Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 113 - 113
1 Jan 2016
Munir S Molloy D Hasted T Jack CM Shimmin A Walter W
Full Access

Sagittal stability of the knee is believed to be of significant importance following total knee arthroplasty. We examine four different knee designs at a minimum of twenty-four months postoperatively. Sagittal stability was measured at four degrees of flexion: 0°; 30°; 60°; and 90°, to examine the effect of design on mid-flexion stability.

The knee designs included were: the rotating platform LCS design (DePuy); the cruciate sparing Triathlon system (Stryker); SAIPH system (Matortho, UK); and the medial rotating knee design, MRK (Matortho, UK).

Following ethical approval, 64 cases were enrolled into the study, 22 male and 42 female. Inclusion criteria included: a minimum of 18 months from surgery; ability to flex beyond 90 degrees; and have no postoperative complications. 18 LCS, 18 MRK, 14 SAIPH and 14 Triathlon knee designs were analysed. Sagittal stability was measured using the KT1000 device. Active range of movement was measured using a hand held goniometer and recorded as was Oxford knee score, WOMAC knee score, SF12 and Kujala patellofemoral knee score.

Mean follow-up was 33.7 months postoperative, with a mean age of 72 years. Mean weight was 82.7kgs and height 164cms. There was no significant difference in preoperative demographics between the groups. Mean active post-operative range of motion of the knee was from 2–113° with no significant difference between groups.

Sagittal stability was similar in all four groups in full extension; however the MRK and SAIPH designs showed improved stability in the mid-range of flexion (30–90°). Patient satisfaction also showed a similar trend with MRK achieving better patient reported functional outcomes and satisfaction than that of the SAIPH, LCS and Triathlon systems.

All four knee designs demonstrated good post-operative range of movement with comparative improvement of patient scores to other reported studies. The MRK and SAIPH knee design showed an improved mid-flexion sagittal stability with better patient reported satisfaction and functional scores.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 333 - 338
1 Mar 2013
Jack CM Molloy DO Walter WL Zicat BA Walter WK

The practice of removing a well-fixed cementless femoral component is associated with high morbidity. Ceramic bearing couples are low wearing and their use minimises the risk of subsequent further revision due to the production of wear debris. A total of 165 revision hip replacements were performed, in which a polyethylene-lined acetabular component was revised to a new acetabular component with a ceramic liner, while retaining the well-fixed femoral component. A titanium sleeve was placed over the used femoral trunnion, to which a ceramic head was added. There were 100 alumina and 65 Delta bearing couples inserted.

The mean Harris hip score improved significantly from 71.3 (9.0 to 100.0) pre-operatively to 91.0 (41.0 to 100.0) at a mean follow up of 4.8 years (2.1 to 12.5) (p < 0.001). No patients reported squeaking of the hip.

There were two fractures of the ceramic head, both in alumina bearings. No liners were seen to fracture. No fractures were observed in components made of Delta ceramic. At 8.3 years post-operatively the survival with any cause of failure as the endpoint was 96.6% (95% confidence interval (CI) 85.7 to 99.3) for the acetabular component and 94.0% (95% CI 82.1 to 98.4) for the femoral component.

The technique of revising the acetabular component in the presence of a well-fixed femoral component with a ceramic head placed on a titanium sleeve over the used trunnion is a useful adjunct in revision hip practice. The use of Delta ceramic is recommended.

Cite this article: Bone Joint J 2013;95-B:333–8.


Bone & Joint Research
Vol. 1, Issue 8 | Pages 167 - 173
1 Aug 2012
Jack CM Rajaratnam SS Khan HO Keast-Butler O Butler-Manuel PA Heatley FW

Objectives

To assess the effectiveness of a modified tibial tubercle osteotomy as a treatment for arthroscopically diagnosed chondromalacia patellae.

Methods

A total of 47 consecutive patients (51 knees) with arthroscopically proven chondromalacia, who had failed conservative management, underwent a modified Fulkerson tibial tubercle osteotomy. The mean age was 34.4 years (19.6 to 52.2). Pre-operatively, none of the patients exhibited signs of patellar maltracking or instability in association with their anterior knee pain. The minimum follow-up for the study was five years (mean 72.6 months (62 to 118)), with only one patient lost to follow-up.