Satisfaction following total knee replacement (TKR) surgery remains suboptimal at around 80%. Prediction of factors influencing satisfaction may help manage expectations and thus improve satisfaction. We investigated preoperative variables that estimate the probability of achieving a successful surgical outcome following TKR in several outcomes important to patients. 9 pre-operative variables (easily obtained on initial consultation) of 591 unilateral TKRs were selected for univariant then multivariant analyses. These variables included Oxford Knee Score (OKS), age, sex, BMI, ASA score, pain score, mobility aids, SF12 PCS & SF12 MCS. Using the relative predictive strengths of these variables we modeled the probabilities a successful result would be achieved for 6 patient reported outcomes at 3 and 12 months following surgery. These were ‘Excellent/good OKS’, ‘Mild/no pain’, ‘Walking without/at first a limp’, ‘No/little interference with normal work’, ‘Kneeling with little/no difficulty’ and ‘Satisfaction with surgery’.Introduction & aims
Method
The risk of hip dislocation after revision total hip arthroplasty is up to 20% following surgery for periprosthetic fractures. A technique was developed by the senior authors, involving a transtrochanteric osteotomy and superior capsulotomy to attempt to minimise this risk(1). This prospective study examines a cohort of 40 patients undergoing this novel technique, which involves extending the fracture proximally to the tip of the greater trochanter. This is then extended into the soft tissues in the mid lateral plane as a split of the glutei and a minimally superior capsulotomy (preserving the anterior and posterior capsule). This allows for revision of the femoral component, and retention of the socket and liner. The outcomes of interest to the authors were dislocation rates, clinical outcome measured using the Oxford hip score. These were assessed along with X-ray imaging at 1, 2 and 5-year intervals to confirm fracture union and measure stem subsidence.Introduction
Methods
We identified 26 tibial tubercle osteotomies (TTOs) performed in 23 revision knee arthroplasties between 2009 and 2013. Average age at last operation was 66 (33–92). Mean follow-up period was 14 months (3–33). Eleven TTOs were performed in 10 knees for single stage revisions and 15 TTOs were performed in 13 knees for 2 stage revisions in the setting of deep infection. In this infected subset 11 patients had a TTO performed at the first stage. This osteotomy was left unfixed to avoid leaving metalwork in a potentially contaminated wound, reopened, and then definitively secured with screws at the second stage. Our technique involves fashioning a long 7×1cm tibial tuberosity osteotomy without a proximal step-cut. All osteotomies united with no fractures. Minor proximal migration was noted in one case associated with screw loosening. There was no proximal migration noted in the 2 stage cases where the osteotomy had been left initially unfixed. There were no extensor lags. We conclude that TTO is a safe and reproducible procedure when adequate exposure cannot be obtained in revision knee arthroplasty. In 2 stage revisions sequential osteotomies does not decrease union rates and leaving the osteotomy unfixed after the first stage does not cause any issues.
Eligible patients were randomly allocated to PMI or standard intramedullary jigs. Smith and Nephew's patient specific cutting blocks (Visionaire) were used for PMI. Postoperative component positioning was investigated using the ‘Perth CT protocol’. Deviation of more than 3° from the recommended position was regarded as an outlier. Exact Mann-Whitney U test was used to compare component positioning and difference in proportion of outliers was calculated using Chi Squared analysis. Fifty-five knees were enrolled in the standard instrumentation group and fifty-two knees in the PMI group. Coronal femoral alignment was 0.7 ± 1.9° (standard) vs 0.5 ± 1.6° (PMI) (P=0.33). Outliers 9.4% vs 7.4% (P=0.71). Coronal tibial alignment was 0.4 ± 1.5° (standard) vs 0.6 ± 1.4° (PMI) (P=0.56). Outliers 1.9% vs 1.9% (P=0.99). Sagittal femoral alignment was 0.6 ± 1.5° (standard) vs 1.3 ± 1.9° (PMI) (P=0.07). Outliers 3.8% vs 13.2% (P=0.09). Tibial slope was 1.7 ± 1.9 ° (standard) vs 1.8 ± 2.7° (PMI) (P=0.88). Outliers 13.2% vs 24.1% (P=0.15). External rotation of femoral component was 0.6 ± 1.4° (standard) vs 0.2 ± 1.8° (PMI) (P=0.14). Outliers: 3.8% vs 5.6% (P=0.66). Compared to standard intramedullary jigs, patient matched instrumentation does not improve component positioning or reduce alignment outliers.
We treated 34 patients with recurrent dislocation of the hip with a constrained acetabular component. Roentgen stereophotogrammetric analysis was performed to assess migration of the prosthesis. The mean clinical follow-up was 3.0 years (2.2 to 4.8) and the radiological follow-up was 2.7 years (2.0 to 4.8). At the latest review six patients had died and none was lost to follow-up. There were four acetabular revisions, three for aseptic loosening and one for deep infection. Another acetabular component was radiologically loose with progressive radiolucent lines in all Gruen zones and was awaiting revision. The overall rate of aseptic loosening was 11.8% (4 of 34). Roentgen stereophotogrammetric analysis in the non-revised components confirmed migration of up to 1.06 mm of translation and 2.32° of rotation at 24 months. There was one case of dislocation and dissociation of the component in the same patient. Of the 34 patients, 33 (97.1%) had no further episodes of dislocation. The constrained acetabular component reported in our study was effective in all but one patient with instability of the hip, but the rate of aseptic loosening was higher than has been reported previously and requires further investigation.
Compartment syndrome is a rare complication of total knee arthroplasty that requires early recognition and prompt decompression in order to prevent long-term disability. We have found only one previous case report in the literature. We present a series of seven cases from four hospitals and five surgeons. Six of the cases resulted in the loss of at least one compartment, and one resulted in amputation. Four of the cases resulted in legal action. We suggest that important risk factors contributing to the development of this condition include complex surgery, soft-tissue compromise, previous surgery, and possibly vascular disease. Delay in the diagnosis and hence delay in decompression was common in our series, and in five cases appeared to be related to the use of a postoperative epidural infusion for pain relief. The presence of associated neurological compromise may have also been a significant factor in the delay to diagnosis in two cases.
Eleven patients had a lateral closing wedge osteotomy; the medial opening wedge was performed in a case of leg shortening. Mean operation duration was 72 minutes (60–90). The graft was fixed with fibrin glue in all cases, and augmented with stitches or vicryl pins in five cases. Mean defect size was 6.2cm2 (2–12). There were three complications: one DVT, a haemarthrosis and a graft detachment. Average follow-up was 16 months. MRI scans at three months show oedematous tissue at the defect sites, contrasting with the fluid filled defects seen preoperatively. Scans at one-year show hyaline-like cartilage infill with similar signal characteristics to native hyaline cartilage. Six minute walk test and knee injury and osteoarthritis outcome score indicate significantly improved functional capacity at six months and one year.
Open operative treatment compared with non-operative treatment was associated with a lower risk of re-rupture (odds ratio (OR) = 0.25, 95% confidence interval (CI) = 0.1–0.6, p=0.003) but a higher risk of other complications including infection, adhesions and disturbed sensibility (OR = 14.1, 95%CI = 6.3–31.7, p<
0.00001). Open versus percutaneous operative surgical repair was associated with a longer operation duration and higher risk of infection (OR = 12.9, 95%CI = 1.6–105.6, p=0.02). Patients splinted with a functional brace rather than a cast post-operatively tended to have a shorter in-patient stay, less time off work, quicker return to sporting activities and fewer reported complications (p=0.0003). Because of the small number of patients involved no definitive conclusions could be made regarding different operative techniques and different non-operative regimes.
Minimum follow-up was 3 years in group 1 and 1.5 years in group 2. There were 3 dislocations in group 1, and none in group 2. There were 2 re-operations in both groups. The relative improvement in WOMAC scores was significantly greater in group 2 at 3 months and 1 year (P<
0.05).
We carried out a blinded prospective randomised controlled trial comparing 2-octylcyanoacrylate (OCA), subcuticular suture (monocryl) and skin staples for skin closure following total hip and total knee arthroplasty. We included 102 hip replacements and 85 of the knee. OCA was associated with less wound discharge in the first 24 hours for both the hip and the knee. However, with total knee replacement there was a trend for a more prolonged wound discharge with OCA. With total hip replacement there was no significant difference between the groups for either early or late complications. Closure of the wound with skin staples was significantly faster than with OCA or suture. There was no significant difference in the length of stay in hospital, Hollander wound evaluation score (cosmesis) or patient satisfaction between the groups at six weeks for either hips or knees. We consider that skin staples are the skin closure of choice for both hip and knee replacements.
Patients were scored pre-operatively and followed up prospectively. The only special instruments required are two large curved Hohmann retractors and an angled cup introducer.
Forty-two percent of patients were male. Mean age was 68.9 years (42–90) and BMI 26 (14–39). Average operation time was 64.1 minutes and anaesthetic time 92.5 minutes. Mean fall in haemoglobin in the first 24 hours was 2.3g/dl. Mean incision length was 7.4cm. Follow-up was a minimum of one year (range 12–29 months). There was a highly statistically significant improvement in WOMAC and SF-36 scores at three and 12 months post-operatively (p<
0.0001). Early medical complications occurred in 12 patients, including two superficial infections, all of which resolved. There were no peri-prosthetic fractures and importantly, no dislocations. There were two re-operations: one revision for cup displacement and one washout for deep infection.
In our clinical series, over 30% of patients experienced paraesthesia and some experienced a burning dysaesthesia in the distribution of the LFCN.
In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.