extent of trauma to the abductors after revision total hip replacement (THR) is unknown. The aim of this prospective study was to compare the pre- and post-operative status of the gluteus medius muscle after revision THR. We prospectively compared changes in the muscle and limping in 30 patients who were awaiting aseptic revision THR and 15 patients undergoing primary THR. The direct lateral approach as described by Hardinge was used for all patients. MRI scans of the gluteus medius and functional analyses were recorded pre-operatively and six months post-operatively. The overall mean fatty degeneration of the gluteus medius increased from 35.8% (1.1 to 98.8) pre-operatively to 41% (1.5 to 99.8) after multiple revision THRs (p = 0.03). There was a similar pattern after primary THR, but with considerably less muscle damage (p = 0.001), indicating progressive muscle damage. Despite an increased incidence of a positive Trendelenburg sign following revision surgery (p = 0.03) there was no relationship between the cumulative fatty degeneration in the gluteus medius and a positive Trendelenburg sign (p = 0.26). The changes associated with other surgical approaches to the hip warrant investigation.

Cite this article: Bone Joint J 2014;96-B:1618–22.