header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

SAGITTAL STABILITY IN FOUR DIFFERENT KNEE DESIGNS: A SINGLE-CENTRE INDEPENDENT REVIEW

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 4.



Abstract

Sagittal stability of the knee is believed to be of significant importance following total knee arthroplasty. We examine four different knee designs at a minimum of twenty-four months postoperatively. Sagittal stability was measured at four degrees of flexion: 0°; 30°; 60°; and 90°, to examine the effect of design on mid-flexion stability.

The knee designs included were: the rotating platform LCS design (DePuy); the cruciate sparing Triathlon system (Stryker); SAIPH system (Matortho, UK); and the medial rotating knee design, MRK (Matortho, UK).

Following ethical approval, 64 cases were enrolled into the study, 22 male and 42 female. Inclusion criteria included: a minimum of 18 months from surgery; ability to flex beyond 90 degrees; and have no postoperative complications. 18 LCS, 18 MRK, 14 SAIPH and 14 Triathlon knee designs were analysed. Sagittal stability was measured using the KT1000 device. Active range of movement was measured using a hand held goniometer and recorded as was Oxford knee score, WOMAC knee score, SF12 and Kujala patellofemoral knee score.

Mean follow-up was 33.7 months postoperative, with a mean age of 72 years. Mean weight was 82.7kgs and height 164cms. There was no significant difference in preoperative demographics between the groups. Mean active post-operative range of motion of the knee was from 2–113° with no significant difference between groups.

Sagittal stability was similar in all four groups in full extension; however the MRK and SAIPH designs showed improved stability in the mid-range of flexion (30–90°). Patient satisfaction also showed a similar trend with MRK achieving better patient reported functional outcomes and satisfaction than that of the SAIPH, LCS and Triathlon systems.

All four knee designs demonstrated good post-operative range of movement with comparative improvement of patient scores to other reported studies. The MRK and SAIPH knee design showed an improved mid-flexion sagittal stability with better patient reported satisfaction and functional scores.


Email: