header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 27 - 27
1 Sep 2012
Alta T Coghlan J Troupis J Bell S
Full Access

The purpose of this study was to determine if the use of a new 4 Dimensional CT scan aids the clinician in defining the size and area of the scapular bone to be removed arthroscopically in patients with Snapping Scapular Syndrome.

From January 2009 – January 2011 nine consecutive patients with Snapping Scapular Syndrome were included. In six patients, (mean age 21±5 years, range 15–27) conservative treatment failed. These patients were positioned prone and demonstrated their snapping motion during the 7 seconds duration of the scan. The 4D CT machine scans 16 cm volumes in 0.3 seconds. It also scans motion, allowing a 3D reconstruction of the scapulothoracic joint, its’ movements and the dynamic area of impingement of the scapula on the surrounding structures. This scan has already improved arthroscopic removal of the supero-medial angle of the scapula.

The scan showed in one case not only snapping of the superior medial angle of the scapula on the 2nd rib, but also extra bone impinging on the 3rd rib. Another case showed no real impingement but movement of the 2nd and 3rd rib by a tethering structure and a third case demonstrated impingement of the lateral third of the clavicle on the 2nd rib.

The images provided by this new 4D CT scan offer greater pre-operative insight on the pathology in each individual patient with Snapping Scapular Syndrome. Therefore, we feel that it is a valuable addition to the assessment and treatment of these patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 28 - 28
1 Sep 2012
Alta T Miller D Coghlan J Troupis J Bell S
Full Access

The purpose of this study was to determine the motion pattern of the Acromio-Clavicular (AC) joint in a normal shoulder with the use of the new 4 Dimensional CT scan.

From April 2010 till January 2011 fourteen healthy volunteers (4 female, 10 male)(mean age 42±11 years) with no previous history of shoulder complaints participated in this study. The 4D CT machine scans motion, allowing a 3D reconstruction of the shoulder joint and its movements. Patients were positioned supine with their arm elevated 90° in the sagittal plane. During the 7 seconds duration of the scan they adducted their arm at that level and then elevated their arm upwards resisted by the gantry for 4 seconds, in this way simulating the clinical Bell-van Riet test for AC pathology.

In the transverse plane the mean AC joint space measured in the neutral position is 1.8±0.5 mm. While adducting the arm the AC joint narrows 0.0±0.4 mm (with a positive value being narrowing and a negative value widening). On resisted elevation the joint space is narrowed 0.2±0.6 mm. The mean antero-posterior (AP) translation in this same plane is 0.2±2.2 mm on adduction (with a positive value being posterior translation of the clavicle and a negative value anterior translation) and 0.4±2.9 mm on resisted elevation.

The new 4D CT scan demonstrates that the AC joint in a normal shoulder mainly translates in an AP direction, rather than being narrowed or widened, when the arm is adducted (with or without resisted active elevation).


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 302 - 303
1 Jul 2011
Prasthofer A Sloan R Old J Coghlan J Bell S
Full Access

Introduction: The aim of this study was to assess the outcomes of patients with recurrent antero-inferior gle-nohumeral instability with associated antero-inferior glenoid bone loss treated with a specific open stabilisation technique, using intra-substance coracoid bone grafting. It is hypothesised that this method of reconstruction produces low recurrence of instability as well potential for patients to return to high-risk sport.

Methods: 30 shoulders with recurrent anterior dislocation and glenoid bone loss were stabilised with open capsular and labral repair and intra-substance coracoid bone grafting. Motion and stability were assessed by Rowe Stability Score (RSS) with follow-up over 2 years in all cases. American Shoulder and Elbow Score (ASES) and Oxford Stability Scoring (OSS) were also recorded at follow-up. Intention to and actual return to sporting level was assessed. Union of the graft was confirmed by CT scan.

Results: For all 30 shoulders at a mean follow-up time of 2 years 11 months (range 2–5 years) the RSS improved from a mean of 32 to 78.5 post-op. 1 redislocation occurred whilst continuing high-risk sport after 2 years. ASES index at 2 years had a mean of 91.8 whilst the OSS was 18.5. Pre-operatively, 24 patients participated in high-risk sport. 20 intended to return to high-risk sport post operatively. 18 achieved this return without restriction. CT scans were available on 25 shoulders at a mean of 4.5 months after surgery. 1 showed slight resorption of the graft, union was confirmed in 23.

Conclusion: This small sample shows an overall acceptable clinical and radiological outcome at a minimum of 2-year follow-up. These results support the current literature advocating open stabilisation and bone grafting of the glenoid where loss is evident, particularly in the young contact athlete with recurrent instability and high expectations of success.