Advertisement for orthosearch.org.uk
Results 1 - 20 of 32
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 38 - 38
1 Dec 2022
Kim J Alraiyes T Sheth U Nam D
Full Access

Thoracic hyperkyphosis (TH – Cobb angle >40°) is correlated with rotator cuff arthropathy and associated with anterior tilting and protraction of scapula, impacting the glenoid orientation and the surrounding musculature. Reverse total shoulder arthroplasty (RTSA) is a reliable surgical treatment for patients with rotator cuff arthropathy and recent literature suggests that patients with TH may have comparable range of motion after RTSA. However, there exists no study reporting the possible link between patient-reported outcomes, humeral retroversion and TH after RTSA. While the risk of post-operative complications such as instability, hardware loosening, scapular notching, and prosthetic infection are low, we hypothesize that it is critical to optimize the biomechanical parameters through proper implant positioning and understanding patient-specific scapular and thoracic anatomy to improve surgical outcomes in this subset of patients with TH.

Patients treated with primary RTSA at an academic hospital in 2018 were reviewed for a two-year follow-up. Exclusion criteria were as follows: no pre-existing chest radiographs for Cobb angle measurement, change in post-operative functional status as a result of trauma or medical comorbidities, and missing component placement and parameter information in the operative note. As most patients did not have a pre-operative chest radiograph, only seven patients with a Cobb angle equal to or greater than 40° were eligible. Chart reviews were completed to determine indications for RTSA, hardware positioning parameters such as inferior tilting, humeral stem retroversion, glenosphere size/location, and baseplate size. Clinical data following surgery included review of radiographs and complications. Follow-up in all patients were to a period of two years. The American Shoulder and Elbow Surgeons (ASES) Shoulder Score was used for patient-reported functional and pain outcomes.

The average age of the patients at the time of RTSA was 71 years old, with six female patients and one male patient. The indication for RTSA was primarily rotator cuff arthropathy. Possible correlation between Cobb angle and humeral retroversion was noted, whereby, Cobb angle greater than 40° matched with humeral retroversion greater than 30°, and resulted in significantly higher ASES scores. Two patients with mean Cobb angle of 50° and mean humeral retroversion 37.5° had mean ASES scores of 92.5. Five patients who received mean humeral retroversion of 30° had mean lower ASES scores of 63.7 (p < 0 .05). There was no significant correlation with glenosphere size or position, baseplate size, degree of inferior tilting or lateralization.

Patient-reported outcomes have not been reported in RTSA patients with TH. In this case series, we observed that humeral stem retroversion greater than 30° may be correlated with less post-operative pain and greater patient satisfaction in patients with TH. Further clinical studies are needed to understanding the biomechanical relationship between RTSA, humeral retroversion and TH to optimize patient outcomes.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 30 - 30
1 Apr 2018
Choi W Oh S Kim J Baek S Kim S Lee Y Hwang D
Full Access

Objective

This paper aims to analyze the kinetics of the over-ground wheel-type body weight supporting system (BWS); tendency changes of low extremity joint moment (hip, knee, ankle), 3 axis accelerations of a trunk, cadence and gait velocity as weight bearing level changes.

Method

15 subjects (11 males, 4 females, age:23.63.5, height:170.65.1cm, weight:69.0210.75kg) who had no history of surgery participated. 6 levels (0%, 10%, 20%, 30%, 40% and 50%) of BWS were given to subjects at self-selected gait velocity and kinetic data was calculated using a motion capture system, Vicon® (Vicon, UK).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 40 - 40
1 Apr 2018
Kim J Lee D Choi J Ro D Lee M Han H
Full Access

Purpose

Management and outcomes of fungal periprosthetic joint infection (PJI) remain unclear due to its rarity. Although two-stage exchange arthroplasty is considered a treatment of choice for its chronic features, there is no consensus for local use of antifungal agent at the 1st stage surgery. The purpose of this study was to evaluate the efficacy of antifungal-impregnated cement spacer in two-stage exchange arthroplasty against chronic fungal PJIs after total knee arthroplasty (TKA).

Methods

Nine patients who were diagnosed and treated for chronic fungal PJIs after TKA in a single center from January 2001 to December 2016 were enrolled. Two-stage exchange arthroplasty was performed. During the 1st stage resection arthroplasty, amphotericin-impregnated cement spacer was inserted for all patients. Systemic antifungal medication was used during the interval between two stage operations. Patients were followed up for more than 2 years after exchange arthroplasty and their medical records were reviewed.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 111 - 111
1 Mar 2017
Kim J Jeong H Lee S Kim H Yoo J
Full Access

Clinical and radiological results of total hip arthroplasty (THA) using proximally coated single wedge (PSW) cementless stems are generally excellent. The geometry of cementless stems and the morphology of proximal femurs (Dorr types) provide optimal fit for primary stability and secondary biologic fixation. Because the geometry of PSW shape is designed to be engaged at the metaphysis, cementless PSW stem is not traditionally recommended to Dorr type C femurs with concerns of inadequate implant-host bone contact and the risk of femoral fracture. Nevertheless, previous studies on PSW cementless stems have not examined long-term survivorship according to Dorr types of femur. Paucity of a long-term comparative study makes it difficult to know whether the PSW stem plays a role in Dorr type C femurs or not. We postulated that the PSW stem could achieve stable fixation without increased risk of femoral fracture even in Dorr type C femurs, and demonstrate acceptable long-term results. The aim of this study was to investigate differences of clinical and radiological outcomes of THA using PSW stem according to proximal femoral geometry (Dorr types) in more than a 10-year follow-up.

Three hundred and seven primary THA in 247 patients, which was performed with use of a single-designed PSW stem from 1997 to 2003 and was followed up for over 10 years, were included in this retrospective study. According to Dorr's criteria, 89 femora were classified as Type A, 156 as Type B, and 62 as Type C. The patients' mean age at operation was 43.2 years (range, 18.4 – 69.6 years). They were followed-up for an average of 13.2 years (the range, 10.0 – 17.3 years). All of the hips were evaluated clinically and radiologically with special attention to the occurrence of implant loosening and periprosthetic femoral fracture.

The mean preoperative Harris hip score (50.4±20.6 points) improved significantly to 95.6±9.0 points at the final follow-ups. The improvements were observed regardless of Dorr types (p<0.001 in all 3 groups). The incidence of thigh pain (p=0.704) was not significantly different among groups. Implant survivorship was 100% in all 3 groups. None of the stems were loosened or revised. No significant differences were observed in osteolysis (p=0.492), pedestal formation (p=0.323), or cortical hypertrophy (p=0.169) among the groups [Fig. 1]. Radiolucent lines less than 2mm in thickness in Gruen zone 4 were observed more in Dorr type C femora than in Dorr type A or B (p=0.003) [Fig. 2]. Spot weld (p<0.001) and stress shielding (p=0.010) of proximal femur were more pronounced in Dorr C type femora than in type A or B [Fig. 3]. The prevalence of intraoperative (p=0.550) or postoperative (p=0.600) femoral fractures were not significantly different among the groups.

From over a 10-year follow-up, the PSW stem provided excellent stem survivorship regardless of Dorr type with satisfactory outcomes. The remodeling process around the stem was more pronounced in Dorr type C femur. The present study shows that the PSW stem is a recommendable option for Dorr type C femur.

For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 114 - 114
1 Mar 2017
Yoon P Lee S Kim J Kim H Yoo J
Full Access

Alternative bearing surfaces has been introduced to reduce wear debris-induced osteolysis after total hip arthroplasty (THA) and offered favorable results. Large population-based data for total joint surgery permit timely recognition of adverse results and prediction of events in the future. The purpose of this study was to present the epidemiology and national trends of bearing surface usage in primary total hip arthroplasty (THA) in Korea using nationwide database.

A total of 30,881 THAs were analyzed using the Korean Health Insurance Review and Assessment Service database for 2007 through 2011. Bearing surfaces were sub-grouped according to device code for national health insurance claims and consisted of ceramic-on-ceramic (CoC), metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and metal-on-metal (MoM). The prevalence of each type of bearing surface was calculated and stratified by age, gender, hospital type, primary payer, and procedure volume of each hospital.

The number of primary THAs increased by 25.2% from 5,484 in 2007 to 6,866 in 2011. The average age of the entire study population was 58.1 years, and 53.5% were male [Table 1]. CoC was the most commonly used bearing surface (76.7%), followed by MoP (11.9%), CoP (7.3%), and MoM (4.1%). The distribution of bearing surfaces was identical to that in the general population regardless of age, gender, hospital type, and primary payer [Table 2]. The mean age of patients that received hard-on-hard bearing surfaces (CoC and MoM) was significantly younger than that of patients receiving hard-on-soft bearing surfaces (CoP and MoP) (56.9 years vs. 62.6 years). During the study period, 55.1% of THAs that used a hard-on-hard bearing surface were performed in males, while 53.0% of THAs that used a hard-on-soft bearing surface were performed in females. The order of prevalence of bearing surfaces was identical in low- and medium-volume hospitals (CoC was first, MoP was second, CoP was third, and MoM was fourth). The mean hospital charges did not differ according to the bearing surface used, with the exception of CoP, which was associated with a lower mean hospital charge. There were no changes in the distribution of bearing surfaces in each year between 2007 and 2011. Overall, the percentage of THAs that used CoC bearing surfaces increased substantially from 71.6% in 2007 to 81.4% in 2011, while the percentage that used CoP, MoP, and MoM decreased significantly [Fig. 1].

One of the reasons for the dominant usage of hard-on-hard bearing surfaces may be that the principal diagnosis of primary THAs and the patient age group distribution in Korea differ from those in other countries. The most common indication for primary THA is osteonecrosis of the femoral head in Korea. In contrast, the majority of primary THAs are performed for osteoarthritis in Western countries. The choice of bearing surface may be affected by many factors, including the nation's medical delivery system, payment type, disease pattern, and age distribution of patients that undergo THA. In future, the results of a large-scale nationwide study on primary THAs using CoC bearing surfaces in Korea will be reported.

For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 27 - 27
1 Mar 2017
Moon J Kim J Shon W
Full Access

Introduction

Proper positioning of the baseplate and optimal screw placement are necessary to avoid loosening or failure of the glenoid component in RTSA. Several in vitro and anatomic studies have documented ideal number, size, length and angulation of baseplate screws. However, such fixation can often be tenuous, as the anatomy of scapula bone varies. Furthermore, it can be difficult to identify regions with the best bone stock intraoperatively even though surgeons have an understanding of scapular anatomy with potential screw trajectories in mind. This often leads to variable screw lengths and angulations in the clinical setting. The purpose of this study was to measure optimal screw lengths and angles to reach ideal regions in cadaveric scapulae and to compare the clinical experiences of three surgeons with each other and against a cadaveric model with screw lengths and angulations.

Materials and Methods

Seven cadaveric scapulae were used as the template for optimal screw angulation and length for baseplate implantation. Total 21 cases (seven cases of each 3 surgeons) of reverse total shoulder arthroplasty using the Aequalis®-Reversed shoulder prosthesis (Tornier, France) were included. Measurement of screw angulation was done on the AP and axillary views to account for the superior-inferior and the antero-posterior angulations, respectively. The screw lengths used on each scapula was recorded prior to insertion in cadavers and retrieved from the operative records in clinical cases. Screws directed anteriorly and superiorly were recorded as positive values while posteriorly and inferiorly directed screws were designated negative values. The significant differences in degrees of screw angulation and screw lengths among the 3 surgeon groups were calculated using the ANOVA, with the p value at 0.05. The Mann-Whitney U test was performed to evaluate the cadaver group against the surgeon groups.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 110 - 110
1 Mar 2017
Yoo J Lee S Kim J Seo W Kim H
Full Access

Background

A cell-based tissue-engineered construct can be employed for treating meniscal lesions occurring in the non-vascularized inner two-thirds. The objective of this study was to test the hypothesis that both pre-differentiation of human bone marrow derived stromal cells (hBMSCs) into chondrogenic lineage before cell seeding and platelet-rich plasma (PRP) pretreatment on a PLGA mesh scaffold enhances the healing capacity of the meniscus with hBMSCs-seeded scaffolds in vivo.

Methods

PRP of 5 donors was mixed and used for the experiments. The woven PLGA mesh scaffold (VicrylTM, Ethicon) measuring 20×8 mm (thickness, 0.2 mm) was prepared. The scaffolds were immersed into 1,000 μl of PRP and were centrifuged at 150g for 10 min. Then, the scaffold was flipped 180° and the same procedure was done for the other side. After washing, the scaffolds were soaked into 1,000 μl of DMEM media. hBMSCs from an iliac crest of 10 patients after informed consent and approval of our IRB were induced into chondrogenic differentiation with chondrogenic media containing 10 ng/ml rhTGF-ß3 in 1.2% alginate bead culture system for 7 days. Then, 2×105 hBMSCs were recovered, seeded onto the scaffold, and cultured under dynamic condition. Based on the presence of pre-differentiation into chondrogenic lineage and the PRP pretreatment, 4 study groups were prepared. (no differentiation without PRP, no differentiation with PRP, chondrogenic differentiation without PRP, chondrogenic differentiation with PRP) Cell number for each cell-seeded scaffold was determined at 24 hours after seeding. Then, scaffolds were placed between human meniscal discs and were implanted subcutaneously in nude mice for 6 weeks (n=10 per group).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 118 - 118
1 Mar 2017
Ro J Kim C Kim J Yoo O
Full Access

Introduction

Total knee arthroplasty (TKA) is a well proven surgical procedure. Squat and gait motions are common activities in daily life. However, squat motion is known as most dissatisfying motion in activities in daily life after total knee arthroplasty (TKA). Dissatisfaction after TKA might refer to muscle co-contraction between quadriceps and hamstrings. The purposed of this study was to develop squat and gait simulation model and analyses the contact mechanics and quadriceps and hamstring muscle stability. We hypothesized that squat model shows larger contact forces and lower hamstring to quadriceps force ratio than gait model.

Materials and Methods

Squat motion and gait model were simulated in musculoskeletal simulation software (AnyBody Modeling System, AnyBody Technology, Denmark). Subject-specific bone models used in the simulation were reconstructed from CT images by Mimics (Materialize, Belgium). The lower extremity model was constructed with pelvis, femur, tibia, foot segments and total knee replacement components: femoral component, tibial insert, tibial tray, and patella component [Fig.1]. The muscle model was consisted of 160 muscle elements. The TKR components used in this study are PS-type LOSPA Primary Knee System (Corentec Co., Ltd, Republic of Korea). Force-dependent kinematics method was used in the simulation. The model was simulated to squat from 15° to 100° knee flexion, in 100 frames. Gait simulation model was based on motion capture and force-plate system. Motion capture and force-plate data were from grand challenge competition dataset.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 67 - 67
1 Feb 2017
Kim J Baek S Kim S
Full Access

Introduction

The mid- or long-term results of acetabular revision total hip arthroplasty (THA) in Korea are rare. The purpose of this study is to report the mid-term radiographic results (> 5 years) of acetabular revision THA with porous-coated cementless Trilogy® cup (Zimmer, Warsaw, IN, USA).

Materials and Methods

Between 1999 and 2010, 77 patients (79 hips) had underwent acetabular revision THA with Trilogy® cup. Eight patients (8 hips) were excluded due to death before 5-year follow-up, and 22 patients (23 hips) were excluded due to less than 5-year follow-up or follow-up loss. Forty-seven patients (48 hips) were included in our study. The mean age was 57.9 years (range, 36 to 76 years) and the mean follow-up was 9.8 years (range 5.0 to 16.2 years). The causes of revision were aseptic loosening in 40 hips, and septic loosening in 8 hips, respectively. Both acetabular and femoral revisions were performed in 14 hips and isolated acetabular revision was done in 34 hips. Preoperetive acetabular bone defect according to Paprosky classification was; 1 in type I, 6 in IIA, 11 in IIB, 9 in IIC, 15 in IIIA, and 6 in IIIB.


Purpose

To compare the clinical and radiological results between internal fixation using the proximal femoral nail system and bipolar hemiarthroplasty in reverse oblique intertrochanteric hip fracture in elderly patients.

Materials and Methods

From January 2005 to July 2012, we reviewed 53 patients who had been treated surgically for reverse oblique intertrochanteric fracture and been followed up on for a minimum of 2 years. The patients, all over 70 years old, were divided into two groups for retrospective evaluation: one group was treated with open reduction and internal fixation using the proximal femoral nail system (31 cases), and the other group was treated with bipolar hemiarthroplasty (22 cases).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 137 - 137
1 Feb 2017
Gilbert J Grostefon J Mali S Kim J Ouellette E
Full Access

Introduction

Mechanically assisted crevice corrosion (MACC) of head-neck modular taper junctions is prevalent in virtually all head neck tapers in use today. To date, no clear in vitro tests of design, material or surgical elements of the modular taper system have been reported that show which factors principally affect MACC in these tapers. Possible elements include seating load, head-neck offset, surface roughness, taper engagement length, material combination, angular mismatch, and taper diameter. The goals of this study were to use an incremental fretting corrosion test method1 to assess the above 7 elements using a design of experiments approach. The hypothesis is that only one or two principal factors affect fretting corrosion.

Methods

A 27-2 design of experiment test (7 factors, ¼ factorial, n=32 total runs, 16 samples per condition per factor) was conducted. Factors included: Assembly Force (100, 4000N), Head Offset (1.5, 12 mm), Taper Locking Position (Mouth, Throat), Stem Taper Length (0.44, 0.54 in), Stem Taper Roughness (Ground, Ridged), Taper Diameter (9/10, 12/14), and Stem Material (CoCrMo, Ti-6Al-4V). The heads were CoCrMo coupled with taper coupons (DePuy Synthes, Warsaw, IN). Test components were assembled wet and seated axially with 100 or 4000N assembly force. The assemblies were immersed in PBS and potentiostatically held at −50mV vs. Ag/AgCl. Incremental cyclic loads were applied vertically to the head at 3Hz until a 4000N maximum load was reached (See Fig. 1). Fretting currents at 4000 N cyclic load were used for comparisons while other parameters, including onset load, subsidence, micromotion and pull off load were also captured. Statistical analysis was performed using Pareto charts and Student's T-tests for single factor comparisons (P < 0.05 was statistically significant).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 69 - 69
1 Feb 2017
Kim J Cho H
Full Access

Purpose

We evaluated the clinical and radiographic outcomes of cementless bipolar hemiarthroplasty using rectangular cross-section stem for femoral neck fracture in elderly patients more than 80 years of age with osteoporosis.

Material and Methods

76(cemented 46, cementless 30) bipolar hemiarthroplasties for femur neck fracture were performed in elderly patients more than 80 years old. The mean follow-up period was 4.3 years (2 to 7 years). The Harris hip score at last follow-up and pre-postoperative daily living activity scale according to Kitamura methods were analyzed clinically. The radiological results were assessed using stability of femoral stem and other complications were evaluated. Results: At last follow-up, there were no significant differences of Harris hip score and daily living activity between two groups. Stem loosening and instability were not observed in cementless arthroplasty. There were 18 cases of osseous fixation in radiologic study. There were 1 case of dislocation and 1 case of superficial infection in cemented arthroplasty and 1 case of deep infection in cementless arthroplasty.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 109 - 109
1 Feb 2017
Kim J Han H Lee S Lee M
Full Access

Background

Rotational alignment is important for the long-term success and good functional outcome of total knee arthroplasty (TKA). While the surgical transepicondylar axis (sTEA) is the generally accepted landmark on the distal femur, a precise and easily identifiable anatomical landmark on the tibia has yet to be established. Our aim was to compare five axes on the proximal tibia in normal and osteoarthritic (OA) knees to determine the best landmark for determining rotational alignment during TKA.

Methods

One hundred twenty patients with OA knees and 30 without knee OA were recruited for the study. Computed tomography (CT) images were obtained and converted through multiplanar reconstruction so the angles between the sTEA and the axes of the proximal tibia could be measured. Five AP axes were chosen: the line connecting the center of the posterior cruciate ligament(PCL) and the medial border of the patellar tendon at the cutting level of the tibia (PCL-PT), the line from the PCL to the medial border of the tibial tuberosity (PCL-TT1), the line from the PCL to the border of the medial third of the tibia (PCL-TT2), the line from the PCL to the apex of the tibia (PCL-TT3), and the AP axis of the tibial prosthesis along with the anterior cortex of the proximal tibia (anterior tibial curved cortex, ATCC).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 105 - 105
1 May 2016
Kim J Park B Cho H
Full Access

Purpose

To observe the follow-up results of standard cemented bipolar hemiarthroplasty with double loop and tension band wiring technique for treatment of unstable intertrochanteric hip fractures in elderly patients with osteoporosis.

Materials and Methods

From May 2000 to May 2006, 86 cemented bipolar hemiarthroplasties were performed in elderly patients who had unstable intertrochanteric fractures. The mean age at the time of surgery was 82 years old. The average follow-up period were 5.3 years. We evaluated post-operative results after operation by clinical and radiographic methods.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 79 - 79
1 May 2016
Cho H Park B Kim J
Full Access

Purpose

To perform comparative analysis between the results of internal fixation using proximal femoral nail system and bipolar hemiarthroplasty in pantrochanteric hip fracture in elderly patients.

Materials and Methods

From January 2006 to February 2012, we reviewed 43 patients, who were treated surgically for pantrochanterichip fractures, with a minimum of 2 years follow up. The patient's age was older than 70 year old. The patients were divided into three groups and evaluated, retrospectively. The fracture reduction were regarded as satisfactory in S-OR-IF group(17 cases) and unsatisfactory in US-OR-IF group(9 cases) and the other group was treated with bipolar hemiarthroplasty (BHA group, 17 cases.)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 102 - 102
1 May 2016
Kim J Kim S
Full Access

Background

Theoretically, improved material properties of new alumina matrix composite (AMC) material, Delta ceramics, are expected to decrease concerns associated with pure alumina ceramics and allow manufacturing thinner liners and consequent larger heads. However, limited short-term clinical results are available and mid-term results of these effects are unclear.

Questions/Purposes

(1) Does AMC material decrease the rate of ceramic fracture and noise, concerns of previous-generation ceramics, following change of material properties? (2) Does the possible use of larger heads consequent to manufacturing thinner liners decrease dislocation rate and affect inguinal pain? (3) Do any other complications associated with the use of AMC ceramics occur?


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 96 - 96
1 May 2016
Kim K Lee S Kim J Shin W
Full Access

Background

In this study, we investigated the long-term clinical results and survivorship of minimally invasive unicompartmental knee arthroplasty (UKA) by collecting cases that have been implanted for >10 years ago.

Methods

Medial UKA on 180 cases in 142 patients was performed over a period of 1 year after the first introduction of minimally invasive UKA from January 2002 to December 2002. Among these, 166 cases in 128 patients who underwent Oxford phase 3 medial UKA using the minimally invasive surgery, with the exclusion of 14 cases including 10 cases of follow-up loss and 4 cases of death, were selected as the subject. The mean age of the patients at the time of surgery was 61 years, and the duration of the follow-up was minimum 10 years. All the preoperative diagnosis was osteoarthritis of the knee joint. Clinical and radiographic assessments were measured by the Knee Society clinical rating system, and the survival analysis was confirmed by the Kaplan–Meier method with 95% confidence interval (CI).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 97 - 97
1 May 2016
Kim K Lee S Kim J Ko D
Full Access

Purpose

To identify the modes of failure after total knee arthroplasty (TKA) in patients ≤ 55 years of age and to compare with those ≥ 56 years of age in patients who underwent revision TKA.

Materials and Methods

We retrospectively reviewed 256 revision TKAs among patients who underwent TKA for knee osteoarthritis between January 1992 and December 2012. The causes of TKA failure were analyzed and compared between those ≤ 55 years of age and those ≥ 56 years of age. The age at the time of primary surgery was ≤ 55 years in 30 patients (31 knees) and ≥ 56 years in 210 patients (225 knees).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 99 - 99
1 May 2016
Kim J Yoo O Seo J Jang Y Kim J Sun D Kim Y
Full Access

Introduction

A stem extension improves fixation stability of a tibial component. We need caution not to contact the tibial cortex with an offset adaptor. A symmetric tibial stem design often requires the component's re-positioning with negative effects. Therefore, the objective of this study was to validate clinical efficacy of a tibial baseplate with asymmetric stemmed position (TB-ASP) using aligning outlier rate. We hypothesized that TB-ASP design will be better aligned without unessential offset adaptor than a tibial baseplate with symmetric stemmed position (TB-SSP).

Methods

TB-ASP was designed based on the anthropometric standard model (58 female cadavers, 54.7±11.4 years)(Figure 1.). To validate the stem position, 3D bone models of 20 OA patients (71.8±7.2 years) was reconstructed. All virtual surgery has done by one surgeon with consistent surgical procedure for the analysis criteria.

An analysis of TB-ASP's aligning outlier was proceeded by following steps; 1) aligning tibial baseplate to the line from medial 1/3 tuberosity to the center of PCL, 2) selecting tibial baseplate's size for maximal bone coverage without problematic overhang, 3) trying to displace tibial baseplate and stem extension(120mm long) not to contact tibial cortex. A case invading tibial cortex was considered to be an outlier. The ratio using offset adaptor was compared to those of TB-SSP. Statistical analysis was performed using paired t-test.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 2 - 2
1 May 2016
Lim Y Kwon S Sun D Kim S Kim J Choi S Kim Y
Full Access

Introduction

3-D Printing with direct metal tooling (DMT) technology was innovatively introduced in the field of surface treatment of prosthesis to improve, moreover to overcome the problems of plasma spray, hopefully resulting in opening the possibility of another page of coating technology. We presumed such modification on the surface of Co-Cr alloy by DMT would improve the ability of Co-Cr alloys to osseointegrate.

Method

We compared the in vitro and in vivo ability of cells to adhere to DMT coated Co-Cr alloy to that of two different types of surface modifications: machined and plasma spray(TPS). We performed energy-dispersive x-ray spectroscopy and scanned electron microscopy investigations to assess the structure and morphology of the surfaces. Biologic and morphologic responses to osteoblast cell lines of human were then examined by measuring cell proliferation, cell differentiation (alkaline phosphatase activity), and avb3 integrin. The cell proliferation rate, alkaline phosphatase activity, and cell adhesion in the MAO group increased in comparison to those in the machined and grit-blasted groups.