There is ongoing debate on the benefits of fixed versus mobile bearing Unicompartmental Knee Replacement (UKR). We report the results from a randomised controlled trial comparing fixed and mobile bearing of the same UKR prosthesis. Forty patients were randomized to receive identical femoral components and either a fixed or mobile bearing tibial component. At 6.5 years follow-up 37% of the mobile bearing design had been revised and 14% for the fixed bearing design. The main reasons for revision were pain and loosening. These results were compared with data from The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) that show a cumulative percent revision of 24.2% for the mobile bearing Preservation UKR at 6.5 years. All locally explanted mobile bearings were examined microscopically, and 83% demonstrated significant backside wear. Constraint on the undersurface of the bearing coupled with a congruent upper surface may have contributed to the excessive revision rate. This is the first randomised controlled trial examining mobile and fixed variations of the same UKR prosthesis and shows this design of UKR with the mobile bearing has an unacceptably high revision rate and patients with this knee design should be closely monitored.
The aim of this study was to compare a single-incision minimally invasive (MI) posterior approach with a standard posterior approach in a double-blind prospective randomised controlled trial. A pilot study was carried out to assess the efficacy of the MI approach. Primary total hip replacements meeting the inclusion criteria were randomised to either the MI approach or the standard posterior approach. Patients were blinded to allocation. Patients were scored by a blinded physiotherapist pre-operatively, at Day 2, 2 weeks and 6 weeks. The primary outcome measure was function, assessed using the Oxford hip score, SF-12 questionnaire, Iowa score, 6-minute walk test and the number of walking aids required after 2 and 6 weeks post-operatively. Secondary outcomes were complication rates, patient satisfaction, soft tissue trauma and radiographic analysis.Aim
Method
In conclusion we found significantly reduced wear for aluminumoxide heads compared to cobalt chrome heads which could be beneficial for young and active patients.
We have conducted a prospective, observational clinical trial of 34 patients with dual compartment osteoarthritis of the knee treated with a 2/3 Knee.
Exclusion criteria included obesity, inflammatory arthritis and a fixed flexion deformity >
10 degrees. Subjective outcome measures included Oxford Knee Scores (OKS) and EQ-5D Scores. RSA beads were implanted at surgery to detect loosening, micro-motion and prosthesis wear. Gait analysis was conducted at 1 year post op in a subgroup of patients.
The patients have recorded Significant improvement in their Oxford Knee Scores at 6 months (mean reduction all patients: 17.3, resurfaced 20). Early RSA results have not detected Significant migration to indicate early loosening. Gait analysis has shown that patients return to approximate normal rather than pre-operative gait.
It is essential that patients undergo primary patella resurfacing to prevent crepitus and associated anterior knee pain. A study comparing clinical outcomes of 2/3 Knee vs TKA is underway at our institution.
We treated 34 patients with recurrent dislocation of the hip with a constrained acetabular component. Roentgen stereophotogrammetric analysis was performed to assess migration of the prosthesis. The mean clinical follow-up was 3.0 years (2.2 to 4.8) and the radiological follow-up was 2.7 years (2.0 to 4.8). At the latest review six patients had died and none was lost to follow-up. There were four acetabular revisions, three for aseptic loosening and one for deep infection. Another acetabular component was radiologically loose with progressive radiolucent lines in all Gruen zones and was awaiting revision. The overall rate of aseptic loosening was 11.8% (4 of 34). Roentgen stereophotogrammetric analysis in the non-revised components confirmed migration of up to 1.06 mm of translation and 2.32° of rotation at 24 months. There was one case of dislocation and dissociation of the component in the same patient. Of the 34 patients, 33 (97.1%) had no further episodes of dislocation. The constrained acetabular component reported in our study was effective in all but one patient with instability of the hip, but the rate of aseptic loosening was higher than has been reported previously and requires further investigation.
Minimum follow-up was 3 years in group 1 and 1.5 years in group 2. There were 3 dislocations in group 1, and none in group 2. There were 2 re-operations in both groups. The relative improvement in WOMAC scores was significantly greater in group 2 at 3 months and 1 year (P<
0.05).
We carried out a blinded prospective randomised controlled trial comparing 2-octylcyanoacrylate (OCA), subcuticular suture (monocryl) and skin staples for skin closure following total hip and total knee arthroplasty. We included 102 hip replacements and 85 of the knee. OCA was associated with less wound discharge in the first 24 hours for both the hip and the knee. However, with total knee replacement there was a trend for a more prolonged wound discharge with OCA. With total hip replacement there was no significant difference between the groups for either early or late complications. Closure of the wound with skin staples was significantly faster than with OCA or suture. There was no significant difference in the length of stay in hospital, Hollander wound evaluation score (cosmesis) or patient satisfaction between the groups at six weeks for either hips or knees. We consider that skin staples are the skin closure of choice for both hip and knee replacements.
Patients were scored pre-operatively and followed up prospectively. The only special instruments required are two large curved Hohmann retractors and an angled cup introducer.
Forty-two percent of patients were male. Mean age was 68.9 years (42–90) and BMI 26 (14–39). Average operation time was 64.1 minutes and anaesthetic time 92.5 minutes. Mean fall in haemoglobin in the first 24 hours was 2.3g/dl. Mean incision length was 7.4cm. Follow-up was a minimum of one year (range 12–29 months). There was a highly statistically significant improvement in WOMAC and SF-36 scores at three and 12 months post-operatively (p<
0.0001). Early medical complications occurred in 12 patients, including two superficial infections, all of which resolved. There were no peri-prosthetic fractures and importantly, no dislocations. There were two re-operations: one revision for cup displacement and one washout for deep infection.
In our clinical series, over 30% of patients experienced paraesthesia and some experienced a burning dysaesthesia in the distribution of the LFCN.
In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.
The reported revision rate of total hip arthroplasties (THAs) due to wear and osteolysis is around 10% at 10 years. However, the actual rate is probably higher: the incidence of osteolysis is reported to be 10% to 45%. Apart from design improvements, improved or new materials and/or and combinations are important in reducing particle-induced osteolysis, especially in young and active patients. Wear reduction of up to 40% after inert gas sterilisation of polyethylene (PE) has been demonstrated, both in vitro and in vivo. An effective means of providing further increases in wear resistance is to cross-link PE extensively. Early clinical results of non-melt-annealed PE at three years showed wear reduction of up to 85% compared to inert gas radiation-sterilised PE. In hip joint simulator investigations, bearings with a ceramic ball-head articulating against a composite cup demonstrated wear rates similar to those of ceramic-ceramic bearings. The wear particles are benign. Clinical data collected over two years suggest no disadvantages compared to the standard articulation controls. The wear resistance of alumina-alumina articulation has been enhanced. In-vitro investigation demonstrated that even with a cup inclination of 60° the wear rate is not increased. The effect of micro-separation of the artificial joint is also minimised. Several prospective multi-centre alumina-alumina studies have shown no additional complications with this articulation. However, alumina is a brittle material with an inherent risk of fracture. The addition of 25% zirconia to alumina (ZTA) in the manufacturing process improves its fracture resistance, increasing its strength by more than 50%, while maintaining its other properties. The wear properties of ZTA are even better than that of alumina, especially in micro-separation articulation mode. Highly cross-linked and optimised PE and composite technology are promising concepts in address wear particle-induced osteolysis.