header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 19 - 19
10 May 2024
Earp J Hadlow S Walker C
Full Access

Introduction

This study aimed to assess the relationship between preparation times and operative procedures for elective orthopaedic surgery. A clearer understanding of these relationships may facilitate list organisation and thereby contribute to improved operating theatre efficiency.

Methods

Two years of elective orthopaedic theatre data was retrospectively analysed. The hospital medical information unit provided de- identified data for 2015 and 2016 elective orthopaedic cases, from which were selected seven categories of procedures with sufficient numbers to allow further analysis - primary hip and knee replacement, spinal surgery, shoulder surgery (excluding shoulder replacement), knee surgery, foot and ankle surgery (excluding ankle replacement), Dupuytrens surgery and general orthopaedic surgery. The data analysed included patient age, ASA grade, operation, operation time, and preparation time (calculated as the time from the start of the anaesthetic proceedings to the patient's admission to Recovery, with the operating time [skin incision to skin closure] subtracted). Statistical analysis of the data was undertaken.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 41 - 41
1 Sep 2012
Richmond B Munro J Walker C Hadlow S Lynskey T
Full Access

Proximal tibial bone mineral density (BMD) has been shown to decrease following Total Knee Arthroplasty (TKA) by both dual-energy x-ray absorbtiometry (DEXA) and quantitative computed tomography (qCT)-assisted osteodensitometry. Little is known about changes in BMD following unicompartmental knee arthroplasty (UKA). Additionally, there are proposed differences in stress transmission between cemented metal and polyethylene (PE) components. We proposed two hypotheses. First, that proximal tibial BMD decreases following UKA. Second, that BMD loss would be greater below metal tibial components.

We performed a prospective clinical trial of 50 consecutive UKAs in 49 patients performed by two surgeons at one institution. There were 25 mobile bearing Oxford and 25 fixed bearing Accuris arthroplasties, all were medial. BMD was assessed with qCT-assisted osteodensitometry scans prior to discharge and then at 1 and 2 years post surgery. Each CT slice was divided into medial and lateral halves and cortical and cancellous bone was analysed separately. The six 2mm slices immediately beneath the tibial implant were analysed using previously validated software to create a three-dimensional assessment of BMD. The lateral half was used as a control.

There were a total of 30 females (60%), with an average age of 70 (49–84). One patient was lost to follow-up and another was unable to be analysed due to failure requiring revision before follow-up was complete. Preliminary results showed no significant change in BMD at either 1 or 2 years follow-up. There was no difference in BMD change between the mobile and fixed bearing prostheses, between the medial and lateral halves nor between cortical and cancellous bone. Final results will be presented at the AONZOA conference.

This trial shows that UKA does not result in significant change to BMD at 2 years. The preservation of BMD may indicate that UKA is better at maintaining physiologic stress transfer than a TKA, which has been shown to be associated with a reduction in BMD.