Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 38 - 38
24 Nov 2023
Tiruveedhula M Graham A Thapar A Dindyal S Mulcahy M
Full Access

Aim

To describe a 2-stage treatment pathway for managing neuropathic forefoot ulcers and the safety and efficacy of percutaneous tendo-Achilles lengthening (TAL) in out-patient clinics.

Methods

Forefoot ulcers in patients with diabetic neuropathy are a result of factors that result in increased forefoot plantar pressure. Plantar flexed metatarsal heads secondary to progressive claw toe deformity and hindfoot equinus from changes within the gastrocnemius-soleus-tendo-Achilles complex, with additional contraction of tibialis posterior and peroneal longus, secondary to motor neuropathy results in progressive increase in forefoot plantar pressures.

Consecutive patients, who presented to our Diabetic Foot clinic since February 2019 with forefoot ulcers or recurrent forefoot callosity were treated with TAL in the first instance, and in patients with recurrent or non-healing ulcers, by proximal dorsal closing wedge osteotomy; a 2-stage treatment pathway.

Patients were followed up at 3, 6, and 12 months to assess ulcer healing and recurrence.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 37 - 37
24 Nov 2023
Tiruveedhula M Graham A Thapar A Dindyal S Mulcahy M
Full Access

Aim

The aim of this paper is to analyse the cause of neuropathic diabetic foot ulcers and discuss their preventive measures.

Methods

Review of patients with foot ulcers managed in our diabetic MDT clinics since Feb 2018 were analysed. Based on this observation and review of pertinent literature, following observations were made.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 7 - 7
1 Nov 2022
Tiruveedhula M Mallick A Dindyal S Thapar A Graham A Mulcahy M
Full Access

Abstract

The aim is to describe the safety and efficacy of TAL in out-patient clinics when managing diabetic forefoot ulcers.

Patients and Methods

Consecutive patients, who underwent TAL and had minimum 12m follow-up were analysed. Forceful dorsiflexion of ankle was avoided and patients were encouraged to walk in Total contact cast for 6-weeks and further 4-weeks in walking boot.

Results

142 feet in 126 patients underwent this procedure and 86 feet had minimum follow-up of 12m. None had wound related problems. Complete transection of the tendon was noted in 3 patients and one-patient developed callosity under the heel.

Ulcers healed in 82 feet (96%) within 10 weeks however in 12 feet (10%), the ulcer recurred or failed to heal. MRI showed plantar flexed metatarsals with joint subluxation. The ulcer in this subgroup healed following proximal dorsal closing wedge osteotomy.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 60 - 60
1 May 2012
Raman R Dickson D Angus P Ridge J Johnson G Graham A
Full Access

We aim to report the clinical and radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong HAC coated femoral and acetabular components.

We reviewed 586 consecutive cementless primary THA in 542 patients with a minimum 12-18 year follow-up, performed at one institution between 1986 and 1994. Twenty-eight (32 THA) were lost to follow-up. Clinical outcome was measured using Harris, Charnley and Oxford scores. Quality of life using EuroQol

EQ-5D. Radiographs were systematically analysed.

The mean age was 75.2 years. Dislocation occurred in 12 patients (three recurrent). Re operations were performed in 11 patients (1.9%). Four acetabular and one stem revisions were performed for aseptic loosening. Other re-operations were for infection (two), periprosthetic fractures (two), cup malposition (one), revision of worn liner (two). The mean Harris and Oxford scores were 89 (79–96) and 18.4 (12–32) respectively. The Charnley score was 5.7 for pain, 5.3 for movement and 5.4 for mobility. Acetabular radiolucencies were present in 54 hips (9.7%).

The mean linear polythene wear was 0.06 mm/year. Stable stem by bony ingrowth was identified in all hips excluding one femoral revision case. Mean stem subsidence was 2.2mm (0.30–3.4mm). Radiolucencies were present around 37 (6.6%) stems. EQ- 5D description scores and health thermometer scores were 0.81 (0.71–0.89) and 86 (64–95). With an end point of definite or probable loosening, survival at 12 years was 96.1% for acetabular and 98.3% for femoral components. Overall survival at 12 years with removal or repeat revision of either component for any reason as the end point was 97.2%.

The results of this study support the continued use of a fully coated prosthesis and documents the durability of the HAC coated components. In our clinical experience, the Furlong prosthesis revealed encouraging radiographic stability over a long-term period.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 224 - 224
1 May 2012
Raman R Dickson D Sharma H Angus P Shaw C Johnson G Graham A
Full Access

We report the clinical and radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong Hydroxyapatite ceramic (HAC) coated acetabular components.

We reviewed 412 consecutive cementless primary THA using fully coated acetabular shell in 392 patients—with a minimum 12 to 18 year follow-up—performed at two institutions between 1986 and 1994. Twenty (22 THA) were lost prior to 12-year follow-up, leaving 372 patients (390 THA) available for study. Fully HAC coated stems were used in all patients. The clinical outcome was measured using Harris, Charnley and Oxford hip scores and the quality of life using EuroQol EQ-5D. Radiographs were systematically analysed for implant position, loosening, migration, osteolysis. Polythene wear was digitally measured. The radiographic stability of the acetabular component was determined by Enghs criteria.

The mean age was 74.4 years. The mean Harris and Oxford scores were 87 (78– 97) and 19.1 (12–33) respectively. The Charnley score was 5.6 (5-6) for pain, 5.2 (4–6) for movement and 5.3 (4–6) for mobility. Migration of acetabular component was seen in four hips. Acetabular radiolucencies were present in 54 hips (9.7%). The mean linear polythene wear was 0.06mm/year. Mean inclination was 48.4° (38–65).

Radiolucencies were present around 37 (6.6%) stems. Dislocation occurred in 10 patients (three recurrent). Re-operations were performed in nine patients (1.9%). Four acetabular revisions were performed for aseptic loosening. Other re-operations were for infection (three), periprosthetic fractures (one), cup malposition (one) and revision of worn liner (three). Mean EQ-5D description scores and health thermometer scores were 0.81 (0.71–0.89) and 86 (64–95). With an end point of definite or probable loosening, the probability of survival at 12 years was 97.1% for acetabular component. Overall survival at 12 years with removal or repeat revision of either component for any reason as the end point was 96.2%.

The results of this study support the continued use of a fully coated prosthesis and documents the durability of the HAC coated components. In our clinical experience, the Furlong prosthesis revealed encouraging radiographic stability over a long-term period.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 45 - 45
1 Feb 2012
Topping A Warr R Graham A Pearse M Khan U
Full Access

The literature states pre-operative angiography of open tibial fractures (OTFs) should only be considered if abnormal pedal pulses are present.

Aim

Does pre-operative angiography of OTFs benefit patient management?

Method

43 patients were admitted with OTFs to Charing Cross Hospital, London between 3/2004 and 6/2005. Pedal pulses were documented and routine pre-operative angiography performed following primary surgical debridement. At definitive operation, data was collected prospectively assessing vasculature and the microsurgical findings. All patients underwent free flap reconstruction or amputation. Comparison was made with angiographic findings and whether surgical management had been affected. Retrospective audit of all angiograms was performed by a consultant radiologist establishing the sensitivity/specificity.