Since long-term outcome of teres major tendon transfer surgery
for irreparable posterosuperior rotator cuff (RC) tears is largely
unknown, the primary aim of this study was to evaluate the long-term
outcome of the teres major transfer. We also aimed to report on
the results of a cohort of patients with a similar indication for
surgery that underwent a latissimus dorsi tendon transfer. In this prospective cohort study, we reported on the long-term
results of 20 consecutive patients with a teres major tendon transfer
for irreparable massive posterosuperior RC tears. Additionally,
we reported on the results of the latissimus dorsi tendon transfer
(n = 19). The mean age was 60 years (47 to 77). Outcomes included
the Constant score (CS), and pain at rest and during movement using
the Visual Analogue Scale (VAS).Aims
Patients and Methods
Surgical repair of posterosuperior rotator cuff
tears has a poorer outcome and a higher rate of failure compared
with repairs of supraspinatus tears. In this prospective cohort
study 28 consecutive patients with an irreparable posterosuperior
rotator cuff tear after failed conservative or surgical treatment
underwent teres major tendon transfer. Their mean age was 60 years
(48 to 71) and the mean follow-up was 25 months (12 to 80). The
mean active abduction improved from 79° (0° to 150°) pre-operatively
to 105° (20° to 180°) post-operatively (p = 0.011). The mean active
external rotation in 90° abduction improved from 25° (0° to 70°)
pre-operatively to 55° (0° to 90°) post-operatively (p <
0.001).
The mean Constant score improved from 43 (18 to 78) pre-operatively
to 65 (30 to 86) post-operatively (p <
0.001). The median post-operative
VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to
5 (0 to 56) post-operatively (p <
0.001). In conclusion, teres major transfer effectively restores function
and relieves pain in patients with irreparable posterosuperior rotator
cuff tears and leads to an overall clinical improvement in a relatively
young and active patient group with limited treatment options. Cite this article:
Quality of rotator cuff repair did not alter PM outcome. PM did not occur more frequently in hemi-artho-plasty compared to total shoulder arthroplasty. A more upward oriented glenoid was observed in the PMearly and PMlate groups.
Neonatal brachial plexus palsy (NBPP) is frequently associated with internal rotation contractures of the shoulder as a result of muscle imbalance due to muscle fattening and/or fibrosis which favour the internal rotation of the shoulder. Botulinum toxin A (BTX-A) injection in the subscapularis (SC) muscle could weaken the SC and thereby restore muscle balance. The purpose of this study was to assess the effect of intra muscular injection of BTX-A in the SC on the passive external rotation and the need for external rotation surgery in NBPP patients after BTX-A injection. A prospective comparative study was performed with 93 patients with progressive internal rotation contractures. Al patients underwent an MRI to determine the percentage of the humeral head anterior to the glenoid (PHHA) and glenoid version. Patients younger than 48 months old and with a minimum deformity (PHHA>
=35%) or moderate deformity (PHHA<
35%) were included. Patients with a severe deformity or complete posterior dislocation were excluded. Fifteen consecutive patients were injected with BTX-A (2 U/kg body weight, botox®) at two sites of the SC of the affected shoulder immediately after the MRI under general anesthesia. Seventy eight patients were included as a control group before the new BTX-A treatment was introduced. The passive external rotation was measured pre-MRI and at follow-up. The indication for external rotation surgery was determined after the MRI was performed. No adverse events were observed. Pre-MRI, the mean passive external rotation in adduction in the BTX-A group was −5° (SE 8°) and in the control group 3° (SE 3°). In the BTX-A group, the mean passive external rotation in adduction increased with 53° (95% CI 31°–74°, p<
0.001) compared to the control group. After stratification the beneficial effect of BTX-A was observed in patients with a minimum deformity (54°, 95% CI 37°–71°, p<
0.001), but this was not significant in patients with a moderate deformity (47°, 95% CI −20°−115°, p=0.13) compared to the control group. The patients in the BTX-A group were less frequently indicated for external rotation surgery compared the control group (27% vs. 89%, p<
0.001). The maximum effect of BTX-A injection was observed at a mean follow-up of 3 months (SE 1). The control group was followed for a mean of 7 months (SE 0.4) to observe the natural history of internal rotation contractures. The groups were comparable regarding type of lesion, primary treatment, age, PHHA, glenoid version and passive external rotation pre-MRI (p 0.09–0.74). BTX-A injections in the SC of NBPP patients reduce internal rotation contractures. This effect was mainly observed in patients with a minimum glenohumeral deformity. Restoration of muscle balance could prevent further glenohumeral deformation and could prevent external rotation surgery.
A changed kinematic elbow axis can cause early loosening of elbow endoprostheses and can decrease the functional outcome. Therefore, these prostheses and their alignment tools are designed to reconstruct normal joint kinematics. We investigated whether it is possible to reconstruct the pre-operative kinematic axis of the elbow when an iBP™ elbow endoprosthesis (Biomet) has been placed. The calibrated Flock of Birds® electromagnetic tracking device registered controlled passive elbow flexion of ten embalmed upper extremities. The pre-operative kinematic elbow axes were established using helical axes. Results were expressed in the humeral coordinate system defined by the glenohumeral joint rotation centre and the lateral and medial epicondyle of the humerus. The glenohumeral joint rotation centre was determined using a regression method. The senior author implanted the iBP™ elbow endoprosthesis using standard instrumentation for humeral component alignment. The post-operative kinematic axes were then calculated. A Student’s t-test was performed to compare the pre- and post-operative axes. No significant differences were found in the direction of the kinematic elbow axes before and after surgery, indicating no alteration in the valgus/varus angle or change in longitudinal rotation of the ulna with respect to the humerus. However, the axis was located significantly more distal (mean difference 7.0 mm, p = 0.004) after surgery. The ventral-dorsal location of the kinematic axis was not significantly different (p = 0.748) after surgery, but there was some variation in individual axes. The iBP™ Elbow System enables the reconstruction of the direction of the pre-operative kinematic elbow axis. While the exact position of the pre-operative axis could not be reproduced in vitro, the kinematic axis of the elbow is expected to be less distal in vivo as a result of the extensive destruction of the rheumatoid elbow. Individually adjustable alignment tools might enable more precise reconstruction.
The incidence of loosening of a cemented glenoid component in total shoulder arthroplasty, detected by means of radiolucent lines or positional shift of the component on true antero-posterior radiographs, has been reported to be between 0% to 44%. These numbers depend on the criteria used for loosening and on the length of follow-up. Radiolucent lines are however difficult to detect and to interpret, because of the mobility of the shoulder girdle and the obliquity of the glenoid, which hinder standardisation of radiographs. After review of radiolucencies around cemented glenoid components with a mean follow-up of 5. 3 years in 48 patients we found progressive changes to be present predominantly at the inferior pole of the component. This may hold a clue for the mechanism behind loosening of this implant. Since loosening is generally defined as a complete radiolucent line around the glenoid component and is difficult to assess as a result of the oblique orientation of the glenoid, an underestimation of the loosening rate using radiological data was suspected. Therefore a pilot study using Roentgen Stereophotogrammatric Analysis (RSA) was performed. In five patients an additional analysis of glenoid component loosening using digital Roentgen Stereophotogrammetric Analysis (RSA) was performed. The relative motion of the glenoid component with respect to the scapula was assessed and the length of this translation vector was used to represent migration. Loosening was defined as a migration of the component, exceeding the pessimistic estimate of the accuracy of RSA 0. 3 mm for this study. After three years of follow-up, three out of five glenoid components had loosened (1. 2 – 5. 5 mm migration). In only one patient with a gross loosened glenoid, the radiological signs were consistent with the RSA findings. It was concluded that when traditional radiographs are used for assessment of early loosening, the loosening rate is underestimated. We recommend that RSA be used for this.
The radiographs of sixty-four patients with seventy humeral head replacements were reviewed for signs of stress shielding. Forty-nine were implanted for rheumatoid arthritis, twenty-one for osteoarthritis. The radiographic follow-up averaged 5. 3 years. Measurements of cortex thickness were performed in four regions along the stem of the implant and the differences between the post-operative radiograph and radiograph at follow-up were calculated. The size of the stem in relation to the diameter of the humerus was calculated using validated measures, resulting in the relative stem size. A reduction of 1.6 millimeters or more was considered to be a significant reduction, because this lay outside of the calculated 95% normal range for the group as a whole. In six patients (9%) a significant reduction, in cortical thickness was observed in the proximal lateral region of the humeral stem. Five of these had rheumatoid arthritis and one osteoarthritis. In the stress shielding group the relative stem size was found to be significantly higher (p=0. 013) than in the non-stress shielding group (0. 58 versus 0. 48). Osteoporosis, especially present in rheumatoid arthritis, could well be a risk factor. It was concluded that stress shielding is a long-term complication of shoulder arthroplasty and that the relative stem size is an important factor in its genesis. These resorptive processes may lead to a higher risk of failure of the implant and gives an increased risk for mid-stem fractures, due to cantilever loading. It is also desirable to preserve the proximal bone stock, considering the difficulties that arise when, for whatever reason, revision of the implant is necessary.
The incidence of loosening of a cemented glenoid componentin total shoulder arthroplasty, detected by means of radiolucent lines or positional shift of the component on true anteroposterior radiographs, has been reported to be between 0% and 44%. Radiolucent lines are, however, difficult to detect and to interpret because of the mobility of the shoulder girdle and the obliquity of the glenoid which hinder standardisation of radiographs. We examined radiolucencies around cemented glenoid components in 48 patients, with a mean follow-up of 5.3 years, and found progressive changes to be present predominantly at the inferior pole of the component. This may hold a clue for the mechanism of loosening of this implant. In five patients we performed an additional analysis of loosening of the glenoid component using digital roentgen stereophotogrammetric analysis (RSA). After three years, three of the five implants had loosened (migration 1.2 to 5.5 mm). In only one, with gross loosening, were the radiological signs consistent with the RSA findings. When traditional radiographs are used for assessment, the rate of early loosening is underestimated. We recommend that RSA be used for this.