PATTERNS OF GLENOID COMPONENT LOOSENING



Abstract

The incidence of loosening of a cemented glenoid component in total shoulder arthroplasty, detected by means of radiolucent lines or positional shift of the component on true antero-posterior radiographs, has been reported to be between 0% to 44%. These numbers depend on the criteria used for loosening and on the length of follow-up. Radiolucent lines are however difficult to detect and to interpret, because of the mobility of the shoulder girdle and the obliquity of the glenoid, which hinder standardisation of radiographs. After review of radiolucencies around cemented glenoid components with a mean follow-up of 5. 3 years in 48 patients we found progressive changes to be present predominantly at the inferior pole of the component. This may hold a clue for the mechanism behind loosening of this implant. Since loosening is generally defined as a complete radiolucent line around the glenoid component and is difficult to assess as a result of the oblique orientation of the glenoid, an underestimation of the loosening rate using radiological data was suspected. Therefore a pilot study using Roentgen Stereophotogrammatric Analysis (RSA) was performed.

In five patients an additional analysis of glenoid component loosening using digital Roentgen Stereophotogrammetric Analysis (RSA) was performed. The relative motion of the glenoid component with respect to the scapula was assessed and the length of this translation vector was used to represent migration. Loosening was defined as a migration of the component, exceeding the pessimistic estimate of the accuracy of RSA 0. 3 mm for this study. After three years of follow-up, three out of five glenoid components had loosened (1. 2 – 5. 5 mm migration). In only one patient with a gross loosened glenoid, the radiological signs were consistent with the RSA findings. It was concluded that when traditional radiographs are used for assessment of early loosening, the loosening rate is underestimated. We recommend that RSA be used for this.


Address for correspondence:Department of Orthopaedics, Leiden University Medical Center, PO Box 9600, 2300 RC Leiden, The Netherlands E-mail: j.nagels@lumc.nl