4D CT SCANS IMPROVE PRE-OPERATIVE PLANNING IN SNAPPING SCAPULAR SYNDROME

Australian Orthopaedic Association and New Zealand Orthopaedic Association (AOA/NZOA) - Combined Annual Scientific Meeting



Abstract

The purpose of this study was to determine if the use of a new 4 Dimensional CT scan aids the clinician in defining the size and area of the scapular bone to be removed arthroscopically in patients with Snapping Scapular Syndrome.

From January 2009 – January 2011 nine consecutive patients with Snapping Scapular Syndrome were included. In six patients, (mean age 21±5 years, range 15–27) conservative treatment failed. These patients were positioned prone and demonstrated their snapping motion during the 7 seconds duration of the scan. The 4D CT machine scans 16 cm volumes in 0.3 seconds. It also scans motion, allowing a 3D reconstruction of the scapulothoracic joint, its’ movements and the dynamic area of impingement of the scapula on the surrounding structures. This scan has already improved arthroscopic removal of the supero-medial angle of the scapula.

The scan showed in one case not only snapping of the superior medial angle of the scapula on the 2nd rib, but also extra bone impinging on the 3rd rib. Another case showed no real impingement but movement of the 2nd and 3rd rib by a tethering structure and a third case demonstrated impingement of the lateral third of the clavicle on the 2nd rib.

The images provided by this new 4D CT scan offer greater pre-operative insight on the pathology in each individual patient with Snapping Scapular Syndrome. Therefore, we feel that it is a valuable addition to the assessment and treatment of these patients.