Accurate estimations of the risk of fracture due to metastatic bone disease in the femur is essential in order to avoid both under-treatment and over-treatment of patients with an impending pathological fracture. The purpose of the current retrospective in vivo study was to use CT-based finite element analyses (CTFEA) to identify a clear quantitative differentiating factor between patients who are at imminent risk of fracturing their femur and those who are not, and to identify the exact location of maximal weakness where the fracture is most likely to occur. Data were collected on 82 patients with femoral metastatic bone disease, 41 of whom did not undergo prophylactic fixation. A total of 15 had a pathological fracture within six months following the CT scan, and 26 were fracture-free during the five months following the scan. The Mirels score and strain fold ratio (SFR) based on CTFEA was computed for all patients. A SFR value of 1.48 was used as the threshold for a pathological fracture. The sensitivity, specificity, positive, and negative predicted values for Mirels score and SFR predictions were computed for nine patients who fractured and 24 who did not, as well as a comparison of areas under the receiver operating characteristic curves (AUC of the ROC curves).Aims
Methods
Intra-articular 90Yttrium (90Y) is an adjunct
to surgical treatment by synovectomy for patients with diffuse-type tenosynovial
giant-cell tumour (dtTGCT) of the knee, with variable success rates.
Clinical information is, however, sparse and its value remains unclear.
We investigated the long-term outcome of patients who underwent synovectomy
with and without adjuvant treatment with 90Yttrium. All patients with dtTGCT of the knee who underwent synovectomy
between 1991 and 2014 were included in the study. Group A patients
underwent synovectomy and an intra-articular injection of 90Yttrium
between six and eight weeks after surgery. Group B patients underwent
surgery alone.Aims
Patients and Methods
Dislocation is a common complication after proximal and total femur prosthesis reconstruction for primary bone sarcoma patients. Expandable prosthesis in children puts an additional challenge due to the lengthening process. Hip stability is impaired due to multiple factors: Resection of the hip stabilizers as part of the sarcoma resection: forces acts on the hip during the lengthening; and mismatch of native growing acetabulum to the metal femoral head. Surgical solutions described in literature are various with reported low rates of success. Assess a novel 3D surgical planning technology by use of 3D models (computerized and physical), 3D planning, and Patient Specific Instruments (PSI) in supporting correction of young children suffering from hip instability after expandable prosthesis reconstruction following proximal femur resection. This innovative technology creates a new dimension of visualization and customization, and could improve understanding of this complex problem and facilitate the surgical decision making and procedure.Background
Objective
Excision of the proximal femur for tumour with
prosthetic reconstruction using a bipolar femoral head places a considerable
load on the unreplaced acetabulum. We retrospectively reviewed the changes which occur around the
affected hip joint by evaluating the post-operative radiographs
of 65 consecutive patients who underwent proximal prosthetic arthroplasty
of the femur, and in whom an acetabular component had not been used.
There were 37 men and 28 women with a mean age of 57.3 years (17
to 93). Radiological assessment included the extent of degenerative
change in the acetabulum, heterotopic ossification, and protrusio
acetabuli. The mean follow-up was 9.1 years (2 to 11.8). Degenerative changes
in the acetabulum were seen in three patients (4.6%), Brooker grade
1 or 2 heterotopic ossification in 17 (26%) and protrusion of the
prosthetic head in nine (13.8%). A total of eight patients (12.3%) needed a revision. Five were
revised to the same type of prosthesis and three (4.6%) were converted
to a total hip arthroplasty. We conclude that radiological evidence of degenerative change,
heterotopic ossification and protrusion occur in a few patients
who undergo prosthetic arthroplasty of the proximal femur for tumour.
The limited extent of these changes and the lack of associated symptoms
do not justify the routine arthroplasty of the acetabulum in these patients. Cite this article:
Giant cell tumour (GCT) of bone is a benign but locally aggressive tumour. Although topical adjuvants have been used in the past, local recurrence following intralesional excision of GCT of bone continues to remain a problem. The use of bisphosphonates as an anti-osteoclastic agent in the management of osteolytic bone metastases is well accepted. Therefore our study aims to retrospectively demonstrate whether the administration of bisphosphonate as an adjuvant can control aggressive local recurrence of GCT and prevent wide resections of bones or amputations. A retrospective study was performed between 2004 and 2010. 6 patients were diagnosed with aggressive local recurrence of appendicular GCT. All patients were treated for the primary tumour by surgical curettage and cryoablation followed by cementation or biological reconstruction. In 5 patients the tumour was located in the distal radius and in one in the first metacarpal bone. All recurrences were in the bone with large soft-tissue extension. After histological diagnosis – by CT core needle biopsy – the patients were treated by intravenous bisphosphonate, followed by clinical & radiological assessments.Aim
Method
Cryosurgery is a well established modality in the treatment of benign aggressive and low grade malignant tumours. In this setting it allows for intra-lesional resection and preservation of function without compromising oncological outcome. Here we present the outcome of 87 patients treated with cryosurgery for low-grade chondrosarcoma of bone. 87 patients were treated between 1988 and 2005. The mean age was 51 years (range, 8-77 years), and included 47 females and 40 males. Minimal follow-up was two years. Patients were treated for lesions of the distal femur (n = 30), proximal humerus (n = 33), proximal femur (n = 5), proximal tibia (n = 10), and the remaining sites included the iliac bone, distal tibia, forearm, carpal and tarsal bones (n=10). Patients were treated with intralesional curettage through a cortical window, adjuvant burr drilling, cryotherpay and reconstruction with cement or bone graft and hardware fixation when that was clinically indicated.Background
Materials and methods
Various chemicals are commonly used as adjuvant treatment to surgery for giant-cell tumour (GCT) of bone. The comparative effect of these solutions on the cells of GCT is not known. In this study we evaluated the cytotoxic effect of sterile water, 95% ethanol, 5% phenol, 3% hydrogen peroxide (H2O2) and 50% zinc chloride (ZnCI2) on GCT monolayer tumour cultures which were established from six patients. The DNA content, the metabolic activity and the viability of the cultured samples of tumour cells were assessed at various times up to 120 hours after their exposure to these solutions. Equal cytotoxicity to the GCT monolayer culture was observed for 95% ethanol, 5% phenol, 3% H2O2 and 50% ZnCI2. The treated samples showed significant reductions in DNA content and metabolic activity 24 hours after treatment and this was sustained for up to 120 hours. The samples treated with sterile water showed an initial decline in DNA content and viability 24 hours after treatment, but the surviving cells were viable and had proliferated. No multinucleated cell formation was seen in these cultures. These results suggest that the use of chemical adjuvants other than water could help improve local control in the treatment of GCT of bone.
No dislocations were noted during follow-up (range 3–48 months). Radiographs revealed an average vertical displacement of the humeral head compared to its original position of 0.7 cm (range 0–1.7 cm). There were two surgical complications. In one patient the humeral prosthesis migrated proximally and eroded through the skin requiring additional surgery. In another case erosion of the distal clavicle was noted. This was biopsied and foreign body reaction identified.
The locking compression plate (LCP), which is inserted in a minimal invasive technique, utilizing an anterolateral approach to the proximal humerus, allows adequate reduction and fixation, while minimizing the risk for complications derived from extensive exposure and poor fixation.
The patients were followed closely beginning 2 weeks post-operatively and afterwards on a bi-monthly basis. Immediate complications, radiographic and functional outcome were noted.
Functional outcome was good, patients regained 120°±25 of flexion, 112°±27 of abduction and 17°±8 of external rotation.
Positive predictive value calculated for SPECT is 81%, while the negative predictive value calculated is 40%. Separate calculations revealed a PPV of 90.5% in medial meniscal tears and a PPV of 86.7% in lateral meniscal tears respectively. In 13 cases additional inra-articular pathology was noted. In five cases the presumptive diagnosis of a meniscal tear on SPECT was rejected on arthroscopy, in three of these cases the anterior cruciate ligament was injured. One patient with a negative SPECT scan was operated and a meniscal tear found.
Under general anesthesia, the olecranon is approached through a posterior incision. After reduction, fixation is achieved with two K-wires, which are inserted percutaneously. Additional fixation is obtained with a heavy absorbable suture (Dexon, PDS) which is fashioned in a figure of eight around the protruding pins and through a hole in the proximal ulna. Stability is checked under vision before wound closure. K-wires are trimmed and a plaster cast is fitted with the elbow in flexion. The plaster cast and K-wires are removed 4 weeks post surgery after X-rays confirm that the fracture is healed and range of motion is started.
K-wires were removed 4 weeks postoperatively and patients were allowed free range of motion. No immediate complications were noted, none became infected and no loss of fixation was observed.