Couture A Davies J Chapleau J Laflamme G Sandman E Rouleau D
Full Access

Radial head fractures are relatively common, representing approximately one-third of all elbow fractures. Outcomes are generally inversely proportional to the amount of force involved in the mechanism of injury, with simple fractures doing better than more comminuted ones. However, the prognosis for these fractures may also be influenced by associated injuries and patient-related factors (age, body index mass, gender, tobacco habit, etc.) The purpose of this study is to evaluate which factors will affect range of motion and function in partial radial head fractures. The hypothesis is that conservative treatment yields better outcomes.

This retrospective comparative cohort study included 43 adult volunteers with partial radial head fracture, a minimum one-year follow up, separated into a surgical and non-surgical group. Risk factors were: associated injury, heterotopic ossification, worker's compensation, and proximal radio-ulnar joint implication. Outcomes included radiographic range of motion measurement, demographic data, and quality of life questionnaires (PREE, Q-DASH, MEPS).

Mean follow up was 3.5 years (1–7 years). Thirty patients (70%) had associated injuries with decreased elbow extension (−11°, p=0.004) and total range of motion (−14°, p=0.002) compared to the other group. Heterotopic ossification was associated with decreased elbow flexion (−9°, p=0.001) and fractures involved the proximal radio-ulnar joint in 88% of patients. Only worker's compensation was associated with worse scores. There was no difference in terms of function and outcome between patients treated nonsurgically or surgically.

We found that associated injuries, worker's compensation and the presence of heterotopic ossification were the only factors correlated with a worse prognosis in this cohort of patients. Given these results, the authors reiterate the importance of being vigilant to associated injuries.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 54 - 54
1 Dec 2016
Yin D Jun J Delisle J Banica A Senay A Laflamme G Ranger P Fernandes J
Full Access

Blood loss is a major concern in total knee arthroplasty (TKA) along with postoperative knee function. The present study explores the impact of tourniquet and closed-suction drains on blood loss as well as knee function in TKA.

A prospective clinical trial was conducted on 111 patients admitted for TKA. Subjects were divided into three groups based on duration of tourniquet use (T+: whole-course tourniquet, T-: cementation only tourniquet) and usage of closed-suction drain (D+: drain use, D-: no drain). Thirty-six subjects were included in group T+D+, 42 in T-D+ and 33 in T-D-. Data from study population was analysed for pre and post-operative hemoglobin level (Hb), perioperative and total blood loss, blood transfusion rates, knee range of motion (ROM), and pain level assessment. Direct and indirect costs associated to nursing time and drains were calculated. Results are presented in mean ± SD.

No statistically significant differences were observed among the three groups (T+D+, T-D+ and T-D-) concerning total blood lost (calculated using Gross' formula), Hb levels over the first six postoperative weeks, blood transfusion rates and intra-articular hematomas. Intraoperative bleeding was significantly reduced in T+ subjects compared to T- subjects (100 ± 88 mL vs. 279 ± 235 mL respectively, p < 0.001), yet length of surgery was unaffected by the different tourniquet inflation strategies. Hidden blood loss was lower in D+ subjects compared to D- subjects (1161 ± 554 mL vs. 1667 ± 554 mL respectively, p < 0.001), but it was compensated by the blood loss in the drains. Early post operative ROM (flexion: 79.1 ± 14.8°, extension: −5.0 ± 6.7°) was superior in group T-D- compared to group T+D+ (flexion: 71.9 ± 17.1°, p = 0.071°; extension: −9.9 ± 6.4°, p = 0.004). Nevertheless, ROM six weeks postoperative was not statistically different between groups (flexion: 114.0 ± 13.3°, extension: 0.4 ± 5.2°). Patient-reported postoperative pain was also similar in all groups. Nursing time dedicated to drain management was 30 min/patient (330h total for 660 patients/year). Total costs related to drains were $31.92CAD/patient ($21,067CAD total for 660 patients/year).

Our results suggest that whole-course tourniquet and closed-suction drain use in TKA do not yield beneficial results in total blood loss, blood transfusion rates, complication rates and knee rehabilitation. Their clinical relevance in TKA is questionable. Moreover, nursing time and costs related to drains should have been allocated elsewhere in patient care.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 77 - 77
1 Dec 2016
Bellemare M Delisle J Troyanov Y Perreault S Senay A Banica A Beaumont P Giroux M Jodoin A Laflamme G Leduc S MacThiong J Malo M Maurais G Nguyen H Parent S Ranger P Rouleau D Fernandes J
Full Access

Treat to target is the use of a physiologic marker as a monitor of effectiveness or compliance to an intervention. A recent example has been the progressive use of CTX-1 (Marker of osteoclastic activity) as a surrogate of bone resorptive activity in osteoporosis treatment. CTX-1 levels were demonstrated to be inversely related to drug efficacy in the suppression of bone resorption. As far as fragility fractures are concerned, no reference value of CTX-1 for any index fracture sites was found in the literature. In order to prevent subsequent fractures, efforts to better manage this chronic disease are to be explored. The main objective of this study was to compare and validate the use of serum CTX-1 to the perceived compliance to treatment.

Five hundred and forty three patients (men and women) 40 years of age or older who had been treated for a fragility fracture were enrolled. The purpose of this study was to correlate the measurement of CTX-1 with the perceived compliance to treatment of patients at the time of fracture and at six, 12 and 18 months after initiation of treatment. Our secondary objectives were to evaluate two different CTX-1 suppression target levels (CTX-1< 0.3 ng/mL and CTX-1<0.2 ng/mL), to determine CTX-1 values according to fracture sites, and to explore the profile of patients with subsequent fractures.

Considering index fractures, compliant patients under treatment at baseline had lower CTX-1 levels than non-compliant patients (p=0.052). Patients who were compliant to treatment at six, 12 and 18 months also had lower CTX-1 levels than non-compliant patients (p=0.000). When index fractures were divided into fracture sites, regardless of CTX-1 suppression target level (i.e. CTX-1< 0.3 or 0.2 ng/mL), significant CTX-1 suppression was observed in non-hip and non-vertebral (NHNV) fractures at six, 12 and 18 months (p0.05). No clinically relevant difference was observed between the profile of patients with and without subsequent fractures.

The correlation between serum CTX-1 at the time of fracture and at six, 12, 18 months and the perceived compliance to treatment was validated for NHNV fractures supporting the concept of the available treatments and their effects on bone remodeling for this type of fracture. The correlation was not validated for hip neither for vertebral fracture. There was no correlation between CTX-1 levels and subsequent fracture risk.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 53 - 53
1 Dec 2016
Senay A Benderdour M Laflamme G Ranger P Shi Q Delisle J Fernandes J
Full Access

Total joint arthroplasty has proven to be efficient to relieve pain and regain mobility. In fact, most patients undergoing a total knee arthroplasty (TKA) are satisfied with their surgery (80 to 90%), yet 4 to 7% still complain of unexplainable pain and stiffness. Several authors have proposed that reactivity to the implant could explain this phenomenon. Still, no strong evidence supports this theory as of today. We aimed to determine the prevalence of metal and cement hypersensitivity in a cohort of patients with unexplained pain and stiffness after TKA.

We retrieved data for a group of patients presenting unexplained pain and stiffness. We excluded all other potential known causes of pain. All patients were tested with a Lymphocyte Transformation Test from whole blood taps. We analysed data of hypersensitivity to metals (alloy particles of titanium and cobalt, aluminum, cobalt, nickel, zirconium, vanadium, molybdenum, cobalt, chromium and iron) and PMMA cement (bone cement monomer and particles).

Fifty-three patients underwent a LTT for unexplained pain and stiffness after total knee arthroplasty between May 2012 and May 2015. The cohort consisted of 26 men and 27 women with a mean age of 66.3(±8.0) years. Six patients had no hypersensitivity (11.3%), leaving 88.7% of the cohort with hypersensitivity to metal and/or cement. Almost half the cohort of patients tested for PMMA was hypersensitive to cement (44.0%). The most common metal hypersensitivity was nickel (69.8%). Twelve patients presented sensitivity to only one metal (22.6%), whereas 35 patients were hypersensitive to more than one metal (66.0%). Eleven patients had revision surgery with a hypoallergenic prosthesis. Patients reported a significant diminution of pain as well as better knee function compared to preoperative status as early as 6 weeks postop, although some reported residual stiffness.

The results of this study suggest that metal and/or cement hypersensitivity could play a role in cases of total knee arthroplasty with unexplained pain and stiffness. Randomised controlled clinical trials on the subject will be initiated by our team to further investigate this phenomenon.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 57 - 57
1 Sep 2012
Sandman E Canet F Petit Y Laflamme G Rouleau DM
Full Access

Purpose

The measurement of radial head translation about the capitellum (in percent): the radio-capitellum ratio (RCR) has proven to have excellent inter- and intra-observer reliabilities when measuring the RCR on a lateral radiological view of elbows at 90° of flexion and in the neutral position of the forearm. However, in the clinical setting, radiographs may be taken with the elbow in different positions. However, the purpose was to validate the RCR measurement method on elbows in different positions in flexion-extension and in different positions of the forearm in pronation-supination.

Method

Fifty-one healthy volunteers were recruited to evaluate the RCR in different elbow positions. Lateral elbow radiographs were taken with the elbow in different magnitude of ROM: maximal extension, maximal flexion, elbow at 90° and forearm in neutral, elbow at 90° and forearm in supination and elbow at 90° and forearm in pronation. The measurements of the RCR were done using the software SliceOmatic. ANOVA and paired T-test were used to assess the difference of the RCR depending on the position of the elbow and of the forearm. Pearson coefficients were calculated to obtain the correlation between the RCR in each different position.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 127 - 127
1 Sep 2012
Chémaly O Laflamme G Rouleau DM
Full Access

Purpose

The ideal timing for a Total Hip Arthroplasty (THA) remains a highly controversial topic in the treatment of displaced acetabular fractures in the elderly with damage to the articular surface of the acetabulum or femoral head. Acute THA offers early rehabilitation but a high incidence of heterotopic ossification has been reported. Its incidence and consequences on the patient's function are not clear.

The goal of this study is to compare the incidence of heterotopic ossification following acute THA of acetabular fractures compared to delayed THA, and to evaluate its functional effects on the patient.

Method

In this retrospective consecutive case series of acetabular fractures; 20 patients were treated with acute THA and 20 patients were treated with delayed THA after failed conservative or surgical treatment. The incidence of heterotopic ossification (using Brooker's classification) was obtained and functional outcomes were evaluated using SF-12, WOMAC, Harris Hip Score surveys.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 106 - 106
1 Mar 2008
Laflamme G Berry G Gagnon S Beaumont P
Full Access

Although new locking plates allows for secure fixation of osteoporotic fractures in the proximal humerus, extensive soft tissue dissection is needed for their insertion. We report on a prospective clinical trial of the first thirty patients treated with plating of the proximal humerus though a minimally invasive percutaneous approach. All fractures healed within the first 6 months with no avascular necrosis or axillary nerve injury. At the latest follow-up, the median Constant score was sixty-eight and the mean DASH score was twenty-seven. This study suggests that percutaneous plating can be a safe and effective method of fixation.

To evaluate the safety and efficacy of minimally invasive plating of the proximal humerus using validated disease-specific measures.

Percutaneous insertion of a locking proximal humerus plate is safe and produces good early functional and radiologic outcomes.

Plate fixation of the proximal humerus fractures may now be more desirable with the use of a biological approach by limiting surgical insult and allowing accelerated rehabilitation.

All fractures healed within the first six months with no loss of correction. Two reoperations were needed to remove intra-articular screws placed too long. No infection or avascular necrosis were seen. At the lastest follow-up, the median Constant score was sixty-eight points, with an age ajusted score of seventy-six. The mean DASH score was twenty-seven points. Only age was independantly predictive of both the Constant and DASH functional scores.

During a period of one year, thirty patients were operated with use of the LCP proximal humerus plate (Synthes) through a 3cm lateral deltoid splitting approach and a second 2 cm incision at the deltoid insertion. The axillary nerve was palped and easily protected during insertion. Only two-part (N=22) and three-part impacted valgus type (N=8) were included in this study since they can be reduced indirectly thru this percutaneous technique. The average follow-up was thirteen months (eight to twenty months). All patients had the Constant and DASH evaluations.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 132 - 132
1 Mar 2008
Kim P Dunbar M Laflamme G Conway A Hrushowy H
Full Access

Purpose: A multicenter prospective evaluation of the Conserve Plus resurfacing implant (Wright Medical Technology) was undertaken to assess clinical and radiographic outcomes as well as ion levels. This study focuses on the serum, erythrocyte and urinary levels of cobalt and chromium in those patients undergoing hip resurfacing arthroplasty.

Methods: A subset of patients enrolled in a multicenter trial to assess hip resurfacing arthroplasty had serum, erythrocyte and urinary cobalt and chromium levels measured. Levels were assessed preoperatively, then at three months, six months then yearly thereafter. Clinical outcome measurements were performed with WOMAC and Rand questionnaires.

Results: Fifty-four out of 124 patients enrolled in the overall study had cobalt and chromium ion assessments performed. During the first year there was an increase in serum cobalt levels from 1.4 ug/l at 3 months to 2.4 ug/l at one year. Serum chromium levels increased from 1.4 ug/l at 3 months to 3.5 ug/l at one year. Erythrocyte cobalt levels increased from 0.8 ug/l at 3 months to 1.4 ug/l at one year. Erythrocyte chromium levels decreased from 1.5 ug/l at 3 months to 1.4 ug/l at one year. Urinary levels for cobalt increased from 12.7 ug/l at 3 months to 13.8 ug/l at one year. Urinary chromium levels rose from 4.0 ug/l at 3 months to 5.1 ug/l at one year.

Conclusions: Increasing ion levels were seen during the first year post hip resurfacing arthroplasty. Clinical outcomes demonstrate predictable improvements in pain and function consistent with hip replacement surgery. Resurfacing arthroplasty is a viable option to total hip arthroplasty for younger active patients. The clinical significance of increased cobalt and chromium ions remains unknown. Funding: Commerical funding Funding Parties: Wright Medical Technology Inc.