Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 20 - 20
17 Jun 2024
Jagani N Harrison W Davenport J Karski M Ring J Smith R Clough T
Full Access

Aims

Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure.

Methods

All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 2 - 2
4 Jun 2024
Townshend D Bing A Clough T Sharpe I Blundell C Davenport J Davies H Davis J Dhar S Goldberg A Karski M Hepple S Kakwani R McKinley J Murty A Ragland M Shalaby H Smith R Taylor H
Full Access

Introduction

This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales.

Methods

Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 47 - 54
1 Jan 2019
Clough T Bodo K Majeed H Davenport J Karski M

Aims

We report the long-term clinical and radiological outcomes of a consecutive series of 200 total ankle arthroplasties (TAAs, 184 patients) at a single centre using the Scandinavian Total Ankle Replacement (STAR) implants.

Patients and Methods

Between November 1993 and February 2000, 200 consecutive STAR prostheses were implanted in 184 patients by a single surgeon. Demographic and clinical data were collected prospectively and the last available status was recorded for further survival analysis. All surviving patients underwent regular clinical and radiological review. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scoring system. The principal endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan–Meier survival curves were generated with 95% confidence intervals and the rate of failure calculated for each year.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_21 | Pages 25 - 25
1 Dec 2017
Ring J Davenport J Karski M Smith R Divercha H Clough T
Full Access

Introduction

Traditional treatment for end-stage ankle arthritis has been ankle arthrodesis, however ankle arthroplasty is becoming an accepted alternative.

The Zenith Ankle (Corin, UK) is 3rd generation implant with a mobile bearing design. In the NJR 2016 report, the Zenith was the commonest ankle prosthesis implanted in the UK. However, compared to other ankle implants, there's little published data on its performance and survival. The aim of this study was to analyse outcome in a consecutive series from a non-designer centre.

Method

We conducted a retrospective review of a consecutive series of 118 Zenith Ankle replacements implanted in our Unit (December 2010 to May 2016). Data was collected from our National Joint Registry entries, research databases, patient notes, PACS and PROMS.