To determine the risk of total knee replacement (TKR) for primary osteoarthritis (OA) associated with overweight/obesity in the Australian population. This population-based study analyzed 191,723 cases of TKR collected by the Australian Orthopaedic Association National Joint Registry and population data from the Australian Bureau of Statistics. The time-trend change in incidence of TKR relating to BMI was assessed between 2015-2018. The influence of obesity on the incidence of TKR in different age and gender groups was determined. The population attributable fraction (PAF) was then calculated to estimate the effect of obesity reduction on TKR incidence. The greatest increase in incidence of TKR was seen in patients from obese class III. The incidence rate ratio for having a TKR for obesity class III was 28.683 at those aged 18-54 years but was 2.029 at those aged >75 years. Females in obesity class III were 1.7 times more likely to undergo TKR compared to similarly classified males. The PAFs of TKR associated with overweight or obesity was 35%, estimating 12,156 cases of TKR attributable to obesity in 2018. The proportion of TKRs could be reduced by 20% if overweight and obese population move down one category. Obesity has resulted in a significant increase in the incidence of TKR in the youngest population in Australia. The impact of obesity is greatest in the young and the female population. Effective strategies to reduce the national obese population could potentially reduce 35% of the TKR, with over 10,000 cases being avoided.
Proximal femoral focal deficiency is a congenital disorder of malformation of the proximal femur and/or the acetabulum. Patients present with limb length discrepancy and clinical features along a spectrum of severity. As these patients progress through to skeletal maturity and on to adulthood, altered biomechanical demands lead to progression of arthropathy in any joint within the lower limb. Abnormal anatomy presents a challenge to surgeons and conventional approaches and implants may not necessarily be applicable. We present a case of a 62-year-old lady with unilateral proximal femoral focal deficiency (suspected Aitken Class A) who ambulated with an equinus prosthesis for her entire life. She presented with ipsilateral knee pain and instability due to knee arthritis but could not tolerate a total knee arthroplasty due to poor quadriceps control. A custom osteointegration prosthesis was inserted with a view to converting to the proximal segment to a total hip replacement if required. The patient went on to develop ipsilateral symptomatic hip arthritis but altered acetabular anatomy required a custom tri-flange component (Ossis, Christchurch, New Zealand) and a custom proximal femoral component to link with the existing osseointegration component (Osseointegration Group of Australia, Sydney, Australia) were designed and implanted. The 18 month follow up of the custom hip components showed that the patient had Oxford hip scores that were markedly improved from pre-operatively. Knee joint heights were successfully restored to equal when the patient's prosthesis was attached. The patient describes feeling like “a normal person”, walks unaided for short distances and can ambulate longer distances with crutches. Advances in design and manufacture of implants have empowered surgeons to offer life improving treatments to patients with challenging anatomy. Using a custom acetabular tri-flange and osseointegration components is one possible solution to address symptomatic ipsilateral hip and knee arthropathy in the context of PFFD in adulthood.
Rates of prosthetic joint infection in megaprostheses are high. The application of silver ion coating to implants serves as a deterrent to infection and biofilm formation. A retrospective review was performed of all silver-coated MUTARS endoprosthetic reconstructions (SC-EPR) by a single Orthopaedic Oncology Surgeon. We examined the rate of component revision due to infection and the rate of infection successfully treated with antibiotic therapy. We reviewed overall revision rates, sub-categorised into the Henderson groupings for endoprosthesis modes of failure (Type 1 soft tissue failure, Type 2 aseptic loosening, Type 3 Structural failure, Type 4 Infection, Type 5 tumour progression). 283 silver-coated MUTARS endoprosthetic reconstructions were performed for 229 patients from October 2012 to July 2022. The average age at time of surgery was 58.9 years and 53% of our cohort were males. 154 (71.3%) patients underwent SC-EPR for oncological reconstruction and 32 (14.8%) for reconstruction for bone loss following prosthetic joint infection(s). Proximal femur SC-EPR (82) and distal femur (90) were the most common procedures. This cohort had an overall revision rate of 21.2% (60/283 cases). Component revisions were most commonly due to Type 4 infection (19 cases), Type 2 aseptic loosening/culture negative disease (15 cases), and Type 1 dislocation/soft tissue (12 cases). Component revision rate for infection was 6.7% (19 cases). 15 underwent exchange of implants and 4 underwent transfemoral amputation due to recalcitrant infection and failure of soft tissue coverage. This equates to a limb salvage rate of 98.3%. The most common causative organisms remain staphylococcus species (47%) and polymicrobial infections (40%). We expand on the existing literature advocating for the use of silver-coated endoprosthetic reconstructions. We provide insights from the vast experience of a single surgeon when addressing patients with oncological and bone loss-related complex reconstruction problems.
The Australia and New Zealand Sarcoma Association established the Sarcoma Guidelines Working Party to develop national guidelines for the management of Sarcoma. We asked whether surgery at a specialised centre improves outcomes. A systematic review was performed of all available evidence pertaining to paediatric or adult patients treated for bone or soft tissue sarcoma at a specialised centre compared with non-specialised centres. Outcomes assessed included local control, limb salvage rate, 30-day and 90-day surgical mortality, and overall survival. Definitive surgical management at a specialised sarcoma centre improves local control as defined by margin negative surgery, local or locoregional recurrence, and local recurrence free survival. Limb conservation rates are higher at specialised centres, due in part to the depth of surgical experience and immediate availability of multidisciplinary and multimodal therapy. A statistically significant correlation did not exist for 30-day and 90-day mortality between specialised centres and non-specialised centres. The literature is consistent with improved survival when definitive surgical treatment is performed at a specialised sarcoma centre. Evidence-based recommendation: Patients with suspected sarcoma to be referred to a specialised sarcoma centre for surgical management to reduce the risk of local recurrence, surgical complication, and to improve limb conservation and survival. Practice point: Patients with suspected sarcoma should be referred to a specialised sarcoma centre early for management including planned biopsy.
Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany). At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both patients remain asymptomatic. 3 patients were readmitted for dislocations, 1 of whom had 5 dislocations within 3 weeks post-operatively and was immobilised in an abduction brace to address a lack of muscle tone and has not had a revision of their components. Utilising navigation with meticulous implant design and construction; augmented with an ultrathin plasma coating of silver particles embedded between layers of siloxane with controlled and long-term generation of silver ion diffusion has led to outstanding outcomes in this series of 12 custom acetabular and hemipelvis reconstructions. No patients were revised for infection and no patients show signs of failure of bone on growth and incorporation. Hip instability remains a problem in these challenging mechanical environments and we continue to reassess our approach to this multifaceted problem.
In a society whereby the incidence of obesity is increasing and medico-legal implications of treatment failure are more frequently ending with the consulting doctor, clarity is required as to any restrictions placed on common orthopaedic implants by manufacturing companies. The aim of this study was to identify any restrictions placed on the commonly used femoral stem implants in total hip replacement (THR) surgery, by the manufacturers, based on patient weight. The United Kingdom (UK) National Joint Registry (NJR) was used to identify the five most commonly used cemented and uncemented femoral stem implants during 2012. The manufacturing companies responsible for these implants were asked to provide details of any weight restrictions placed on these implants. The Corail size 6 stem is the only implant to have a weight restriction (60Kg). All other stems, both cemented and uncemented, were free of any restrictions. Fatigue fracture of the femoral stem has been well documented in the literature, particularly involving the high nitrogen stainless steel cemented femoral stems and to a lesser extent the cemented cobalt chrome and uncemented femoral stems. In all cases excessive patient weight leading to increased cantilever bending of the femoral stem was thought to be a major factor contributing to the failure mechanism. From the current literature there is clearly an association between excessive patient weight and fatigue failure of the femoral stem. We suggest avoiding, where possible, the insertion of small stems (particularly cemented stems) and large offset stems (particularly those with a modular neck) in overweight patients.
Cite this article:
The importance for observing the intention-to-treat
approach in clinical studies is explained. Cite this article:
Richard Carey Smith is an orthopaedic oncology surgeon with fellowship training in the UK, USA, Australia and Canada, and has worked in Zambia, Zimbabwe and Papa New Guinea. David Wood is head of the University Department of Orthopaedics in Perth, Western Australia. He did his masters in Africa, and first experienced Papa New Guinea on his medical elective, starting a lifelong commitment to medical aid work there.
Surgery for degenerative lumbar spondylolisthesis may entail both decompression and fusion. The knee-chest position facilitates the decompression, but fixation in this position risks fusion in kyphosis. This can be avoided by intra-operative re-positioning to the prone position. The aim of this study was to quantify the restoration of lordosis achieved by intra-operative repositioning and to assess the clinical and radiological outcome. A total of forty consecutive patients with degenerative lumbar spondylolisthesis and stenosis were treated by posterior decompression and interbody fusion with pedicle screw fixation. The screw insertion, decompression and interbody grafting were performed with the patient in the knee-chest position. The patient was then re-positioned to the fully prone position for fusion. Sagittal plane angles were measured pre-, intra- and post-operatively. Clinical assessment was performed using SF-36 scores and visual analogue scores for back and leg pain. The sagittal plane angle increased from median 16.0 degrees pre-operatively to 23.1 degrees post-operatively (p<0.01) and this was maintained at the last follow-up (mean 21 months). The SF-36 scores improved for 7 out of 8 domains and the physical score improved from 29% to 40% (p<0.05). The mean pain scores improved significantly from 7.5 to 3.8 for back pain and from 7.6 to 3.7 for leg pain (p<0.001). Lumbar spondylolisthesis was found to be associated with a reduction of normal lumbar lordosis and the knee-chest position exacerbates this loss of lordosis. Intra-operative repositioning restored lordosis to greater than the pre-operative angle and was associated with a good clinical outcome.
We aim to assess the clinical and radiological outcome following cartilage repair in the knee using the TruFit plug (Smith &
Nephew). Eleven active sporting patients underwent cartilage repair using TruFit plugs between February 2006 and August 2007. Postoperatively patients were touch weight bearing for 2 weeks and partial until 4 weeks. Data was collected prospectively, patients underwent clinical review and completed Lysholm, IKDC subjective, Tegner, KOOS and SF-36 scores pre-operatively and at 6 monthly intervals. One patient has been excluded from the analysis as she emigrated and was lost to follow up. The remaining 10 patients (mean age 35 years (21–49)) had defects on the medial femoral condyle (n=6), lateral femoral condyle (n=3), and lateral trochlea (n=1). Patients received one (n=5), two (n=3) or three (n=2) plugs and four were primary procedures, and six revision procedures (1 failed OATS, 5 failed microfracture). Eight implantations were performed arthroscopically and, and two were mini-open. All patients were reviewed at 12 months, five were reviewed at 18 months and four have also been reviewed at 24 months. Statistically significant improvements from mean pre-operative scores are seen at 12 months; Lysholm (48.3 to 71), IKDC Subjective (37.7 to 65.1), Tegner (2.4 to 4.6), SF36 physical (39.5 to 50.3) and all components of KOOS. These improvements are maintained at the latest follow up. MRI evaluation including T2 mapping demonstrates reformation of the subchondral lamina, resorption of the graft and a similar signal from neo-cartilage as that of adjacent native cartilage. TruFit plugs offer an exciting novel solution for cartilage repair in the knee with advantages of low morbidity and rapid recovery without the need for prolonged non-weight bearing. The implant may be suitable for small lesions only and further prospective study is required to establish long-term outcome.
We have conducted a prospective, observational clinical trial of 34 patients with dual compartment osteoarthritis of the knee treated with a 2/3 Knee.
Exclusion criteria included obesity, inflammatory arthritis and a fixed flexion deformity >
10 degrees. Subjective outcome measures included Oxford Knee Scores (OKS) and EQ-5D Scores. RSA beads were implanted at surgery to detect loosening, micro-motion and prosthesis wear. Gait analysis was conducted at 1 year post op in a subgroup of patients.
The patients have recorded Significant improvement in their Oxford Knee Scores at 6 months (mean reduction all patients: 17.3, resurfaced 20). Early RSA results have not detected Significant migration to indicate early loosening. Gait analysis has shown that patients return to approximate normal rather than pre-operative gait.
It is essential that patients undergo primary patella resurfacing to prevent crepitus and associated anterior knee pain. A study comparing clinical outcomes of 2/3 Knee vs TKA is underway at our institution.
The purpose of this study was to assess the accuracy of a modified version of the pivot shift test in detecting ruptures of the anterior cruciate (ACL) ligament.
Midvastus vs Medial Parapatellar approach: Quadriceps function in the early post operative period was better preserved in the MV group. Post operative pain, blood loss and the need for LRR tended to be lower in the MV group. There was no difference in ROM, hospital stay, knee scores, complications or radiological alignment. Subvastus vs Medial Parapatellar approach: Quadriceps function was better preserved in the SV group up to 3 months post operatively. ROM was generally greater up to the 4 week time point. Post operative pain and blood loss was lower in the SV group. There was no difference in operative/tourniquet time, hospital stay, rate of LRR, or complications. Modified “Quadriceps sparing” Medial Parapatellar vs Mini-Subvastus (MSV) approach: A tendency for earlier restoration of SLR and better early ROM was noted in the MSV group. Midvastus vs Subvastus approach: The SV group suffered with significantly more pain at six months post operatively.
Assessment by VAS and Oswestry Disability Questionnaire showed improvement across all groups. Pre-op ODQ (mean 49.35, SD 16.55) decreased at 6 months (mean 26.00, SD 25.85) and at 12 months (mean 24.18, SD 19.50). This was significant (p<
.001). Pre-op VAS (mean 69.54, SD 19.80) decreased at 6 months (mean 26.00, SD 25.85) and at 12 months (mean 28.50, SD 22.00). This was significant (p<
.001).