Total hip arthroplasty (THA) has been efficacious for treating hip fractures. However, in these patients with fractures a widely variable prevalence of dislocation has been reported, partly because of varying durations of follow-up for this specific end-point. The purpose of the present study was to determine the risk of dislocation as a function of time after total hip arthroplasty in these patients with fractures and to investigate if constrained liners influence the cumulative risk of dislocation. Between 2000 and 2005, 425 patients with neck fracture underwent primary THA using a constrained acetabular liner (Cemented retentive cup, Groupe lépine, Genay, France). The results of these 425 constrained acetabular liners were compared with 380 THA without constrained liners performed for neck fractures between 1994 and 1999 in the same hospital. All patients were followed for a minimum of 5 years for radiographic evidence of implant failure. The patients were followed at routine intervals and were specifically queried about dislocation. The cumulative risk of dislocation was calculated with use of the Kaplan-Meier method. For patients without constrained liners, the cumulative risk of a first-time dislocation was 5% at one month and 12% at one year and then rose at a constant rate of approximately 2% every five years to 17% at five years, 19% at ten years, 21% at 15 years for patients who were alive and had not had a revision by that time. For patients with constrained liners, the cumulative risk of a first-time dislocation was 1% at one month, 2% at one year and then did not changed at 5 years and at 10 years for patients who were alive and had not had a revision by that time. Multivariate analysis revealed that the relative risk of dislocation for female patients (as compared with male patients) was 2.1 and that the relative risk for patients who were 80 years old or more (as compared with those who were less than 80 years old) was 1.5. Two underlying diagnoses - cognitively impaired patients or neurologic desease—were also associated with a significantly greater risk of dislocation. At minimum 7 year follow up (range 5 10 yrs), there were 8 radiographic failures (dislocations) of the 425 constrained liners (2%), and no loosenings were noted. The cumulative long-term risk of dislocation for patients with hip fractures is considerably greater than has been reported in short-term studies. The incidence of dislocation is highest in the first year after arthroplasty and then continues at a relatively constant rate for the life of the arthroplasty. Patients at highest risk are old female patients and those with a diagnosis of neurologic desease. Constrained liners in these patients is an efffective technique to prevent post operative hip dislocation.Results
Conclusions
In a society dependent upon the motor car, impaired driving ability is a significant disability which may affect patients with total knee replacement during the postoperative rehabilitation. Recently, there has been much interest in minimally invasive surgery for total knee arthroplasty (TKA). This study evaluated the hypothesis that a minimally invasive technique using a small incision (7 to 10 cm), and a minimal quadriceps muscle splitting without eversion of the patella (MIS approach) would have a beneficial effect on driving reaction time. 15 patients undergoing a primary TKA with the MIS approach were compared with 15 TKAs using a standard approach. An experimental car was used to measure the force and timing of pressure by the foot on accelerator and break pedals. The mean reaction time for normal adults was 0.442 s to go from the accelerator to the brake pedal. This time falls well within the code guideline of 0.7 s. The driving reaction times of the patients with knee arthroplasty were measured at one, two and three months after the operation. The ability to perform an emergency stop was assessed as the time taken to achieve a brake pressure of 100 N after a visual stimulus.The patients have an actual follow-up of 2 years. A clinical and radiological evaluation was performed. Radiographic analysis included evaluation of postoperative alignment variables and progressive radioluciencies. Over all 27 among the 30 knees have good and excellent objective knee Society Scores and patient satisfaction indices. The patients in the MIS group had a statistically shorter time until they could straight leg raise, used less epidural analgesia, used less overall analgesics and had a more rapid regaining of flexion. Patients with standard approach and technique for total knee replacement recovered sufficient knee function to return to driving at only three months after the operation according to the time and the force necessary to the brake pedal. Patients with mini invasive surgery approach have recovered sufficient knee function to return driving at one month after the operation. There was no significant difference in alignment of implants and in alignment of the knee between the two groups. Three knees had radioluciencies (two with a standard incision and one with a MIS approach). Using a small incision without patellar eversion does not jeopardize the alignment of the implants and improves postoperative rehabilitation.