The Posterior and Lateral approaches are most commonly used for Total Hip Arthroplasty (THA) in the United Kingdom (UK). Fewer than 5% of UK surgeons routinely use the Direct Anterior Approach (DAA). DAA THA is increasing, particularly among surgeons who have learned the technique during overseas fellowships. Whether DAA offers long-term clinical benefit is unclear. We undertook a retrospective analysis of prospectively collected 10-year, multi-surgeon, multi-centre implant surveillance study data for matched cohorts of patients whose operations were undertaken by either the DAA or posterior approach. All operations were undertaken using uncemented femoral and acetabular components. The implants were different for the two surgical approaches. We report the pre-operative, and post operative six-month, two-year, five-year and 10-year Oxford Hip Score (OHS) and 10-year revision rates. 125 patients underwent DAA THA; these patients were matched against those undergoing the posterior approach through propensity score matching for age, gender and body mass index. The 10-year revision rate for DAA THA was 3.2% (4/125) and 2.4% (3/125) for posterior THA. The difference in revision rate was not statistically significant. Both DAA and Posterior THA pre-operative OHS were comparable at 19.85 and 19.12 respectively. At the six-month time point, there was an OHS improvement of 20.89 points for DAA and 18.82 points for Posterior THA and this was statistically significant (P-Value <0.001). At the two, five and 10-year time-points the OHS and OHS improvement from the pre-operative review were comparable. At the 10-year time point post-op the OHS for DAA THA was 42.63, 42.10 for posterior THA and the mean improvement from pre-op to 10-years post op was 22.78 and 22.98 respectively. There was no statistical difference when comparing the OHS or the OHS mean improvements at the two, five and 10-year point. Whilst there was greater improvement and statistical significance during the initial six month time period, as time went on there was no statistically significant difference between the outcome measures or revision rates for the two approaches.
Over 8000 total hip arthroplasties (THA) in the UK were revised in 2019, half for aseptic loosening. It is believed that Artificial Intelligence (AI) could identify or predict failing THA and result in early recognition of poorly performing implants and reduce patient suffering. The aim of this study is to investigate whether Artificial Intelligence based machine learning (ML) / Deep Learning (DL) techniques can train an algorithm to identify and/or predict failing uncemented THA. Consent was sought from patients followed up in a single design, uncemented THA implant surveillance study (2010–2021). Oxford hip scores and radiographs were collected at yearly intervals. Radiographs were analysed by 3 observers for presence of markers of implant loosening/failure: periprosthetic lucency, cortical hypertrophy, and pedestal formation. DL using the RGB ResNet 18 model, with images entered chronologically, was trained according to revision status and radiographic features. Data augmentation and cross validation were used to increase the available training data, reduce bias, and improve verification of results. 184 patients consented to inclusion. 6 (3.2%) patients were revised for aseptic loosening. 2097 radiographs were analysed: 21 (11.4%) patients had three radiographic features of failure. 166 patients were used for ML algorithm testing of 3 scenarios to detect those who were revised. 1) The use of revision as an end point was associated with increased variability in accuracy. The area under the curve (AUC) was 23–97%. 2) Using 2/3 radiographic features associated with failure was associated with improved results, AUC: 75–100%. 3) Using 3/3 radiographic features, had less variability, reduced AUC of 73%, but 5/6 patients who had been revised were identified (total 66 identified). The best algorithm identified the greatest number of revised hips (5/6), predicting failure 2–8 years before revision, before all radiographic features were visible and before a significant fall in the Oxford Hip score. True-Positive: 0.77, False Positive: 0.29. ML algorithms can identify failing THA before visible features on radiographs or before PROM scores deteriorate. This is an important finding that could identify failing THA early.
Disease specific or generic Patient Reported Outcome Measures (PROMs) can be completed by patients using paper and postal services (pPROMS) or via computer, tablet or smartphone (ePROMs) or by hybrid data collection, which uses both paper and electronic questionnaires. We have investigated whether there are differences in scores depending on the method of PROMs acquisition for the Oxford Hip Score (OHS) and the EQ-5D scores, at one and two years post operatively. Patients for this study were identified retrospectively from a prospectively compiled arthroplasty database held at the study centre. Patient demographics, mode of preferred data collection and pre- and post-operative PROMs for Total Hip Replacements (THRs) performed at this centre between 1st January 2018 and 31st December 2018 were collected. During the study period, 1494 patients underwent THRs and had complete one and two-year PROMs data available for analysis. All pre-operative scores were obtained by pPROMS. The average OHS and EQ-5D pre-operatively scores were 19.51 and 0.36 respectively. 72.02% of the patients consented to undertake post-operative questionnaires using ePROMs. The remaining 27.98% opted for pPROMS. The one and two-year OHS for ePROMS patients increased to 41.31 and 42.14 while the OHS scores for pPROMS patients were 39.80 and 39.83. At the one and two-year post-operative time intervals, a Mann-Whitney test showed statistical significance between the modes of administration for OHS (P-Value =0.044 and 0.01 respectively). The one and two-year EQ-5D for ePROMS patients increased to 0.83 and 0.84 while the EQ-5D scores for pPROMS patients were 0.79 and 0.81. The P-Value for Mann-Whitney tests comparing the modes of administration for EQ-5D were 0.13 and 0.07 respectively. Within Orthopaedics, PROMs have become the most widely used instrument to assess patients’ subjective outcomes. However, there is no agreed mode of PROMs data acquisition. While we have demonstrated an apparent difference in scores depending on the mode of administration, further work is required to establish the influence of potentially confounding factors such as patient age, gender and familiarity with computer technology.
Clinical decision-making is often based on evidence of outcome after a specific treatment. Surgeons and patients may, have different perceptions and expectations of what to achieve following a Total Hip Replacement (THR). Several studies have shown that unfulfilled expectations are a principal source of patient dissatisfaction and patients are typically overly optimistic with regards to expected outcomes following surgery. Published data on clinical and functional outcomes show that persistence of symptoms, such as pain, and failure to return to preoperative levels of function are normal. To measure patient's expectations we undertook prospective study reviewing patients' expectations in 1800 THRs over a 21-year period (1997–2018). Of the whole cohort, 48.98% patients reported they wanted a THR to overcome unbearable pain. 11.75 % wanted a THR to be able to walk without a limp. 9.69% wanted to a THR to increase walk endurance. 61.97% reported it was extremely important to decrease pain following a THR. In 2001, the most important reason for a THR reported by patients was to relieve unbearable pain and this remained the same most important reason in 2018. This result was also statistically significant with a p-value of 0.001. 80.36% reported they anticipated ‘no pain’ after recovery from a THR, 16.75% reported they anticipated ‘some pain’ and 2.89% reported they anticipated ‘extreme pain’ following a THR. 74.71% reported it was extremely important to increase their ability to undertake normal activities. 22.06% reported it was very important, 2.40% reported it was moderately important, 0.55% slightly important and 0.28% reported it was not all to important to increase their ability to undertake normal activity. In conclusion patients' want to reduce their pain, walk normally and increase their level activities. Differences in expectation fulfilment may be due to unrealistic expectations. To achieve optimal outcome managing patient expectations is vital.
For total hip arthroplasty (THA), cognitive training prior to performing real surgery may be an effective adjunct alongside simulation to shorten the learning curve. This study sought to create a cognitive training tool to perform direct anterior approach THA, validated by expert surgeons; and test its use as a training tool compared to conventional material. We employed a modified Delphi method with four expert surgeons from three international centres of excellence. Surgeons were independently observed performing THA before undergoing semi-structured cognitive task analysis (CTA) before completing successive rounds of electronic surveys until consensus. The agreed CTA was incorporated into a mobile and web-based platform. Forty surgical trainees (CT1-ST4) were randomised to CTA-training or a digital op-tech with surgical videos, before performing a simulated DAA THA in a validated fully-immersive virtual reality simulator.Background
Methods
Patients need to know the benefits, risks and alternatives to any proposed treatment. Surgeons discussing the risk of a revision procedure becoming necessary, after a hip replacement can draw upon the orthopaedic literature and arthroplasty registries for long-term implant survival. However, early revision is required in a minority of cases. We have investigated the probability for revision hip replacement patients in terms of time-point and indication for revision. Of the 9,411 Primary Total Hip Replacements (THR), undertaken by 22 surgeons, over an eleven-year period, between January 2004 and March 2015, 1.70% (160) were subsequently reported to the National Joint Registry (NJR) as revised. Each revision case was reviewed under the supervision of senior hip specialist consultants. The modes of failure of were identified through clinical, laboratory and imaging (x-rays, CT, MRI and Isotope scans) studies. The revision rate for THRs was 0.58% in the first year. This was statistically higher than all subsequent years, P-Value <0.001. There was no statistical difference between any pair of subsequent years. Thereafter, the average revision rate was 0.30% per annum. The odds ratio for revision during the first post–operative year against the subsequent year average was 1.67. The indications for the early hip revisions in the first three years were infection, dislocation and peri-prosthetic fracture. The data from this study can help better inform patients of the revision rates after a primary THR and allow surgeons to develop implant surveillance strategies among high-risk patients.
We have investigated whether the pattern of subchondral acetabular cyst formation reflects hip pathology and may provide a prognostic indicator for treatment. A single surgeon series of sequential hip arthroscopies was reviewed to identify the most recent 200 cases undertaken on a previously un-operated joint with pre-operative plain radiographs and computed tomography or magnetic resonance scan available for review. Also, serial “non-arthritic hip scores” (NAHS) recorded pre-operatively, at 6 weeks and 3 months post-surgery. The acetabular Lateral Centre Edge Angle, the Acetabular Index, the FEAR index and the Kallgren and Lawrence grade were determined. All images were reviewed by two independent assessors and divided into four groups according to acetabular subchondral cyst distribution. No association was identified between gender and patient reported outcomes. SDC patients were significantly younger than the other three groups (p <0.001). At three months after surgery, the average increase of the NAHS in the four groups was 25.3, 23.5, 4.2 and 4.9 respectively. Acetabular dysplasia was identified in 72% of the SDC group compared to 18%, 16% and 33% in NC, SPC and MC groups. Degenerative change was identified in 86% of the MC group compared to 18%, 40% and 41% of the NC, SPC and SDC groups. The early patient reported outcome following hip arthroscopy was significantly affected by the location and number of acetabular subchondral cysts. A Solitary Dome Cyst is indicative of underling hip dysplasia. Multiple Cysts are indicative of degenerative disease. The majority of patients in these groups have poor three-month outcomes after hip arthroscopy.
Total Hip Replacement (THR) is widely assumed to resolve sleep disturbance commonly experienced by individuals with hip osteoarthritis (OA). We report a study of 329 THRs with mean age of 71.9 years comparing pre-operative and one and two year post-operative patient reported outcomes for sleep disturbance to determine the veracity of this expectation. Data was collected from the validated Oxford Hip Patient Reported Questionnaire. Specifically, Question 12: “During the past four weeks, have you been troubled by pain from your hip in bed at night?” Answers to the question were multiple choice: No nights (4 points), Only 1 or 2 nights (3 points), Some nights (2 points), Most nights (1 point) and Every Night (0 points) Pre-operatively, the mean score for patients with hip OA was 1.2/4. This increased to 3.5 at one year and was also maintained at two years. The pre- to post-operative improvement was significant at both one and two years for THR with p <0.00001. Pre-operatively, only 6% of patients with arthritic hips reported that they were never woken from sleep because of their painful hip. One year after THR 72% always enjoyed pain free sleeping and at two years this had risen to 75%. When patients who only experienced disturbance one or two nights per month were included, the three figures increased from 13% to 83% and 83% respectively. The study confirms that sleep disturbance affects over 90% of patients with arthritic hip joints. Over 80% of THR patients will enjoy sleep that is seldom or never disturbed by their artificial hip. The improvement achieved by THR occurs within a year of surgery and is preserved at two years. In this regard, hip replacement is a highly effective intervention.
The Metasul articulation was introduced in the early 1990's. It comprises a 28mm forged, cobalt-chrome head and a forged metal inlay, set into the polyethylene element of the acetabular component. During the 1990's and early 2000's anatomic sized MoM articulations were re-introduced for hip resurfacing and stemmed implant designs. Adverse tissue reactions to metal debris and corrosion products subsequently led to a decline in MoM usage. Between January 1995 and December 1998, 133 hips underwent primary THR using the Metasul 28mm bearing. Patients were routinely sent an annual postal Oxford Hip Score (OHS) and radiographs were obtained from the second post-operative year. We have retrospectively reviewed the clinical and radiographic dataset following the 15 year follow-up time point.Introduction
Materials & Methods