Robotics have been applied to total knee arthroplasty (TKA) to improve surgical precision in component placement and joint function restoration. The purpose of this study was to evaluate prosthetic component alignment in robotic arm-assisted (RA)-TKA performed with functional alignment and intraoperative fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. It was hypothesized that functionally aligned RA-TKA the femoral and tibial cuts would be performed in line with the preoperative joint line orientation.

Methods

Between September 2018 and January 2020, 81 RA cruciate retaining (CR) and posterior stabilized (PS) TKAs were performed at a single center. Preoperative radiographs were obtained, and measures were performed according to Paley's. Preoperatively, cuts were planned based on radiographic epiphyseal anatomies and respecting ±3° boundaries from neutral coronal alignment. Intraoperatively, the tibial and femoral cuts were modified based on the individual soft tissue-guided fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. Robotic data were recorded.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 17 - 17
1 Feb 2021
Catani F Marcovigi A Zambianchi F
Full Access

Introduction

Dislocation is a major cause of Total Hip Arthroplasty (THA) early failure and is highly influenced by surgical approach and component positioning. Robotic assisted arthroplasty has been developed to improve component positioning and therefore reduce post-operative complications.

The purpose of this study was to assess dislocation rate in robotic total hip arthroplasty performed with three different surgical approaches.

Methods

All patients undergoing Robotic Arm-Assisted THA at three centers between 2014 and 2019 were included for assessment. After exclusion, 1059 patients were considered; an anterior approach was performed in 323 patients (Center 2), lateral approach in 394 patients (Center 1 and Center 2) and posterior approach in 394 patients (Center 1 and Center 3).

Episodes of THA dislocation at 6 months of follow up were recorded. Stem anteversion, Cup anteversion, Cup inclination and Combined Anteversion were collected with the use of the integrated navigation system.

Cumulative incidence (CI), incidence rate (IR) and risk ratio (RR) were calculated with a confidence interval of 95%.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 73 - 73
1 Feb 2020
Catani F Ensini A Zambianchi F Illuminati A Matveitchouk N
Full Access

Introduction

Robotics have been applied to total knee arthroplasty (TKA) to improve surgical precision in components’ placement, providing a physiologic ligament tensioning throughout knee range of motion. The purpose of the present study is to evaluate femoral and tibial components’ positioning in robotic-assisted TKA after fine-tuning according to soft tissue tensioning, aiming symmetric and balanced medial and lateral gaps in flexion/extension.

Materials and Methods

Forty-three consecutive patients undergoing robotic-assisted TKA between November 2017 and November 2018 were included. Pre-operative radiographs were performed and measured according to Paley's. The tibial and femoral cuts were performed based on the individual intra-operative fine-tuning, checking for components’ size and placement, aiming symmetric medial and lateral gaps in flexion/extension. Cuts were adapted to radiographic epiphyseal anatomy and respecting ±2° boundaries from neutral coronal alignment. Robotic data were recorded, collecting information relative to medial and lateral gaps in flexion and extension.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 40 - 40
1 Feb 2020
Tarallo L Porcellini G Giorgini A Pellegrini A Catani F
Full Access

Introduction

Total shoulder replacement is a successful treatment for gleno-humeral osteoarthritis. However, components loosening and painful prostheses, related to components wrong positioning, are still a problem for those patients who underwent this kind of surgery. CT-based intraoperative navigation system is a suitable option to improve accuracy and precision of the implants as previously described in literature for others district.

Method

Eleven reverse shoulder prostheses were performed at Modena Polyclinic from October 2018 to April 2019 using GPS CT-based intraoperative navigation system (Exactech, Gainsville, Florida). In the preoperative planning, Walch classification was used to assess glenoid type. The choice of inclination of the glenoid component, the screw length, as well as the inclination of the reamer was study and recorded using specific software using the CT scan of shoulder of each patient (Fig.1, Fig.2). Intraoperative and perioperative complications were recorded. Three patients were male, eight were female. Mean age was 72 years old (range 58=84). Three glenoid were type B2, six cases were B1, two case were type C1.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 121 - 121
1 Apr 2019
Renders T Heyse T Catani F Sussmann P De Corte R Labey L
Full Access

Introduction

Unicompartmental knee arthroplasty (UKA) currently experiences increased popularity. It is usually assumed that UKA shows kinematic features closer to the natural knee than total knee arthroplasty (TKA). Especially in younger patients more natural knee function and faster recovery have helped to increase the popularity of UKA. Another leading reason for the popularity of UKA is the ability to preserve the remaining healthy tissues in the knee, which is not always possible in TKA. Many biomechanical questions remain, however, with respect to this type of replacement.

25% of knees with medial compartment osteoarthritis also have a deficient anterior cruciate ligament [1]. In current clinical practice, medial UKA would be contraindicated in these patients. Our hypothesis is that kinematics after UKA in combination with ACL reconstruction should allow to restore joint function close to the native knee joint. This is clinically relevant, because functional benefits for medial UKA should especially be attractive to the young and active patient.

Materials and Methods

Six fresh frozen full leg cadaver specimens were prepared to be mounted in a kinematic rig (Figure 1) with six degrees of freedom for the knee joint. Three motion patterns were applied: passive flexion-extension, open chain extension, and squatting. These motion patterns were performed in four situations for each specimen: with the native knee; after implantation of a medial UKA (Figure 2); next after cutting the ACL and finally after reconstruction of the ACL. During the loaded motions, quadriceps and hamstrings muscle forces were applied. Infrared cameras continuously recorded the trajectories of marker frames rigidly attached to femur, tibia and patella. Prior computer tomography allowed identification of coordinate frames of the bones and calculations of anatomical rotations and translations. Strains in the collateral ligaments were calculated from insertion site distances.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 45 - 45
1 Mar 2017
Tarallo L Mugnai R Catani F
Full Access

Background

Currently, stailess steel, titanium and carbon-fiber reinforced polyetheretherketone (CF-PEEK) plates are available for the treatment of distal radius fractures. Since the possibility to create a less rigid fixation may represent an advantage in case of ostheoporotic or poor quality bone, the aim of this study is to compare the biomechanical properties of these three materials in terms of bending stiffness with a single static load and after cyclical loading, simulating physiologic wrist motion.

Materials and Methods

Three volar plating systems with fixed angle were tested: Zimmer stainless steel volar lateral column (Warsaw, IN); Hand Innovations titanium DVR (Miami, FL); Lima Corporate CF-PEEK DiPHOS-RM (San Daniele Del Friuli, Udine, Italy). For each type of plate tested four right synthetic composite bone radii were used. An unstable, extraarticular fracture was simulated by making an 8 mm gap with a saw starting 12 mm proximal to the articular surface of the radius on the distal radio-ulnar joint side. The osteotomies were made perpendicular to the long axis of the bone to allow for a consistent fracture gap on the dorsal and volar sides of the radius. Plates were implanted using all the distal and proximal fixation holes [Fig. 1]. Each synthetic radius model was potted in methylmethacrylate and tested in a bi-axial servo-hydraulic test frame (MTS Minibionix 858, universal testing machine) for load to failure by advancing a cobalt chrome sphere centered over the articular surface at a constant rate of displacement of 5 mm/min. The sphere was advanced until the construct failed or the dorsal edges of the fracture met. The resultant force was defined as bending stiffness pre fatigue. Three constructs for each plate were then dynamically loaded for 6000 cycles of fatigue at a frequency of 10Hz, with a load value corresponding to the 50% of the previously calculated bending strength. Finally, the constructs were loaded to failure, measuring the bending stiffness post fatigue.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 75 - 75
1 May 2016
Tarallo L Mugnai R Catani F
Full Access

Background

Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of metal allergies, radiolucency, low artifacts on magnetic resonance imaging scans and the possibility of tailoring mechanical properties. The purpose of this study was to evaluate the clinical results at mean 24-month follow-up using a new plate made of carbon-fiber-reinforced polyetheretherketon (CFR-PEEK) for the treatment of distal radius fractures.

Materials and methods

We performed a prospective study including all patients who were treated for unstable distal radius fracture with a CFR-PEEK volar fixed angle plate. We included 70 consecutive fractures of AO types B and C that remained displaced after an initial attempt at reduction. The fractures were classified according to the AO classification: 35 fractures were type C1, 13 were type C2, 6 were type C3, 5 were type B1 and 11 were type B2.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 23 - 23
1 Dec 2013
Fiacchi F Catani F Digennaro V Gialdini M Grandi G
Full Access

Orthopaedic surgeons and their patients continue to seek better functional outcomes after total knee replacement, but TKA designs claim characteristic kinematic performance that is rarely assessed in patients.

The objectives of this investigation is to determine the in vivo kinematics in knees with Cruciate Retaining TKA using Patient Specific Technology during activities of daily living and to compare the findings with previous studies of kinematics of other CR TKA designs.

Four knees were operated by Triathlon CR TKA using Patient Specific Technology and a fluoroscopic measurement technique has been used to provide detailed three-dimensional kinematic assessment of knee arthroplasty function during three motor tasks. 3D fluoroscopic analysis was performed at 4-month follow-up.

The range of flexion was 90°(range 5°–95°) during chair-rising, 80°(range 0°–80°) during step up and 100° (range 0°–100°) during leg extension. The corresponding average external rotation of the femur on the tibial base-plate was 7.6° (range +4.3°; +11.9°), 9.5° (+4.0°; 13.5°) and 11.6° (+4.5°; +16.1°). The mean antero-posterior translations between femoral and tibial components during the three motor tasks were +4.7 (−3.7; +1.0), +6.4 (−3.8; +2.6) and +8,4 (−4.9; +3.5) mm on the medial compartment, and −2.5 (−7.1; −9.6), −3.6 (−6.1; −9.7), −2.6 (−7.7; −10.3) mm on the lateral compartment, respectively, with the medial condyle moving progressively anterior with flexion, and the medial condyle moving progressively posterior with flexion.

We compared Triathlon CR PSI TKA results from this study with Genesis II CR TKA, with Duracon CR TKA, with Triathlon CR TKA and with the healthy knee kinematics. The results of this study showed no screw home mechanism. The internal rotation of the tibia with knee flexion is close to normal, better than Genesis II, Duracon and Triathlon CR TKA operated with standard surgery.

The medial condyle is characterized by the same pattern of the other implants, with a paradoxical anterior translation of 5 mm.

The lateral condyle shows a posterior rollback better than Triathlon CR operated with standard surgery.

For the first time is demonstrated that the surgical technique can modify the tibio-femoral kinematics.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 66 - 66
1 Oct 2012
Belvedere C Ensini A De La Barrera JM Feliciangeli A Leardini A Catani F
Full Access

During total knee replacement (TKR), surgical navigation systems (SNS) allow accurate prosthesis component implantation by tracking the tibio-femoral joint (TFJ) kinematics in the original articulation at the beginning of the operation, after relevant trial components implantation, and, ultimately, after final component implantation and cementation. It is known that TKR also alters normal patello-femoral joint (PFJ) kinematics resulting frequently in PFJ disorders and TKR failure. More importantly, patellar tracking in case of resurfacing is further affected by patellar bone preparation and relevant component positioning. The traditional technique used to perform patellar resurfacing, even in navigated TKR, is based only on visual inspection of the patellar articular aspect for clamping patellar cutting jig and on a simple calliper to check for patellar thickness before and after bone cut, and, thus, without any computer assistance. Even though the inclusion in in-vivo navigated TKR of a procedure for supporting also patellar resurfacing based on patient-specific bone morphology seems fundamental, this have been completely disregarded till now, whose efficacy being assessed only in-vitro. This procedure has been developed, together with relevant software and surgical instrumentation, as an extension of current SNS, i.e. TKR is navigated, at the same time measuring the effects of every surgical action on PFJ kinematics. The aim of this study was to report on the first in-vivo experiences during TKR with patellar resurfacing.

Four patients affected by primary gonarthrosis were implanted with a fixed bearing posterior-stabilised prosthesis (NRG, Stryker®-Orthopaedics, Mahwah, NJ-USA) with patellar resurfacing. All TKR were performed by means of two SNS (Stryker®-Leibinger, Freiburg, Germany) with the standard femoral/tibial trackers, the pointer, and a specially-designed patellar tracker. The novel procedure for patellar tracking was approved by the local ethical committee; the patients gave informed consent prior the surgery. This procedure implies the use of a second system, i.e. the patellar SNS (PSNS), with dedicated software for supporting patellar resurfacing and relative data processing/storing, in addition to the traditional knee SNS (KSNS). TFJ anatomical survey and kinematics data are shared between the two. Before surgery, both systems were initialised and the patellar tracker was assembled with a sterile procedure by shaping a metal grid mounted with three markers to be tracked by PSNS only. The additional patellar-resection-plane and patellar-cut-verification probes were instrumented with a standard tracker and a relevant reference frame was defined on these by digitisation with PSNS. Afterwards, the procedures for standard navigation were performed to calculate preoperative joint deformities and TFJ kinematics. The anatomical survey was performed also with PSNS, with relevant patellar anatomical reference frame definition and PFJ kinematics assessment according to a recent proposal. Standard procedures for femoral and tibial component implantation, and TFJ kinematics assessment were then performed by using relevant trial components. Afterwards, the procedure for patellar resection begun. Once the surgeon had arranged and fixed the patellar cutting jig at the desired position, the patellar-resection-plane probe was inserted into the slot for the saw blade. With this in place, the PSNS captured tracker data to calculate the planned level of patellar bone cut and the patellar cut orientation. Then the cut was executed, and the accuracy of this actual bone cut was assessed by means of the patellar-cut-verification probe. The trial patellar component was positioned, and, with all three trial components in place, TFJ and PFJ kinematics were assessed. Possible adjustments in component positioning could still be performed, until both kinematics were satisfactory. Finally, final components were implanted and cemented, and final TFJ and PFJ kinematics were acquired. A sterile calliper and pre- and post-implantation lower limb X-rays were used to check for the patellar thickness and final lower limb alignment. The novel surgical technique was performed successfully in all four cases without complication, resulting in 30 min longer TKR. The final lower limb alignment was within 0.5°, the resurfaced patella was 0.4±1.3 mm thinner than in the native, the patellar cut was 1.5°±3.0° laterally tilted. PFJ kinematics was taken within the reference normality. The patella implantation parameters were confirmed also by X-ray inspection; discrepancies in thickness up to 5 mm were observed between SNS- and calliper-based measurements.

At the present experimental phase, a second separate PSNS was utilised not to affect the standard navigated TKR. The results reported support relevance, feasibility and efficacy of patellar tracking and PFJ kinematics assessment in in-vivo navigated TKR. The encouraging in-vivo results may lay ground for the design of a future clinical patella navigation system the surgeon could use to perform a more comprehensive assessment of the original whole knee anatomy and kinematics, i.e. including also PFJ. Patellar bone preparation would be supported for suitable patellar component positioning in case of resurfacing but, conceptually, also in not resurfacing if patellar anatomy and tracking assessment by SNS reveals no abnormality. After suitable adjustment and further tests, in the future if this procedure will be routinely applied during navigated TKR, abnormalities at both TFJ and PFJ can be corrected intra-operatively by more cautious bone cut preparation on the femur, tibia and also patella, in case of resurfacing, and by correct prosthetic component positioning.