Magnetic resonance imaging (MRI) is the gold standard for the diagnosis of the pathologies affecting the glenohumeral joint and the rotator cuff diseases. MRI allows to highlight anatomic discontinuities of both muscles and tendons. However, MRI diagnostic accuracy has not proven to be highly sensitive in distinguishing between a partial-thickness tear and a full-thickness rotator cuff tear. The purpose of this study was to determine if MRI under axial traction can be helpful in increasing MRI sensitivity to identify partial-thickness rotator cuff tears. The study included 10 patients (4 males and 6 females) who had clinical examination and MRI suggesting a partial-thickness rotator cuff tear. They were candidates for shoulder arthroscopy because of persistent symptoms after at least three months of conservative treatment. The patients underwent a new MRI (under axial traction: MRI-AT) with a 4-kg weight applied to the affected arm. Then the patients underwent arthroscopy to confirm the diagnosis. Patients with a suspected full-thickness rotator cuff tear were excluded from the study. Patients’ average age was 52.4 years, and the dominant side was affected in 77.7% of the cases. Preoperative Constant-Murley Score was 57. MRI-AT showed that 3 patients were affected by a complete tear of the rotator cuff, 3 patients by a partial-thickness rotator cuff tear and 4 patients had no lesion. The analysis of data showed that: under axial traction the subacromial space increased by 0,2 mm (P value = 0,001075), the superior glenohumeral space decreased by 2.4 mm (P value = 0,07414), the inferior glenohumeral space increased by 0.3 mm (P value = 0,02942), the acromial angle decreased by 1.9° (P value = 0,0002104) and the acromion-glenohumeral angle decreased by 0.3° (P-value = 0,01974). Two experienced evaluators analyzed previous standard MRI and MRI-AT scans in a double-blinded fashion, with inter-rater evaluation of all the images and measures. Intraclass correlation coefficient (ICC) has been utilized to assess the reliability of the measures performed by different operators. ICC always resulted in more than 0.7, showing a high concordance among values in the same group. A comparative evaluation between standard MRI and MRI-AT has been conducted to highlight possible discrepancies and this has been compared to intraoperative findings. Concordance of the values was 89% between standard MRI and MRI-AT and 100% between MRI under axial traction and intraoperative findings. This study showed a high correlation between the diagnosis achieved with MRI-AT and the intraoperative arthroscopic findings. The use of MRI-AT in clinical practice may improve the diagnostic sensitivity of this method to detect a partial-thickness rotator cuff tear.
The risk of falls in patients undergoing orthopedic procedures is particularly significant in terms of health and socioeconomic effects. The literature analyzed closely this risk following procedures performed on the lower limb, but the implications following procedures on the upper limb remain to be investigated. Interestingly, it is not clear whether the increased risk of falling in patients undergoing shoulder surgery is due to preexisting risk factors at surgery or postoperative risk factors, such as anesthesiologic effects, opioid medications used for pain control, or brace use. Only one prospective study examined gait and fall risk in patients using a shoulder abduction brace (SAB) after shoulder surgery, revealing that the brace adversely affected gait kinematics with an increase in the risk of falls. The main purpose of the study was to investigate the influence of SAB on gait parameters in patients undergoing shoulder surgery. Patients undergoing elective shoulder surgery (arthroscopic rotator cuff repair, reverse total shoulder arthroplasty, and Latarjet procedure), who used a 15° SAB in the postoperative period, were included. Conversely, patients age > 65 years old, with impaired lower extremity function (e.g., fracture sequelae, dysmorphism, severe osteo-articular pathology), central and peripheral nervous system pathologies, and cardiac/respiratory/vascular insufficiency were excluded. Participants underwent kinematic analysis at four different assessment times: preoperative (T0), 24 hours after surgery (T1), 1 week after surgery (T2), and 1 week after SAB removal (T3). The tests used for kinematic assessment were the Timed Up and Go (TUG) and the 10-meter test (10MWT), both of which examine functional mobility. Agility and balance were assessed by a TUG test (transitions from sitting to standing and vice versa, walking phase, turn-around), while gait (test time, cadence, speed, and pelvic symmetry) was evaluated by the 10MWT. Gait and functional mobility parameters during 10MWT and TUG tests were assessed using the BTS G-Walk sensor (G-Sensor 2). One-way ANOVA for repeated measures was conducted to detect the effects of SAB on gait parameters and functional mobility over time. Statistical analysis was performed with IBM®SPSS statistics software version 23.0 (SPSS Inc., Chicago, IL, USA), with the significant level set at p<0.05. 83% of the participants had surgery on the right upper limb. A main effect of time for the time of execution (duration) (p=0.01, η2=0.148), speed (p<0.01, η2=0.136), cadence (p<0.01, η2=0.129) and propulsion-right (R) (p<0.05, η2=0.105) and left (L) (p<0.01, η2=0.155) in the 10MWT was found. In the 10MWT, the running time at T1 (9.6±1.6s) was found to be significantly longer than at T2 (9.1±1.3s, p<0.05) and at T3 (9.0±1.3s, p=0.02). Cadence at T1 (109.7±10.9steps/min) was significantly lower than at T2 (114.3 ±9.3steps/min, p<0.01) and T3 (114.3±9.3steps/min, p=0.02). Velocity at T1 (1.1±0.31m/s) was significantly lower than at T2 (1.2± 0.21m/s, p<0.05). No difference was found in the pelvis symmetry index. No significant differences were found during the TUG test except for the final rotation phase with T2 value significantly greater than T3 (1.6±0.4s vs 1.4±0.3s, p<0.05). No statistically significant differences were found between T0 and T2 and between T0 and T3 in any of the parameters analyzed. Propulsion-R was significantly higher at T3 than T1 (p<0.01), whereas propulsion-L was significantly lower at T1 than T0 (p<0.05) and significantly higher at T2 and T3 than T1 (p<0.01). Specifically, the final turning phase was significantly higher at T2 than T3 (p<0.01); no significant differences were found for the duration, sit to stand, mid-turning and stand to sit phases. The results demonstrated that the use of the abduction brace affects functional mobility 24 hours after shoulder surgery but no effects were reported at longer term observations.
The aim of this systematic review and meta-analysis is to evaluate differences in functional outcomes and complications between single- (SI) and double-incision (DI) techniques for the treatment of distal biceps tendon rupture. A comprehensive search on PubMed, MEDLINE, Scopus, and Cochrane Central databases was conducted to identify studies reporting comparative results of the SI versus the DI approach. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was used for search strategy. Of 606 titles, 13 studies met the inclusion criteria; methodological quality was assessed with the Newcastle-Ottawa scale. Random- and fixed-effects models were used to find differences in outcomes between the two surgical approaches. The range of motion (ROM) and the Disabilities of the Arm, Shoulder and Hand (DASH) scores, as well as neurological and non-neurological complications, were assessed.Aims
Methods
We report on the outcome of the Synergy cementless femoral stem
with a minimum follow-up of 15 years (15 to 17). A retrospective review was undertaken of a consecutive series
of 112 routine primary cementless total hip arthroplasties (THAs)
in 102 patients (112 hips). There were 60 female and 42 male patients
with a mean age of 61 years (18 to 82) at the time of surgery. A
total of 78 hips in the 69 patients remain Aims
Patients and Methods
The optimal management of severe tibial and/or femoral bone loss in a revision total knee arthroplasty (TKA) has not been established. Reconstructive methods include structural or bulk allografts, impaction bone-grafting with or without mesh augmentation, custum prosthetic components, modular metal augmentations of prosthesis and tumor prosthesis. Recently metaphyseal fixation using porous tantalum cones (Zimmer, Warsaw, IN) has been proposed as alternative strategy for severe bone loss. The purposes of this study were to determine the clinical and radiographic outcomes in patients who underwent revision knee arthroplasty with tantalum cones with a minimum of 5-year follow-up.Introduction
Objectives
The use of antibiotic-loaded polymethylmethacrylate bone-cement spacers during two-stage exchange procedures is the standard in the treatment of patients with delayed prosthetic joint infection. The real antimicrobial activity of these spacers is unclear because the adherence of bacteria to cement might result in clinical recurrence of infection. The purpose of the study is to evaluate the in vitro formation of Cement disks (diameter = 6 mm) impregnated with gentamicin and colistin were submerged in bacterial suspensions of Methicillin-resistant Introduction
Materials and methods
High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing periprosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians towards alternative antimicrobial formulations to the routinely used antibiotics. To date, few studies simultaneously investigated the elution properties of a broad range of antibiotics. The aim of thepresent All the ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing overtime, and elution curves strictly adhered to a non-linear regression analysis formula. Among aminoglycosides, commonly addressed as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, commonly used to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution in comparison with teicoplanin. Clindamycin, that can be associated with aminoglycosides to prepare ALACsshowed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multi-drug resistant bacteria. The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics notroutinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent an useful option for physicians to eradicate PJIs.
Tapered cementless femoral components have been used in total hip arthroplasty (THA) constructs for more than 20 years. The Synergy femoral component was introduced in 1996 as a second generation titanium proximally porous-coated tapered stem with dual offsets to better restore femoral offset at THA (Figure 1). The purpose of this study was to evaluate the outcome of the authors' experience using the Synergy stem at minimum 15 years of follow-up. We retrospectively reviewed a consecutive series of 102 patients (112 hips) who underwent surgery between November 1996 and October 1998 for primary THA using cementless Synergy stem with a minimum 15-years follow-up. The mean age at the time of surgery was 61 years, and the mean duration of follow-up was 16.3 years. Seventeen patients were lost at FU (8 died before the 15 years mark, 8 changed residency, 1 not willing to be seen) with no problems related to the replaced hip. Ninety-four hips in 85 patients were available for clinical and radiologic analysis. Clinical results of the 94 THAs with more than 15 years of follow-up were assessed preoperatively and postoperatively at 5, 10 and 15 years by means of standard evaluation tools: SF12, WOMAC and Harris Hip Score. Thigh pain frequency and intensity were also recorded. Radiographic analysis (Figure 2) was focused on stem alignment, bone ingrowth, radiolucent lines presence, width and progression, stress-shielding and heterotopic ossification (HTO). Student paired test and Kaplan-Meier survival analysis were used for statistical analysis.Background
Material and methods
Few studies have evaluated at a medium-term follow-up the use of semiconstrained reverse shoulder arthroplasty (RSA) for primary glenohumeral osteoarthritis, massive rotator cuff tear, or cuff tear arthropathy excluding any other shoulder disease. Moreover, data on patients' quality of life after this surgery are lacking. In this prospective cohort study, 80 patients were evaluated after an RSA for either primary osteoarthritis, massive rotator cuff tear, or cuff tear arthropathy with the Constant-Murley score (CMS), ROM, and Short Form Health Survey (SF-36). A radiologic assessment was performed pre- and postoperatively.BACKGROUND:
METHODS:
Modern total hip arthroplasty (THA) has shown a great improvement in pain, function and range of motion of patients but data on patients' quality of life after this surgery as assessed by validated tools are lacking. In this cohort study we evaluated the quality of life and functionality of 250 patients an average of 16 years (11–23) after THA using the SF-36 questionnaire, the Harris Hip Score, the WOMAC score, the Functional Comorbidity Index, and a study specific questionnaire. Models of multiple stepwise linear and logistic regression analysis were constructed to evaluate the relationships between the explanatory variables and the functional outcomes.BACKGROUND:
METHODS:
The removal of cement debris at the time of primary and revision joint replacement has been facilitated through the introduction of coloured bone cements. Up to date, few studies have evaluated the effect of methilene blue dye on physical, mechanical and pharmacological properties of cements. In this light, we evaluated the effects of adding methylene blue to bone cement with or without antibiotics (gentamicin, vancomycin or both). The addition of methylene blue to plain cement significantly decreased its mean compression (95.4±3 MPa vs 100.1±6 MPa, p = 0.03) and bending (65.2±5 MPa vs 76.6±4 MPa, p < 0.001) strengths, mean setting time (570±4 seconds vs 775±11 seconds, p = 0.01), as well as its mean elastic modulus (2744±97 MPa vs 3281±110 MPa, p < 0.001). Bending resistance decreases after the supplementation of the coloured cement with vancomycin and gentamicin (55.7±4 MPa vs 65.2±5 MPa, p < 0.001). The release of antibiotics from the bone cement was significantly decreased by the methylene blue. Indeed, the release of gentamicin alone was 385.5±26 μg in comparison to 228.2±24 μg when the methylene blue was added (p < 0.001), while the release of gentamicin in combination with vancomycin was 613±25 μg vs 498.5±70 μg (p = 0.018) when the dye was added to the same formulation. With this study we demonstrated several theoretical disadvantages of the antibiotic-loaded bone cement coloured with methylene blue, although caution should be exercised in transferring our findings to the clinical context. Based on our findings, we do not recommend methylene blue supplementation of PMMA for routine clinical use.
Pure tantalum has been proposed in orthopaedic surgery. Its chemical and physical properties have been widely studied in the past. From pure tantalum is obtained a spongy structure (Trabecular Metal Technology: TMT) that shows a full thickness porosity which is 2–3 times higher compared to other surfaces available for bone ingrowth with a three-dimensional porous arrangement in rough trabeculae. Pores (average diameter of 650 mm) are fully interconnected and represent 75–80% of the whole volume. TMT acetabular components have an elliptical shape and have an irregular external surface which both allow an optimal mechanical fit. We retrospectively reviewed 212 cases of monoblock porous tantalum acetabular cup (Hedrocel, Stratec) implanted between 1999 and 2003 in a single centre with a minimum follow-up of 9–10 years; There were 98 men and 114 women, with an average age of 65 years. They all underwent primary or revision total hip arthroplasty or to acetabular component revision alone. In all patients a monoblock porous tantalum acetabular component with polyethylene directly compression molded into cup, with or without peripheral holes for screws, was implanted. In all primary procedures the same femoral stem (Synergy, Smith and Nephew) was implanted. All patients were evaluated with a clinical examination (Harris Hip Score: HHS) and with standard radiographs of the pelvis preoperatively and 1, 3, 6 months and yearly postoperatively. The stability of the acetabular cup was determined by modified Engh's criteria. The HHS score improved from 42 preoperatively to 94 after one year; at 13 years follow-up it was 95. The subjective outcome was widely satisfying, with the majority of patients experimenting good functional recovery and return to daily activities. Osteointegration of the acetabular component was present in all X-rays controls at one year after surgery. All post-operative evidence of residual bone loss (geodes, bone defects in revisions and in displasia) were no more radiographically evident after 1 year postoperatively as the host bone quickly filled these gaps. We did not observe osteolysis nor progressive radiolucent lines at the latest follow-up. None of the cups was revised, except 3 cases, revised for infection. Both clinical and radiographic results are the same or even superior to those of coated implants. Our experience confirms that trabecular metal tantalum cups can avoid the formation of bone-implant interface membrane and consequently can avoid implant loosening. The most important advantages of TMT monoblock cups are: no potential for polyethylene backside wear, prevention of loosening and osteolysis, increased early fixation via friction, improved late biological stability, maximum bone-implant contact. High biocompatibility of porous tantalum and its elastic modulus very close to bone influence positively earlier and wider osteointegration of the implant. Larger series are needed to confirm the positive our preliminary results.
Coloured bone cements have been introduced to
make the removal of cement debris easier at the time of primary and
revision joint replacement. We evaluated the physical, mechanical
and pharmacological effects of adding methylene blue to bone cement
with or without antibiotics (gentamicin, vancomycin or both). The
addition of methylene blue to plain cement significantly decreased
its mean setting time (570 seconds (
The purposes of the present study were to assess the outcome of surgery for carpal tunnel syndrome (CTS), to evaluate histological findings of subsynovial connective tissue (SSCT) of patients with CTS in comparison with a control group, and to assess whether the histologic appearance of the flexor tenosynovium is correlated with clinical history, preoperative or postoperative physical examination, general health, symptoms and function as assessed by validated tools, or nerve conduction studies.
The choice to use alumina in the manufacture of a low-wear THR bearing made by Boutin and its co-workers has proven its effectiveness in almost 35 years of clinical use. A continuous development process aimed to improve mechanical properties led to today’s materials that exhibit extreme high reliability. The recent introduction in clinical use of alumina matrix composites represents the latest evolution of alumina that thanks to high hardness, toughness, and bending strength allow to manufacture new design of ceramic components. Composites obtained introducing zirconia in the alumina matrix, known as Zirconia Toughened Alumina (ZTA) are candidate for use in THA bearings from a long time. A real breakthrough was represented by alumina ceramics toughened both by zirconia both by platelets nucleated in-situ during sintering (Zirconia-Platelet Toughened Alumina - ZPTA). The chemical composition and the microstructure of ZPTA were optimised to achieve a ceramic material joining strength of more than 1200MPa, Vickers hardness 1975, fracture toughness of 6,5 MPa m-1/2, andextremely low wear also in the most severe simulator tests performed in microseparation mode The paper reviews the improvements introduced in the technology of ceramic for arthoplasty, and their effects on the microstructural properties and on the performances of the past and actual generation of ceramic for THR bearings, and summarise the results obtained in the development of alumina matrix composites.
Patella resurfacing in revision total knee arthroplasty is a controversial issue. While performing revision TKA we must consider some different situations: previously resurfaced patella or not, in case of resurfaced patella, if it is fix or loosened, in case of loosened patella is there a bone loss or not. If patella wasn’t previously resurfaced, we can preserve natural patella performing at least a regularization of its osteophytes, or we can realize a primary resurfacing. If patella was previously resurfaced and still well fixed, we preserve domed component if not grossly damaged. Its revision is performed if it is damaged or not congruent. If patella was previously resurfaced and loosened the two possibilities are the revision or the retention of the bony patella. In case of previously resurfaced and loosened patella, with severe bone loss, we can preserve the bony shell, or we can realize revision with the use of cortical grafting or we can performa patelloplasty, or complete patellectomy. Finally, in these cases it’s possible the revision with tantalum patella. Outcomes of patella resurfacing in revision total knee arthroplasty are usually fair: low functional and pain scores, quadricipite leverage loss, worse patellar tracking, anterior pain, patellar fractures, knee stiffness.
Zirconia has considered a good material for manufacturing of ball heads in total hip replacement due to high mechanical properties of this ceramic material. However in the literature the problem of heads biocompatibility is still debated. The Authors reported their experience in ten years of research on the biological properties of this material. In vitro tests were performed onto materials in form of powders, analyzing the inhibitory effects on human lymphocyte mitogenesis, and in form of plates measuring adhesion and spreading of 3T3 fibroblasts. A mutagenic test was also performed. In vivo tests were performed by injection of powders in mice and evaluating the survival of animals according to ASTM F – 750. We also inserted ceramic in form of cylinders into proximal tibial metaphysis of NZW rabbits and analysed local and systemic reaction due to material diffusion. We also developed a system of production of Zirconia particles by inserting ceramics under patellar tendon of NZW rabbits. In vitro tests showed that Zirconia powders and plates induced a similar effect of Alumina ones; no mutagenic effect were observed using our samples, demonstrating that Zirconia has no carginogenic effects. In any case the diffusion of particles didn’t show modifications into internal organs (lung, kidney, liver, spleen) of mice and rabbits. In time (one year after operation) the connective tissue present at bone ceramic interface is transformed into lamellar bone. Our experience demonstrates that Zirconia may be considered a good material for prosthetic implants.
The Authors analysed two cases of catastrophic failures of Total Hip Prostheses due to the disruption of the PE inlay and the Ti-alloy metal back of the acetabular components. In the cases reported the PE inlay (4 mm in thickness) was coupled with a 32 mm in diameter Alumina ball heads. At time of revision the alumina ball heads showed many black marks due to the contacts with the Ti-alloy metal back. The sockets showed severe damages, concentrated in the superolateral zone. The PE inlays were disrupted. Almost a third of the metal back is missing. A large metallosis was also visible in the membrane at the interface between implant and bone. Histologic sections showed a large amount of metallic debris in a pseudovillous membrane. At higher magnification oligonuclear cells in a rich in vessels stroma were in contact with metal particles. PE debris with the characteristic birifrangent aspect to the polarised light microscope was contained into polynuclear giant cells. SEM showed that the size of 25% of particles was less than 1 μm, while the size of 53% of wear debris is in the range from 1 to 5 mm. EDAX confirmed that these particles consisted of Ti alloy. The Authors analysed the possible roles of different factors in the etiology of this cup failures and concluded that in both the cases analysed the initiator of the failure was the size selection of the prosthesis, and in particular the PE thickness, followed by the positioning of the acetabular component. The deformation of the PE inlay leads to rupture of the inlay itself, followed by the direct contact between the Alumina ball head and the titanium alloy cup, causing the disruption of the Ti-alloy metal back, with massive release of wear debris in the surrounding tissues.
Bone Loss is the main problem in failed total hip arthroplasties. Revision surgery must be conformed to the degree of the bone loss. Since 1986, 330 cases of failed THA underwent to revision surgery. Different solutions were adopted according to Paprosky femoral defects classification. In type I, a primary cementless stem was implanted (23%). In type II and IIIa, were proximal fixation is still possible to achieve, Mid PCA-Howmedica (5%) and modular S-ROM-J&
J revision stems (18%) were implanted. In all the other degree of bone loss (IIIb–IV) cementless distal fixation stems, Long PCA-Howmedica (17 %), Wagner-Sulzer (18 %) and modular (MP-Link, Profemur-Wright) (19 %), were used. Patients were clinically and radiographically evaluated by HHS and according to Engh’s criteria. Best results were observed in Type I group (HHS=90). Long and mid PCA stems presented poor clinical (HHS=60) and radiographical results and required re-revision in 15% of cases. Intermediate results were observed in Wagner prostheses. Modular revision stems showed best results although earlier F-U. (HHS=80). Of these, re-revision surgery was performed in two cases, one of which because of infection and the other one due to severe thigh pain. Cementless modular stems seem to be the most suitable technique. Distal fixation associated with proximal fill permit to manage the majority of femoral bone defects minimizing bone grafts. The modular stems, allow to conform the design of the components to the bone defects permitting to achieve primary stability (press-fit), restoring the centre of rotation and muscles tension, reducing pain and restoring hip function.