Ceramic-on-ceramic (CoC) articulations in total hip arthroplasty (THA) have low wear, but the unique risk of fracture. After revision for CoC fracture, ceramic third bodies can lead to runaway wear of cobalt chrome (CoCr) causing extremely elevated blood cobalt. We present five cases of ceramic liner fractures revised to a CoCr head associated with the rapid development of severe cobalt toxicity. We identified 5 cases of fractured CoC THA treated with revision to CoCr on highly cross-linked polyethylene (HXLPE) – three to conventional bearings and two to modular dual mobility bearings (CoCr acetabular liner, CoCr femoral head, and HXLPE). Mean follow up was 2.5 years after CoCr/HXLPE re-revision. Symptoms of cobalt toxicity occurred at average 9.5 months after revision for ceramic fracture (range 6–12). All patients developed vision and hearing loss, balance difficulties, and peripheral neuropathy. Several had cardiomyopathy, endocrinopathy, and local skin discoloration. Two reported hip pain. Re-revision for cobalt toxicity occurred at an average of 22 months (range 10–36) after revision for ceramic fracture. Average serum cobalt level at re-revision was 991 μg/L (range 734–1302, normal <1 μg/L). All CoCr heads exhibited massive wear with asphericity; deep tissues exhibited prominent metallosis. Treatment consisted of debridement and revision to a ceramic head with HXLPE. Serum cobalt improved to an average of 25 μg/L at final follow up. All patients reported partial improvement in vision and hearing; peripheral neuropathy and balance did not recover. Systemic cobalt toxicity is a rare but devastating complication of ceramic fracture in THA treated with cobalt-alloy bearings. Cobalt alloy bearings should be avoided in this setting. The diagnosis of systemic cobalt toxicity requires a high index of suspicion and was typically delayed following systemic symptoms. Debridement and revision to a ceramic-on-HXLPE leads to improvement but not resolution of cobalt toxicity complications.
Wound complications following revision total hip arthroplasty (THA) are associated with an increased risk of superficial and deep infections. Closed incision negative-pressure therapy (ciNPT) has been reported to decrease this risk. This study's purpose was to assess if ciNPT decreases the rate of wound complications following revision THA versus a conventional, silver-impregnated dressing. This was a single center, randomized controlled trial of patients undergoing both septic and aseptic revision THA. Patients received either ciNPT or a silver-impregnated dressing (control) for 7 days. Wound complications within 90 days of the procedure were recorded, including: surgical site infection (SSI), periprosthetic joint infection (PJI), prolonged drainage greater than 5 days, erythema requiring antibiotics, and hematoma formation. An Introduction
Methods
In patients with a “dry” aspiration during the investigation of prosthetic joint infection (PJI), saline lavage is commonly used to obtain a sample for analysis. The aim of this study was to investigate prospectively the impact of saline lavage on synovial fluid analysis in revision arthroplasty. Patients undergoing revision hip (THA) or knee arthroplasty (TKA) for any septic or aseptic indication were enrolled. Intraoperatively, prior to arthrotomy, the maximum amount of fluid possible was aspirated to simulate a dry tap (pre-lavage) followed by the injection with 20 ml of normal saline and re-aspiration (post-lavage). Pre- and post-lavage synovial white blood cell (WBC) count, percent polymorphonuclear cells (%PMN), and cultures were compared.Aims
Methods
In the setting of a “dry” aspiration, saline lavage is commonly used to obtain a sample for analysis. The purpose of this study is to prospectively determine the impact of saline lavage on synovial fluid markers in revision arthroplasty. 79 patients undergoing revision hip (19) and knee (60) arthroplasty were enrolled. Intraoperatively, prior to arthrotomy, the maximum amount of fluid possible was aspirated to simulate a dry-tap (“pre-lavage”) followed by subsequent injection with 20 mL of normal saline and re-aspiration (“post-lavage”). Pre and post-lavage synovial white blood cell (WBC) count, percent polymorphonuclear cells (%PMN), and cultures were compared. Statistical analyses utilized the Wilcoxon signed-rank test.Background
Methods
Opioids are an important component of multimodal analgesia, but improper utilization places patients at risk for overdose and addiction. The purpose of this randomized controlled trial is to determine whether the quantity of opioid pills prescribed at discharge is associated with the total amount of opioids consumed or unused by patients after total hip (THA) and knee (TKA) arthroplasty. 304 Opioid naïve patients undergoing THA or TKA were randomized to receive a prescription for either 30 or 90 5mg oxycodone immediate release (OxyIR) tablets at discharge. All patients received acetaminophen, meloxicam, tramadol and gabapentin perioperatively. Daily opioid consumption, reported in morphine equivalent dose (MED), number of unused OxyIR, and pain scores were calculated for 30 days postoperatively with a patient-completed medication diary. The number of OxyIR refills and total MED received were recorded for 90 days postoperatively. Power analysis determined that 141 patients per group were necessary to detect a 25% reduction in means in opiate consumption between groups. Statistical analysis involved t-test, rank sum, and chi-squared tests with alpha=0.05.Introduction
Methods