Hip resurfacing arthroplasty (HRA) in patients with a varus deformity of the femoral neck-shaft angle (NSA) is associated with poorer outcomes. Our experience has not reflected this. We examined the Oxford Hip Scores (OHS), Harris Hip Scores (HHS) and outcomes of patients with varus hips against a normal cohort to ascertain any significant difference. We identified 179 patients. Measurement of the femoral neck-shaft angle was undertaken from antero-posterior radiographs pre-operatively. The mean NSA was 128.5 degrees (SD 6.3). Patients with a NSA of less than 122.2 were deemed varus and those above 134.8 valgus. These parameters were consistent with published anatomical studies. The varus cohort consisted of 23 patients, mean NSA 118.7 (range 113.6-121.5), mean follow-up 49 months (range 13-74). Mean OHS and HHS were 16 and 93.5 respectively. Complications included 2 cases of trochanteric non-union; no femoral neck fractures, early failures or revisions. Normal cohort consisted of 125 patients, mean NSA 128 degrees, mean follow-up 41 months (range 6-76). The OHS and HSS were 18.8, 88.9 respectively. Complications included 5 trochanteric non-unions and 1 revision due to an acetabular fracture following a fall. Statistical analysis demonstrated no statistical difference between the cohorts OHS (p=0.583) or HHS (p=0.139). Our experience in patients with a varus femoral neck has been positive. Our analysis has demonstrated no statistical difference in hip scores between the cohorts. We have not yet experienced any femoral neck fractures, which we believe is due to the use of the Ganz trochanteric flip and preservation of blood supply.
Hip resurfacing arthroplasty (HRA) in patients with a varus deformity of the femoral neck-shaft angle (NSA) has been cited in the literature as contributory factor towards a poorer outcome. Our experience has not reflected this. We examined the outcomes of patients with varus hips against a normal cohort. Measurement of the femoral neck-shaft angle was undertaken from standard antero-posterior radiographs pre-operatively. The mean NSA was 128.5 degrees (SD 6.3). Patients less than 122.2 were deemed varus and those above 134.8 valgus. These parameters were consistent with the published literature. The varus cohort consisted of 23 patients, mean NSA 118.7 (range 113.6-121.5), mean follow-up 49 months (range 13-74), mean OHS & HHS, 16 & 93.5 respectively. Complications included 2 cases of trochanteric non-union; no femoral neck fractures or revisions. The normal cohort consisted of 125 patients, mean NSA 128 degrees, mean follow-up 41 months (range 6-76), mean OHS & HSS, 18.8 & 88.9 respectively. Complications included 5 cases of trochanteric non-union and 1 revision. Statistical analysis demonstrated no difference between the cohorts OHS (p=0.583) or HHS (p=0.139). Our experience in patients with a varus femoral neck has been positive. Our analysis has demonstrated no difference in outcomes between the cohorts.
The role of magnetic resonance arthrography (MRA) in the evaluation of patients with femeroacetabular impingement (FAI) to assess femoral head-neck junction asphericity and labral pathology is well established. However, in our experience the presence of acetabular cysts on MRA, which may signify underlying full thickness articular cartilage delamination and progression towards arthropathy, is also an important feature. We retrospectively reviewed 142 hips (mean age 32 years, 47 men, 95 women), correlating the findings on MRA with those found at the time of open surgical hip debridement to ascertain the prevalence of acetabular cysts and the association with underlying acetabular changes. Fifteen MRA's demonstrated features consistent with underlying acetabular cystic change. At the time of surgery, this was confirmed in eleven cases that demonstrated a full thickness articular chondral flap (carpet lesion) and an underlying acetabular cyst. The sensitivity, specificity, positive predictive value and negative predictive value of MRA in relation to acetabular cysts was 55%, 96.7%, 73.3% and 92.9% respectively. We believe acetabular cysts on MRA to be a significant finding. Such patients are likely to have an associated full thickness chondral lesion and features of early degenerative change, influencing outcome and prognosis. Our clinical practise has changed to reflect this finding. For those patients with cysts on MRA, we are less likely to offer open debridement and favour arthroscopic intervention followed by arthroplasty when symptoms dictate. We believe hip preservation surgeons should be aware of the significance of acetabular cysts and be prepared to adjust treatment options accordingly.
Femoroacetabular impingement causes pain in the hip in young adults and may predispose to the development of osteoarthritis. Genetic factors are important in the aetiology of osteoarthritis of the hip and may have a role in that of femoroacetabular impingement. We compared 96 siblings of 64 patients treated for primary impingement with a spouse control group of 77 individuals. All the subjects were screened clinically and radiologically using a standardised protocol for the presence of cam and pincer deformities and osteoarthritis. The siblings of those patients with a cam deformity had a relative risk of 2.8 of having the same deformity (66 of 160 siblings hips versus 23 of 154 control hips, p <
0.00001). The siblings of those patients with a pincer deformity had a relative risk of 2.0 of having the same deformity (43 of 116 sibling hips versus 29 of 154 control hips, p = 0.001). Bilateral deformity occurred more often in the siblings (42 of 96 siblings versus 13 of 77 control subjects, relative risk 2.6, p = 0.0002). The prevalence of clinical features in those hips with abnormal morphology was also greater in the sibling group compared with the control group (41 of 109 sibling hips versus 7 of 46 control hips, relative risk 2.5, p = 0.007). In 11 sibling hips there was grade-2 osteoarthritis according to Kellgren and Lawrence versus none in the control group (p = 0.002). Genetic influences are important in the aetiology of primary femoroacetabular impingement. This risk appears to be manifested through not only abnormal joint morphology, but also through other factors which may modulate progression of the disease.
We describe two cases of fracture of Corin Taper-Fit stems used for cement-in-cement revision of congenital dysplasia of the hip. Both prostheses were implanted in patients in their 50s, with high offsets (+7.5 mm and +3.5 mm), one with a large diameter (48 mm) head and one with a constrained acetabular component. Fracture of the stems took place at nine months and three years post-operatively following low-demand activity. Both fractures occurred at the most medial of the two stem introducer holes in the neck of the prosthesis, a design feature that is unique to the Taper-Fit stem. We would urge caution in the use of these particular stems for cement-in-cement revisions.
We have found poor mid-term results in a multisurgeon series of 94 Johnson-Elloy (Accord) total knee replacements. A total of 27 knees (29%) has required revision, in 26 for aseptic loosening. Only 18 (19%) remain in situ, and these give poor function, are painful and most show radiological evidence of early failure. At 12 to 13 years the survival rate is 43% (confidence interval 29 to 57) with failure requiring revision as the endpoint. Proximal migration of the femoral component is associated with considerable loss of bone stock. We believe that all patients who have this implant should be recalled for regular review in order to anticipate this problem.
We report catastrophic early failure of a cemented total hip replacement comprising a modular femoral component with a Zirconia ceramic head and an acetabular component of cross-linked ultra-high molecular-weight polyethylene (Hylamer). Between 1995 and 1999 we implanted 29 hips in 26 patients with a mean age of 49.2 years. Survivorship analysis in this group revealed a failure rate of 67.6% at five years. All hips which failed did so because of aseptic loosening with progressive osteolysis or radiolucencies. We therefore recommend early and regular review of all patients with this combination of implants and early revision surgery in order to avoid massive bone loss.