Failure resulting from a recurrent infection in total knee arthroplasty (TKA) is a challenging problem. Knee arthrodesis is one treatment option, however fusion is not always successful, as there is huge bone defect. The authors reports a new arthrodesis technique that uses a bundle of flexible intramedullary rods and an antibiotic-loaded cement spacer. There were 13 cases of arthrodesis due to recurrent periprosthetic joint infection, which were performed by the first author (WS Cho) at Asan Medical Center in Seoul from 2005 to 2014. All previous prosthetic components were removed and cement was thoroughly excised using a small osteotome. Two stage operation was done in most of cases. After thorough debridement, antibiotics loaded cement was inserted in first stage, flexible intramedullary rods were inserted retrogradely in the femoral side with the knee in flexion under fluoroscopy guidance. After filling the femoral intramedullary canal, the rods were then driven back securely into the tibial medullary canal. We aimed for as much rod length as possible to maximize stability. After 6 weeks of first stage operation, the rods of the femoral and tibial sides were arranged such that they overlapped and interdigitated to maximize mechanical strength, maintain the limb length and keep the rotational alignment. The interdigitating rod ends were tightly fixed using two (or three) cerclage wires. Antibiotic-loaded cement was filled into the knee joint space so that the cement is fit to the irregular contour of the femur and tibia, which was resulted from the severe bone loss. Postoperatively, patients were allowed to weight bear as tolerated.Purpose
Methods
To compare the clinical and radiological results between internal fixation using the proximal femoral nail system and bipolar hemiarthroplasty in reverse oblique intertrochanteric hip fracture in elderly patients. From January 2005 to July 2012, we reviewed 53 patients who had been treated surgically for reverse oblique intertrochanteric fracture and been followed up on for a minimum of 2 years. The patients, all over 70 years old, were divided into two groups for retrospective evaluation: one group was treated with open reduction and internal fixation using the proximal femoral nail system (31 cases), and the other group was treated with bipolar hemiarthroplasty (22 cases).Purpose
Materials and Methods
We evaluated the clinical and radiographic outcomes of cementless bipolar hemiarthroplasty using rectangular cross-section stem for femoral neck fracture in elderly patients more than 80 years of age with osteoporosis. 76(cemented 46, cementless 30) bipolar hemiarthroplasties for femur neck fracture were performed in elderly patients more than 80 years old. The mean follow-up period was 4.3 years (2 to 7 years). The Harris hip score at last follow-up and pre-postoperative daily living activity scale according to Kitamura methods were analyzed clinically. The radiological results were assessed using stability of femoral stem and other complications were evaluated. Results: At last follow-up, there were no significant differences of Harris hip score and daily living activity between two groups. Stem loosening and instability were not observed in cementless arthroplasty. There were 18 cases of osseous fixation in radiologic study. There were 1 case of dislocation and 1 case of superficial infection in cemented arthroplasty and 1 case of deep infection in cementless arthroplasty.Purpose
Material and Methods
To observe the follow-up results of standard cemented bipolar hemiarthroplasty with double loop and tension band wiring technique for treatment of unstable intertrochanteric hip fractures in elderly patients with osteoporosis. From May 2000 to May 2006, 86 cemented bipolar hemiarthroplasties were performed in elderly patients who had unstable intertrochanteric fractures. The mean age at the time of surgery was 82 years old. The average follow-up period were 5.3 years. We evaluated post-operative results after operation by clinical and radiographic methods.Purpose
Materials and Methods
To perform comparative analysis between the results of internal fixation using proximal femoral nail system and bipolar hemiarthroplasty in pantrochanteric hip fracture in elderly patients. From January 2006 to February 2012, we reviewed 43 patients, who were treated surgically for pantrochanterichip fractures, with a minimum of 2 years follow up. The patient's age was older than 70 year old. The patients were divided into three groups and evaluated, retrospectively. The fracture reduction were regarded as satisfactory in S-OR-IF group(17 cases) and unsatisfactory in US-OR-IF group(9 cases) and the other group was treated with bipolar hemiarthroplasty (BHA group, 17 cases.)Purpose
Materials and Methods
To evaluate outcome after cementless bipolar hemiarthroplasties using a standard(tapered, rectangular) stem for the treatment of above type A2 fractures in elderly patients. We reviewed the records of 37 patients who underwent bipolar hemiarthroplasty between February 2006 and Feburuary 2010 in our hospital who were followed for more than two years after surgery. The mean patient age was 73.5 years old (range 64∼88 years old). 16 patients were men, and 21 patients were women. We evaluated the results by analyzing operation time, amount of bleeding, recovery of walking ability, complications and radiologic findings.Purpose
Material and methods
To analyze the effectiveness of a vancomycin impregnated calcium sulfate cement bead insertion after debridement (of) an acute-immediate stage infected hip arthroplasty. Between 2002 and 2008, 13 patients with documented acute-immediate stage infection of hip arthroplasty were reviewed and followed for at least two years postoperatively(average 4.3 years). The preoperative and postoperative clinical and radiologic findings and blood laboratory work were checked. All cases were performed through retention of the implant and massive debridement and saline irrigation. After that a vancomycin impregnated calcium sulfate cement beads was inserted.Purpose
Materials and Methods
Recent reports about the excellent clinical results of unicondylar knee arthroplasty (UKA; also known as unicompartmental knee arthroplasty), by the minimally invasive approach, have encouraged the adoption of the surgical technique. However, friction between metallic prosthetic components resulting from polyethylene wear may result in the development of metallosis and the use of metal implants has become a huge issue in the worlds recently. Here, we report a case in which a patient underwent UKA and developed metallosis in soft tissues and bone adjacent to an implanted artificial joint three years postoperatively.
Recently, several preliminary reports have been issued on the application of computer assistance to bone tumour surgery. Surgical navigation systems can apply three-dimensional images such as CT and MR images to intraoperative visualization. Although CT is better at describing cortical bone status, MRI is considered the best method for defining the extent of marrow involvement for bone tumours and for planning surgical resection in bone tumour surgery. There have been a few reports on the application of MR imaging to navigation-assisted bone tumour surgery through CT–MR image fusion. However, the CT–MRI fusion technique requires additional costs and exposure of the patient to radiation from the preoperative CT, as well as additional time for image fusion. Above all, the image fusion process is a kind of registration (image to image registration) that inevitably leads to registration error. Herein we describe a new method for the direct application of MR images to navigation-assisted bone tumour surgery as an alternative to CT–MRI fusion. Six patients with an orthopaedic malignancy were employed for this method during navigation-assisted tumour resection. Resorbable pin placement and rapid 3-dimensional spoiled gradient echo sequences made the direct application of MR images to computer-assisted bone tumour surgery without CT–MR image fusion possible. A paired-point registration technique was employed for patient-image registration in all patients. It took 20 min on average to set up the navigation (range 15 to 25 minutes). The mean registration error was 0.98 mm (range 0.4 to 1.7 mm). On histologic examination, distances from tumours to resection margins were in accord with preoperative plans. Mean duration of follow-up was 25.8 months (range 18 to 32 months). No patient had a local recurrence or distant metastasis at the last follow-up. Direct patient-to-MRI registration is a very useful method for bone tumour surgery, permitting the application of MR images to intraoperative visualization without any additional costs or exposure of the patient to radiation from the preoperative CT scan.