Abstract
Hip resurfacing arthroplasty (HRA) in patients with a varus deformity of the femoral neck-shaft angle (NSA) is associated with poorer outcomes. Our experience has not reflected this. We examined the Oxford Hip Scores (OHS), Harris Hip Scores (HHS) and outcomes of patients with varus hips against a normal cohort to ascertain any significant difference.
We identified 179 patients. Measurement of the femoral neck-shaft angle was undertaken from antero-posterior radiographs pre-operatively. The mean NSA was 128.5 degrees (SD 6.3). Patients with a NSA of less than 122.2 were deemed varus and those above 134.8 valgus. These parameters were consistent with published anatomical studies.
The varus cohort consisted of 23 patients, mean NSA 118.7 (range 113.6-121.5), mean follow-up 49 months (range 13-74). Mean OHS and HHS were 16 and 93.5 respectively. Complications included 2 cases of trochanteric non-union; no femoral neck fractures, early failures or revisions. Normal cohort consisted of 125 patients, mean NSA 128 degrees, mean follow-up 41 months (range 6-76). The OHS and HSS were 18.8, 88.9 respectively. Complications included 5 trochanteric non-unions and 1 revision due to an acetabular fracture following a fall. Statistical analysis demonstrated no statistical difference between the cohorts OHS (p=0.583) or HHS (p=0.139).
Our experience in patients with a varus femoral neck has been positive. Our analysis has demonstrated no statistical difference in hip scores between the cohorts. We have not yet experienced any femoral neck fractures, which we believe is due to the use of the Ganz trochanteric flip and preservation of blood supply.