Infections in orthopaedic surgery are costly, debilitating complications. The search for new treatments and prevention strategies has led to the use of antibiotic-filled calcium sulfate (CaS) as a bone void filler that is both safe and effective. The purpose of this study was to examine the available data on the efficacy of this technology. A literature search was performed for studies that evaluated the use of antibiotic-loaded CaS cement in orthopaedics published between inception of the databases to 2017. Selected studies included randomized controlled trials (RCTs) and observational studies published in the English language that met the following criteria: 1) patients underwent an orthopaedic procedure; 2) CaS cement with an antibiotic was used; and 3) at least one of our outcomes were mentioned. Outcomes included resolution of infection, complications related to treatment, subsequent surgeries, overall infection rate, fracture union rate, clinical outcomes, and wound complications. A total of 17 studies were included.Purpose
Methods
A meta-analysis was performed to compare rate of SSI after application of chlorhexidine vs. iodine in total joint arthroplasty. Chlorhexidine had significantly lower odds of SSI. Surgical site infections (SSI) are a significant source of morbidity and mortality. The optimal preoperative skin preparation in lower extremity total joint arthroplasty (TJA) remains debatable between chlorhexidine and iodine-containing solutions. This meta-analysis sought compare SSI rates between chlorhexidine cloth application the night before surgery plus povidone-iodine-alcohol (povidone-iodine) solution at surgery or only povidone-iodine at surgery.Summary
Introduction
Because of the low cost and easy access, surgical video has become a popular method of acquiring surgical skills outside operating rooms without disrupting normal surgical flow. However, currently existing video systems all use a single point of view (POV). Some complex orthopedic procedures, such as joint replacement, require a level of accuracy in several dimensions. So single and fixed POV video may not be enough to provide all the necessary information for educational and training purposes. The aim of our project was to develop a novel multiple POV video system and evaluate its efficacy as an aid for learning joint replacement procedure compared with traditional method. Based on the videos of a hip resurfacing procedure performed by an expert orthopedic surgeon captured by 8 cameras fixed all around the operating table, we developed a novel multiple POV video system which enables users to autonomously switch between optimal viewpoints (Figure 1). 30 student doctors (undergraduate years 3–5 and naive to hip resurfacing procedure) were recruited and randomly allocated to 2 groups: experiment group and control group, and were assigned to learn the procedure using multiple or single POV video systems respectively. Before learning they were first asked to complete a multiple choicetest designed using a modified Delphi technique with the advice and feedback sought from 4 experienced orthopedic surgeons to test the participants' baseline knowledge of hip resurfacing procedure. After video learning, they were asked to answer the test again to verify their gained information and comprehension of the procedure, followed by a 5-point Likert-scale questionnaire to demonstrate their self-perception of confidence and satisfaction with the learning experience. The scores in the 2 tests and in the Likert-scale questionnaire were compared between 2 groups using Independent-Samples t-test (for normally distributed data) or Mann-Whitney U test (for non-normally distributed data). Statistical significance was set as p<0.05.Introduction
Materials and Methods
Patient Specific Instrumentation (PSI) has the potential to allow surgeons to perform procedures more accurately, at lower cost and faster than conventional instrumentation. However, studies using PSI have failed to convincingly demonstrate any of these benefits clinically. The influence of guide design on the accuracy of placement of PSI has received no attention within the literature. Our experience has suggested that surgeons gain greater benefit from PSI when undertaking procedures they are less familiar with. Lateral unicompartmental knee replacement (UKR) is relatively infrequently performed and may be an example of an operation for which PSI would be of benefit. We aimed to investigate the impact on accuracy of PSI with respect to the area of contact, the nature of the contact (smooth or studded guide surfaces) and the effect of increasing the number of contact points in different planes. A standard anatomy tibial Sawbone was selected for use in the study and a computed tomography scan obtained to facilitate the production of PSI. Nylon PSI guides were printed on the basis of a lateral UKR plan devised by an orthopaedic surgeon. A control PSI guide with similar dimensions to the cutting block of the Oxford Phase 3 UKR tibial guide was produced, contoured to the anterior tibial surface with multiple studs on the tibial contact surface. Variants of this guide were designed to assess the impact of design features on accuracy. These were: a studded guide with a 40% reduction in tibial contact area, a non-studded version of the control guide, the control guide with a shim to provide articular contact, a guide with an extension to allow distal referencing at the ankle and a guide with a distal extension and an articular shim. All guides were designed with an appendage that facilitated direct attachment to a navigation machine (figure 1). 36 volunteers were asked to place each guide on the tibia with reference to a 3D model of the operative plan. The order of placement was varied using a counterbalanced latin square design to limit the impact of the learning effect. The navigation machine recorded deviations from the plan in respect of proximal-distal and medial-lateral translations as well as rotation around all three axes. Statistical analysis was performed on the compound translational and rotational errors for each guide using ANOVA with Bonferroni correction with statistical significance at p<0.05.Introduction
Method
Stiffness after total knee arthroplasty is a common occurrence. Despite its prevalence, little is known as to which patients are at risk for poor range of motion after total knee arthroplasty. The purpose of this study was to determine the risk factors for manipulation under anesthesia (MUA) after total knee arthroplasty (TKA). Using a single institution registry, 160 patients who underwent a manipulation under anesthesia after total knee arthroplasty between 2007 and 2013 were retrospectively evaluated. Each patient was 1:1 matched by age, gender and laterality to a control group of 160 patients who did not require MUA after TKA. Risk factors for MUA were assessed, and included medical co-morbidities, BMI, prior operations, and preoperative range of motion.Introduction
Methods
Currently the debate continues in definitive fixation method for complex tibial plateau fractures. The aim of surgical management remains prevention of further damage to the articular cartilage, whilst avoiding iatrogenic risks - Low Risk Surgery (LRS). The purpose of this study was to determine the functional impact, clinical radiological outcome following tibial plateau fractures treated with either external fixation or internal fixation. 124 Schatzker IV-VI tibial plateau fractures were reviewed following surgical fixation. Fractures analysed included 24 type IV, 20 type V and 80 type VI tibial plateau fractures. The majority of Schatzker IV fractures were treated with internal fixation, but 67 of 80 Schatzker VI fractures were treated with the Ilizarov method. The average IOWA knee score, was 86 (16 to 100) and the average range of motion was 133 degrees (60 to 150). There were no differences between the circular fixator group and the internal fixation group in terms of range of motion or IOWA scores. There were comparable functional outcomes and complication rates between both groups. In summary patients with high energy tibial plateau fracture treated with internal or external fixation, have a good chance of achieving satisfactory long term knee function.
Between 1989 and 1992 102 knees adjudged suitable for Unicompartmental replacement (UKR) were randomised to receive either a St Georg Sled UKR or a Kinematic modular total knee replacement (TKR). The early results demonstrated that the UKR group had less complications, and more rapid rehabilitation. At 5 years there were equal failures but the UKR group had more excellent results and a greater range of movement. Despite this doubt persisted about whether these advantages would be maintained these cases have been followed regularly by a research nurse at 8, 10, 12 years. We now report the final outcome at 15 years. 43 patients (45 knees) have died with all their knees intact. Throughout the review period the Bristol Knee Scores (BKS) of the UKR group have been better and at 15 years 77% and 53% of the surviving UKRs and TKRs achieve an excellent score. 6 TKRs and 4 UKRs have failed during the 15 years of the review. The better early results with UKR are maintained at 15 years with no greater failure rate. The median BKS scores of the UKR group was 91.1 at five years and 92 at 15 years suggesting little functional deterioration in either the prosthesis or remainder of the joint. These results would seem to justify the increased use of UKR.Conclusion
We aimed to measure cerebral microemboli load during total hip [THA] and knee arthroplasty (TKA) using transcranial Doppler ultrasound (TCD) and to investigate whether cerebral embolic load influences neuropsychiatric outcome. The timing of the microemboli was also related to certain surgical activities to determine if a specific relationship exists and the presence of a patent foramen ovale was investigated. Patients undergoing primary THA and TKA underwent a battery of ten neuropsychiatric tests pre-operatively and at 6 weeks and 6 months post-operatively. Microembolic load was recorded using TCD onto VHS tape for subsequent analysis. Patent foramen ovale detection was performed using bolus intravenous injection of agitated saline followed by valsalva manoeuvre. The timing of specific surgical steps was recorded for each operation and embolic load calculated for that period. All patients were assessed for quality of life and orthopaedic outcome measures. 45 THA patients and 50 TKA patients were studied. Cerebral microembolisation occurred in 35% of all patients (10 THA patients and 19 TKA patients). Mean microembolic load was 2.8 per patient for THA and 3.76 per patient for TKA patients. PFO was detected in 29 patients overall. Insertion of the femoral component and deflation of the tourniquet were associated with a larger microembolic loads. Neuropsychiatric outcome was not affected by the low embolic loads. Quality of life and Orthopaedic outcome at 6 months was good. Cerebral microembolisation occurs in a significant proportion of patients during total hip and knee arthroplasty. The presence of a patent foramen ovale does not appear to influence the incidence of microembolisation or load. Specific surgical activities are associated with generating greater embolic loads and methods of avoiding these emboli such as venting the femur may minimise complications and optimise outcomes. Neuropsychiatric outcomes do not seem to be affected by microembolisation of the brain during total joint arthroplasty.Results
Conclusion
Unicompartmental knee replacements (UKR) converted to total knee replacements (TKR) have often been viewed with scepticism because of the perceived difficulty of the revision and because revision procedures generally do less well than primaries. This is a prospective review of TKRs converted from a UKR between 1982 and 2000. We present the survivorship of a 77 patient cohort and the clinical results of 35 patients. All information was recorded at the time of surgery onto a database and patients have been regularly reviewed since.Background
Methods
The Bristol Knee Group has prospectively followed the results of over 500 isolated patellofemoral arthroplasties. Initial experience with the Lubinus prosthesis was disappointing. The main causes of failure were mal-tracking and instability leading to excessive polythene button wear and disease progression in the tibio femoral joint. This experience resulted in the design of a new prosthesis to correct the tracking problems and improve the wear. We have now performed over 425 Avon arthroplasties with a maximum follow-up of 9 years. Survivorship at 5 years and the functional outcome have been reported with 95.8% survivorship, and improved function with Oxford score from 18 to 39 points out of 48. There have been 14 cases with mal-tracking (3%). Several of these cases have required proximal or distal realignment with the Elmslie or Insall procedures. Two knees with patella alta required distalisation of the tibial tubercle. Symptomatic progression of the arthritic disease in the medial or lateral tibio-femoral compartments has occurred in 28 cases (7%) causing recurrent joint pain. Radiographic follow-up has shown a higher rate of disease progression emphasising the importance of careful assessment of patients prior to operation. We have investigated 8 cases of persistent unexplained pain. Analysis of these cases suggests 3 possible causes. An extended anterior cut leading to overstuffing, insufficient external rotation and over sizing of the femoral component leading to medial or lateral retinacular impingement. Six of these cases have been successfully treated by revision of the femoral component leading to dramatic resolution of the symptoms.Introduction
Results