Over the past decade, there has been an increase in the number of total knee arthropalsty (TKA). Demand of TKA for the young patients who often have high physical demands is also increasing. However, the revision rate in such young patients is much higher due to polyethylene (PE) wear and instability (Julin J, Acta Orthop 2010). Therefore, next generation total knee prostheses are expected to decrease PE wear and to provide stability. Although Patients who underwent bilateral staged TKAs were more likely to prefer medial pivot prosthesis or ACL-PCL retaining prosthesis than the other types of prostheses, because they feels “more stable overall” (Pritchett JW, J Arthroplasty 2011). The excellent mid-term clinical results of those newly introduced total knee prosthesis, such as alumina medial pivot TKA (Iida T, ORS 2008), medial pivot TKA (Mannan K, JBJS Br 2009, Kakachalions T, Knee 2009), ACL-PCL retaining TKA (Clouter JM, JBJS Am 1999), and highly cross-linked PE (Hodrick JT, CORR 2008), have been reported. From the point of view of
There is many reports about complications with a resurfacing total hip arthroplasty (RHA). One of the most common complications is the femoral neck fracture. A notch and malalignment were risk factors for this. For an accurate implanting the femoral component in RHA, we performed 3D template and made a patient specific template (PST) using 3D printer and applied this technique for a clinical usage. We report a preliminary early result using this novel technique. We performed 10 RHAs in nine patients (7 male, 2 female) from June 2009 to March 2010 due to osteonecrosis in 7 hips and secondary osteoarthritis in 3hips with a mean age of 48 years (40-60). We obtained a volumetric data from pre-operative CT and planned using 3D CAD software. Firstly, size of femoral components were decided from the size planning of cups. We aimed a femoral component angle as ten degrees valgus to the neck axis in AP and parallel in lateral view avoiding a notch. We measured femoral shaft axis and femoral neck axis in AP and lateral view using 3D processing software. PSTs were made using Laser Sintering by 3D printer which had the heat tolerance for sterilization in order to insert the femoral guide wire correctly. We operated in postero-lateral approach for all the patients PST has the base (contact part) fit to poterior inter trochanteric area. It has the arm reached from the base and sleeve hole to insert the guide pin into the femoral head. We measured the femoral component angle in three dimensions using the 3D processing software postoperatively. We compared the difference of this angle and the pre-operative planed angles. We also investigated the operation time, the volume of bleeding during operation and complications.Introduction
material and method